Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Dec 2023
Closing DateCancelled
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fixing LED flood light 200 watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp in replaceemnt of metal halide flood light hoarding light luminaire complete all accessories, connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed by Engr-in-Charge.

25

-

-

... More
All as per Srl item No 4 above but 120 watt all as directed by Engineer-in-Charge.

30

-

-

... More
All as per Srl item No 4 above but 50 watt all as directed by Engineer-in-Charge.

15

-

-

... More
Supply and fixing high intensity, energy saving, long range 1 Km, manual rotating LED search light for watch tower, 1 x 300 watt, multi circuit, LED efficacy 160 lumen/ watt, LM 6 housing with heat sink, round in shape, dia 430 mm, operating voltage 90V-300V, 50Hz, PF0.95, THD20%, CCT 5500K, CRI70, optics used PMMA/PC lens, narrow beam 7 degree, average lux level at 10metre11000, toughned clear glass with silicon gasket, over volt/ under volt, over heat, SP-10K & short circuit protected , conforming to LM 79 (IS16106:2012), Type tested under 10322.5.5 :2013) and B.I.S certified. The search light shall be completed with manual revolving CS stand D 20 cm x H15 cm (min.) with 3 Nos. foundation holes for mounting of search light on watch tower strcuture, manual rotation of light on horixiontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position, complete all as specified and directed. Make: KALIN, Model No CS-LRFLL-25PC30 or equivalent of makes as per Appx. 'B' as approved by GE.

12

-

-

... More
Supply and fixing in replacement bracket made out of GI pipe light grade 32 mm bore and bent to shape 1.5m long, MS clamps made out of MS flat iron of size 40mm x 5mm thick and drilling of hole for and including nuts, bolts and washers including painting MS clamps with two coats of synthetic enemal paint over a coat of red oxide primer including taking down the existing GI pipe bracket complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement of single phase 5 KW Automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural Light Lux level. Switching on illuminance level should be of minimum 30 Lux and Switching off illuminance should be greater than or equal to 10 Lux. The sensor should also have part night operation facility of min 4 hrs to maximum 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming-outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP54 complete all as directed by Engr-in-Charge.

4

-

-

... More
Taking down old ACSR conductor and Supply, fixing and testing of Aerial bunched (AB) cable LT 1100 volts grade (for street light) of size 1 core x 35 sq mm (phase conductor) + 35 sq mm (bare messenger conductor) constitute of stranded compacted circular aluminium phase conductor insulated with XLPE ( Sioplas) compound and bare messenger stranded circular all aluminium alloy conductor, including all fittings such as anchor clamp, suspension clamp, service clamp and any other fittings including taking down old ACSR conductor complete all as specified and directed. Note : (i) Contractor shall do all kind of tests for LT cable as per IE rule before fixing on ploes including factory test report.

2500

-

-

... More
Supply and fixing black mild steel insulation piercing connector for service connection suitable for 35sq mm AB Cable all as specified and directed.

210

-

-

... More
Repair / tightening of end terminals of street light fitting, flood light, Post top lanten of any size/ capacity at any height and repair the street lights having minor faults i.e loose connections, carbon deposition, shifting and refixing the same etc and make the light functgional all as specified and directed by Engr-in-Charge. Note :- (a) Complaint shall be done within 48 hours after intimation by JE E/M / Engineer-in-Charge failing which penalty of Rs 100/- per day per complaint will be levied on contractor. (b) One supervisor will report to JE E/M / Engineer-in-Charge on daily basis with complaint Register.

800

-

-

... More
Supply and fixing in replacement of 3 pole power contractor of amp rating 25 Amp 3AC and 45amps 1AC as per existing make and rating all as directed by Engineer-in-Charge.

5

-

-

... More
Supply and laying weather proof flat twin core cable aluminium conductor 1100 volts grade size 10sqmm including taking out old one complete all as specified and directed.

400

-

-

... More
Supply & fix LT straight through cable joining kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 3.5/4 core of size 35 sqmm to 50 Sqmm complete all as specified and directed.

6

-

-

... More
Supply & fix LT straight through cable joining kit heat shrinkabale complete with jointing materials suitable for LT armoured cable 3.5/4 core of size 70 sqmm to 120 Sqmm complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacement PVC cable aluminium conductor of size 2.5 sqmm 2 core complete all as specified and directed by Engineer-in-Charge.

700

-

-

... More
S & F in replacement junction box poly corbonate size 200x140x 95mm with glass fibre reinforced , environment friendly, recylable, UV resistant , halogen and silicon free anti acid and anti corrosive IP 66/67 in accordance with IE rule internally embedded gasket, junction box including 3 phase 415 volt aluminium bus bar and din rail for fixing the MCB including one No MCB SP 6A 10KA to control the street light including necessary clamps, nuts bolts to fix the junction box with poles all specified and directed.

55

-

-

... More
M&L for preparation of old painted surfaces of electric pole removing complete dust and other deposited materials by cleaning from steel tubular pole of length upto 9 to 12 metres cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining and repainting existing marking on pole and replacement of reflective band of 3M brand RED -YELLOW-RED alternate coloured 3 numbers of minimum 5 CM in height wrapped all around the pole all as specified and directed by Engineer-in-Charge.

195

-

-

... More
Excavation in trenches in soft/ loose soil n.exc 1.5m wide and n.exc. 1.5m in depth for poles, stay, cable, pipe etc. or for shafts, wells, cesspits, manholes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth including taking out brick for cable protection, sand cushioning and getting out all as specified.

517.5

-

-

... More
All as per Srl item No 20 above but depth exc 1.5m and n. exc 3m all as specified and directed.

