Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date22 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR MAINT OF EXTERNAL ELECTRIFICATION INTERNAL ELECTRIFICATION COOLING APPLIANCES WATER SUPPLY PUMP WITH CONNECTED ITEMS AT 41 WEU JANDWAL UNDER AIR FORCE STATION PATHANKOT
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per srl item No 03 here in before but 4 way SPN single door with 200 amps rated bus bar complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
All as per srl item No 03 here in beflore but 4 way TPN 415 volts complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Supply only LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.

45

-

-

... More
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-charge.

18

-

-

... More
Supply and fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed by Engr-in-Charge.

13

-

-

... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-charge.

18

-

-

... More
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as shown in electrical plate No. 5 of MES schedule 1991 (Part-1) connected to earthing test point complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
Supply, fixing, installation, testing and commissioning in replacement CPRI approved LT electric panel totally enclosed (factory, fabricated) indoor type double door powder coated inside and outside made out of CRCA sheet not less than 2.00 mm thick with front and back opening having locking arrangment spray painting internally/externally including internal wiring with 500 Amp copper strip bus bar chamber 3 phase and four wire type system 415 volts 50 Hz consisting of copper bus bar of capacity 320 amps confirming to IS 13947 (Part-I & Part-III) of 1993 complete all as specified and directed by Engineer-in-charge and consisting of the following:- (i) MCCB 160 Amp, 25 KA 4 Pole with thermal magnetic release -01 No (Incoming) (ii) MCCB 100 amp 25 KA TPN-02 No (Outgoing) incl 01 No. Spare (iii) Single phase preventer 63 Amp (iv) Motor protection circuit breaker (MPCB) 63 Amp 50 KA (v) Starter Automatic star delta starter 40 HP - 01 No. (vi) Phase indicator - set of three (vii) Selector Switch, Voltmeter digital, Ammeter digital, Push button etc.

1

-

-

... More
Receiving/recording complaints lodged by the user/occupants of water Supply nature, rectification of the fault as per the compaint lodged by the user Overhead Water Tank excluding float valve complete repair to the extent by removing pipe connections, removing faults, including providing stores such as tee, unions, sockets, nuts, bolts required at the site to rectify the fault with regard to complaint lodged and re-fixing the fittings and fixtures to their original position as dismantled complete all as specified and directed by Engineer-in-charge.

150

-

-

... More
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed by Engineer-in-charge.

400

-

-

... More
Material and labour Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed by Engineer-in-charge.

320

-

-

... More
Removing excavated material and depositing where directed n exc 50m and level n exc 1.5m above the starting point complete all as specified and directed by Engineer-in-charge.

80

-

-

... More
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 80 mm (3”) dia complete all as specified and directed by Engineer-in-charge.

90

-

-

... More
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 50 mm (2”) dia complete all as specified and directed by Engineer-in-charge.

70

-

-

... More
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 40 mm (1.5”) dia complete all as specified and directed by Engineer-in-charge.

170

-

-

... More
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 25 mm (1.0”) dia complete all as specified and directed by Engineer-in-charge.

190

-

-

... More
Supply and lay in replacement pipe galvanized, “Medium class”, including fittings 20 mm (3/4”) dia complete all as specified and directed by Engineer-in-charge.

240

-

-

... More
Supply and fix in replacement Sluice Valve Class PN 1.6 for 80 mm dia pipe complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix in replacement Valve, globe conforming to IS 9338, 50 mm (2”) dia pipe complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply and fixing in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 40 mm (1.5”) dia complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
Supply and fixing in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm (1”) dia complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
All as per item above here in before but for size 20 mm dia pipe complete all as specified and directed by Engineer-in-charge.

22

-

-

... More
Material and labour for construction of valve pit including necessary excavation and earth work as required including necessary PCC work, brick work, plastering etc all as specified including fixing of MS sheet 6 mm thick cover and angle iron frame with locking arrangement including two coats of red oxide arrangement including two coats of red oxide primer internal size of pit 600X600X600mm complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix in replacement Non Return Sluice Valve for 80 mm dia pipe complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Supply and fix in replacement Sluice Valve Class PN 1.6 for 100 mm dia pipe complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Supply and fix in replacement Sluice Valve Class PN 1.6 for 150 mm dia pipe complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing in replacement submersible copper cable 16 Sqmm 3 core complete all as specified and directed by Engineer-in-charge.

90

-

-

... More
Material and labour for taking down unserviceable motor from site transporting to workshop and back after repair including dismantling of motor & taking out burnt winding and re-winding with enamelled copper wire of same gauge including providing insulation as per existing including re-assembling motor after repair including greasing of bearings, including alignment and testing at site complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
Receiving/recording complaints lodged by the user/occupants of electrification nature, rectification of the fault as per the compaint lodged by the user onward KWH meter in respect of main distribution board, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets, metal clad plug socket complete repair to the extent by removing connections from the system, removing faults in (surface /concealed), circuits, sunken boxes, Junction boxes, main switches, MCBs / DBs any type of utility light fittings, lamp holders, AC, ceiling fan/ exhaust fan and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the length of 2 mtr, insulation tape, screws, nuts required at the site to rectify the fault with regard to complaint lodged and re-fixing the fittings and fixtures to their original position as dismantled complete all as specified and directed by Engineer-in-charge. Note : (i) Any complaint left out / unattendent by the electrician will be communicated to the JE incharge /AGE E/M with reason. No charge will be paid for the complaint till the complaint is resolved. (ii) New material /stores provided for completing the job shall be measured and paid for separetely under relevant items of sch 'A'. (iii) Contractor shall provide all type of T&P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register complaint slip serially numbered in triplicate.

150

-

-

... More
Supply only switch piano type 5 Amps one way AC 230 Volts complete all as specified and directed by Engineer-in-charge.

120

-

-

... More
Supply only switch piano type 5 Amps two way AC 230 Volts complete all as specified and directed by Engineer-in-charge.

5

-

-

... More
Supply only switch piano type 15 Amps one way AC 230 Volts complete all as specified and directed by Engineer-in-charge.

60

-

-

... More
Supply only switch/socket combination outlet 3 pin 5 Amps flush type (Multi purpose) piano type AC 230 Volts complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
Supply only switch/socket combination outlet 5 pin 15 Amps flush type (Multi purpose) piano type AC 230 Volts complete all as specified and directed by Engineer-in-charge.

55

-

-

... More
Supply only ceiling rose 65x50mm two to three terminal AC 230 volts complete all as specified and directed by Engineer-in-charge.

50

-

-

... More
Supply only Bell electric AC 230 Volts single pole complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply only Bell push, flush type, 5 amp complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
Supply only lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
Supply & fix sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed by Engineer-in-charge.

20

-

-

... More
Supply only LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.

25

-

-

... More
Supply only LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge.

160

-

-

... More
Supply only round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.

20

-

-

... More
Supply only cable flexible PVC insulated twin core with copper conductor of size 1.5 Sq mm complete all as specified and directed by Engr-in-Charge.

290

-

-

... More
Supply only cable flexible PVC insulated twin core with copper conductor of size 2.5 Sq mm complete all as specified and directed by Engr-in-Charge.

210

-

-

... More
Supply only plug top 3 pin 5 Amp AC 230 volts complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply only plug top 3 pin 15 Amps AC 230 volts complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
All as per srl item No 55 here in beflore but size 175 x 100 x 50 mm deep complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
All as per srl item No 55 here in beflore but size 200 x 150 x 50 mm deep complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
All as per srl item No 55 here in beflore but size 350 x 300 x 50 mm deep complete all as specified and directed by Engr-in-Charge.

7

-

-

... More
Supply only capacitor AC 440 volts 2.5 mfd oil filled suitable for ceiling fan complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply only capacitor AC 440 volts 3.15 mfd oil filled suitable for exhaust fan complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
All as per srl item No 60 here in beflore but SP 40 AMP complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply only 240V, 10KA 'C' curve MCB SP and current carrying capacity 5 to 32 Amp in the MCB DB complete with connection testing and commissioning SP complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
Supply only 240V, 10KA 'C' curve MCB SPN and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply only 240V, 10KA 'C' curve MCB SPN and current carrying capacity 40 to 63 AMP in the MCB DB complete with connection testing and commissioning SP complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply and fixing aluminium thimble (lugs) bottle type suitable for MCBs with sub circuit wires complete all as specified and directed by Engr-in-Charge.

120

-

-

... More
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and directed by Engineer in charge.

40

-

-

... More
Supply only Rigid non-metallic PVC conduit of external dia 20 mm exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks complete all as specified and directed by Engineer in charge.

90

-

-

... More
All as per srl item No 67 here in beflore but of external dia 25 mm complete all as specified and directed by Engineer in charge.

70

-

-

... More
All as per srl item No 67 here in beflore but of external dia 40 mm complete all as specified and directed by Engineer in charge.

30

-

-

... More
Supply only twin sub main wire 4.00 Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable including continuous earth wire 2.5 Sqmm copper conductor insulated unsheathed complete all as specified and directed by Engineer in charge. Note : Two run of single core cable 4 sqmm and one run of 2.5 sqmm cable measured as a one unit.

160

-

-

... More
All as per srl item No 70 here in beflore but of 2x2.5 sq. mm + 1x1.5 sq. mm earth wire complete all as specified and directed by Engineer in charge.

120

-

-

... More
All as per srl item No 70 here in beflore but of 2x6.0 sq. mm + 1x4.0 sq. mm earth wire complete all as specified and directed by Engineer in charge.

140

-

-

... More
Periodical mainteneance of DG Set any capacity upto 125 KVA by replacing fuel filter , Lub oil filter , by pass filter , air cleaner inner and outer element , water seperator , , engine oil, cleaning of diesel tank , cleaning of radiator as recommended by manufacturer complete all as specified and directed by Engr-in-charge. Note :- Fuel filter, Lub oil filter, by pass filter, air filter shall be replaced if required under respective items of this Sch under.

5

-

-

... More
Supply only following items of DG Set of any cap upto 125 KVA installed including taking out unserviceable items:- (a) Fan belt.

4

-

-

... More
(b) V Belt,.

3

-

-

... More
(c) Lub oil filter .

4

-

-

... More
(d) Fuel filter element .

4

-

-

... More
(e) By pass oil filter.

3

-

-

... More
(f) Air cleaner, inner element and outer .

3

-

-

... More
Supply and fixing in replacement of maintainance free battery 12 volt 180 AH tubuler type including battery lead and intial charging of battery complete all as specified and directed by engr in charge.

2

-

-

... More
Checking and repair wiring of control panel /AMF Panel incl replace of defective wire and testing complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Supply and fixing in replacement of Over/under voltage Relay 3 phase 415 volts AC complete all as specified and directred by Engineer-in-charge.

3

-

-

... More
Supply and fixing in replacement of Engine starting / stopping Relay 12 / 24 Volt DC complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Supply and fixing in replacement of AC Timer 230 Volts having adjustment 0-60 Second complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Supply and fixing in replacement of DC Timer 12/24 Volts having adjustment 0-60 Second complete all as specified and directred by Engineer-in-charge.

3

-

-

... More
Supply and fixing in replacement of Cranking Relay 12/24 V complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
M/L High pressure pipe as per sample complete all as specified and directred by Engineer-in-charge.

3

-

-

... More
M/L radiator hose pipe as per sample complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Replacement of tripping coil 24 Volts as per sample complete all as specified and directred by Engineer-in-charge.

4

-

-

... More
Material and labour coolant complete all as specified and directred by Engineer-in-charge.

120

-

-

... More
Material and labour Distilled water for battery refilling complete all as specified and directred by Engineer-in-charge.

150

-

-

... More
Taking out LT cable of any size and any no. of cores from trenches and removing for relaying or replacement complete all as specified and directred by Engineer-in-charge.

150

-

-

... More
Relaying of UG cable all as recovered item as above in trenches complete all as specified and directred by Engineer-in-charge.

150

-

-

... More
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 meter long) complete all as specified and directred by Engineer-in-charge.

10

-

-

... More
Supply and fixing poly carbon junction boxes with two no. Busbar of 25 amp capacity alongwith MCB SP 'C' type 6 amp complete with lugs and fixing of cable complete all as specified and directred by Engineer-in-charge.

40

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120.0 sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

90

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95.0 sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

80

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50.0 sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

110

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35.0 sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

140

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

125

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core complete all as specified and directred by Engineer-in-charge.

160

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core complete all as specified and directred by Engineer-in-charge.

260

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directred by Engineer-in-charge.

180

-

-

... More
Sand filling in trenches for cushioning of UG cables as layers of 8cm before laying and 15 cm after laying of cables complete all as specified and directred by Engineer-in-charge.

75

-

-

... More
Sup & lay Sub class 'B' old size well burnt brick laid flat in trenches as protection to cable complete all as specified and directred by Engineer-in-charge.

6

-

-

... More
Material and labour for straight through joints for UG cables 1100 Volts of size 50 to 95 Sq mm 3.5 core complete all as specified and directred by Engineer-in-charge.

4

-

-

... More
Material and labour for straight through joints for UG cables 1100 Volts of size 120 to 185 sqmm 3.5 core complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Earthing complete with copper earth plate electrode 600mm x600mm x 3.15mm thick burried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of the plate not less than 1.25 Mtr below normal ground level connected with 20mm x 3mm copper strip as earthing lead by means of bolts, nuts, check nuts & washers upto DB/Meter board including pit made by PCC 1:2:4 type B-1, RCC cover with suitable handle excavation and earth work in any type of soil, Medium grade GI watering pipe 20mm bore with funnel and wire mesh cmplete all as shown in electrical plate No. 5 of MES schedule 1991 (Part-1) connected to earthing test point all as specified or indicated including testing on complete all as specified and directred by Engineer-in-charge.

3

-

-

... More
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directred by Engineer-in-charge.

4

-

-

... More
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directred by Engineer-in-charge.

2

-

-

... More
Repair of transformer of 100 KVA capacity copper wounded 1 No, step down 11 KV / 440 Volt to any authorised workshop with the following:- (a)Transportation of transformer copper wound 1 No., step down 11 KV / 440 Volt to any authorised workshop to facilitate the repair work. Transformer to be collected from Sub station at Jandwal at Pathankot and back to same site after carrying out the repair work, complete all as specified. (b) Opening the transformer, draining of oil and taking out core of tranformer by disconnecting the same from HT / LT bush rods, opening of core lamination and taking out all the HT coil of the transformer. (c) Rewinding of damaged HT coils with standard copper enamelled conductor including necessary insulating material such as paper insulating, cotton tape sleeves etc varnishing the complete HT coils including newly wound with 'F' class insulating varnish complete all as specified. (d) Assembling of laminations of core after inserting the newly wound coils with other coils and making connections of entire HT / LT limbs complete. (e) Heating the assembled core in oven to desired temperature and testing the same for required insulation result of transfomer.(f) Assembling of transformer after carrying out the repair work and making all HT / LT connections with respective bush rods. (g) Dehydration of transformer oil (drained from transformer) to get dielectric strength not less than 40 KV in 1st tripping with 5mm electrode gap and filling the same in transformer including any oil required to top up the transformer complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
All as per srl item No 112 here in beflore but Transformer of capacity 200 KVA complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Repair to Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 150 KVA complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement MCCB 125 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in replacement MCCB 100 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in replacement MCCB 63 Amp, 16 KA, 4 Pole complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Material and labour for repair of Ceiling Fan 1200 mm sweep including rewinding and replacement of bearing set, if required complete all as specified and directed by Engr-in-Charge.

70

-

-

... More
Material and labour for repair of Exhaust fan any sweep including rewinding and replacement of bearing set, if required complete all as specified and directed by Engr-in-Charge.

25

-

-

... More
Painting of LT pole with recommended colour with paints two coat over a coat of red oxide complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Servicing / Calibration to 11KV HT VCB/(SF-6 type) complete including the following (a) Taking out 11KV HT VCB/(SF6 type) of 400/800 Amps rating trolley from HT Panel after switching off electric supply.Checking of mechanical system for proper functioning of upward/downward movement of HT VCB/(SF6 type) trolley including opening the VCB/(SF6 type) & checking the mechanical system.Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB/(SF6 type) including connection to HT panel complete insulating oil to be replaced where reqd all as directed by EIC. (b)Taking out relay set (2 Nos over current & 01 No earth fault relay) of any make from HT11KV VCB/(SF6 type) panel and cleaning the contact (NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed by EIC (Note for (a) & (b):- (1) Testing of above job to be carried out by engineers of authorised dealer/service centre of concerned OBC (iii) Replacing new items shall be measured and paid separately as supply only . (iv) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer / service centre).

