Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 83,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683053_1Tender No
8939/NIT-53/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
107.13
-
-
Excavation over areas, not exceeding 1.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
70
-
-
Excavation over areas, exceeding 1.5mtr and not exceeding 3mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
40
-
-
Excavation over areas, exceeding 3mtr and not exceeding 4.5mtr deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
40
-
-
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
29
-
-
Material and labour for PCC ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
78.86
-
-
Material and labour for PCC ( 1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
2.6
-
-
Material and labour for PCC ( 1:3:6), type C-1 using 20 mm graded stone aggregate as in post holes, foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
5
-
-
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
117
-
-
Material and labour for brick work in half brick thick wall using burnt clay bricks (sub class 'B' old size burnt clay bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
15
-
-
Material and labour for 40 mm thick damp proof course in cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary form work and including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in- charge. (Note :- WPC shall be measured & paid separately as Supply only)
17
-
-
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
15
-
-
Form work to soffits of suspended slabs such as flat roof slabs, floor slabs, shelf slab, landings and similar work not exceeding 200mm thick (horizontal or sloping) fair finished complete all as specified and as directed by Engineer-in- charge.
60
-
-
Form work to flat sides and soffits of floor or roof beams, beam haunchings , lintels, cantilevers, shelves including supports, overhangs, sides of chajjas etc and similar works fair finished flat surfaces complete all as specified & directed by Engineer-in- charge.
23
-
-
Material and labour for reinforced cement concrete M-25 (Design mix) as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
1
-
-
Material and labour for reinforced cement concrete M-25 (Design mix) as in beams, cantilevers, bressummers., lintels, chajjas, cills, steps; seismic and other similar bands complete all as specified and as directed by Engineer-in-Charge.
(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
1
-
-
Material and labour for reinforced cement concrete (nominal mix) type B-1 (1:2:4) (20 mm graded aggregate) as in beams, cantilevers, bressummers., lintels, chajjas, cills, steps; seismic and other similar bands complete all as specified and as directed by Engineer-in-Charge.
(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
2.3
-
-
Material and labour for reinforced cement concrete M-25 (Design mix) as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge.
(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
3
-
-
Material and labour for reinforced cement concrete (nominal mix) type B-1 (1:2:4) (20 mm graded aggregate) as in slabs supported on walls, beams and columns landing, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer-in-Charge.
(NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
3
-
-
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
1150
-
-
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge.
(NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
100
-
-
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
267
-
-
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
115
-
-
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
20
-
-
Supply only liquid water proofing compound all as specified
1
-
-
Supply only liquid water proofing compound all as specified
16
-
-
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
37
-
-
Material and labour for 50 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
30
-
-
Material and labour for 15 mm thick rendering in CM 1:3 mixing with WPC @ 200 ml per bag of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surface complete all as specified and as directed.(WPC shall be measured separately)
20
-
-
Material and labour for provn of water proofing roof treatment to accessible/Non accessible RCC roof with 3 mm APP modified membrane with non woven polyster reinforced wt not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal insulation with white mineral/ gravel finish on upper side of membrane uniformely embedded during manufacturing process all as per following specifications:
(a) The surface of roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall be cleaned of all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the grove shall be cut around to tuck in the treatment as pipes, chimneystacs etc. and other similar situations to ease up about corners.
(b) Bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm to be applied an prepared surface till the surface is properly impregnated.
(c) APP modified water proofing membrene as specified shall be laid on the primer surface by torch application method as per manufacturers instructions, The overlaps while torching shall be 100 mm in both directions(longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer.
20
-
-
Material and Labour for morrum/red bajri filling in floors or pavings, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
23
-
-
Material and labour for hard core of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
110
-
-
Material and labour for 100mm thick cement concrete ( 1:2:4), type B-1 using 20 mm graded stone aggregate as in sub base of floor complete all as specified and as directed by Engineer-in-charge.
20
-
-
Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed by Engineer-in-charge.
20
-
-
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base of floor complete all as specified and as directed by Engineer-in-charge.
838
-
-
Material and labour for 25mm thick cement concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in sub base of floor for leveling course, surface finished rough to recieved tile/Kota stone/PCC floor work complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Tile/Kota stone/PCC floor work shall be measured and paid separately under appropriate item of this schedule.
20
-
-
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
20
-
-
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
85
-
-
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
2
-
-
Supply & fixing vitreous china wash hand basin oval type under counter, white colour, of size 410mm x 310mm x 220mm excluding pillar taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge.
Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ.
1
-
-
Supply & fixing vitreous china urinal, half stall type, white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling and 32mm dia waste pipe and pointing around urinal back in cement mortar complete all as specified & directed by Engineer-in-charge.
2
-
-
Supply & fixing vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white or black colour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
1
-
-
Supply and fixing 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
50
-
-
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
70
-
-
Cutting chases, pinning in making good to facing where required and pointing in CM 1:3 to edges of landing, steps, cills, sunshades, shelves, lintel etc. and cutting chases for concealed water tubing etc and making good cutting n . exc 10 cm girth complete all as specified and as directed by Engineer-in- charge.
10
-
-
Supply and fixing long body bib tap cast copper alloy fancy type, chromium plated with crutch or butterfly handle with capstan head, wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
10
-
-
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 1000 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including inlet and out let connection and fixing ball valve and gate valve complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
3
-
-
Supply only ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
1
-
-
Supply only gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
1
-
-
Supply and fixing ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 20mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
2
-
-
Supply and fixing gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
2
-
-
Supply and fixing 600mm x 450mm size bevelled edge mirror selected quality 5mm thick glass mounted on 6mm thick commercial ply and fixed to wooden plugs with chromium plated brass screws and cup washers, including aluminium frame / beading alround made of aluminium channel, complete all as specified and directed by Engineer-in-Charge.
8
-
-
Supply and fixing soap dish, vitreous china white/ stainless steel, approximate size 160x160x90 mm complete all as specified and as directed by Engineer-in-charge.
6
-
-
Supply & fixing brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed.
2
-
-
Supply & fixing PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified & directed.
6
-
-
Supply & fixing Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts screwed for iron pipe or for brass ferrule 15mm bore complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of tap shall be as given in SSR or in relevant IS
2
-
-
Supply and fixing chromium plated stop valve/angle valve cast copper alloy, with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
7
-
-
Supply and fixing concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
2
-
-
Supply and fixing hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook complete all as specified and as directed by Engineer-in-charge.
1
-
-
Supply & fixing 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
10
-
-
Supply & fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge.
24
-
-
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
4
-
-
Supply & fixing 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including PCC work, complete all as specified and as directed by Engineer-in- charge.
10
-
-
Supply & fixing PVC (SWR) bends (any radius) suitable for 75mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
5
-
-
Supply & fixing PVC (SWR) vent cowl suitable for 75mm bore PVC pipe complete all as specified and as directed by Engineer-in- charge.
4
-
-
Supply & fixing PVC (SWR) floor trap suitable for 100/110mm bore pipe, plain with CP grating including jointing with solvent cement complete all as specified and as directed by Engineer-in- charge.
4
-
-
Material & Labour for 100 mm dia cast iron floor trap with CP grating including jointing to waste pipe with solvent fixed in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply & fixing PVC (SWR) gully trap 125/110 mm,setting and jointing with solventcement Square or round type P or S trap complete all as specified and directed
1
-
-
Supply & fixing stainless steel grating doom 100 mm dia (min weight 25 gms) complete all as specified and directed
4
-
-
Supply & fixing stack clamps for 110 mm dia pipe made out of 50 mm by 5mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed
4
-
-
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2010 (Part-II), fixed in opening complete all as specified and as directed by Engineer-in-Charge.
9
-
-
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
10
-
-
Material and labour for PCC (1:3:6) type C-0, using 12.5 mm graded aggregated as in back filling of chowkhats and for hold fast complete all as specified and as directed by Engineer-in-Charge
0.15
-
-
Supply and fixing factory made solid core PVC door shutter 30mm thick (stiles) consisting of frame made out of MS tubes of 19mm gauge thickness and size of 19mmx19mm for stiles and for top and bottom rails 15mmx15mm. MS frame shall have a coat of red oxide primer of approved make and shall be covered with heat moulded plain colour PVC sheet, 'C' channel of size 30x50mm forming stiles and 5mm thick wide PVC sheet strip of 20mm width stuck inside with solvent cement for stiles, and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and 10mm (5x2mm) thick, 20mm thick PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive and an additional 5mm thick PVC strips of 20mm width is to be stuck on interior side of C channel using PVC solvent adhesive as per manufacturer's instructions, door to be fixed to frame with and including 3 Nos MS powder coated butt hinges of size 100mm long x 25mm wide and 2mm thick and fixing with 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR-2009 (Part-I, specifications) & shown in relevant drawing of item No. 8080 in SSR-2010 (Part-II, rates). The width of stiles & rails will be in proportion to the width of the door shutter as specified in SSR-2010 (Part-II). complete all as specified and as directed by Engineer-in-Charge.
