Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 99,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675155_1Tender No
8822/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
BOQ Items
Outgoing
(i) MCCB 200 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC7) FOR control - 01 No
(xi)Extended Rotary handle 350 Amps FP - 01 No
-
-
-
Note:- The Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of AMF Panel outdoor type, 100kva DG Set with alluminium busbar of capacity 250 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 200 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-(PINAKA SHED )
1
-
-
INCOMING from 100 KVA
(i) MCCB 160 Amp thermal megnetic release type FP 25 KA - 01 No (ii) Spreaders 350 Amps FP - 01 Set
(iii) Extended Rotary handle 250 Amps FP - 01 No
(iv) Power Contactor 160 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch 400A for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 160 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 160 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC7) FOR control - 01 No
(xi)Extended Rotary handle 350 Amps FP - 01 No
-
-
-
Note:- The Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of Automatic transfer switch of capacity 40 A four pole type with sheet metal enclusure for DG set of 25KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .(615AD,SHIVAJI,17WEU PUMP HOUSE,HQ 2EW,2FD WKSP,JADUNATH STP ).HAVEELS CAT PART NO IHRFBAE040
6
-
-
S&F in replacement of Automatic transfer switch of capacity 63 A four pole type with sheet metal enclusure for DG set of 40KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .(PET PLATTON,MAP POCKET 5,RANJIT STP,JADUNATH STP ,SHIVAJI SEWAGE PUMP HOUSE).HAVEELS CAT PART NO IHRFBAE063
5
-
-
S&F in replacement of AMF Panel outdoor type, 200kva DG Set with alluminium busbar of capacity 500 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 300 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-( FAD M123)
1
-
-
INCOMING from 200 KVA
(i) MCCB 300 Amp thermal megnetic adjustable type FP 36 KA - 01 No (ii) Spreaders 500 Amps FP - 01 Set
(iii) Extended Rotary handle 500 Amps FP - 01 No
(iv) Power Contactor 300 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 400/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch 400A for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 300 Amp thermal megnetic release type FP 25 KA - 01 No
(ii) Power Contactor 300 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 24V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC7) FOR control - 01 No
(xi)Extended Rotary handle 500 Amps FP - 01 No
-
-
-
Note:- The Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
Material & Labour in repair for Earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32x6 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt around earth plate & 32 mm dia GI pipelight grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified, directed and as shown in plate No. 03 of MES Schedule Part-I. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
NOTE - The quoted rate is deemed to include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm, center to center both ways, funnel with watering pipe.
30
-
-
Repair / maint of unserviceable CANOPY type DG set of capacity 62.5 KVA, 4 cyllinder type make- GREEVES Model No 4G11TAG22, 415 Volts, 50 Hz complete with dismantling of engine head with connected accessories including electrical connections complete with the following spares required as under:-
-
-
-
Supply only of liner complete as per suitable size complete.
4
-
-
Supply only of piston for suitable size.
4
-
-
Repair of tepid valve for suitable size.
4
-
-
Supply only of of piston ring of suitable size.
4
-
-
Supply only of Engine gas kit of suitable size.
1
-
-
Repair of fuel injection assembly in other connected items
1
-
-
Supply only of O RING SET of suitable size.
1
-
-
Calliberation of Fuel injector pump
1
-
-
Calliberation of nosal
4
-
-
Calliberation of delievery valve
4
-
-
Replacement of CR Bearing
4
-
-
labour charge for overhaulling of DG set.
1
-
-
Supply only for dynamo 12 V for DG set
1
-
-
Supply only for water Body
1
-
-
Supply only fan belt
1
-
-
Repair / maint of unserviceable CANOPY type DG set of capacity 40 KVA, 3 cyllinder type make- Mahindra Model No , 415 Volts, 50 Hz complete with dismantling of engine head with connected accessories including electrical connections complete with the following spares required as under:-
-
-
-
Supply only of liner complete as per suitable size complete.
3
-
-
Supply only of piston for suitable size.
3
-
-
Repair of tepid valve for suitable size.
3
-
-
Supply only of of piston ring of suitable size.