2

-

-

... More
Supply & Fixing shunt trip coil assembly suitable for HT,(SF6 type)/ VCB, operating on 30/110 volt system and testing complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply & Fixing closing/tripping coil operated on 110 /30 volt system suitable for working of relay of HT (SF6 type) / VCB complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing (in replacement) of faulty oil temperature indicator with trip and alarm contacts complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repairs spring charging motor suitable for fixing with 11 KV indoor type VCB panels complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repairs moving contacts of VCB made of copper and suitable for 11 KV VCB Trolley complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fix in repairs Lever type tripping/closing switch suitable for 11 KV VCB Panels complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing Ammeter digital type 100A/5A or 60A/5A CTR of 150mm x 150mm including taking out of old unserviceable ammeter complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing Voltmeter digital type 15 KV of 110 V PTR. Size 150mm x 150mm including taking out old unserviceable Voltmeter complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing power factor meter digital type of 146mm x 146mm including taking out of old unserviceable PF meter complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Material and labour for removal of old paint from the existing VCB panels with the help of wires brush and applying one coat of synthetic enamel paint of the existing tint/colour complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and install HT triple pole 11000 Volts outdoor type gang operated air -break switch suitable for horizontal or vertical mounting on steel frame fixed type with drop out fuse having 12 insulators of rating upto 200 Amp, mechanically operated complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply & Fixing Battery 2 Volt, 100 AH for battery bank installed at sub stations complete with termination clips complete all as specified and directed by Engr-in-Charge.

24

-

-

... More
Comprehensive/preventive maintenance of the following Window / Split ACs/ Water cooler/ Refrigerator/ Deep Freezer of different capacities by carrying out periodical maintenance of equipment including cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/ cooling coils complete and attending complaints complete all as specified and directed by Engr-in-Charge for 1.5/2.0 Ton capacity Split AC

15

-

-

... More
All as per srl item No 135 here in beflore but of 1.5 / 2.0 Ton capacity window type AC complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
All as per srl item No 135 here in beflore but of Water cooler of any capacity complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
All as per srl item No 135 here in beflore but of Refrigerator of any capacity complete all as specified and directed by Engr-in-Charge.

7

-

-

... More
All as per srl item No 135 here in beflore but of Deep Freezer of any capacity complete all as specified and directed by Engr-in-Charge. Note for item No 105 to 109 : (i) Window/Split ACs/ Water cooler / Refrigerator /Deep Freezer shall be taken from department on "as and where installed" basis (ii) Window/ Split ACs are to be maintained for heating as well as cooling mode all as specified and directed. (iii) The contractor shall ensure and assess at the site any initial maintenance required, to make all Window/Split ACs/Water cooler/Refrigerator/Deep Freezer/Desert cooler in fully proper working condition. (iv) After completion of contract, contractor shall hand over all " handed over" Window/Split ACs/Water cooler/Refrigerator/Deep Freezer/Desert cooler in perfect running/functioning condition to the department. (vi) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any breakdown and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect day -to -day complaint of any nature / type. (vii) Penalty for not rectifying the defect in time (within 24 hrs) will be charged to contractor and the amount of penalty @ Rs 1000/- per complaint will be deducted from the due payment of contract. (viii) Complaints will be treated as rectified only after user's "Satisfactory slip" is produced by contractor to concerned JE E/M duly signed by User in Full Name with Rank / Designation and Mobile / Office Telephone No. (ix) Cost of attending day-to-day complaint is included in the rate quoted under this item. No extra payment for attending complaint shall be permissible. (x) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule. (xi) Cost of minor spares i.e. insulation to copper tubes, soldering/brazing, internal wiring to cooling appliances are deemed to be included in the item rate. Items other than mentioned will be measured and paid seperately. Labour required to carryout the maint / repair for all repairs including testing and commissioning shall be deemed to be included in item rate as quoted by the contractor. (xii) Cost of T&P i.e. ladders, tools, brazing, welding, soldering and transportation is deemed to be included in quoted rates

4

-

-

... More
Material and labour for removing the old unserviceable hermatically sealed compressor unit from Water cooler of any capacity and fixing new sealed unit reciprocating type hermatically sealed compressor unit as per sample including charging of gas and oil to at adequate level complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
All as per item above here in before but for 1.5 TR split/window type AC complete all as specified and directed by Engr-In-Charge

10

-

-

... More
All as per item above here in before but for any capacity refrigerator complete all as specified and directed by Engr-In-Charge

1

-

-

... More
All as per item above here in before but for any Deep freezer of capacity complete all as specified and directed by Engr-In-Charge.

