Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date25 Nov 2024
Closing Date24 Dec 2024
Tender Amount₹ 1,17,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning, filling in (Soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as spd and directed

129.1

-

-

... More
Removal of excavated (Soil) to a distance exc 100m but not exc 200m and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified.

98.9

-

-

... More
M&L for treating the Backfill In Contact With Foundation At The Rate Of 7.5 Litres Of Emulsion Per Square Metre Of Vertical Surface (area Of The Sub Structure In Contact With Backfill To Be Measured) complete all as spd and directed.

9.2

-

-

... More
M&L Treating The Top Surface Of Filled Earth At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface complete all as spd and directed

7.36

-

-

... More
M&L Treating The Soil Along With External Perimeter Of Building At The Rate Of 2.25 Litre Of Emulsion Per Metre Of The Perimeter Wall complete all as spd and directed.

26.94

-

-

... More
M&L for Treating The Soil Under Plinth Protection At The Rate Of 5 Litres Of Emulsion Per Square Metre Of Surface Area complete all as spd and directed.

24

-

-

... More
M&L for PCC 1:3:6 type C-2 (using 40mm broken graded stone aggregate) as in foundation, filling and mass concrete complete all as specified.

5.54

-

-

... More
M&L for reinforced cement concrete M-25 (Design Mix) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.

26.34

-

-

... More
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; as Rough finished surfaces of concrete etc complete all as specified and directed.

56.84

-

-

... More
M&L mild steel TMT bars 10mm dia and over cut to length, bent to shape, required including cranking, bending, spirally for hopping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.

15528.33

-

-

... More
M&L for reinforced cement concrete M-25 (Design Mix) in columns, pillars, piers, posts and struts etc complete all as specified and directed.

14.24

-

-

... More
M&L Formwork to sides of pillars, posts, struts, piers, columns and stanchions as Rough finished surfaces of concrete etc complete all as specified and directed.

145

-

-

... More
M&L Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.

2711.61

-

-

... More
M&L for fly ash Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as spd and directed.

12.66

-

-

... More
M&L RCC- M-25(design Mix) Using 20mm Graded Aggregate for wall,retaining wall,basement wall,ballast walls,and the like any thickness above top of footing including attached pilasters and buttresses complete all as spd and directed.

49.54

-

-

... More
M&L for Form Work to faces of wall, retaining wall, abutments, parpet and staircase railings and similar work including attached pilasters ,buttresses as Rough Finished Surfaces Of Concrete Measured Flat For RCC Wall etc complete all as specified and directed.

431

-

-

... More
M&L for reinforced cement concrete M-25 (Design Mix) in beams, cantilevers, shelves, bressummers, lintels over 1.5m span etc complete all as specified and directed.

8.5

-

-

... More
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc as Rough finished surfaces of concrete etc complete all as specified and directed.

79.88

-

-

... More
M&L for reinforced cement concrete M-25 (Design Mix) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.

7.82

-

-

... More
M&L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) as Rough finished surfaces of concrete - Flat complete all as spd and directed.

45.68

-

-

... More
M&L 12 mm thick plaster in 1:6 CM On Fair Faces Of Walls Finished Even And Smooth (without Using Extra Cement) complete all as specified and directed.

332.32

-

-

... More
M&L 5 mm thick in 1:3 CM ceiling Plaster On Fair Faces Of Walls Finished Even And Smooth (without Using Extra Cement) for ground floor complete all as specified and directed.

40.02

-

-

... More
M&L Rendering 15mm thick in two layers (base layer 10mm & finishing layer 5mm thick) in cement mortar (1:4) using liquid water proofing compound in finishing layer on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement, etc complete all as specified & directed. (Note : WPC shall be measured and paid separately)

273.68

-

-

... More
Supply Only integral Water proofing compound

45.02

-

-

... More
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as spd and directed.

2.16

-

-

... More
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified & directed.

27.16

-

-

... More
S&F for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as spd and directed.

2.16

-

-

... More
M&L for Three coats of white wash over walls complete all as specified and directed

332.32

-

-

... More
M&L for Three coats of white wash on ceiling complete all as specified and directed

40.02

-

-

... More
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as spd and directed.

