If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 89,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682154_1Tender No
GES/PKT/56/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed.
90
-
-
Removing excavated materials (soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
97
-
-
M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in foundation, filling, mass concrete, complete all as specified and directed.
23
-
-
M&L for Reinforced cement concrete M-25 (design mix), using 20mm graded crushed stone aggregates as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
70
-
-
M&L for RCC M-25 (design mix), using 20mm graded crushed stone aggregates as in columns, pillars etc., complete all as specified and directed.
18
-
-
M&L for reinforced cement concrete M-25 (design mix) using 20mm aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
25
-
-
M&L for Reinforced cement concrete M-25 (design mix), using 20mm graded crushed stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
52
-
-
M&L for Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed.
253
-
-
M&L for Formwork to sides of square or rectangular pillars, posts, struts, columns etc., with rough finished surfaces of concrete, complete all as specified and directed.
183
-
-
M&L for Formwork to sides and soffits of floor or roof beams,, splays between floor and beams etc., with rough finished surfaces of concrete, complete all as specified and directed.
90
-
-
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), with rough finished surfaces of concrete, complete all as specified and directed.
350
-
-
M&L for ATT by treating the backfill of excavation in contact with foundation at the rate of 7.5 litres of emulsion per sqm of vertical surface area (Area of sub-struture in contact with backfill to be measured), complete all as specified and directed.
29
-
-
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & directed.
82
-
-
M&L for ATT by treating the top surface of filled earth at the rate of 5 litres emulsion per sqm of surface area, complete all as specified and directed.
285
-
-
M&L for ATT by treating the soil under plinth protection at the rate of 5 litres of emulsion per Sqm of surface area, complete all as specified and directed.
38
-
-
M&L TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc. and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed.
12000
-
-
M&L TMT bars 5mm dia and over upto and incl 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including bending, cranking etc. and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed.
3000
-
-
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4, complete all as specified and directed.
55
-
-
M&L for rendering 15 mm thick in cm 1:6 on other than faces of block masonry /brick work surfaces finished even and smooth without using extra cement, complete all as specified and directed.
216
-
-
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed.
216
-
-
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed.
275
-
-
M&L for two coats of cement base paint over a coat of primer including preparation of surface of wall complete all as specified.
235
-
-
M&L for preparation of concrete surface & applying two coats of oil bound distemper over one coat of primer as on Ceiling surfaces complete all as specified and directed.
275
-
-
M&L for applying two coats of oil bound distemper over one coat of primer as on walls surfaces complete all as specified and directed.
216
-
-
M&L 50mm thick PCC, type B-1, 1:2:4, (using 20mm graded crushed stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement complete all as specified and directed.
38
-
-
M&L for broken stone or boulder hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
45
-
-
M & L for Pavement quality concrete (PQC), 150mm thick, of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean, hard strong, dense, non-porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular, virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width, including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Required surface texturing to be done as specified in Clause 10.1.14 and Table 9 of IRC: 15-2017 complete all as spd & directed.
45
-
-
M&L for Forming 25 mm width expansion joint in concrete slab for full depth of PQC. Early entry saw and subsequent cutting by using diamond bit cutter appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. The joint then filled with pre-molded 25 mm thick compressible polyethylene closed cell type filler board as specified, thereafter application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and filled with polyurethane based sealant complying with BS 5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of+/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacture complete as specified and directed.
9.5
-
-
M&L for Cutting of construction joints 25 mm deep and 10 mm wide by early entry saw cut using diamond bit cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 12 mm dia, application of bond breaker tape on top of back up rod for complete width of the joint and filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN- 141875 2003 with minimum movement accommodation factor (MAF) of +I- 30% having minimum 10 year performance guarantee, applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete as specified and directed
9.5
-
-
M&L water proofing treatment to RCC roof slab, walls, chajjas etc, shall be carried out as specified below and as directed by Engr-in-charge(a) M & L for 10 mm thick plaster screed bed layer in CM 1:3 on concrete surfaces mixed with WPC @ 200ml per bag of cement. (b) Preparing plastered surfaces of roof slab, walls, chajjas etc, by brooming with broom sweeping free from dirt dust etc and applying one coat of oil based cold bituminous primer @ 0.40 litres per Sqm of area complete all as specified. (c) Laying APP polymer modified approved membrane, non woven, polyster, weighing not less than 3.5 Kg/Sqm and 3 mm thick with laps and overlaps as specified and joints sealed and applied complete by torch application method all as specified and directed by Engr-in-charge, Carrying out test by flooding water for 24 hrs for leakage and seepage and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified and as directed by Engr-in-charge.