2

-

-

... More
Supply only Running capacitor of capacity 30 to 42 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge

12

-

-

... More
Supply only Running capacitor of capacity 45 to 60 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge

8

-

-

... More
Supply only Starting capacitor, 40/60 MFD to 80/100 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge

10

-

-

... More
Supply only Starting capacitor, 100/120 MFD to 120/150 MFD as per existing sample and requirement complete all as specified and directed by Engr-In-Charge

8

-

-

... More
Supply only thermostat switch for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge

6

-

-

... More
Supply only Overload relay for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge

6

-

-

... More
Supply only Starting relay for cooling appliances as per existing sample complete all as specified and directed by Engr-In-Charge

6

-

-

... More
Supply and filling of Gas R-22 for charging to window/Split Air conditioner/Deep freezer and water cooler to maintain adequate gas pressure complete all as specified and directed by Engr-in-Charge.

90

-

-

... More
Supply & fix in replacement single phase preventer (Phase failure relay) suitable for star delta starters, of capacity upto 40 HP with auto, mannual and bypass operation, with time delay setting including wiring and connection with existing star delta starter complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Material and labour for shifting of Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units if required including testing after shifting complete all as specifed and directed by Engr-In-Charge.

3

-

-

... More
Material and labour for servicing of AC plant any type and any capacity up to 12.5TR including, cleaning/descaling of cooling coil, insulation of suction and discharge line, oiling, greasing of blower motor, checking of electrical circuit supply and and replacement of defective filter, relay, capacitor, over load protector etc as required, rewiring and cleaning of condensor coils with Acid/ Scale removal compound for removal of scales deposited in condenser coils using suitable size iron rods/brush/water circulating pump complete all as specified and directed by Engr-in-charge. Note: Acid/Scale removal compound and required T&P should be provided by contractor without any extra cost.

1

-

-

... More
Supply and fixing Filter drier with flared/soldered connection as per sample complete all as specified and directed by Engr-In-Charge.

2

-

-

... More
Supply and fixing in replacement strip heaters 3.0 kilowatt suitable for mounting in AC Plant ducts or as required complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Material and labour for replacement of PVC honey comb fins suitable for cooling Tower of any capacity upto 3x12.5 TR ccomplete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material and labour for replacement of water distribution flaps of cooling tower of AC Plant of any capacity upto 3x12.5 TR as per sample complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material and labour in replacement of air filter of AHU as per sample made of suiable filter with efficiency not less then 90% class 1 to 10 micron, matching with existing sample complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Material and labour for cleaning of Cooling tower of any capacity by draining out water from inside, and including descaling of base tank and sprinkler including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Material and labour for cleaning of base tank of Air cooling plant having blower motor of 15 HP capacity by draining out water from inside and including descaling of tank and water sprinklers including cleaning of complete assembly complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Supply and replace / top up of compressor oil N-68 to AC Plant compressor upto adequate level complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Repair/servicing of air handling unit, cleaning of all duct from A.H.U.to supply air grill and cleaning/descaling of cooling coil, water pressure meter, greasing to bearings and taking out the dust and mud complete all as specified and directed by Engr-In-Charge

1

-

-

... More
Supply and fixing in replacement of LCD display cum operating unit for central AC plant of capacity upto 16.5 TR suitable for starting/stopping, adjustment of temperature, including display of temperature, and fault indications complete matching with existing complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Material and labour for repair of Geyser Assy of capacity 25 / 35 / 50 Ltr including replacement of Geyser element 1.5 KW as per sample, syphen assy incl gasket and NRV complete all as specified and directed by Engr-in-Charge. Note: Geyser Element, Syphen, NRV and Gasket will be measured and paid separately.

30

-

-

... More
Supply and fixing Geyser element 1.5 KW including connections complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply and fixing syphon assy including gasket & NRV complete all as specified and directed by Engr-in-Charge.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.