Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Eprocure
Opening Date15 May 2024
Closing Date30 May 2024
Tender Amount₹ 4,09,000
Costs
EMD
₹ 8,018Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_634673_4Bid Award Id
ViewTender No
AGE (I) DPR-34/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for PCC in foundation filling and mass concrete type B2 1:3:6 (40mm graded aggregate) all as specified and as directed.
0.65
-
-
M&L hardcore of guage n exc.63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface.
2
-
-
M&L 100mm for PCC in foundation filling and masss concrete 1:4:8 (40mm graded aggregate) all as specified and as directed.
2
-
-
M&L 150 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing and plinth protection..
16
-
-
M&L Sand filling 20mm thick under floors or in foundations including watering and consolidation complete all as specified & directed.
0.18
-
-
M & L machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade with grey cement and no pigmentas specified & as directed by Engr-in-Charge.
8.1
-
-
M&L Cement concrete 1:2:4 type B0 as in coping complete all as specified and directed by Engr-in-Charge.
0.1
-
-
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc.
650
-
-
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirming to Fe-410 Gde 250 quality A including distance pieces, cleats etc.
90
-
-
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
20
-
-
M&L for applying two coats of synthetic enamel paint steel surfaces of any description, over 10cm in width or girth,not otherwise described.
23.4
-
-
M & L brick work with subclass 'B' bricks straight or curved on plan to any radius bull in CM 1:6, complete all as specified and as directed.
2.42
-
-
M&L for rendering 15 mm thick in CM 1:6 on other than fair faces of brick or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified and directed.
22.4
-
-
M&L for preparation of new plastered surfaces and applying two coats of cement base paint complete all as specified and directed.
22.4
-
-
S & F in repairs 1000 litres capacity Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including Float valve complete all as specified and directed.
2
-
-
S&F 32mm dia brass chromium plated trap "P" or "S" pattern for wash basins and sinks for pipe or connections, and with one cleaning cap and fixed complete all as specified and directed
2
-
-
S&F PVC(HDPE) SWR ,75 mm bore 3- layer PP-R Polypropylene random copplymer ) conceleas pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches fixed complete all as specified and directed.
5
-
-
Removing Excavated soils not exceeding 50M and depositing where directed at a level not exceeding 1.5 M above the starting point.
1
-
-
E/M Portion
-
-
-
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for laying of CI / GI pipes laying in trenches and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
12.6
-
-
Returning, filling in trenches including , leveling watering and well ramming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed by Engr-in-Charge.
3.1
-
-
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level nexc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
9.5
-
-
Clean dry sand laid in trenches/ducts for bedding and cushioning to cable, 8cm in depth
before laying the cable and 15 cm in depth after laying the cable including spreading, levelling and consolidation complete all as specified and directed
Note : Consolidated/punned thickness of sand shall be measured for payment purpose..
2.9
-
-
Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat adjacently perpendicular to the axis of across the cable, complete all as specified and directed. (Excavation and earth work will be measured and paid separately)
1.12
-
-
Material & Labour for Galvanised Iron Pipe 20 mm dia medium grade galvanised with all fittings and fixed complete laid as in trenches / floorcomplete all as specified and directed by Engr-in-Charge.
40
-
-
Supply and fix in Gun Metal gate valve with Iron wheel head screwed both ends for GI steel tubing 20 mm dia complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply, laying, jointing, connecting, testing & commissioning UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty 1100 volts grade with standard aluminium conductor of cross sectional area 6 sqmm x 2 core all as specified and directed by Engr-in-Charge.
95
-
-
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes, modular plate suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:-
Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately.
-
-
-
(a) One light / fan / Bell point controlled by one switch
2
-
-
M& L Point wiring complete with 2.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including pressed steel terminal boxes, modular plate suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 2.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following:-
Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately.
4
-
-
S&F Modular switch 10 A, 1 module type single pole 240 volts of Anchor Roma Urban Cat Pat Code No 66101 10AX, 1Way Switch,HSN Code 8536 or equivalent in Legrand/Schneider specified colour complete all as specified and directed by the Engr-in-charge.
2
-
-
S&F Modular switch 16A, 1 module type single pole 240 volts of Anchor Roma Urban Cat Pat Code No 66101 16AX, 1Way Switch,HSN Code 8536 or equivalent in Legrand/Schneider specified colour complete all as specified and directed by the Engr-in-charge.
4
-
-
S&F Modular socket with safety shutter 16Amps 2/3 pin combined 2 module 240 Volts . complete all as specified and directed by the Engr-in-charge.
4
-
-
S&F LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge.
2
-
-
Supply and fixing ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and directed by Engr-in-Charge.
2
-
-
Supply and fixing MCB SP 6 -32 Amps,10 KA,,'C' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
4
-
-
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 53 class, including suitable size copper bus-bar, 240V,4 Way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate. Make : Legrand/ABB/Schenider
2
-
-
Supply and fixing MCB SPN 06-32 Amps,10 KA 'c' series 240 V ISI marked.complete all as specified and directed by Engr-in-Charge. Make: Legrand/ABB/Schenider
2
-
-
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and directed by Engr-in-Charge.
2
-
-
Material & Labour for Galvanised Iron Pipe 40 mm dia light grade galvanised with all fittings and fixed complete laid as in trenches / floor or for cable protectioncomplete all as specified and directed by Engr-in-Charge.
12
-
-
Make bore to road width for providing GI pipe medium/light grade both end socketed for passing armoured cable complete all as specifed.
12
-
-
Supply, installation, commissioning of self standing water cooler fully stainless steel, puff insulated body, electric driven single phase 230 Volts , 50 Hz having storage capacity of 120 Ltrs and nominal cooling capacity of60 Ltrs per hours with reciprocating compressor, eco friendley R-134A refrigent, externally mounted thermostate for easy regulating temperature with extra large stainless steel water tray for fast drainage of water complete all as specified and as directed.
2
-
-
Supply, installation , testing and commissioning voltage stablizer for automatic operation , single phase naturally air cooled indoor type and designed for input varriation between 170V to 290 V with output voltage stablized at 230 Volt with accuracy of (+, -) 2.5% and of capacity 2. KVA complete all as specifed and as directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements