Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date5 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 6,92,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Perform site survey and prepare design proposal for deciding the capacity and treatment technology to be adopted amongst prevailing technologies Soil Bearing Capacity: 18.36 TON/sqm at 2 meter depth. However the contractor shall conduct his own soil investigation and design various civil structures accordingly. Average flow- 900 m3 /day Peak duration 3 hr

-

-

-

... More
Influent (Raw) sewage parameter (At SPS No 5, located just prior to proposed STP):- (a) pH - 7.17 (b) COD - 391.4 mg/L (c) BOD - 202 mg/L (d) TSS - 208 mg/L (e) TDS - 818mg/l (f) Oil & Grease - 12.9 mg/l (g) Turbidity - 208 NTU (h) Residual Free Chlorine - 0.1mg/l (j) Total Kjeldahal Nitrogen - 51.27 mg/L (k) Total Phosphorus - 7.16 mg/L (l) Binitrate (as NO2) - 4.06 mg/l (m) Fecal Coliform 900 MPN/100 (n) Odour - Objectionable (o) Helminth Eggs- Absent (p) Color - Slightly Yellow However the contractor shall get the raw sewage tested by collecting the samples as per CPEEHO Manual Sewarage and sewage disposal 2013, in NABL Approved Lab/ Govt Lab.

-

-

-

... More
Effluent (Treated) Sewage Parameter:- (a) pH - 6.5-8.3 (b) COD 50 mg/L (c) BOD 10 mg/L (d) TSS 10 mg/L (e) Total Nitrogen - 10 mg/L (f) Total Phosphorus - 1 mg/L (g) Fecal Coliform - Nil (h) Odour - No foul odour Besides the contractor shall ensure that the Effluent parameters must comply with the quality of treated water parameter for disposal or reuse guidelines issued by various State government and Central government agencies time to time. If they are more stringent than the ones given above.

-

-

-

... More
End usage/reuse of treated wastewater- Arboriculture

-

-

-

... More
Sewage Treatment Plant:- The STP shall consist of 1. Primary treatment consisting of a) Stilling chamber- With hydrolic retention time of minimum 60 second. b) Screen- Shall consist of Medium/Coarse screen(made of SS-316) with mechanical/manual cleaning, c) Oil and greese trap and Grit removal chamber. 2.Secondary treatment process for reduction of BOD and COD (Using biological process designed for 24 hrs operational cycle),Total nitrogen and total phosphorus. Hydraulic retention time in the biological process reactor must be between 1 to 4 hours and adequate aeration as per process requirement shall be provided. 3.Tertiary treatment using multigrade filters and activated carbon filters for ensuring desired output treated water parameters are achieved. The tertiary treatment shall be designed to work atleast 12 hrs per day. 4.SCADA : For continuous monitoring of raw sewage, treated water along with water level, flow rate and remote monitoring and operation of booster pumps for pumping raw sewage and treated water.

-

-

-

... More
Note: 1. The bidder shall submit proposal for more than 1 technology that shall be used while designing STP for approval by accepting officer on the basis of life-cycle cost, footprint of STP. 2. No tank shall be designed to hold wastewater/ treated water for more than 8 hrs at any stage.

-

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for first two years (during Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

24

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for first year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for second year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for third year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for fourth year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for fifth year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for sixth year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for seventh year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Maning, Operation and complete maintenance of STP plant of 0.9 MLD capacity and adjacent sewage pump house for eighth year (after Defect Liablity Period) with and including all items/ equipment as mentioned in items here in above (testing 02 samples per month) to ensure designed parameters of treated water and timely and smooth operation of all equipment and items, every day by employing 03 operators in three shifts (one operator in one shift) round the clock complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
Notes for Ser Item Nos 4.00 to 12.00 (a) Contractor shall arrange biometric attendance machine at installation and payment to workmen shall only be made on the basis of biometric attendance. (b) Reliever for weekly off shall be provided by the contractor at his own cost and rates for the same shall be deemed to included in the quoted rates. No extra payment shall be admissible on this account. (c) All types of T&P required for day to day requirement shall be provided by contractor. (d) All types of transportation if required for handling materials/equipment etc shall be provided by contractor. (e) All types of fire equipment provided in all the installations shall be maintained and operated properly. (f) All electrical fittings and fixtures to be maintained and contractor shall be maintained for any damage. (g) All types of water tanks including flushing tanks shall be maintained.