3
-
-
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
4
-
-
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
4
-
-
Supply & fixing, factory made steel ventilators all as per IS 1038/83, with top hung shutters including hinges, suitable steel handle, steel peg stay, fixing lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
1
-
-
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, with glazing bars including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
6
-
-
Supply & fixing, factory made steel window confirming to IS 1038 with side hung shutters including projecting type hinges, with steel handle, steel peg stay, complete, dovetailed welded, without glazing bars (mosquito proof shutter) including fixing of lugs in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & as directed by Engineer-in- charge.
6
-
-
Supply & fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tack or stainless steel wire staples complete all as specified & directed by Engineer-in- charge
1
-
-
Supply & fixing 3mm thick sheet glass ordinary quality in squares not exceeding 0.5sqm in each pane (for new door/window) and fixed in any type of doors/windows/ventilators with wooden bead/pin tacked/with oil putty etc. as required or as directed including cutting of glass as per site requirement complete all as specified & directed by Engineer-in- charge.
4.8
-
-
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
6.8
-
-
Supply and fixing anodised aluminium handle cast type 125mm long complete all as specified & directed by Engineer-in-charge.
4
-
-
Supply and fixing extruded aluminium alloy handles, fabricated type anodised 150 mm complete all as specified & directed by Engineer-in-charge.
8
-
-
Supply and fixing aluminium anodised barrel tower bolt of extruded section, 200mm long complete all as specified & directed by Engineer-in-charge.
12
-
-
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
2
-
-
Supply & fixing 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply & fixing aluminium anodised sliding door bolts 250mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified & directed by Engineer-in- charge.
2
-
-
Supply and fixing 100mm long stainless steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
6
-
-
Material and labour for precast cement concrete (1:2:4) type B-1(using 20 mm graded stone aggregate) as in landings, cover slabs, precast man hole covers, set in cement mortar (1:6) including use & waste of necessary form work, weathering, slightly rounded or chamfered angles and throating all as specifed and directed.
0.3
-
-
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
50
-
-
Material and labour for 200mm bore (internal dia) reinforced concrete pipes, class NP-2, laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
18
-
-
Material and labour for cement concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in bed of drain pipe of size 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
48
-
-
Material and labour for cement concrete (1:4:8), type D-2 using 40mm graded stone aggregate as in bed of drain pipe of size 200mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
17
-
-
Cutting into existing manhole for connecting new drain pipe of 150 mm bore and making good the pipe and rendering disturbed surface where drain pipe have been inserted cutting out existing benching for foRunning Metering branch channel (1/2 round or 3/4 round as required) in cement concrete 1:2:4 type B1 and finished the surface even and smooth and refoRunning Metering benching as required and directed by Engineer - in - Charge.
3
-
-
Material and labour for PCC type B1 1:2:4 (40mm graded aggregate) as surface channels and draincomplete as specified and directed.
0.25
-
-
Removing excavated material (surplus soil) to a distance exceeding 50 mtr but not exceeding 100 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
268.05
-
-
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
37.58
-
-
Material and labour for antitermite treatment, treating the bottom and sides of excavation at the rate of 5.0 Litres of emulsion per square metre of surface area complete all as specified & directed by Engineer-in- charge.
20
-
-
Material and labour for antitermite treatment, treating the top surface of filled earth at the rate of 5.0 Litres of emulsion per square metre complete all as specified & directed by Engineer-in- charge.
20
-
-
Material and labour for antitermite treatment, treating the soil under plinth protection at the rate of 5.0 Litres of emulsion per square metre complete all as specified & directed by Engineer-in- charge.
15
-
-
Material and labour for preparation of new plastered surfaces on walls and apply two coats of OBD over a coat of wall care putty complete all as specified and directed.
20
-
-
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint over a coat of priming plastered and other surfaces with alkali resistant priming paint by using paint brush complete all as specified and as directed by Engineer-in-Charge.
110
-
-
Material and labour for preparation of newly plastered or unplastered surfaces of ceilings and applying three coat white wash complete all as specified and as directed.
