If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date14 Nov 2024
Closing Date7 Dec 2024
Tender Amount₹ 44,25,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
COMPREHENSIVE MAINT AND DAY TO DAY COMPLAINTS OF VARIOUS TYPE OF MOTOR /PUMP SETS ,SUBMERSIBLE PUMP SETS AND STARTER ACCESSORIES AT DIFFERENT WATER SUPPLY INSTALLATION OF SOUTH SIDE UNDER GE UTILITY BATHINDA .
COMPREHENSIVE MAINT AND DAY TO DAY COMPLAINTS OF VARIOUS TYPE OF MOTOR /PUMP SETS, SUBMERSIBLE PUMP SETS AND STARTER ACCESSORIES AT DIFFERENT WATER SUPPLY INSTALLATION OF SOUTH SIDE UNDER GE UTILITY BATHINDA.
COMPREHENSIVE MAINT AND DAY TO DAY COMPLAINTS OF VARIOUS TYPE OF MOTOR /PUMP SETS, SUBMERSIBLE PUMP SETS AND STARTER ACCESSORIES AT DIFFERENT WATER SUPPLY INSTALLATION OF SOUTH SIDE UNDER GE UTILITY BATHINDA.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, fabricating, installation, testing , commissioning in replacement and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , Indoor type made with 2.0 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 200 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 50 cm each ) made from angle iron of size 50mm x 50mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- ALBERT IKKA PUMP HOUSE (a) MCCB 4 Pole cap-100 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 Nos (b) MCCB 3 Pole cap-40 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 03 Nos (c) Automatic star delta starter, 3 Phase suitable for 10 HP motor -03 Nos (d) Single phase preventor - 3 Nos. (e) Indicator lamp LED type (set of 3) (f) Digital type voltmeter (suitabe capacity) with selector switch -04 Nos (g) Digital type ammeter with CTs and selector switch of suitable capacity -04 Nos (h) Control MCB SP 6 AMP - 05 Nos (h) Compact Motor Protection Relay-MM10-03 NOS (I) On Load Change over switch 125A four Pole -01 NO (j) Phase sequence indicator -03 Nos Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar

1

-

-

... More
Supply, fabricating, installation, testing , commissioning in replacement and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , Indoor type made with 2.0 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 400 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 50 cm each ) made from angle iron of size 50mm x 50mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- Gurnam singh pump house (a) MCCB 4 Pole cap-250 Amps, 415 volts, 36 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 Nos (b) MCCB 3 Pole cap-63 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 07 Nos (c) Automatic star delta starter, 3 Phase suitable for 25 HP motor -04 Nos and 15HP -03 Nos (d) Single phase preventor - 7 Nos. (e) Indicator lamp LED type (set of 3) (f) Digital type voltmeter (suitabe capacity) with selector switch -08 Nos (g) Digital type ammeter with CTs and selector switch of suitable capacity -08 Nos (h) Control MCB SP 6 AMP - 05 Nos (h) Compact Motor Protection Relay-MM10-07 NOS (j) Phase sequence indicator -07 Nos (k) four pole on load change over switch -250A Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar

1

-

-

... More
Supply, fabricating, installation, testing , commissioning in replacment and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , Indoor type made with 2.0 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 1200 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 100 cm each ) made from angle iron of size 75mm x 75mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- OLD SECONDARY PUMP HOUSE INCOMER FEEDER (a) ACB 4 Pole cap-800 Amps, 415 volts, 50 kA (Ics=100% of Icu)MANUAL DRAW OUT TYPE MICROPROCESSOR RELAESE TYPE - 02 Nos BUSCOUPLER (a) ACB 4 Pole cap-800 Amps, 415 volts, 50 kA (Ics=100% of Icu) MANUAL DRAW OUT TYPE MICROPROCESSOR RELAESE TYPE - 01 Nos OUTGOING:- (a) ACB 4 Pole cap-630 Amps, 415 volts, 50 kA (Ics=100% of Icu) MANUAL DRAW OUT TYPE MICROPROCESSOR RELAESE TYPE - 03 Nos (b) MCCB 200 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 02 Nos (c) Automatic star delta starter, 3 Phase suitable for 25 HP motor -03 Nos (d) Single phase preventor - 3 Nos. (e) Indicator lamp LED type (set of 3) (f) Each outgoing and incomer feeder has Digital type voltmeter (suitabe capacity) with selector switch (g) Each outgoiing and incomer feefer has Digital type ammeter with CTs and selector switch of suitable capacity (h) Control MCB SP 6 AMP - 05 Nos (h) Compact Motor Protection Relay-MM10-03 NOS (j) Phase sequence indicator -3 Nos (k) On load changer over switch Each of 1000A four Pole -03 Nos Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar (v) Before commisioning of work contractor shall visit the site and prepare the drawing of new panel as existing LT panel .The panel size should be as Per IS.