-

-

-

... More
Notes for Ser Item Nos 4.00 to 12.00 (h) All installations to be kept neat and clean all the time, security of assets shall be ensured and security checks to be carried out daily. (j) In case of any damage, misuse, mishandling, theft of govt property, contractor shall be responsible for the same. (k) All safety equipment such as breathing appratus, safety belt, air hose respiratory, portable lighting equipment, driver suit etc for working in hazardous conditions to be provided by contractor. (l) First aid box with basic medicines to be kept in main installations by the contractor. (m) Misuse of electricity and water shall be penalised and effective recovery shall be made by the department. (n) Manning and operation shall start as per the stipulated date in work order. (o) Proper disposal of material of residual dry waste /other waste material shall be arried out by the contractor all as directed by Engineer- in - Charge. The cost of the same id deemed to be included in quoted rates.

-

-

-

... More
Notes for Ser Item Nos 4.00 to 12.00 (p) Wages to be paied to the empoyees through individual bank accountsonly duly AADHAR linked (i.e. payment through cheque, NEFT, RTGS) and documentary proof of the payment of wages shall be submitted to the department for releasing of contractor's payment. (q) minimum ITI or any other higher qualification with 02 years experience certificate for Operator and two year experience certificate for helper employed shall be submitted to the department. (r) The rate quoted shall be deemed to included for providing stationery for all the installations. (s) Group Insurance, ESI and EPF shall be provided by the contractor for his staff/tradesmen and documentary proof of the same shall be submitted to the department for releasing of payment. (t) In case of abscence of any workmen/operator etc, double the rate quoted shall be recovered as penalty from the contractor's due.

-

-

-

... More
Subtotal

-

-

-

... More
Sch 'A' Section- II, INTERNAL ELECTRIFICATION WORKS

-

-

-

... More
Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 1.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) including fixing of switch/socket/regulator etc complete all as specified and as directed by Engineer-in-charge. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

16

-

-

... More
All as per above Srl item No. 15 but for one socket outlet 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

2

-

-

... More
All as per above Srl item No. 15 but for one socket outlet 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

2

-

-

... More
Material and labour for concealed Point wiring for one socket outlet 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).

2

-

-

... More
Supply only piano switch 5/6Amps, piano flush type, single pole, one way 230 V AC complete all as specified and as directed by Engineer-in-charge.

20

-

-

... More
Supply only piano switch 15/16Amps, piano flush type, single pole, one way 230 V AC complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply only Socket outlet two in one, 5/6 pin 5 Amp, 230 V AC supply, fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by Engineer-in-charge.

4

-

-

... More
Supply only Socket outlet two in one, 5/6 pin 15/16 Amp, 230 V AC supply, fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and as directed by Engineer-in-charge.

2

-

-

... More
Supply and fixing LED tube light fitting T-8 retro polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable of size 23/0.0076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K (l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) (n) CRCA pre coated housing with two coloured plastic end cap and integrated electronic driver

4

-

-

... More
Supply and fixing LED lamp 05 star rated 09 watt LED B-22 Base, including electric connection with using 2 core flexible copper conductor cable of size 23/0.0076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6500K (l) CRI : more than 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

2

-

-

... More
Supply and fixing energy efficient LED security light fitting of 30 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/roadway luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

4

-

-

... More
Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp, ISI Marked complete all as specified and as directed by Engineer-in-charge.

14

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, as per IEC 61439-3, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.

2

-

-

... More
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge

4

-

-

... More
Supply and fixing MCB ‘C’ curve suitable for 240 volts AC supply, 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge

2

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

2

-

-

... More
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified and as directed by Engr-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

2

-

-

... More
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.

1

-

-

... More
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 450mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 12mm dia 200mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.

3

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)

1

4341

-

... More
Sch 'A' Sec - III (Part-II), INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Supply and fixing health faucet fancy type, CP including 1.25 meter long 8mm dia flexible SS tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
Supply and fixing Two way, Angle cock with flange, suitable for 15 mm bore pipe cast copper alloy CP with crutch or butter fly handle screwed both ends for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-charge.

1

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “ROAD, PATH, CULVERT WORKS) " as listed in Schedule ‘A’ Section -IV (Part-I)

1

3722822

-

... More
Sch 'A' Sec - IV (Part-II), ROAD, PATH, CULVERT WORKS

-

-

-

... More
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted using grey cement and no pigment, any shape hexagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed by Engineer-in-Charge Note:- Tiles shall be approved by GE before incorporation in the work.

255

-

-

... More
Supply and laying/fixing factory made precast kerb stones in PCC 1:2:4 type B-1 including chamfers, weatherings, throatings etc in smooth finish & set in cement mortar 1:4 including necessary excavation and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed .

50

-

-

... More
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed by Engineer-in-Charge

147

-

-

... More
Material and labour for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate), in bed to drain pipes of dia 600 mm including packing under, and haunching against the sides of pipes after they are laid and tested; in complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS)" as listed in Schedule ‘A’ Section -V (Part-I)

1

293475

-

... More
Sch 'A' Sec - V (Part-II), AREA DRAINAGE WORKS

-

-

-

... More
Material and labour for Pre-cast factory made RCC drain of size and shape as directed by GE alongwith male and female ends for proper joining, made of 75mm thick RCC M-30 using 20mm graded aggregate, duly embeded two Nos socket for hoisting including form work etc, hosting and placing at site and jointed in CM (1:4) to form uniform length and fair finish to drain upto 80cm girth (width measured @ Avg of inner and outer girth) complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under respective item of Sch.

24.75

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “SEWAGE LINE, SEWAGE PRESSURE PIPE LINE, PUMPS AND TREATED WATER RE-USE SYSTEM" as listed in Schedule ‘A’ Section - VI (Part-I)

1

1948487

-

... More
Sch 'A' Sec - VI (Part-II), SEWAGE LINE, SEWAGE PRESSURE PIPE LINE, PUMPS AND TREATED WATER RE-USE SYSTEM

-

-

-

... More
Supply and laying DWCPE (SN8) drain pipes 200/175mm (OD/ID) dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch

60

-

-

... More
Supply and laying DWCPE (SN8) drain pipes 300/260mm (OD/ID) dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.

350

-

-

... More
Supply and fixing Mild steel bars of TMT CRS 10mm dia and over, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.

365

-

-

... More
Supply and fixing Mild steel bars of TMT CRS 6 to 8 mm dia, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.

1150

-

-

... More
Supply, installation, testing & commissioning non clog sewage submersible pump with chrome steel impeller and cutter, non-clog to pass 35mm size particles having discharge capacity 2300 LPM at 15 mtr head, motor of suitable capacity, 415 volts complete all as specified (for SPS 4) The work also includes the followings:- (a) Pump set capable of delivering 2300 liters per minute at 15 mtr head of make Kriloskar Brother or Equivalent of Mather& platt/ KSB. (b) MS delivery pipe heavy grade not less than 100 mm bore with fittings and suitable length (not not less than 6 mtr) and tapper connection pieces etc

2

-

-

... More
Supply, installation, testing & commissioning non clog sewage submersible pump with chrome steel impeller and cutter, non-clog to pass 35mm size particles having discharge capacity Approx 2800 LPM at 12 mtr head, motor of suitable capacity, 415 volts complete all as specified (for SPS 5 & 6) The work also includes the followings:- (a) Pump set capable of delivering 2800 liters per minute at 12 mtr head of make Kriloskar Brother or Equivalent of Mather& platt/ KSB. (b) MS delivery pipe heavy grade not less than 100 mm bore with fittings and suitable length (not not less than 6 mtr) and tapper connection pieces etc

4

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 200mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

600

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 250mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

400

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

1050

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 100mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed by Engineer-in-Charge. Note : (i)Earth work, DI specials/ fittings shall be measured and paid separetly however cost of joining is included in overall cost quoted by the contractor. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

450

-

-

... More
Supply and fixing cast iron sluice valve 250 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Supply and fixing cast iron sluice valve 200 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Supply and fixing cast iron non-return valve 250 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:5312, CI disc, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Supply and fixing cast iron non-return valve 200 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:5312, CI disc, complete including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing CI/DI fitting upto 250 mm bore pipe line, any type, for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed by Engineer-in-Charge. Note:- Make of CI/DI fittings shall be same make as CI/DI pipe or as per recommendation of CI/DI pipe manufacturer.

700

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

8

-

-

... More
Material and labour for drilling/boring of holes under main road pavement, hard standing or any other situation by manual mean/trenchless technology for accommodate up to 250mm bore DI pipe in the drilled holes, including returning, filling in the end working space including removal of surplus soil and making good the surface complete all as specified and as directed. Note ; (DI shall be measured and paid separately)

15

-

-

... More
Supply and fixing chain pulley block system of capacity 1 ton, 10 meter chain, chain size 6 x 18 mm including Suitable G.I pipes for fixing at sewage sumps & fitting complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
Supply & fixing cast iron double end flanged and drilled non return valve conforming to IS - 5312 suitable for 150 mm bore pipes complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply, install, testing and commissioning of manufacturer's factory assembled and tested electric driven centrifugal pump set of capable of delivering approx 1125 LPM at 34 mtr head comprising of horizontal spilit casing with self priming pump multi stage CI body with impellers operating at 3000 RPM coupled through a tyre coupling to a electric motor 3000 RPM and suitable capacity complete with starter,suction and delivery size 100mmx100mm and mounted on common MS base frame and foundations of the pump sets including PCC foundations, MS bolts with nuts and anti vibration pads complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 1050 X1050 X1050 mm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

2

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 900 X900 X900 mm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

