If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 99,750Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Special Repair To Street Light Feeder And Street Light Panel At Patiala And Specialrepair/ Replacement Of Cooling Appliances
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694845_1Tender No
GE(S)/PAT/T-73/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents containing General conditions special conditions and particular specifications
BOQ Items
... More
All as item No. 2 Above but of size 70 Watt complete all as specified and directed.
110
-
-
... More
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
20
-
-
... More
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
20
-
-
... More
Supply and fixing in repair of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2 complete all as specified and directed.
16
-
-
... More
Supply and fix in replacement street light panels analog time switch (with battery back up), 3P Module, 24 hours program, programmable every 15 min, current capacity 16 Amps, suitable for 63/40/32 Amps street light timer, AC 3 phase, 110-240 V AC (1CO) base/ Din 16 pulse digital time switch,complete all as specified and directed.
5
-
-
... More
Supply and fixing PVC insulated copper cable 2.5 sqmm three core multistanded flexible 1100 volts complete all as specified and directed.
500
-
-
... More
S & F as in replacement brackets 1.2 m long made to shape fabricated out of GI pipe Light grade ISI marked 40 mm dia incl provn of socket nipple welded at once end to suit the light fitting and fix to pole including clamps with nuts and bolts of suitable size cutting, drilling and welding its fix to pole and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
60
-
-
... More
Supply and fixing of MCB 6 A to 32 Amps,240 Volts single pole fix in position where directed, complete all as specified and directed.
100
-
-
... More
S&F Single Phase SMC Junction box suitable for mounting on LT RCC pole of 9 mtr long, box having Al 3 Phase busbar 100 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of copper strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable trench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.
75
-
-
... More
Supply and erecting in replacement LT PCC pole 9 Mts long cross sectional area 102 mm x 172 mm at top and 102x279 mm at bottom class 10 complying with requirement of relevent IS and including painting the pole upto 5 feet from ground level with black and yellow alternate strip of 30 CM each with synthetic enamel paint incl removing of broken pole debris complete all as specified and directed. Note:- (i) After commissioning of new pole contractor would liable to connect all the ACSR conductors to the new pole including insulators and cross arms etc inclusive in this unit rate.
(ii) Excavation ,PCC shall be measured and paid separately.
10
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1,5 mtr in depth for laying of cables errecting of pole including getting out in any kind of soil complete all as specified and directed.
600
-
-
... More
All as per item no. 14 as above but exceeding more than 1.5 m in depth complete all as specified and directed.
2
-
-
... More
Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil complete all as specified and directed.
370
-
-
... More
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
280
-
-
... More
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.
NOTE : Only punned sand shall be measured and paid.
200
-
-
... More
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.
16574
-
-
... More
M&L for PCC 1:4:8 TYPE D-2 using 40 mm graded broken crushed stone aggregate as in mass concrete in foundations etc . complete all as specified and directed.
2
-
-
... More
M&L for PCC 1:2:4 type B-2 using 20 mm graded broken stone crushed aggregate as in mass concrete in foundations etc complete all as specified and directed .
2
-
-
... More
Material and labour for PCC 1:3:6 type C-1 using 20 mm graded stone crushed aggregate for coping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified.
6
-
-
... More
Supply,laying, commissioning and testing or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade in duct / trenches for small length for extension/replacement of the defective cable of nominal cross sectional area 10 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed. Note :-(i) Pipes and bricks for protection, mild steel clamp nut and bolts sand cushioning shall be measured and paid separately.
1000
-
-
... More
All as per item No. 23 here-in before but for cable of size 4 core 16 sqmm complete all as specified and directed.
1200
-
-
... More
All as per item No. 23 here-in before but for cable of size 3.5 core 35 sqmm complete all as specified and directed.
175
-
-
... More
All as per item No. 23 here-in before but for cable of size 3.5 core 50 sqmm complete all as specified and directed.
175
-
-
... More
Taking up or down existing steel tubing and connections, 20mm bore complete all as specified and as directed
20
-
-
... More
M&L for Steel water tubing medium grade 20mm bore galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed.
20
-
-
... More
S & F Gun-metal, globe or gate valves 20 mm dia ,with iron wheel head, screwed both ends for iron pipe and fixein position complete in all respect all as specified.
2
-
-
... More
S&F in replacement LED 10 Watt Bolard Light IP-65, height upto 600/700 mm ceramic body in silver/black colour have base E40 type energy saving, environmental friendly with high power LEDs as light source Warm white type including cost of masonary work for fixing/mounting by making sqaure/round PCC platform in the garden duly cement plastering and white wash complete all as specified and directed.
60
-
-
... More
M&L for MCCB, 4 Pole, 160 A, 25 KA for fixing in DB including proper thimble connection,thermal and magnetic release protection complete all as specified and directed.