1

-

-

... More
Supply, fabricating, installation, testing , commissioning in replacement and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , outdoor type made with 3.15 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 200 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 50 cm each ) made from angle iron of size 50mm x 50mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- FLAUCULATOR PPH (a) MCCB 4 Pole cap-100 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 Nos (b) MCCB 3 Pole cap-40 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 04 Nos (c) DOL STAETER 3 Phase suitable for 3 HP motor -04 Nos (d) Single phase preventor - 4 Nos. (e) Indicator lamp LED type (set of 3) (f) Digital type voltmeter (suitabe capacity) with selector switch -04 Nos (g) Digital type ammeter with CTs and selector switch of suitable capacity -04 Nos (h) Control MCB SP 6 AMP - 05 Nos (j) Phase sequence indicator -03 Nos Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar

6

-

-

... More
Supply, fabricating, installation, testing , commissioning in replacement and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , Indoor type made with 3.15 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 1200 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 100 cm each ) made from angle iron of size 75mm x 75mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- PRIMARY PUMP HOUSE (a) ACB 4 Pole cap-800 Amps, 415 volts, 50 kA (Ics=100% of Icu) MANUAL DRAW OUT TYPE MICROPROCESSOR RELAESE TYPE - 01 Nos (b) MCCB 250 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 03 Nos (C) ACB 4 Pole cap-630 Amps, 415 volts, 50 kA (Ics=100% of Icu) MANUAL DRAW OUT TYPE MICROPROCESSOR RELAESE TYPE - 01 Nos (e) Indicator lamp LED type (set of 3) (f) Each outgoing and incomer feeder has Digital type voltmeter (suitabe capacity) with selector switch (g) Each outgoiing and incomer feefer has Digital type ammeter with CTs and selector switch of suitable capacity (k) On load changer over switch Each of 800A four Pole -01 Nos Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar (v) Before commisioning of work contractor shall visit the site and prepare the drawing of new panel as existing LT panel .The panel size should be as Per IS.

1

-

-

... More
Supply, fabricating, installation, testing , commissioning in replacment and Electrically connecting LT panel Board ,415 volts ,factory made , machine pressed , dust and vermin proof , cubical type , outdoor type made with 3.15 mm thick CRCA sheet , LT Panel internally and externally shall be painted with epoxy powder coating paint for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading , including Bus Bar chamber with aluminium bus bar of 200 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel shall be mounted with angle iron frame and four legs ( length of one leg 50 cm each ) made from angle iron of size 50mm x 50mm x 6mm frame duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade ,Necessary spares such as glands, thimbles , lugs, nuts, bolts etc comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge . Location:- PRIMARY PUMP HOUSE FILTER BED (a) MCCB 4 Pole cap-100 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 01 Nos (b) MCCB 3 Pole cap-40 Amps, 415 volts, 25 kA (Ics=100% of Icu) with adjustable thermal release 0.7 to 1.0 & fixed magnetic type suitable for 10.0 In - 04 Nos (c) Indicator lamp LED type (set of 3) (d) Digital type voltmeter (suitabe capacity) with selector switch -04 Nos (e) Digital type ammeter with CTs and selector switch of suitable capacity -04 Nos Note:- (i) Necessary excavation and earthwork inclusive of quoted rates. (ii) Makiing good distrubed surfaces inclusive of quoted rates. (iii) Necessary spares such as glands, lugs, nuts, bolts etc deemed to be inclusive of quoted rates. (iv) All outgoing feeder shall be connected to suitable size of bus baar

1

-

-

... More
Fixing only of in replacment LT cable of any size as directed by Eng in charge.Note:- The LT cable will be issued to contractor under sch B

950

-

-

... More
fixing only in replacement Compact motor protection relay - MM10 as specified and directed by Engineer-in-charge. Note:- The Relay will be issued to contractor under Sch B. The contractor shall supply and replace the CTs of suitable size and necessary wiring in copper wire of 1 sqmm as directed .

8

-

-

... More
M&L for collection of water sample from different locations as directed by the Engineer-in-Charge in clean/sanitized bottle of capacity 01 Ltr in front of MES rep, carrying out the Bioligical and chemical analysis test from the govt approved laboratory and submiting the test result to Engineer-in-Charge for each sample complete all as directed.

30

-

-

... More
M & L in repair for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground ( earth pit not less than 2.25 m deep below normal ground level), with top edge of the plate vertically to depth of not less than 1.5 m below normal ground level connected to and incl GI strip 4 mm and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl PCC cover and , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and earth work in any type of soil and testing on completion etc complete( Note : PCC chamber shall be constructed at least 1.5m away from earth pit pipe for watering shall be provided in slanting manner.)

11

-

-

... More
THE CONTRACTOR SHALL DEPOSITED THE ALL OLD U/S MATERIALS TO AGE E/M W/S STORE YARD BY HIS OWN ARRANGEMENT WITHOUT ANY FINANCIAL BENEFIT RATES TO BE INCLUDED IN QUOTED RATES.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.