273.68

-

-

... More
M&L for Two Coats Of Synthetic Enamel Paint Over A Coat Of red oxide Primer complete all as spd and directed.

4.32

-

-

... More
M&L for 150 mm thick plain cement concrete 1:3:6 type C-2 (40mm graded aggregate) as in sub base etc complete all as specified & directed.

15.92

-

-

... More
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as spd and directed.

0.8

-

-

... More
M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface

4.7

-

-

... More
M&L for Vitrified ceramic coloured tiles light shade with rectified edges 10mm thick, area of each tile exc 0.18 Sqm but not exc. 0.38 Sqm in floors etc, set & jointed in neat cement slurry and pointed in coloured epoxy grout to match laid over and including 15mm thick screed bed or bedding layer of cement mortar (1:4) over and including 25mm thick cement concrete (1:2:4) type B-0, as leveling course (using 12.5mm graded crushed stone aggregates) surface finished even and rough to receive floor topping etc complete all as specified and directed

14.72

-

-

... More
M&L for 75 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded aggregate) etc complete all as specified and directed

14.72

-

-

... More
M&L for 18 mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing etc complete all as specified and directed

79.8

-

-

... More
M&L for rendering in CM (1:3) 10mm thick as in backing coat of granite complete all as spd and directed.

79.8

-

-

... More
M&L 75mm thick PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in plinth protection laid in panels and joints filled with mix of bitumen and sand (1:3) by weight, finished the surface even and smooth using extra cement etc complete all as specified and directed.

20.2

-

-

... More
M&L for plain cement concrete1:3:6 Type C2 using 40 mm graded aggregates as in surface channel and drains complete all as spd and directed.

1.48

-

-

... More
M&L for extra forming fair finish Drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mi-red/ stopped ends etc complete all as spd and directed.

26.94

-

-

... More
S&F App Based Polymeric Membrane Minimum Weighing 3kg/sqm And Minimum 3mm Thick Reinforced With Polyester Non Wove Fabric (wt. Not Less Than 150 Gms/sqm) Laid On Primed Surface By Torched Application Complete And Finally Finished As Per Manufacturers Instructions complete all as spd and directed.

42.24

-

-

... More
M&L for Rendering 10mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cm (1:3) complete all as spd and directed.

42.24

-

-

... More
Design, supply, install, testing & commissioning two stretcher cum passenger lift of capacity 2000 kg 30 person speed 1 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended,suitable to serve G+01 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, anti-nuisance car call protection, overload device, Nudging,Emergency Fireman'service , Emergency Car Light Unit,,door time protection,Emergency Alarm button,Belt Inspection Drive, Auto Fan cut Off, Extra door time of loddy 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified

2

-

-

... More
The lift shall conform to the following Description of items. [i] Passenger Lift with RCC Wall Shaft [ii] Capacity: 2000 kg. and 30 person [iii] Speed : Up to 0.5mtr/sec.(V3F Speed) [iv] STOPS : 2 Stops With (all opening on the same side) [v] Control: Micro Processor Based V.V.V.F ARD System [vi] Floor designation for Lift:G+1 st Floors [vii] Stops/ Landing for Lift : 2 Stops / 2 Landings (Same Side Operative) [viii] Operation : Down Collective with On/Off Switch [ix] Travel in mm for Lift: 4500 MM (Approx.) [x] Shaft dimension: 2450mm wide X 3250 mm deep (Finished Dim.) [xi] Machine: Directly Placed Above Hoistway [xii] Car Inside dimensions: 1720mm wide X 2000mm deep (Approx.) [xiii] Over Head: 5000 mm [xiv] Depth pit : 1800 mm [xv] Door Operation – Power Operated Automatic [xvi] Landing & Car Door : 6 Panel Solid Center Opening Automatic Door Stainless Steel 304 Grade Hairline Finish – Make Fermator (Spain) – Fire Rated up to 2 hr [xvii] Landing & Car Door Clear Opening Width - 1700 mm, Height – 2500 mm. [xviii] Power requirement: “12.5 kw. @ 415+_10% Volts, 50+_ 3% Frequency, 3 Phases 4 Wires AC Supply for the motor power”. “0.75 Kw@ 230+_ 10% Volts, 50+_ 3% Frequency, Single Phase/2 Wires AC Supply for Lighting and Control System.”

