Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688316_1Tender No
GE/PAF-69/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR REPLACEMENT OF LT NETWORK SYSTEM AND CONNECTED ITEMS AT NO 02 AND 03 AREA AT AIR FORCE STATION PATHANKOT
BOQ Items
... More
Sand cushioning to the under ground electric cable complete all as specified and directed by Engineer-in-charge considering 19.75 of SSR part -I
316
-
-
... More
Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engineer-in-charge.
27.5
-
-
... More
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 1.5 meter wide and not exceeding 1.5 meter deep including refilling / with material and , watering well ramming / compacting and making good with PCC 1;2;4,type B-1, 100 mm thick complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
Supply, installation and erection in true vertical position or to be planted as strut steel tubular swaged welded poles complete with MS base plate of 6mm thick of size 300mmx300mm at bottom duly welded and MS pole cap at top, poles shall made out of ERW MS tubing conforming to IS-1161 part-II, type 410 SP -31 (9.0m long) including drilling of holes of required size and Nos for fixing of cross arms/clamps, poles shall be painted internally throughout using anti corrosive black bituminous paint conforming to IS: 158-1968 and externally painted with two coat of red oxide primer and two coats of aluminum paint for expose surface and two coats of black bituminous paint for portion embedded in concrete, painting three black/white bands at lower portion of pole each of 300mm height at 300mm spacing, writing pole no. with black paint in yellow paint circle 10cm dia at suitable height complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.0 mtr long , 0.7 mtr above ground level and 0.30 mtr embedded in PCC blocks of size 0.30x0.30x0.30 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 2 core 10 sq. mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
300
-
-
... More
Supply and lay LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade,of following cross-sectional area 2 core 16 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
350
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core 16 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
200
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 240 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
100
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 core 25 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
350
-
-
... More
PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as mass concrete for path to bus bar/ panels complete all as specified and directed by Engineer-in-charge.
5
-
-
... More
PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching including whethering slightly chamfered angles and finished exposed surfaces even and smooth including necessary form work foundation of bus bars/panels/ two pole structures complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire /Jumper where required all as specfied and directed by Engineer-in-charge.
60
-
-
... More
Dismantling steel pole and deposit to mes store with care for reuse complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Dismantling PCC pole alongwith GOD switch and deposit to MES store with care for reuse complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
S&F for loop type insulator porcelain vitreous white, brown or green large size with overall dimension 90 x 140mm clearance of hole 25.5mm complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 70 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
250
-
-
... More
Supply errect stay assembly complete with accessories as shown in electrical plate No 1 (loop type insulator,stay clamps, excavation and concrete measured and paid separately) dia meter of stay rod is not less than 16mm complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply, fixing, jointing and errecting galvanised stay wire strand of size 7/4 mm complete all as specified and directed by Engineer-in-charge
0.3
-
-
... More
M & L for fixing of line seprator suitable for LT line three conductor in horizontal /vertical feeder complete all as specified and directed by Engineer-in-charge.
30
-
-
... More
M & L for fixing of line seprator suitable for LT line four conductor feeder complete all as specified and directed by Engineer-in-charge.
40
-
-
... More
Supply, fixing, jointing and connecting galvanised wire of size 4 mm including proper binding complete all as specified and directed by Engineer-in-charge
2
-
-
... More
Supply, fixing, jointing and connecting aluminium conductor, steel reinforcement including proper binding complete all as specified and directed by Engineer-in-charge
2
-
-
... More
Supply errection and febrication of cross arms,bracings supports, clamp, and back plates febricated from structural steel section including nuts,bolts,washers welding,bending cold or hot drilling holes for bolts in any shape or size as indicated or complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Taking down the existing defective LT UG cable of size 10 sq mm 2/3/3.5/4 core upto 70 sqmm , 3/3.5/4 core in trenches / pipes / pole for fault finding /attending the repair,and repair the same complete all as specified and directed by Engineer-in-charge.
2200
-
-
... More
All as per items No 31 above but size of 95 sq mm x3.5 core upto 185 x3.5 core sqmm complete all as specified and directed by Engineer-in-charge.
1999
-
-
... More
Supply and fix 63 Amps MCCB bus bar chambers factory febricated suitable for 3 Phase & neutral iron clad with 4 Nos 100 amp rated copper strips including 01 No incomer of MCCB rating 63Amp 4Pole, with two Nos Earthing connection bolt with locking arrangement front door operated complete fixed flush in wall and making good the disturbed wall surfaces complete all as specified and directed by Engineer-in-charge.
45
-
-
... More
Supply and fix shackle type vitreous brown or white insulator including galvanised mild straps, washers insulator,bolts wahsers and nuts of size 100mm height and 115 mm dia suitable for 1100 volts grade complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
Supply, install, connect & testing cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box for 150 amps 3ph and neutral arrangement of size 500mmx500mmx200mm complete weather proof and verminproof conforming to IP-54 made out of 2mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS. It should be mounted on 40 x40 x 6mm angle frame with a clearance of at least 0.45mtrs above GL and 0.30mtrs below ground including required PCC for foundation and coping complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Servicing to Indoor/outdoor type LT panel board single/ double door with canopy by (i) Cleaning with blower, (ii) Cleaning with CTC/Petrol (iii) Replacement of damaged lugsif any (iv) Replacement of deteriorated copper wiring (v) Cleaning and tightening of MCCB terminal connections (vi) Replacement of sheared rubber beadings (vii) Rectifying of loose connections (viii) Replacement of door shutters of suitable size ,with 3.15mm thick CRCA sheet incl locking arrangement , door hinges- 2 nos . (ix) writing feeder name with white paint on all incoming and outgoing feeders including two coats of synthetic enamel paint over a coat of red oxide primer complete with existing colour complete all as specified and directed by Engineer-in-charge.
25
-
-
... More
Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.0 mtr long , 0.7 mtr above ground level and 0.30 mtr embedded in PCC blocks of size 0.30x0.30x0.30 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete with 400 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and MCCB 200 AMP,35 KA, 4 Pole 415 V, complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
S&F in replacment of 3 phase digital multi function meter with suitable accessories and fixing arrangements complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
S&F in replacement of selector switch suitable for 415volts complete all as specified and directed by Engineer-in-charge.
45
-
-
... More
S&F in replacment of voltmeter of range 0 to 500 Volts complete all as specified and directed by Engineer-in-charge.
30
-
-
... More
S&F in replacament of LED type phase indicator to be fitted on panel ( R,Y , B as per site requirement) complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
M & L To find out fault in LT line bring/call fault finding machine equipment and find out fault in any size of LT under ground Cable including disconnecting of cable connection from both side panels/poles and necessary excavation to reach upto cable and making space for cable joint complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
M & L cleaning of area around 2/4 /6 pole structure sub station, power house, pump house under ground sump area by surface excavation not exceeding 30 cm, averaging 15 cm deep and getting out removing shrubs, grass miniplants and other unwanted material, stones etc leveling complete all as specified and directed by Engineer-in-charge.
4000
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade,of following cross-sectional area 3.5 core 95 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
200
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 35 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
500
-
-
... More
Material and labour for dismantling old cable end termination and supply and fixing Cable end termination box heat shrinkable outdoor type suitable for 11KV, 95/120 Sqmm to 185 sqmm, XLPE, 3 Core power cable with aluminium conductor complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fix in repair straight through cable jointing kit 11 KV earthed grade heat shrinkable joint with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95/ 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
M & L for cable jointing kit for 11 KV earthed graded cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engineer-in-charge.
3
-
-
... More
Material and labour for dismantling US 20x3mm copper earthing strip and supply and fixing of earthing strip with 20x3mm copper strip fixed on wall floor pole etc incl drilling holes in any position, connection, nut bolts etc complete all as directed by Engineer - in- charge.
15
-
-
... More
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,160 AmpsICS=100%ICU with breaking capacity 36 KA with all accessories including taking down complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
S & F in replacement of MCCB 3 pole 415 Volt, 50 Hz, 200 Amps ICS=100%ICU with breaking capacity 36 KA adjustable type with all accessories including taking down complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Supply & fix heat srink cable jointing kit for 1.1 KV grade cable for straight through joint/ end joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured AIuminium Conductor cable of size 16 sqmm to 35 sq mm complete all as specified and directed by Engineer-in-charge.
25
-
-
... More
All as per items no 51 above bu size of 50 sqmm to 95 sq mm complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
All as per items no 51 above bu size of 120 sqmm to 185 sq mm complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
All as per items no 51 above bu size of 240 sqmm to 300 sq mm complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply Installing testing & commissioning of street Light Pole Box two no Aluminium Bus Bar of capacity 63 amp including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using and nuts & bolts of required size complete all as specified and directed by Engineer-in-charge.
35
-
-
... More
Supply and fixing of GI pipe medium grade, size of 40 mm dia for road crossing / on wall / on pole for cable protection complete all as specified and directed by Engineer-in-charge.
80
-
-
... More
All as per items no 53 above bu size of 50 mm complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
All as per items no 53 above bu size of 80 mm complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
All as per items no 53 above bu size of 100 mm complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Material and labour for dismantling US 25x3mm earthing strip and supply and fixing of earthing strip with 25x3mm aluminium strip fixed on wall floor pole for earthing of GOD, lightning arrestor etc including drilling holes in any position, connection, nut bolts etc complete all as specified and directed by Engineer-in-charge.