20
-
-
Material and labour for preparation of newly plastered or unplastered surfaces of wall and applying three coat white wash complete all as specified and as directed.
95
-
-
Material and labour for preparation of new decorated surfaces (plastered/unplastered) of walls/pillars /cornices by remove / scraping down all smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc with using broom / steel patti / wire brush / sand papering or by any other mean, upto entire satisfaction of Engineer-in-charge and after preparing the surface smooth applying two coats of weather proof exterior emulsion paint (wheather coat Apex, 100% exterier grade) by using paint roller brush, as per existing or as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
30
-
-
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
917
-
-
Supply & fixing 20 cm x 20 cm x 25 mm thick chequered cement concrete coloured tiles as in floor/path, set, jointed and pointed in neat cement slurry with grey cement and pigment to match the colour of tile, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
20
-
-
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles and the interstices etc complete all as specified and as directed by the Engineer-in-Charge.
22.93
-
-
Supply and fixing sand filling under floor or in foundation including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
20
-
-
Material and labour for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in kerb stone, quoin blocks, copings, kneelers, apex stones, boundary pillars, bed plates, bonders ( for stone walling), etc with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles and throating etc including form work and laying and setting in cement mortar (1:4) including dismantling of old damaged kerb stone and removing the debris from site all as directed.
33.5
-
-
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
3
-
-
Material and labour for Preparation of new or previously treated/ untreated concrete surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint in different tint complete all as specified & directed by Engineer-in- charge.
110
-
-
Material and labour for Preparation of new or previously untreated wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
17
-
-
Material and labour for preparation of new or previously untreated steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
123
-
-
Supply and fixing anodised aluminium snap grid frame work of size of grid 605 x605mm for false ceiling including necessary notching and prepared holes, the snap grid shall consist of anodised aluminium main tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM, cross and Intermediate tee of size 23.5mm x 26.4mm x 1.4mm weighing 0.191 Kg/RM. The main and cross tee shall be jointed at junction with steel screws or MS bolts, nuts and washers, the snap grid (main / cross tee sections) shall be supported at ends all along the wall with anodised aluminium angle of size 35mm x25mmx 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement and duly suspended with 4mm GI wire hangers (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 12mm thick gypsum board in grid fixed in false ceiling grid made of aluminium as per above specifications complete all as specified and as directed by Engineer-in-charge.
60
-
-
Supply & fixing stainless steel sink made out of not less than 1.00mm thick sheet, kitchen or laboratory with plugs, washers, waste pipe including bedding in cement mortar to dwarf wall or fixing with cast iron cantilever brackets and connecting union to waste pipe; overall size 1800mm x 500mm x 350mm complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
300
-
-
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
4
-
-
Supply and fixing 0.63 mm thick galvanised, corrugated mild steel sheeting (having 275 gms zinc coating per sqm of sheet area) with two corrugations side lap, fixed with L- type or J-type or cranked hook bolts and washers, in roof, wall etc complete all as specified and as directed by Engineer-in-charge.
10
-
-
Material and labour for mild steel framed work, framed/truss work made by using hollow square/rectangular/round pipe (ERW or induction butt welded tubes conforming to latest relevant IS), or other section like angle, tee, plate, distance pieces, cleats etc. and cut to shape, drilled and counter sunk for screw, as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and fixed with angle cleats or other connecting plates, gusset plates, brackets, bending and welding, riveting etc, conforming to Gde Fe-410-W (Gde E-250 quality A) complete all as specified and as directed by the Engineer-in-Charge.
Note ;- Sketch of truss design and steel section to be used shall be approved by Engineer-in-charge in writing before execution)
1819
-
-
Material and labour for mild steel work tubular poles/post including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to latest relevant IS grade St-240 complete all as specified & directed by Engineer-in- charge.
732
-
-
Material and labour for machine cut 18 to 22 mm thick, Kota stone slab (size of slab not less than 550x550mm) as in flooring, laid over and including 15 mm thick bedding layer in cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish) and polishing by machine, including machine cutting to make it square or rectangular as per site complete all as specified and as directed by Engineer-in-Charge.
60
-
-
Material and labour for machine cut 18 to 22mm thick, Kota stone slab as in riser of steps, skirting, dado and on pillar, laid over and including 10 mm thick bedding layer in cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing /grinding (mirror finish ) and polishing by machine, including machine cutting to make it square or rectangular complete all as specified and as directed by Engineer-in-Charge.