1

-

-

... More
Supply and fix Cast iron foot valve of size 150 mm (6'), conforming to IS 4038 complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply, install, testing and commissioning of manufacturer's factory assembled and tested electric driven centrifugal pump set of capable of delivering approx 165 LPM at 10 to12 mtr head comprising self priming pump multi stage CI body with impellers operating at 3000 RPM suction and delivery size 25mmx20mm and mounted on common MS base frame and foundations of the pump sets including PCC foundations, MS bolts with nuts and anti vibration pads complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “SECURITY FENCING, COMPOUND WALL AND GATE WORKS" as listed in Schedule ‘A’ Section - VII (Part-I)

1

684895

-

... More
Schedule ‘A’ Section - VII (Part-II) (Part-II), SECURITY FENCING, COMPOUND WALL AND GATE WORKS

-

-

-

... More
Supply and fixing Mild steel bars of TMT CRS 10mm dia and over, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.

188.34

-

-

... More
Supply and fixing Mild steel bars of TMT CRS 6 to 8 mm dia, cut to length bent to Shape required incl cranking, bending spirally for hooping for columns, tie bars/dowel bars in longitudinal joints/transverse joints etc, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.

16.35

-

-

... More
Supply and fixing Mild steel bars of TMT CRS 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length bent to Shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge.

79.04

-

-

... More
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section-VIII

1

42218

-

... More
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION AND DG SET WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)

1

583204

-

... More
Sch 'A' Sec - IX (Part-II), EXTERNAL ELECTRIFICATION AND DG SET WORKS

-

-

-

... More
Supply and fix , testing , commissioning of LT weather proof panel board powder coated E64 outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar 400 Amp, chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital Am-meter, digital Volt-meter, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron complete all as directed by Engineer-in-charge comprising of following accessories (Main Panel at STP) :-

1

-

-

... More
(a) Aluminium bus bar capacity 400 Amps for Phase-R-Y-B- & neutral (b) MCCB FP 250 Amps 36 KA, 415 Volt & 50hZ- 1 No (I/C) Outgoing :- (c) MCCB FP 25 KA 125 Amps -02 Nos (for STP Panel & Area Drainage) (f) MCCB, FP 16 kA, 32A, 415 Volts - 01 No (for SPS 5 Panel) (g) Digital ammeter 0-400 Amps of size 96x96 sq mm with selector switch complete with suitable size CTs- 1 No. (h) Digital voltmeter of size 96x96 sq mm with selector switch complete with suitable size CT's - 1 No. (i) LED indicator lamp R,Y,B (1 set of three)

-

-

-

... More
Supply and fix , testing , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital Am-meter, digital Volt-meter, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron complete all as directed by Engineer-in-charge comprising of following accessories (STP LT Panel):- a) Aluminium bus bar capacity 200 Amps for Phase-R-Y-B- & neutral

1

-

-

... More
INCOMING (a) MCCB FP 125 Amps 25 KA - 01 No OUTGOING (b) MCCB FP, 16kA, 32A, 415 V - Treated Water Panel (c) MCB TP, 16A, 415 Volts 10 kA - 04 Nos, for Raw Sewage Pump & filter feed pump (d) MCCB TP 63 Amps 25 kA - 02 Nos For Air Blowers e) MCB DP, 6A, 230 Volts 10 kA- 02 Nos, for Anoxic Mixer, Chlorine Dosing f) MCB TP, 10A, 415 Volts 10 kA-02 Nos, (for Sludge Recirculation Pump) h) MCB, DP 10 kA, 10A, 230 Volts - 02 Nos (for Building lights, Security light) i) MCB TP, 6A, 415 Volts 10 kA- 02 Nos, for Sludge Feed Pump j) Digital ammeter 0-400 Amps of size 96x96 sqmm with selector switch complete with suitable size CTs- 1 No. k) Digital voltmeter of size 96x96 sqmm with selector switch complete with suitable size CT's - 1 No. l) LED indicator lamp R,Y,B (1 set of three) m) Star Delta Starter Three Phase suitable for 5 Hp for raw sewage pump- 02 Nos. n) Star Delta Starter Three Phase suitable for 10 HP for Filter Feed Pump- 02 Nos o) Star Delta Starter Three Phase suitable for 30 HP for air blower- 02 Nos

