Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 97,940Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683976_1Tender No
GE(AF)/ADM/T-52 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each, complete, all as specified and directed.
17
-
-
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified and directed.
13
-
-
M&L for PCC type C-2 (1:3:6), type C-2 using 40 mm graded crushed stone aggregates as in filling & mass concrete complete all as specified and directed.
18
-
-
M&L for PCC type D-2 (1:4:8), type D-2 using 40 mm graded crushed stone aggregates as in filling & mass concrete complete all as specified and directed.
3
-
-
Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
8
-
-
M&L for Reinforced cement concrete, type A-1(1:1½:3), (nominal mix) using 20 mm graded crushed stone aggregates as in columns, pillars, piers, posts and struts complete all as specified and directed.
4
-
-
M&L for Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified and directed.
30
-
-
M&L for Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified and directed.
40
-
-
M&L for Brick work using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified and directed.
15
-
-
M&L for Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed.
3
-
-
M&L for Brick work half brick thick wall using bricks as specified in PS clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
10
-
-
S&F Mild steel works as in framed brackets, angles,tees with web and flanges, cut to shape , drilled or counter sunk for screw, and welding angles, gusset plates, base plates, etc , riveting, anchoring bolts, etc confirming to Fe-290 or Gde E- 165 complete all as specified and as directed .
730
-
-
M&L for Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
600
-
-
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
600
-
-
S&F Mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) quality confirming to grade Fe-290-Gde E-165, complete all as specified and directed.
3000
-
-
S&F Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.
2900
-
-
S & F Mild steel flat, round or square bars in availabe length etc conirming to Fe- 290 or Gde E-165 complete, all as specified and directed.
600
-
-
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
600
-
-
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
100
-
-
S&F Stainles steel Spacers 20 to 30 mm complete all as specified and directed.
160
-
-
S&F mild steel Gate hinges bolt on Heavy duty pin 15 to 20 mm dia fixed to gate with all necessary arrrangment as specified and directed.
240
-
-
S&F Aluminium composite panel sheet 3-4 mm thick, of shade approved by GE, cut to shape and fixed in position on frame work as in wall inclduing framework, complete all as specified and directed.
3
-
-
M&L for 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed.
600
-
-
M&L for Factory made, rubber molded kerb stone and drainage channels of M-25 grade cement concrete, laid dry in position to the rquired line level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shal not be more than 5 mm) including making drainage opening whereever required, complete all as specified and directed.
2
-
-
M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
600
-
-
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4) complete all as specified and directed.
30
-
-
M&L for Two coats of cement base paint on new plastered wall surfaces, including preparation of surfaces, complete all as specified and directed.
30
-
-
M&L for Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
150
-
-
M&L for Reinforced concrete pipe class NP-2 150mm dia , ISI marked, laid in trenches including jointing & testing complete with collars complete all as specified and directed
12
-
-
M&L for Cement concrete (1:3:6) type C-2 using 40mm graded crushed stone aggregate as in bed to 150mm drain pipes of any description including packing under and haunching against the sides of pipe complete all as specified and directed
12
-
-
E/M WORKS :-
-
-
-
M&L for Point wiring with multi-stranded copper conductor, single core, FRLSH PVC insulated and unsheathed cable, including FRLSH PVC insulated unsheathed stranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with 3 mm thick plastic laminated sheet cover having necessary cutting for fixing switches/ sockets comprising the following: -
-
-
-
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
125
-
-
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specifiedand directed.
5
-
-
One Socket outlet three pin, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified and directed.
10
-
-
One Socket outlet three pin, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
60
-
-
One socket outlet three pin, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
45
-
-
One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
10
-
-
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable (for fixing modular switch/sockets) comprising the following: -
-
-
-
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
95
-
-
One light point controlled by two nos. 2-way switches with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
5
-
-
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified and directed.
10
-
-
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
30
-
-
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified and directed.
25
-
-
NOTES FOR SERIAL ITEM NOS 35 & 36: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed.