45
-
-
... More
Scraping of old paint from the street light steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of alumn paint complete all as specified and directed by Engineer-in-charge.
40
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade,cross-sectional area 3.5 core 120 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
80
-
-
... More
M&L for earth testing, identifying the earthings in system and recording the results on indicator board and producing three copies of test sheet duly signed by Contractor/ JE/ AGE E/M all as directed by Eng-in-charge.
Note :- (i) Cost of labour and tools required for testing is deemed to be included in quoted rates complete all as specified and directed by Engineer-in-charge.
40
-
-
... More
Dismantling the existing earth strip & Relaying of G.I. earth strip 32x6mm and fixing properly with clamps nut bolts complete all as specified and directed by Engineer-in-charge.
80
-
-
... More
M&L in repairs of GI funnels with wire mesh for earthing complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Painting of street light PCC pole without removing accessories with one coat of alternative yellow and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.e clamps GI bracket etc by applying one coat of alumn paint complete all as specified and directed by Engineer-in-charge.
55
-
-
... More
Writing No of pole with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm complete all as specified and directed by Engineer-in-charge.
250
-
-
... More
Supply and fix in replacement of 2 runs of 2.5 Sqmm PVC insulated stranded copper cable for connection of street light including PVC conduit 20 mm external dia medium grade fixed on pole with proper clamping, saddling etc complete all as specified and directed by Engineer-in-charge.
270
-
-
... More
Supply & fixing in replacement copper multi stranded FRLS cable PVC insulated and PVC sheathed flexible size 6 Sqmm single core complete all as specified and directed by Engineer-in-charge. (Cable shall be in suitable length as per site requirement).
180
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 185 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
500
-
-
... More
M & L for PVC insulated sheathed aluminium stranded conductor cable of size 6 sqmm twin core fixed / hang properly at directed location by using suitable mounting / fixing arrangements viz PVC clamps/saddles,connecting complete all as specified and directed by Engineer-in-charge.
360
-
-
... More
M & L for PVC insulated sheathed aluminium stranded conductor cable of size 10 sqmm twin core fixed / hang properly at directed location by using suitable mounting / fixing arrangements viz PVC clamps/saddles, connecting complete all as specified and directed by Engineer-in-charge.
360
-
-
... More
Supply and laying LT XLPE insulated, armoured,heavy duty under ground electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 3.5 core 50 sq mm including cable lugs, jointing materials etc., laid in trenches fixed on poles/duct/wall and laid through suitable GI pipes with proper saddling with clamp complete all as specified and directed by Engineer-in-charge.
250
-
-
... More
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,63 to 100 Amps ICS=100%ICU with breaking capacity 16 KA fixed type complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps ICS=100%ICU with breaking capacity 16 KA ,with all accessories including taking down complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Supply & fix pressure die-cast aluminium IP 65 cool white road way luminaire with LED as Light source with rating not less than 72 Watt including with suitable GI Pipe Bracket , double clamps complete with nut bolts with pole and 2.5 sqmm 3 core copper wire multistrand for connection from DB to Light complete all as specified and directed by Engineer-in-charge.
5
-
-
... More
S & F in replacement of MCCB 3 pole 415 Volt, 50 Hz, 250 Amps ICS=100%ICU with breaking capacity 36 KA adjustable type with all accessories including taking down complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Material and labour for dismantling US 32x6mm earthing strip and supply and fixing of earthing strip with 32x6mm GI strip fixed on wall floor pole for earthing of GOD, lightning arrestor etc incl drilling holes in any position, connection, nut bolts etc complete all as specified and directed by Engineer-in-charge.
68
-
-
... More
Cutting / Tiriming of Tree branches which are touching to HT / LT over head lines and clearing the same up to 4 meter radius for span length not exceeding 45 to 55 meter complete all as specified and as directed by Engineer - in - Charge. (Note: Each span of 30-55 Mtrs will be considered as one length of span for payment purpose) and Any damage cause due to contractormen will be rectified without any extra payment
160
-
-
... More
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron lead of 4 mm diasize by means of bolts ,nuts,check nuts and washers of galvanised iron and 4 mm GI wire procted by provision of GI light grade pipe 15 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI wire upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Earthing complete with galvanised steel earth plate electrode 600x600x6mm burried directly in ground not less than 2.25 mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts,check nuts and washers of galvanised iron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip upto main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed . On testing after completion if the desired resistenance is not obtained the contrator shall redo the earthing without any extra cost to the department complete all as specified and directed by Engineer-in-charge.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%