350
-
-
M&L for point wiring with PVC insulated fire retardant stranded copper conductor cable of 1.5 sqmm in PVC concealed conduit heavy duty and pressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc. ) made of not less than 16 gauge MS sheet and 6cm depth covered with 3mm thick laminated bakelite sheet fitted with brass screw and washers and drawing 1.5 sqmm PVC insulated fire retardant stranded copper conductor cable as earth continuity wire in green colour connected to common earth and each terminal box/fitting all as specified and directed by Engr-in-Charge (Phase Neutral and earth wire shall be provided in standard colour code R,Y,B for phase, Black for neutral green for earth wire). Note: In ceiling portion surface conduit wiring shall be carried out.
-
-
-
One light point or one fan point or bell point controlled by one switch SP one way 230 Volts, complete all as specified and directed.
20
-
-
One socket out let 5/6 Amps on Independent board, complete all as specified and directed.
6
-
-
All as per serial item No. 36 here-in-before but for 15/16 Amps socket outlet independent with 4.0 sqmm copper conductor, complete all as specified and directed.
3
-
-
M&L for switch Piano flush type single pole one way 5/6 Amp , complete all as specified and directed.
20
-
-
M&L for switch, socket combination 2 in 1 , 3 pin, 5 and 15 Amp flush type all as specified and directed.
3
-
-
M&L for switch, socket combination 3 pin, 5 Amp flush type, complete all as specified and directed.
6
-
-
M&L for ceiling rose 2-3 terminal size 65x20mm, complete all as specified and directed.
20
-
-
S&F sheet metal enclosure with DB's (grouted in walls) double door type for MCB's 08 ways with 200 Amps 240 volts rated bus bar, complete all as specified and directed.
1
-
-
S&F 6 to 32 Amps rating 240V, 10KA 'C' curve MCB SP, complete with connection, testing, commissioning and all as specified and directed
12
-
-
S&F 32 Amp rating 240V, 10KA 'C' curve MCB SPN, complete with connection, testing, commissioning and all as specified and directed
1
-
-
S&F decorative box type fitting 4 feet long with LED tube light fitting 20 watt complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, complete all as specified and directed.
12
-
-
S&F bldg security light fittings with LED security light fittings 35 watt, IP 65 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe bracket 0.90 mtr long of 25 mm dia and fixing with bldg for fixing of street light fitting, complete all as specified and directed.
4
-
-
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
4
-
-
S&F MCCB 3 pole, 415V, fixed type, 25 to 100 Amps with breaking capacity 16 KA suitable for VTPN DB complete with connection, testing and commissioning, complete all as specified and directed.
1
-
-
S & F VTPN DBs Double Door 4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed
1
-
-
M&L for Sub main wiring in PVC concealed conduit with 2 Nos single core PVC insulated copper conductor cable FRLS size 6 sqmm multistrand in concealed conduit with 6 sqmm PVC insulated FRLS as earth continuity wire using suitable size of copper thimble including provn of PVC conduit heavy duty ISI marked of adequate size, complete all as specified and directed.
60
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical, plate No.3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed.
1
-
-
Supply and laying cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 70 Sq mm 3.5 core. Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning, cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule
70
-
-
Supply and laying cable XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 35 Sq mm 3.5 core. Note: Earth work (Excavation, Returning & refilling and removal), sand cushioning, cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule
50
-
-
Supplying and laying of DWC (Double wall corrugated) pipe of 50 mm bore laid for protection of cables in trenches, floors complete all as specified and directed.
110
-
-
Supply, installation, testing and commissioning of LT panel outdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate common access cable alley, made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 200 Amp,MCCB 4 Pole , 160 Amp, 415 V, 16 KA (Thermal magnetic release) adjustable overload setting- 01 Nos (incommer) & RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grage multi stranded PVC insulated copper conductor, incl powder coated painting in inner & outer side, including making all suitable necessary electrical connection complete all as directed by the Engineer-in- Charge. Note : (i) The panel shall be as per CPRI certificate (ii) The rates deemed to be inclusive necessary PCC for grouting of panels.
1
-
-
Material and labour for earthing with steel earth plate electrode of size 60cmx60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified including testing on completion. NOTE :- (i) Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing. (ii) Earth return filling should be with vegetable soil only free from stone and gravels.
2
-
-
Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%