3
-
-
Supply only of Engine gas kit of suitable size.
1
-
-
Repair of fuel injection assembly in other connected items
1
-
-
Supply only of O RING SET of suitable size.
1
-
-
Calliberation of Fuel injector pump
1
-
-
Calliberation of nosal
3
-
-
Calliberation of delievery valve
3
-
-
Replacement of CR Bearing
3
-
-
labour charge for overhaulling of DG set.
1
-
-
Supply only for dynamo 12 V for DG set
1
-
-
Supply only for water Body
1
-
-
Supply only fan belt
1
-
-
S&F in replacement of AMF Panel outdoor type, 62.5kva DG Set with alluminium busbar of capacity 200 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of 125 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-(61 WEU QTY 02,EME )
3
-
-
INCOMING from 62.5 KVA
(i) MCCB 100 Amp thermal megnetic release type FP 16 KA - 01 No (ii) Spreaders 200 Amps FP - 01 Set
(iii) Extended Rotary handle 200 Amps FP - 01 No
(iv) Power Contactor 125 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 03 Nos
(vii) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-4, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch 125A for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 100 Amp thermal megnetic release type FP 16 KA - 01 No
(ii) Power Contactor 125 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter 96 x 96 mm with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC7) FOR control - 01 No
(xi)Extended Rotary handle 250 Amps FP - 01 No
-
-
-
Note:- The Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of dynamo of following sizes for DG set canopy type or open type for battery charging including connecting pully and nutbolt as directed.Make For DG set make Cummins ,Mahindra,ashok leyland,Tata,Greeves
-
-
-
12 volts
2
-
-
24 volts
1
-
-
S&F in replacement of Fan belt of DG set of make and type as available on site as directed .Make For DG set make Cummins ,Mahindra,ashok leyland,Tata,Greeves
5
-
-
S&F in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of following sizes as directed by engr-in-charge.
-
-
-
300 sq mm 3.5 core
100
-
-
150 sq mm 3.5 core
260
-
-
95 sq mm 3.5 core
250
-
-
50 sq mm 3.5 core
300
-
-
Taking out of old LT cable of any size as directed
910
-
-
S&F in replacement of water body of DG set of following capacity open / canopy type as directed .Make For DG set make Cummins ,Mahindra,ashok leyland,Tata,Greeves
-
-
-
20 kva to 62.5 KVA
1
-
-
62.5 upto 125 KVA
1
-
-
125 upto 250 KVA
1
-
-
250 upto 400 KVA
1
-
-
Supply & Fixing in repair of Four Pole Contactor 240 AC, 2 NO+NC, or 01 NO NC Make = GE/Schneider/ABB/Legrand/L&T/TC
-
-
-
100 Amp
3
-
-
200 Amp
12
-
-
160 Amps
10
-
-
250 Amps
4
-
-
400 Amps
6
-
-
Supply & Fixing in repair of Four Pole Contactor coil 240 V AC Make = GE/Schneider/ABB/Legrand/L&T/TC
-
-
-
100 Amp
2
-
-
200 Amp
3
-
-
160 Amps
3
-
-
350 Amps
3
-
-
250 Amps
3
-
-
Supply & Fixing in repair of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Type Rectifier Unit etc.
Make = Teknika/ NPP
-
-
-
Battary Charger 12V DC, 10 Amp.
10
-
-
Battary Charger 24V DC, 10 Amp.