-

-

-

... More
[xix] Landing Hall buttons with direction arrows at all floors. [xx] Surface Mounted Digital Display AVOX Series – Imported from Turkey [xxi] Overload warning indicator in Cabin Hall Button Plate. [xxii] Manually power operated door with Electro-mechanical safety lock. [xxiii] Automatic Rescue device Unit to bring the elevator to landing at nearest floor in case of power failure. [xxiv] Car Operating Hall Plate :- * Elevator Car Alarm signal. * Elevator floor position Digital Display. * Door fully closed signal. * Emergency stop. * Manual Keys for operating ON/OFF Operation. * Battery Operated Emergency Light & Alarm [xxv] Car interior design: Stainless Steel 304 Grade Hairline Finished - Car Sheet Panel thickness - 18 Gauge with Inside Cabin Clear height 2700 mm,Energy Efficient L.E.D. Light in Cabin for uniform illumination in cabin, with state-of-art design False Ceiling, High speed Cross Flow Fan (Blower), S.S.Round Handrail, Anti-Skid P.V.C. Tiles Flooring in Bottom, Surface Mounted Digital Display in Landing & Car Operating Panels [xxvi] Ventilation: Louvers Grill to provide sufficient air circulation in lift car.

-

-

-

... More
SPECIFICATION OF LIFT MAIN COMPONENTS FOR MRL (GEARLESS) PASSENGER LIFT PASSENGER Lift with RCC Wall Shaft [xxvii] MATERIAL DETAILS : Driving Motor – Elevator MRL Gearless Machine “Certified – TUV & ISO 9001-2015” Motor – 12.5 Kw, 16.76 hp Brake – D.C. Electromagnetic Brake  R.P.M = 120 / Duty = S4 / Efficiency = 85%  Insulation Class = F / IP Class = 20 Sheave Specification:  Diameter – 320 mm.  Rope – 8 Nos.  Rope Dia. – 10 mm [xxviii] Car Frame : The car frame shall be constructed of structural steel members of adequate strength. All members are to be securely fastened together to form a unitized section. The crosshead shall be designed to be the pick-up point of ropes. An isolated sub-frame shall be supplied to support the platform. [xxix] Car Safeties :Car safeties shall be supplied. When activated by the governor, the car safeties shall exert a stopping force equally on both side of each guide rail. The operating linkage shall be adjustable and located under the car bottom structure for easy installation, inspection and maintenance from elevator pit. A car safety switch shall be supplied and operated by linkage under the car

-

-

-

... More
[xxx] Car ropes and shackles : Car ropes shall be traction grade with an 8 x 19 construction (Usha Martin make). They shall be of sufficient quantity and size to support the load imposed on them and meets safety factors specified in the Elevator codes. Ropes shall be routed from the rope attachments on the graded pulley mounted on the hydraulic cylinder, down to the car frame and tied with specially design I-bolts on the bottom hitch plate. Cable shackles shall be of wedge type specifically designed for elevators. Compression springs shall be supplied at the end of the ropes where they are attached to top crossbeam. Cellular polyurethane elastomer buffers shall be supplied at the end of the ropes where they are attached to the car crosshead. [xxxi] Counter Frame : Counterweight frame shall be constructed of structural steel members of adequate strength and the top and bottom of the counterweight frame shall be provided with suitable slide guide shoes equipped with replaceable gibs. Counterweight : Counterweight Made in M.S. Cast Iron. Counter Weight Standard size is As per Counter D.B.G. (W) X 125mm (D) X 125mm. Each Counterweight is 50 Kgs. Approximate.

-

-

-

... More
[xxxii] Speed Governor :A mechanically self-resetting pit〚overhead〛 mounted governor shall be supplied. The governor shall not require maintenance or service. The governor shall be equipped with a self-resetting safety switch cutting the elevator safety circuit and a cover to protect from falling debris. The governor tension weight guide stand shall be equipped with a self-resetting slack rope switch. The governor rope shall have a construction of 8 x 19. [xxxiii] Slack rope switches : Self-resetting slack rope switch shall be supplied. It shall be mounted above the compression springs of the ropes attached to the hitch plate on the top crossbeam

-

-

-

... More
[xxxiv] Guide Rails : 16 mm Imported T-Guide Rails – 89 X 62 X 16 of M.S. – Monteffero –Italy for Car Guide Rails.  9 mm Imported T-Guide Rails – 70 X 65 X 9 of M.S. – Monteffero –Italy for Counter Guide Rails [xxxv]Control Panel :  Microprocessor PLC base control panel with down collective system.  Monarch Integrated control Panel make V.V.V.F. Drive with Automatic Leveling Control, 3-phase Power Contractor & O.L.R. Of Telemechanique-Made in France.  Additionally it compress with Low Voltage, High Voltage, and Earth Protection device for Controller.  Single Phase Preventer with a protection against phase sequence reversal.  Control Relay-OEN makes.  Control Panel Box: - 20 Gauge M.S. Powder Coated Sheet Board in Siemens gray colour.  Overload Detect System integrated in Control Panel. [xxxvi] Terminal Limit Switches : Terminal limit switches shall be provided in the elevator hoistway to automatically stop the car at the bottom and top floor. A top over-travel switch, bottom slowdown and top slowdown switches shall also be supplied. [xxxvii] Pit emergency stop switch : An emergency stop switch shall be provided in the pit to cut off the supply to the motor and the control valve “down” direction coils.

-

-

-

... More
[xxxviii] Car top inspection station :An inspection car top station shall be provided on top of the elevator car consisting of “Up” and “Down” constant pressure buttons, incandescent light and emergency stop switch. [xxxix] Positioning device : A positioning device shall be provided to insure accurate position signals relative to the elevator movement. These output signals are used by the controller for the leveling, acceleration and deceleration operations. [xxxx] Automatic Rescue Device :*Automatic Rescue Device for emergency nearest floor landing in power failure. [xxxxi] Alarm bell : An alarm bell shall be provided on top of the elevator car. It shall be connected to the alarm button in the car operating panel [xxxxii] Energy Saving : Energy Saving Operation by Dimming of Displays in Idle Condition Due to LED Light in Car, very low electricity consumption for lighting Auto mode On/ Off feature enabled.

-

-

-

... More
[xxxxiii] Ingenious Design : Control Panel-  Microprocessor PLC base control panel with down collective system.  controls Panel with Automatic Leveling Control, 3-phase Power Contractor & O.L.R. of Telemechanique-Made in France.  Additionally it compress with Low Voltage, High Voltage, and Earth Protection device for Controller.  Single Phase Preventer with a protection against phase sequence reversal.  Control Relay-OEN makes.  Control Panel Box: - 20 Gauge M.S. Powder Coated Sheet Board in Siemens gray colour.  Overload Detect System integrated in Control Panel.

-

-

-

... More
[xxxxiv] Safety Related :  Door Force Detector  Door Nudging Feature  Electronic Doorman  Fire Emergency Return  Fire Operation  High Accuracy Landing Feature(Article 10 of IS:14665:2000, Min. +_12mm)  Inter-Communication System  Elevator Monitoring and Control System  Automatic Rescue Device in Case of Power Failure (ARD)  Multi-Beam Door Sensor (In case of Power Operated Doors)  Overload Holding Stop  CCTV Facility to Integrate with BMS  Jammed Landing Operation Panel Call Button Bypass  Motor Overheat Protection  Phase Failure & Phase Reversal Protection [xxxxv] Operation :  False Call Canceling  Smart Door Open AI  Next Landing in case of Door Malfunction using AI  Out-of-Service by Hall Key Switch  Special Floor Priority Service  Integration with BMS System with either Modbus / Potential Free Contact  Creep-less Operation  Direct Landing at Floor

-

-

-

... More
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fine sand as specified and punned thickness shall be measured and paid.

34

-

-

... More
Supply and laying fly ash brick locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge

3390

-

-

... More
M&L for 1.1 kV grade aluminium conductor, XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded aluminium compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing,lugs with cable ties and termination complete all as specified and directed by engineer-in-charge.