1
-
-
... More
M&L for MCCB, 4 Pole, 250 A, 25 KA for fixing in DB including proper thimble connection,thermal and magnetic release protection complete all as specified and directed.
1
-
-
... More
M&L for MCCB, 4 Pole, 400 A, 35 KA for fixing in DB including proper thimble connection,thermal and magnetic release protection complete all as specified and directed.
1
-
-
... More
Supply and replacement of installation sign board of size 1.2x1.2 x.0.30 mtr with LED tube light 2 nos prewired made out G I sheet with MS pipe 50 mm grouting (45cm below GL) into ground in PCC (1:2:4 type B-1) height upto 1.50 mtr from ground level and connected to MCB / Street lights for on/off system including necessary pvc aluminium service wire 2 core of 4 sq mm with written name of installation No and name including taking down old /unserviceable sign board of any size complete all as specified and directed.
2
-
-
... More
Supplying, installing,testing and commissioning of factory fabricated CPR: approved, floor mounted LT panel outdoor type of sie-LXBXW-60 cm x 60 cm x 0.45 m made out of CRCA sheet 3.15mm thick duly power coated with siemens grey shadie totaly enclosed dust & vermin proof with both side of panel openable . Bus bars proviced shall be adequately supported on insulstors . Internal wiring shall be done with mult standard copper cable.The bottom of the panei shall contain detachable plate having provision for entry of armoured cable of adequate size with glands. The panel shall be rounted on duly painted MS Angle iron fame 50x50x6 mm stand duly grouted in PCC 1:2:4 type B-1 having a depth of 150mm below ground level complete all as specified and directed and shall be included of the following accessories:-
(A) INCOMING
(a) Aluminium bus bar of capacity 200Amps for 3 phase with neurai -01 job (b) MCCB 100 Amps, 4poles with over load, 25KA 415 Volts with thermal magnetic protection having ics icu 100% thermal adjustable 0.8 to 1.0 in Inclusive of 08nos spreader links as per the CEM-01 Nos. (c) Digital type Voit meter 0-400 Volts square flush type with inbuilt selecter switch -01 no. (d) Digital type Ammeter 0-400 Amps square flush type with inbuilt selector switch-01 no & suitable size for CTs-01 Nos. (e) Indicator lamp LED type, set of three marked red, yellow & biue -01 Sel (B) OUTGOING: (a) MCB SP, 230 Volt, 50 Hz, 6 to 32 A, 10 KA, "B" curve, - 6 Nos.
(b) MCB SPN, 50 Hz, 6 to 32 Amps, 'B' Curve as incommer, 230 volt, 50 23 Hz, 10 KA,- 15 Nos
1
-
-
... More
Supply and fix in replacement electronic driver with power factor correction suitable for 35/45/60 Watt LED street lights, input AC 85-300V, input frequency 50/60 Hz, output voltage DC 22-38V, output current 1500mA (+-) 5%, waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed.
25
-
-
... More
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified and directed.
400
-
-
... More
Supply and fix in replacement electronic driver with power factor correction suitable for 70/90/120 watt LED street lights, input voltage 70V AC to 300 V AC , power factor 0.99 (Unity) , over voltage 300 V cutt off , short and open circuit protection isolated, surge protection up to 10 to 12 Kv, maximum output voltage 55 Kv, maximum current up to 1.5a waterproof level :IP 65, shell material : aluminium with IS 15885, complete all as specified and directed.
24
-
-
... More
M&L in replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm.and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
2
-
-
... More
S & F focus fancy light of capacity 15 watt suitable for focusing of objects made out of stainless steel /aluminium die cast body fixed in position complete in all respect all as specified.
20
-
-
... More
Supply and installation of room window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour (1.5 Ton) BEE 5 star rated complete all as specified and directed.
6
-
-
... More
Supply and installation of Air conditioners of split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 Star rating as per and EER 3.2, electric driven single phase of capacity of 2.0 TR complete all as specified and directed.
3
-
-
... More
Supply and installation , commissioning of water cooler fully stainless steel , electric driven single phase having approx storage capacity of 180 ltrs & nominal cooling capacity of 150 Ltrs per hour complete all as specified and directed.
1
-
-
... More
Supply and installation , commissioning of water cooler fully stainless steel , electric driven single phase having approx storage capacity of 80 ltrs & nominal cooling capacity of 40 Ltrs per hour complete all as specified and directed.
22
-
-
... More
Supply and installation of Refrigerator, electric driven (Single phase),capacity upto 310 Ltrs Frost Free , 5 star Rating complete all as specified and directed.
2
-
-
... More
Supply and installation of Refrigerator, electric driven (Single phase),capacity 195/200 Ltrs Frost Free , 5 star Rating complete all as specified and directed.
1
-
-
... More
Supply and installation of Deep Freezer Single Phase 240 volt, 50 Hz , glass top 320 Litre capacity having single door Robust Construction, Corrosion resistant Pre coated GI Cabinet. Lockable Lid, Refrigerent R-134 complete all as specified and directed.