(c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
-
-
-
S&F Switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
250
-
-
S&F Switch piano flush button single pole two way, 6 Amp complete all as specified and directed.
5
-
-
S&F Switch piano, bell/buzzer push, flush button single pole one way, 6 Amp complete all as specified and directed.
25
-
-
S&F Switch piano flush button single pole one way, 16 Amp complete all as specified and directed.
60
-
-
S&F Socket outlet multipurpose having provision for 2&3 pin, 6 Amp, flush type, complete all as specified and directed.
30
-
-
S&F Socket outlet multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, flush type complete all as specified and directed.
60
-
-
S&F Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete all as specified and directed.
125
-
-
S&F Lamp (angle) holder, insulated body, cord grip pattern, complete all as specified and directed.
20
-
-
S&F Electric buzzer AC 230 volt, single pole, Ding Dong type complete all as specified and directed.
25
-
-
S&F Fan regulator (electronic) suitable for 48”/56” sweep fan, step socket type, single phase, complete all as specified.
60
-
-
S&F Switch modular type single pole one way, 6 Amp, complete all as specified and directed.
125
-
-
S&F Switch modular type single pole two way, 6 Amp, complete all as specified and directed.
15
-
-
S&F Bell push switch modular type single pole one way, 6 Amp, complete all as specified.
10
-
-
S&F Switch modular type single pole one way, 16 Amp,complete all as specified and directed.
25
-
-
S&F Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified and directed.
55
-
-
S&F Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified and directed.
75
-
-
S&F Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified and directed..
25
-
-
MAKE FOR SERIAL ITEM 37 TO 53: HAVELLS, LEGRAND or equivalent compatible make mentioned in Appendix 'B'.
-
-
-
S&F Sub main wiring (with approved colour coding as per IS) with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLSH PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
-
-
-
2 runs of 2.5 Sq. mm main cable + 1 run of 2.5 Sq. mm earth cable
150
-
-
2 runs of 4 Sq. mm main cable + 1 run of 4 Sq. mm earth cable
125
-
-
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable
105
-
-
NOTES: (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
-
-
-
S&F Rigid non metallic, PVC concealed conduit, 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified and directed.
155
-
-
S&F Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
-
-
-
SPN, 2 way with 200 Amp rated bus bar, 240 V.
5
-
-
SPN, 4 way with 200 Amp rated bus bar, 240 V, double door type.
10
-
-
SPN, 8 way with 200 Amp rated bus bar, 240 V, double door type.
15
-
-
SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
12
-
-
TPN, 4 way with 200 Amp rated bus bar, 415 V, double door type
10
-
-
S&F Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, TPN, 4 way with 200 Amp rated bus bar, 415 V, with and including MCCB 4 pole 63 Amp, 16kA., double door type, surface and flush mounting, complete all as specified and directed.
5
-
-
S&F MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified and directed.
175
-
-
S&F MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp, complete all as specified and directed.
50
-
-
S&F MCB suitable for 415 volt AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 63 Amp, complete all as specified and directed.
20
-
-
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified and directed.
10
-
-
S&F Envirnment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, IN REPLACEMENT, complete.
MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
35
-
-
S&F Surface mounted environment friendly LED batten with powder coated aluminium housing with intigrated electronic driver with THD10% LED 10W lighting fixture 2 feet long, 6500K, lumen output should not be less than 90 lumens per watt, including making connections, complete all as specified and directed.
MAKE: Havells Cat No. ENDURALINEARNEOBS10WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
50
-
-
S&F Surface mounted environment friendly with eye soft technology & glarefree diffuser LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete.
MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
150
-
-
S&F Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete all as specified and directed. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
25
-
-
Supply and Replacing round shape 6W, 220V AC, recessed type with high efficiency PMMA diffuser with soft glare free day light complete with drivers, holders, LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
30
-
-
Supply and Replacing round shape 12W, 220V AC, recessed type with high efficiency PMMA diffuser with soft glare free day light complete with drivers, holders, LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
25
-
-
M&L for Rewinding fan of any description with super enamelled copper winding wire of size, gauge & weight as per original specifications providing insulating material and varnishing with synthetic varnish, oiling, greasing including replacement of bush/bearing, condenser, 'U' clamp with reel to the entire satisfaction of Engineer-in-Charge including taking out burnt winding wire after opening the ceiling fan and other unserviceable parts, of size: -
-
-
-
Ceiling fan 1200 mm sweep
105
-
-
Ceiling fan 1400 mm sweep
25
-
-
Exhaust fan 300 mm sweep
24
-
-
Exhaust fan 450 mm sweep
8
-
-
Wall mounted fan 650 mm sweep
5
-
-
Cabin/table fan 450 mm sweep
5
-
-
NOTE: Collecton of fan items from EM store yard, transporting to workshop and back including loading unloading shall be measured & paid for separately under respective items of BoQ.
-
-
-
S&F PVC insulated & sheathed stranded aluminium conductor two core cable 1100 Volts of size 10 sq. mm ( nominal area) along with GI wire 4 sqmm conforming to IS 694 IN REPLACEMENT complete all as specified and directed.
200
-
-
M&L for Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 4 Sq. mm GI wire earthing lead complete all as shown in electrical plate No. 3 and specified in Particular Specifications clause 19.15.1 of contract, IN REPAIRS.
NOTE: (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate.
(b) Factory made PCC pit with cover shall be fixed at least 500 mm away from earth pit.
10
-
-
S&F Electric meter box, out door type, made out of MS CRCA sheet not less than 2 mm thick of size 650x900x250 mm with cable gally at centre and six compartments (for fixing electric meters) each have separate hinged door including provision of glass of size 90x90mm for taking reading, weather/ vermen proof IP-46 protection including provision of high quality rubber bedding on panel door, cable entry arrangements at bottom, all surfaces duly powder coated of shade approved by Eng-In-Charge and fixed in position with cement mortor (1:4), complete all as specified and directed.
20
-
-
S&F Exhaust fan 250 mm sweep with blades, frame and louvers, AC single phase, 230 V, plastic body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified and directed.
10
-
-
S&F Exhaust fan 300 mm sweep with blades, frame and louvers, AC single phase, 230 V, plastic body, heavy duty, fixed to wall with 10 mm dia fasteners, nuts & bolts and connecting up from ceiling rose or connector to fan, complete all as specified and directed.
5
-
-
DEMOLITION AND DISMANTELING WORKS :-
-
-
-
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
30
-
-
Demolition brickwork or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
19
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not excceding 15cm thickness (above or below ground level) complete all as specified and directed.
105
-
-
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
8
-
-
Dismantling wrought iron or mild steel work of any description, complete all as specified and directed.
15
-
-
Demolition and breaking up 150mm bore drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
12
-
-
Dismantling timber scantling 40 sq. cm and over in section, in any position, complete all as specified and directed..
3
-
-
Dismantling timber scantling under 40 sqcm in section as in fillets, rails, posts, rafters, purlins etc unframed work complete all as directed.
160
-
-
Dismantling plain or corrugated steel sheets in roof coverings, complete all as specified and directed..
700
-
-
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete with batten, casing caping of MS or and PVC conduit on surface or concealed, including switches, ceiling roses, pendants, regulators, sockets, mild steel terminal boxes etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
440
-
-
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit consealed/surface etc., removing materials and making good disturbed surfaces due to taking down etc. to the entire satisfaction of Engineer-In-Charge, complete all as specified and directed.
380
-
-
Dismantling of unservisible existing DBs of any description with all accessories and MCBs, isolators etc. and making good surface as per existing, complete all as specified and directed.
67
-
-
Taking down carefully light fitting of any description, complete all as specified and directed.
315
-
-
Taking down carefully electric bell/buzzer of any description, complete all as specified and directed.
25
-
-
Taking down carefully service cable of any description, complete all as specified and directed.
200
-
-
Notes: Amount of credit for retrieved materials is mentioned in tender documents in pdf form which will be deducted while acceptance of tender offline.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%