-

-

-

... More
Supply and fix , testing , commissioning of LT weather proof panel board powder coated outdoor type double door shutter, made out of CRCA 3.15 mm thick outer and 1.6 mm thick for inner door confirming to IS 8623 with angle iron 50x50x6 mm outdoor, floor mounting type with closed bus bar , chamber and with aluminium bus bar with necessary insulators suitable for 3 phase, 4 wire 50 Hz AC supply as per CPRI approved including provn of digital Am-meter, digital Volt-meter, CT's of suitable ratio,indicator lamps R-Y-B, selector switches and internal wiring including making PCC block type 0.6 Mtr above ground level grouting etc all as specified and directed with the following work also includes provision of suitable size of cable glands, cable lugs, nut, bolts, washers etc . The bottom portion of enclosure shall be minimum 60 cm above ground level of legs of angle iron complete all as directed by Engineer-in-charge comprising of following accessories (Treated Water Panel):- a) Aluminium bus bar capacity 60 Amps for Phase-R-Y-B- & neutral

1

-

-

... More
INCOMING (a) 4P MCCB, 25 kA, 32A, 415 Volts - 01 No (b) 1 set of Phase indicating lamp with MCB OUTGOING (c) TP MCB, 10 kA, 25A, 415 Volts - 02 Nos for Pump (d) MCB DB 10 A, 230 V - 01 No (e) Nature switch for automatic switching of street light based on LUX level of natural light of sensor (nature switch) along with suitable power contactors and MCB's (input-output) should be enclosed in panel/wall mountable enclosure made of rust proof, box confirming to IP-54 and it should be able to take Single Phase load of 01 KW (f) Digital ammeter 0-400 Amps of size 96x96 sqmm with selector switch complete with suitable size CTs- 1 No. (g) Digital voltmeter of size 96x96 sqmm with selector switch complete with suitable size CT's - 1 No. (h) LED indicator lamp R,Y,B (1 set of three) (i) Star delta starter suitable for 3 phase 15 HP motor - 02 Nos

-

-

-

... More
Supply, install, testing & commissioning of PLC (Programmable Logic controller) based control panel for automatic pump control/ protection suitable for Fully Automatic Star Delta Starter With VFD of pump with discharge 2300 LPM & 15 meter head (with all accessories) 02 Nos and conductive level sensor - 06 Nos . The control panel shall perform the following functions:- i) automatic pump on/ off (Level based) ii) Phase failure/ phase reversal and motor overload alarm iii) Automatic toggling of pump motors iv) Manual mode operation of the entire system. v) Sewage water high level and low level indication Panel shall be floor mounted of the size (min) 1500H mm x 1200W mm x 500D mm made of CRCA sheet 3.15 mm thick for outer side and 2 mm thick for inner compartment with pretreated phosphots ( 7 tank processed) duly painted powdered coated RAL 7032 totally enclosed dust proof with openable shutter/ door in the front side, outdoor type double door complete with all connections incoming / out going complete all as directed by Engineer-in-charge. comprising of following accessories :-

1

-

-

... More
a) PLC (Programmable logic controller - ) comprising of input/ output modules b) Selector switch (Automatic/ manual) c) LED indicator lamp (RYB pump on/ trip PLC on) d) Push button (Pump on/ off) e) Relays f) Internal wiring and accessories g) Connectors h) Transformers j) MCB of suitable ratings k) SMPS, 24 V DC/ 2 Amps l) Single phase preventer l) MCB DP 20 Amp 10 ka 2 nos

-

-

-

... More
Supply, install, testing & commissioning of PLC (Programmable Logic controller) based control panel for automatic pump control/ protection suitable for Fully Automatic Star Delta Starter With VFD of pump with discharge 2500 LPM & 12 meter head (with all accessories) 02 Nos and conductive level sensor - 06 Nos . The control panel shall perform the following functions:- i) automatic pump on/ off (Level based) ii) Phase failure/ phase reversal and motor overload alarm iii) Automatic toggling of pump motors iv) Manual mode operation of the entire system. v) Sewage water high level and low level indication Panel shall be floor mounted of the size (min) 1500H mm x 1200W mm x 500D mm made of CRCA sheet 3.15 mm thick for outer side and 2 mm thick for inner compartment with pretreated phosphots ( 7 tank processed) duly painted powdered coated RAL 7032 totally enclosed dust proof with openable shutter/ door in the front side, outdoor type double door and consisting of the following:-

2

-

-

... More
a) PLC (Programmable logic controller - ) comprising of input/ output modules b) Selector switch (Automatic/ manual) c) LED indicator lamp (RYB pump on/ trip PLC on) d) Push button (Pump on/ off) e) Relays f) Internal wiring and accessories g) Connectors h) Transformers j) MCB of suitable ratings k) SMPS, 24 V DC/ 2 Amps l) Single phase preventer l) MCB DP 20 Amp 10 ka 2 nos