0.2

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers each n.exc 25 cm thick in soft/ loose soil all as specified.

265.5

-

-

... More
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.

252

-

-

... More
Supply and lay brick common burnt sub class "B" old size for protection of cable laid in trenches for under ground cable all as specified.

20.7

-

-

... More
M & L for sand cushioning trenches using fine sand to under ground cable, laid in two layers before and after laying cable complete all as specified and directed.

186.3

-

-

... More
Supply, laying,connecting, in replacement XLPE insulated armoured (under ground) heavy duty electic cable with stranded aluminum conductor 1100 volts grade of cross sectional area 16 Sqmm 4 core laid in trenches/ ducts/ through pipes/ in floor/ road/ along the pole including finding out the fault in cable complete all as specified & directed by Engr-in-Charge. Note : Excavation earth work, road cutting, brick for cable protection and sand cushioning shall be measured & paid separately. Only manually excavation will be done at site to avoid damage of cable protection brick and LT cable.

1200

-

-

... More
All as per Srl item No 26 above but 4 core 25 sqmm all as directed by Engineer-in-Charge.

1100

-

-

... More
Supply and fix LT cable sleeves heat shrinkable with colour coding ( Red, Yellow, Blue and Black) suitable for 1100 volt grade 3.5/ 4 core XLPE armoured, aluminium conductor of cable size 50Sqmm complete all as specified and directed by Engineer-in-Charge. (Note :- Sleeves length should not be less than 450 mm each phase/ per side).

400

-

-

... More
M&L for rewinding of Motor capacity 1 HP and other accessories for rotating of light as per sample at site complete all as specified and directed by Engineer-in-Charge.

3

-

-

... More
All as per Srl item No 29 above but motor capacity 1.5 to 2.0 HP.

3

-

-

... More
M&L in replacement of Motor capacity 1.5 HP for hosting and loweing of light from high mast pole as per sample at site complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L in replacement battery 180 AH, 12 Volts 25 plates, lead acid type, maintenance free complete all as specified and directed. Make :- Exide/ Amco/ Amaron/ Standard.

1

-

-

... More
M&L in replacement battery 150 AH, 12 Volts 21 plates, lead acid type maintenance free complete all as specified and directed. Make :- Exide/ Amco/ Amaron/ Standard.

2

-

-

... More
M&L in replacement battery 100 AH, 12 Volts 15 plates, lead acid type maintenance free complete all as specified and directed. Make :- Exide/ Amco/ Amaron/ Standard.

1

-

-

... More
S&F and commissioning of LT outdoor total enclosed/ Lt panel board size 0.75 x 0.50x 0.30 metre approx totaly enclosed made out of 3mm thick CRCA sheet, dust and vermin proof with front opening 440V, 3 phase , 4 wire having 200 amps capacity aluminium bus bar insulated with sleeves, incoming MCCB TPN 63 amps 440 volt 16 Ka -01 No and copper wiring with multistranded cable including timer switch electronic type 01 No with necessary MCBs 6 Amps SP- 09 Nos, contactor and starter 2HP to operate the motor for hoisting and lowering the light to carry the repair including installation of panel with frame pedestal legs made of MS angle of size 40x40x5mm of length 900mm, 450mm below the ground and 450mm above the ground level, grouted in PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) and Provision of wiring from panel to light fitting with 2 Core 4 Sqmm copper conductor cable drawn through PVC rigid/ flexible conduit with necessary fitting etc complete all as specified and directed.

2

-

-

... More
Supply and erecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as pecified type 410 SP-55 (11.0 metres long) including demolition existing pole complete all as specified and directed.

4

-

-

... More
Taking out of faulty LT cable of any size, finding out the fault in cable and relaying, jointing, tesing of serviceable LT cable complete all as specified & directed by Engr-in-Charge. Notes :- (1) Excavation earth work, road cutting, brick for cable protection and sand cushioning and joints shall be measured & paid separately. Only manually excavation will be done at site to avoid damage of cable protection brick and LT cable. If cable damaged during excavation same will be repaired by the contractor without any extra cost to Govt. (2) The fault should be rectified within 2 days of time frame after informed to the contractor/ contractor rep by telephonically/ Whatsapp msg or letter by JE/ Engineer-in-Charge, failing which Rs. 1000/- per day will be levied to the contractor as penalty.

100

-

-

... More
M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggreate as in foundation of pole, stay assembly etc. complete all as specified and directed

0.2

-

-

... More
M&L for PCC 1:3:6 type C-2 using 40mm graded crushed stone aggreate as in foundation of pole, stay assembly etc. complete all as specified and directed

2

-

-

... More
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggreate as in coping of poles including necessary form work and fair finish to exposed surfaces complete all as specified and directed

0.2

-

-

... More
M&L of GI tubing 40mm bore light grade for cable protection fixed along the pole/wall/ under road with nuts, bolts and clamps including taking down existing all as directed.

100

-

-

... More
M&L in replacement for crossarms , bracing, supports, clamps and back plates, fabricated from structural steel section includinng nut bolts washers including welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated in drawings or as directed, inclduing two coasts of aluminium paint over a coat of red oxide and specified .

1

-

-

... More
M&L in replacement of UNSN driver for LED flood light capacity 120 watt for any make all as specified and directed by Engineer-in-Charge.

20

-

-

... More
All as per Srl item No 43 above but capacity 200 watt .

23

-

-

... More
M&L in replacement of metal core printed circuit board (MCPCB) for LED flood light capacity 120 watt for any make all as specified and directed by Engineer- in-Charge

14

-

-

... More
All as per Srl item No 45 above but capacity 200 watt .

12

-

-

... More
A Schedule of Credit for old/unserviceable demolished/dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.