5
-
-
... More
Supply and installation of Desert cooler steel body(sheet thickness not less than 16 gauge) electric driven,single phase.The cooler complete with fan of dia 18 inch with motor(GE/CG/Almonard make) 1440 rpm single phase with speed control with three position( low /medium/high)motor. And fitted with water proof cooler pump of sufficient pumping height and delivery to keep the filter in moist condition . The cooler shall complete with filter pads fitted with non decaying filter material .The cooler shall be capable for cooling not less than 2250 cubic feet. The cooler shall have nominal air flow capacity of not less than 6000 Cum per hour.The overall dimension of the cooler shall not be less than 600mm width(measured along discharged grill side),900mm height and 600mm in depth. The cooler tank capacity shall be 60 ltrs. The cooler shall be internally prewired and including back filling arrangement and with connecting cord 3x2.5 sqmm copper flexible cable of 2.5 mtrs length fitted with 3 pin moulded plug top(ISI marked) of 5/6Amp complete all as specified and as directed.
8
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2.0 KVA complete all as specified and directed.
13
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3.0 KVA complete all as specified and directed.
2
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and directed.
15
-
-
... More
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece etc complete all as specified and directed. Note:- Rates are deems to be includes the cost for fixing of 4 Nos rawl plug of suitable size (4" to 6 ") nuts and bolts , grouting work in RCC/ Brick wall.
13
-
-
... More
Supply & fixing of water heater storage type electric of capacity 35 ltrs opearting on 240 volt AC 50 Hz with all the safety features such as safety valve , auto cut off, indication lamp . Including grouting 04 nuts & bolts for fixing the geyser including PVC connection complete all as specified & directed.
Note:- Rates are deems to be includes the cost for fixing of 4 Nos rawl plug of suitable size (4" to 6 ") nuts and bolts , grouting work in RCC/ Brick wall.
20
-
-
... More
Supply & fixing of water heater storage type electric of capacity 50 ltrs opearting on 240 volt AC 50 Hz with all the safety features such as safety valve , auto cut off, indication lamp . Including grouting 04 nuts & bolts for fixing the geyser including PVC connection complete all as specified & directed.
Note:- Rates are deems to be includes the cost for fixing of 4 Nos rawl plug of suitable size (4" to 6 ") nuts and bolts , grouting work in RCC/ Brick wall.
2
-
-
... More
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 40A complete all as specified and directed.
9
-
-
... More
M&L for sub main surface wiring with 2 runs of PVC insulated unsheathed copper conductor cable of size 6 Sqmm single core through concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 6 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall complete all as specified and directed. (Note :- Two run of 6 Sqmm copper cable one run of 6 Sqmm copper cable and PVC conduit will be measured as a single length).
50
-
-
... More
M&L for point wiring with FRLS PVC insulated unsheathed multi-stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable 1100 Volt grade drawn in and including rigid non metallic concealed PVC Conduit on wall , surface of ceiling with all fittings, such as tee, bend, elbow, socket etc including pressed steel sunken boxes (Terminal boxes) with earth dolly,duly galvanised, with white shade frame & cover plate of suitable module for modular switch / or sockets including FRLS PVC insulated unsheathed stranded copper conductor 2.5 Sq.mm (nominal area ) single core cable as earth continuity conducter to common earth and connected to earth dolly, complete all as specified and directed.
35
-
-
... More
S&F Switch socket outlet combined 2 in 1 , 3 pin 5 amp and 15 amp modular type, 240 volts complete all as specified and directed.
35
-
-
... More
M&L PVC connection pipe heavy duty ISI marked of 15mm size with PTMT nuts of length 450mm from GI pipe to Geyser complete all as specified and directed.
(Note : PVC connection pipe should be compatible to hot and cold water).
70
-
-
... More
Supply and fix gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia complete all as specified and directed.
31
-
-
... More
M&L for sub main surface wiring with 2 runs of PVC insulated unsheathed copper conductor cable of size 4 Sqmm single core through concealed rigid nonmetallic PVC conduit of suitable size (Not less than 25 mm dia) in wall and surface of ceiling including 4 Sqmm PVC insulated unsheathed copper conductor cable for continuous earthing form main earth dolly including making good the disturbed potion of wall complete all as specified and directed. (Note :- Two run of 4 Sqmm copper cable one run of 4 Sqmm copper cable and PVC conduit will be measured as a single length).
66
-
-
... More
M&L for single pole neutral encloser with a two pin and earth plug and socket complete with one double pole MCB 20 Amp complete all as specified and directed.
8
-
-
... More
S&F Tubes medium grade galvanized with fittings of 15 mm dia such as socket, bend (in any size) laid in trenches complete all as specified and directed.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%