5
-
-
Supply & Fixing in repair of Voltage Monitor Relay, 3 Phase AC, 110/415VAC Setting 75-100/300-400V, Trip Time 0-10 Sec. Make =Teknika,L&T,vinilec
3
-
-
Supply & Fixing in repair of Timer AC/DC on Delay, AC 110/220V AC DC 12/24, 1-10, 3-30, 10-100 Sec. Make =Teknika,L&T,vinilec
5
-
-
Replacement of indicating lamp set RYB for phase indication operating 240 volt 50 HZ AC with new one LED panel mounting type complete to match existing one all as directed Make : L&T / C&S / Siemens / ABB
50
-
-
Supply & Fixing in repair of Engine Start Relay, 12 /24 VDC, For Gensets 3 Cranks No & Off 0-30 Sec Each Setable. Make =Teknika,L&T,vinilec
3
-
-
Supply & Fixing in repair of Annunciator Units, Four Fault, 12/24V DC.Make =Teknika,L&T,vinilec
5
-
-
Supply & Fixing in repair of Mushroomhead Push Button, Press to Lock Turn To Release, 2 No. Make = Vaishno
10
-
-
Supply & Fixing in repair of DC Ammeter 96 Sq.mm, Analog, 0-20 Amp. Make = AE,L&T,siemens
5
-
-
Supply & Fixing in repair of DC Voltmeter 96 Sq.mm, Analog, 0-30 V.Make = AE,L&T,siemens
5
-
-
Supply & Fixing in repair of 6x1.5 Sqmm Multistrand Copper Conductor Control Cable for DG Set to AMF Panel.
300
-
-
Supply & Fixing in repair of Single Phase Preventer in AMF Panel. Make =Teknika,L&T,vinilec
5
-
-
Supply & Fixing in repair of 3 Way Selector Switch in AMF Panel.
10
-
-
Supply & Fixing in repair of Self Carbon Bush suitable for DG Set.
10
-
-
Supply & Fixing in repair of DG Set Starting Current Coil 4 ST SWITCH 12/24 V suitable for DG Set.
15
-
-
Supply & Fixing in repair of DC 24V Online Solenoid suitable for DG Set
2
-
-
Supply & Fixing in repair of DC 12V Stop Solenoid suitable for DG Set
2
-
-
Repair/overhauling of self starter i/c replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing complete all as directed for the following capacity :-
-
-
-
12 Volts
2
-
-
24 Volts
2
-
-
Supply and fix in repair of following :
-
-
-
Oil Pressure sensor
10
-
-
Selector switch STOP EMERGENCY
5
-
-
Current Transformer (200/5)
6
-
-
Battery led of 1 RM length
30
-
-
Supply & fixing in repair of AMF Controller(PROCOM UNIT) Model No :- DGC 6 for AMF Panel for 12V and 24 V both supply
15
-
-
Supply & Fixing in repair of DC 12V Solenoid Coil left/right suitable for DG Set
2
-
-
Supply & Fixing in repair of DC 24V Solenoid Coil left/right suitable for DG Set
2
-
-
Supply & Fixing in repair of ELECTRONIC FUEL PUMP including calliberation suitable for DG Set make as per existing on site.
1
-
-
Supply and fixing in repair of AVR for DG set having following capcity.make natonal,kirloskar,cummins,CG all as directed by Engr-in-Charge.
-
-
-
63 KVA
2
-
-
63 KVA to 160KVA.
2
-
-
160 KVA to 250 kva.
2
-
-
250 KVA to 400 kva
1
-
-
Supply and fixing in repair for all type of hose pipe, over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings with length upto 1 rm all as directed by Engineer-in-Charge.
20
-
-
S&F in replacment of glycole based premixed coolent in DG set as directed
800
-
-
S&F in replacement of engine oil grade 15W40 ,kinemetic viscocity @100 deg cel. 13.5 to 15.5 ,Viscocity index min. 135,flash point min 200 deg cel. as directed
630
-
-
S&F in replacement of DG set canopy repair including hinges replacement as existing at site ,welding works as directed
30
-
-
S&F in replacement of battery terminal of lead acid battery in DG set as directed
100
-
-
S&F in replacement of relay card for amf panel as directed
10
-
-
Supply & Fixing in repair of Four Pole MCCB thermal magnetic release type with copper spreader and nut bolts as given below
-
-
-
100 Amp,16KA
3
-
-
200 Amp,25KA
12
-
-
160 Amps,25KA
10
-
-
250 Amps,25 KA
4
-
-
400 Amps,36KA
6
-
-
S&F in replacement of battery distilled water as directed
200
-
-
S&F in replacement of DG set controller kirloskar green KG934V1 /V2 for auto manual operation of DG set as directed
6
-
-
S&F in replacement of DG set controller cummins PSO600 for auto manual operation of DG set as directed
2
-
-