-

-

-

... More
Supply, Installation, Testing & commissioning Automatic Power Factor Correction improving capacitor bank of capacity 40KVAR in six steps with MPP type power factor corrector system with micro processor based detection and display of selectable /programmable electrical parameters like voltage, input current, capactive current at KVA demand, KW power factor etc ultra fast response for switching ON/OFF of capacitor 40-60 milli seconds necessary control card to control firing of thrysistors. APFC relay to measure, monitor and display various parameters, LED indication for number of capacitor bank steps switched ON/ Power factor lag/lead should be available. The system have following protectors. (a) Overload (b) Under voltage (c) Voltage imbalance (d) Over Temperature. It should have provn the system automatically 'OFF ' after condiction are restored, should be suitable for 440 Volts AC, 50Hz, outdoor type made of 3.15mm CRCA sheet complete with incoming MCCB of suitable range and asthatically design of 3.15mm thick CRCA sheet cabinet outdoor type powder coated complete with forced cross flowing cooling system all as specified. Work also includes making PCC block type 0.6 mtr above ground level and grouting etc.

1

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

42

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

3

-

-

... More
Supply and fixing bracket made out of GI tubing 32 mm dia, light grade 1.5 mtr long including fixing with MS clamps -2 Nos made out of 50 mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia -4 Nos with flat washer (3mm thick) -02 Nos for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete.including 1.sqmm 2.0 core sheathed Copper cable from juction box to connecter of street light fitting complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
Supply and fixing energy efficeint LED street light fitting of 45 Watt pressure die cast Al Housing/body, heat resistant clear toughned glass, better optics for uniform distribution street/ Roadways luminiare with driver, including electric connection complete fitting with all accessoreis and following specifications and all as directed by Engineer-In-Charge. (a) Lumen system efficacy of luminarie should be minimum 110 Lumen per watt. (b) Input voltage range 140 to 270 volts (c) Temp operating range minimum 10°C to Plus 45°C (d) Power factor : minimum 0.95 (e) THD : Max 10% (f) CRI : More than 80 and CCT : 5700 K (g) IP rating : IP66 (h) IK rating : Minimum IK07 (j) Pressure die cast aluminium alloy for housing and heat resistant alear toughened glass (k) Built in potted LED driver of the make as of the luminaire. (l) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection 10 kV (inbuilt + extended) (n) Lens:- High sfficiency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)

24

-

-

... More
Supply and fix 1100 volt grade, PVC round / Flat sheathed, copper conductor (flexible) industrial cable 1.5 sqmm two core for connection to street light fitting and wire drawn through inside of tubular poles complete all as specified and directed by Engineer-in-Charge.

30

-

-

... More
Supply & fix sintex box of size 195 X 135 X 90 mm Cat No GS-JB-2014 Hinged (L) wiith 2 way terminal mounted on epoxy insulators for looping of cable for 1Phase and 1neutral fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40 mm X 4 mm thick with one No MCB SP 6 Amp capacity mounted on din rail inside box. work also includes making suitable hole in pole to take out connections to fitting if required at site and provisioning of PVC insulated copper cable from junction box to conector of street light complete all as specified and as directed by Engineer-in-Charge.

24

-

-

... More
Supply and fix decorative Post-Top latern LED fitting for 360° indirect light of 20 Watt for garden light resistant to impact and corrosion, glare free and better uniformity IP-65 protection/M- Milky version complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fixing Cable 16 sqmm 03 core with copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Supply and fixing Cable 10 sqmm 03 core with copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and as directed by Engineer-in-charge.

150

-

-

... More
Supply and fixing Cable 6 sqmm 03 core with copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and as directed by Engineer-in-charge.

100

-

-

... More
Supply and fixing Cable 4 sqmm 02 core with copper conductor PVC round sheathed (flexible) industrial cable complete all as specified and as directed by Engineer-in-charge.

50

-

-

... More
Sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.

35

-

-

... More
Supply, installation, testing & commissioning of one out-door Diesel Engine driven generating set 415 volts, 100 KVA / 80 KW, 3 phase with neutral, freqency 50Hz, AC generator installed including acoustic enclosure, associated control panel and connected acessories, cooling, ventilation fuel and exhaust system suitable for ambient condition as per CPCB -II Norms approved at Hyderabad and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following:

1

-

-

... More
Alternator: Standard design alternator, Power Rated at 100 KVA / 80 KW, net out put at site after connsidering derating as per site conditions 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8 (lagging) Current 87 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, self excited, self regulated, screen protected drip proof IP 23 enclosure brushless design, insulation class 'H' and Automatic voltage regulation of ± 1% at rated voltage from no load to full load. The permissible overload should be 10% for one hour in 12 hours of duration. The alternator shall be conforming to BS 2613/5000/IS 4722. The alternator shall be in position to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for Hyderabad climate and shall generally confirm to BS-2613/5000/IS-4722.