5
-
-
Supply & fixing 3mm thick, 38mm wide glass dividing strips inserted in position to the required design/ pattern all as specified & directed by Engineer-in- charge
200
-
-
E/M Works
-
-
-
Material & Labour point wiring with 1.5 sqmm single core PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non-metallic PVC conduit (medium grade) surface on wall / ceiling with and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) including modular metal flush box & modular cover plate with frame suitable matching colour of required module for mounting or housing switches, socket outlets, fan regulators, etc. including blanking plates & all other fixing accessories for one light/fan/call bell/exhaust fan point controlled by one 5/6 Amps switch and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and directed.
30
-
-
All as item No 97 here in before but for one socket outlet 5 pin 5/6 Amps 250 Volts flush type on same board complete all as specified & directed
4
-
-
All as item No 97 here in before but for one socket outlet 5 pin 5/6 Amps 250 Volts flush type on Independent board but not below the swtich board complete all as specified and directed
7
-
-
All as item No 97 here in before but for one socket outlet 6 pin, 6/16 Amps, 2 in 1 with cable 2.5 Sqmm multistranded copper conductor FRLSH cable on independent board including provision of 2.5 Sqmm PVC insulated copper conductor FRLSH cable continuos as earth wire connected to earth dolly, conductor etc
4
-
-
Supply and fixing switch 1 way 6A, including its suitable module type, internal plates and frame cover with all connected acessories complete all as specified and directed.
41
-
-
Supply and fixing socket outlet multipurpose, 2 in 1, 5 pin, 5/6 Amps complete all as specified.
6
-
-
Supply and fixing ceiling rose surface type polycarbonate, isolated body two to three terminal, topline series 20 x 50mm, 6 Amps, complete all as specified.
25
-
-
Supply and fixing self ballast LED retrofit lamp with PVC body and PC diffuser 9 watt 230 volt 6500K complete all as specified and directed.
6
-
-
Supply and fixing lamp holder PVC/polycarbonate type with back plate suitable for batten fitting with LED bulb 9W complete all as specified and directed.
6
-
-
S&F new generation energy saving ,wall mounted LED Tube light batten fittings , extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver 20 Watt LED duly fitted on pvc square block 6500K (4' ft long ) with LED rod 20 watt, 230 Volts 50 Hz.
12
-
-
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
9
-
-
Making holes for 300 mm dia exhaust fan of suitable shape & size into or through brick walls at groung/First/Scond floor including plastering for making good to the original surfaces of any description disturbed including painting /distemper matching with the existing colour.
Note : Rates are deems to be including charges of any type of T&P, Insurance of staff deployed at site.
3
-
-
Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet, double door, powder coated DB SPN 12 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete including taking down old unserviceable DB all as specified and directed
1
-
-
Supply and fixing sheet metal enclousers made out of CRCA mild steel sheet, double door, powder coated DB SPN 4 way 240 Volt, 200 Amps rated bus bar, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete including taking down old unserviceable DB all as specified and directed
1
-
-
Supply and fixing MCB SPN 32 Amps, 10 KA, B Curve, 230 V AC,50 Hz including necessary attachment complete all as specified and directed
2
-
-
Supply and fixing MCB SP 6 to 40 Amps 240, 10 KA B curve complete all as specified and directed
12
-
-
Supply and fixing of BLDC (Brushless direct current motor) ceiling fan 5 star rated, complete with blades, down rods, and accessories, 230 Volts, 1200mm sweep, Min air delivery 210 CFM with service value 6.00 BEE, including electrical connection providing twin core round copper conductor cable of suitable size, complete all as specified and as directed by Engineer-in-Charge.
Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account
3
-
-
Supply and fixing of exhaust fan steel body 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account.
1
-
-
Supply, laying & testing in trenches, along poles/ walls LT cable XLPE insulated armoured, heavy duty electric cable, 1100 volts grade, cross sectional area 16 sqmm 2 core from trenches/ along poles/ walls complete all as directed. Note :- Excavation& earth work, sand cushioning and brick protection shall be measured and paid for separately.
110
-
-
Material and labour for sand filling in trenches including watering and consolidation complete all as specified and directed by Engr in charge.
3.24
-
-
Material and labour for sub class "B" brick laid in trenches for cable protection and laid perpendicular to the length of cable.
348
-
-
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%