-

-

-

... More
Diesel Engine: Adequate capacity Diesel Engine capabile of 100 KVA coupled with alternator and after considering derating as per site conditions and power consumed by accessories. The engine shall be directly coupled through closed coupling, turbo charged after cooled, multi cylinder, multi stroke direct injection, cold starting and shall confirm ISO 3046 / BS-5514 with an overload capacity of 10% for one hour in 12 hours continous operation. The engine shall be electric start and shall be suitable for battery assisted Manual / Auto starting. The governing system of the engine shall be electric type and suitable to frequency variation with in ± 1% in case of load is switch on or thrown off. (i) Turbo charger, pulse tuned exhaust manifold. (ii) Cooling System: Mounted radiator with fan and belts & guard, corrosioninhibitor coolent etc. (iii) Silencer: Residential type.

-

-

-

... More
(iv) Exhaust System: Exhaust system complete with flexible stainless steel piping of suitable dia 2.5 mtrs above the adacent bldg as per OEM standard with necessary supports and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure. (v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Fuel injection system with fuel injectors, filters, houses, fuel injection solenoid switch and nozzels. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. (viii) Lub oil pump, filter and coller.

-

-

-

... More
(ix) Intake system: Air intake manifold with dry type air filters. (x) Engine and alternator shall be mounted on common base frame with AVM pads. (xi) Mounted micro processor based control panel having standard features and display engine and electrical parameters. (xii) The engine supplied with first filling of oil of required quantity as recommended by OEM. (xiii) All deliverible shall be confirmed the norms established by CPCB.

-

-

-

... More
AMF Panel: Auto Main Failure (AMF) Panel out door type made out 3.15mm CRCA sheet weather proof powder coated conforming to IS 8623 and IP-54 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 110% load of 100 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable. AMF panel shall house adequate capacity contactors for smooth transfer of load between mains and DG set. Panel shall be operated with three modes of operation. 1. Auto, 2. Manual, 3. Test.

-

-

-

... More
Contactor of Suitable capacity 3 pole with required Nos. as per OEM, TP contactor for netural for both supplies. Suitable capacity of MCCB, 4 Pole for both supplies. CTs 150/5A for both the supplies. Push buttons. Indication Lamps. 2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic / Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications.

-

-

-

... More
Acoustic Enclosure: Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions with the following features: - (i) Custom built product for various equipments, with ensure the optimum performance without duration.

-

-

-

... More
(ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action.

-

-

-

... More
(iv) Special paint treatment with pure polyster powder / epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (vii) The DG set should be provided with the external emergency stop push button and fire alarm. (viii) A see through transparent window infront of engine panel to be provided for monitoring the parameters. (ix) Working space is to be provided around the equipment for easy maintenance / repairs. (x) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (xi) See through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (xii) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided.

-

-

-

... More
(xiii) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xiv) The enclsoure should be provided with bulk head light fitting for inside illumination. (xv) The exhaust pipe along with proper aluminium cladding, shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates. (xvi) The batteries should be placed inside the enclosure inside the DG set on a suitable insulated platform. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xx) The acoustic enclosure parts shall be of powder coated after pre treatment process. (xxi) PCC foundation with anti vibration pads or recommended by manufacturer. (xxii) The contractor shall arrange artificial load for testing DG Set for 12 hours on different load at site and DHPP for testing purpose shall be supplied by the contractor without any extra cost deemed to be inclusive in the rate by contractor for this item.

-

-

-

... More
Supply, installation, testing & commissioning of one out Trolley Mounted Diesel Engine driven generating set 415 volts, 20 KVA / 16 KW, 3 phase with neutral, freqency 50Hz, AC generator installed including acoustic enclosure, associated control panel and connected acessories, cooling, ventilation fuel and exhaust system suitable for ambient condition as per CPCB - II Norms approved at Hyderabad and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following:

1

-

-

... More
Alternator: Standard design alternator, Power Rated at 20 KVA / 16 KW, net out put at site after connsidering derating as per site conditions 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8 (lagging) Suitable Current, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, self excited, self regulated, screen protected drip proof IP 23 enclosure brushless design, insulation class 'H' and Automatic voltage regulation of ± 1% at rated voltage from no load to full load. The permissible overload should be 10% for one hour in 12 hours of duration. The alternator shall be conforming to BS 2613/5000/IS 4722. The alternator shall be in position to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for Hyderabad climate and shall generally confirm to BS-2613/5000/IS-4722.

-

-

-

... More
Diesel Engine: Adequate capacity Diesel Engine capabile of 20 KVA coupled with alternator and after considering derating as per site conditions and power consumed by accessories. The engine shall be directly coupled through closed coupling, turbo charged after cooled, multi cylinder, multi stroke direct injection, cold starting and shall confirm ISO 3046 / BS-5514 with an overload capacity of 10% for one hour in 12 hours continous operation. The engine shall be electric start and shall be suitable for battery assisted Manual / Auto starting. The governing system of the engine shall be electric type and suitable to frequency variation with in ± 1% in case of load is switch on or thrown off. (i) Turbo charger, pulse tuned exhaust manifold. (ii) Cooling System: Mounted radiator with fan and belts & guard, corrosioninhibitor coolent etc. (iii) Silencer: Residential type.

-

-

-

... More
(iv) Exhaust System: Exhaust system complete with flexible stainless steel piping of suitable dia 2.5 mtrs above the adacent bldg as per OEM standard with necessary supports and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure and proper insulation complete for safe exhaust without transforming vibration to the wall of the enclosure. (v) Starting System: Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Fuel injection system with fuel injectors, filters, houses, fuel injection solenoid switch and nozzels. (vii) Fuel tank of adequate capacity: As per OEM norms and specifications designed for above capacity of DG Set. (viii) Lub oil pump, filter and coller.

-

-

-

... More
(ix) Intake system: Air intake manifold with dry type air filters. (x) Engine and alternator shall be mounted on common base frame with AVM pads. (xi) Mounted micro processor based control panel having standard features and display engine and electrical parameters. (xii) The engine supplied with first filling of oil of required quantity as recommended by OEM. (xiii) All deliverible shall be confirmed the norms established by CPCB.

-

-

-

... More
AMF Panel: Auto Main Failure (AMF) Panel out door type made out 3.15mm CRCA sheet weather proof powder coated conforming to IS 8623 and IP-54 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 110% load of 20 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable. AMF panel shall house adequate capacity contactors for smooth transfer of load between mains and DG set. Panel shall be operated with three modes of operation. 1. Auto, 2. Manual, 3. Test.

-

-

-

... More
Contactor of Suitable capacity 3 pole with required Nos. as per OEM, TP contactor for netural for both supplies. Suitable capacity of MCCB, 4 Pole for both supplies. CTs 150/5A for both the supplies. Push buttons. Indication Lamps. 2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic / Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications.

-

-

-

... More
Acoustic Enclosure: Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions with the following features: - (i) Custom built product for various equipments, with ensure the optimum performance without duration.

-

-

-

... More
(ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action.

-

-

-

... More
(iv) Special paint treatment with pure polyster powder / epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (vii) The DG set should be provided with the external emergency stop push button and fire alarm. (viii) A see through transparent window infront of engine panel to be provided for monitoring the parameters. (ix) Working space is to be provided around the equipment for easy maintenance / repairs. (x) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (xi) See through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (xii) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided.

-

-

-

... More
(xiii) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xiv) The enclsoure should be provided with bulk head light fitting for inside illumination. (xv) The exhaust pipe along with proper aluminium cladding, shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates. (xvi) The batteries should be placed inside the enclosure inside the DG set on a suitable insulated platform. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xx) The acoustic enclosure parts shall be of powder coated after pre treatment process. (xxi) The contractor shall arrange artificial load for testing DG Set for 12 hours on different load at site and DHPP for testing purpose shall be supplied by the contractor without any extra cost deemed to be inclusive in the rate by contractor for this item.

-

-

-

... More
M&L for fabrication of trolley to accommodate 20 KVA DG SET, with over all size not less than 2.50 mtrs × 3.50 mtrs using MS channel of size 100 × 50 mm and angle iron 50 × 50 × 6 mm and MS flat wherever required including base of MS sheet 10 gauge fixed properly welded on chassis including fencing all around with MS angle iron 40 × 40 × 6mm and MS flat 40 × 6 mm with XPM mesh, cage not less than 2.5 mtr high cage should be with open able door with locking arrangement at front side duly painted with two coats of synthetic enamel paint over a coat of red oxide steel primer, with towing hook of channel/angle iron, fixed with trolley for easy movement from one place to another place. It shall not be less than 1.25 mtr length from the body of trolley complete all as specified and directed by the EIC with the following:- (a) Supply & fixed tyre tubes of size 7.50 × 16 on suitable size of wheel drum - 04 Nos (Make-MRF / CEAT) (b) Supply & fix leaf spring set of 13 Nos with U clamps - 04 set suitable to take full load of trolley and transformer. (c) Supply & fix axle - 02 Nos between front & rear wheel (d) Supply & fix danger notice plate/board of 11 KV on each side of trolley - 04 Nos (e) The cost of any MS work required for fixing of transformer, LT panel shall deemed to include the rate Note:- (i) Any other work/item not mentioned above but necessary for smooth functioning of the trolley shall be included in the rate quoted by the contractor.

1

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “DISMANTLING AND DEMOLITION WORKS" as listed in Schedule ‘A’ Section - X

1

104028

-

... More
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XI

1

1396827

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.