-

-

-

... More
All as per Srl item No. 50 above but of size 3.5 core, 95 mm² (From main panel to proposed FP)

320

-

-

... More
All as per Srl item No. 50 above but of size4 core, 25 mm² (Main Panel to lift machine room)

180

-

-

... More
Supply, installation, testing & commissioning of 20mmx3mm Copper Tape Conductor with fixing accessories and should be tested for electrical resistivity test, Tensile strength, Environmental Test (salt spray & humidity test) to meet the requirements of IS/IEC 62305 and IEC 62561-1&2.etc complete all as specified and directed.

40

-

-

... More
M&L for GI strip of size 32 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.

25

-

-

... More
Supply, installing, testing and commissioning of LT feeder pillar box factory made outdoor type, double door, slopy canopy, fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 65 x 65 x 6mm ,45 cm height, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminium busbar (TPN), suitable double compression copper cable glands complete in all respect for Dg set main Panel and including provn of the following:- Note: The panel shall be as per CPRI certificate. Note :Rates inclusive of PCC complete. (a) Aluminium Bus bar 200-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation b) MCCB 4 pole 415 V 3 phase 63 Amp, 25 KA (Thermal magnetic release) Ics=100%Icu - 01 Nos (Incoming) c) MCCB 3 pole 415 V 3 phase 40 Amp, 16 KA (Thermal magnetic release) Ics=100%Icu - 03 Nos (outgoing) d) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 Nos e) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selector switch - 01 Nos f) RYB LED indicator- one set

1

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised strip of size 32 mm x 6 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc and testing complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for earthing complete with copper earth plate 60cm×60cm×3.15mm thick electrode, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper strip of size 20 mm x 3 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed. Notes: (i) The cost of copper earth continuity conductor with GI pipe 40mm light grade upto 7.5m is deemed to be included in r/o above item. (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item.

4

-

-

... More
OUTSOURCING OF 02 NOS STRETCHER CUM PASSENGAR AUTOMATIC CONTROL LIFT NEAR BLDG NO NP-2 & NP-4 AT MH.

-

-

-

... More
Outsourcing of services for Manning & Operation of 02 Nos stretcher cum passengar automatic control Lift by providing service of 01 lift operator (skilled) (SSC qualified with 2 to 3 year relevant experience) for each lift for smooth and trouble free operation in three shift of 8 hours each in a day on all working days including sunday and Holidays for each lift by employing lift operator (skilled) in each shift and all as specified and directed by Engr-in-Charge. (Note: 02 Nos lift, 1 person in each shift for each lift i.e total 06 Nos lift operator per day to be employed).

11

-

-

... More
Notes : (i) The lift shall be operated daily in three shifts as directed by the Engineer-in-Charge. (ii) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (iii) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (iv) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (v) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc. (vi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (vii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.

-

-

-

... More
(viii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (ix) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. (x) The rate quoted by the bidders shall be deemed to be including basic rate [Minimum wages by Government of India/ State Government/ local body, whichever is higher], employers contribution towards Employees Provident Fund [EPF] liability , contribution towards Employees state insurance corporation [EISC], contribution towards Bonus, Overhead and profit and Labour welfare Cess [LWC] as applicable depending upon the manpower requirement. This will create onus on the bidders to ascertain in the relevant rates and quote accordingly. The rates quoted shall be inclusive of all Taxes, Cess, levies as applicable including GST. (xi) The prevailing Rate/wage/Contribution shall be as applicable on the bid submission end date.

-

-

-

... More
NON COMPREHENSIVE MAINTENANCE FOR 02 NOS STRECHER CUM PASSANGER AUTOMATIC CONTROL LIFT AFTER EXPIRY OF DEFECT LIABILITY PERIOD.

-

-

-

... More
M&L for Non- Comprehensive annual maintenance for 02 Nos STRECHER CUM PASSANGER AUTOMATIC CONTROL LIFT by rep of OEM to serve G+01 upper floors with AC Variable voltage & Variable Frequency Dive (VVVF drive) of capacity 2000 kg, 30 person speed 1 metre/sec with single speed motor., 415 volts, 3 phase AC 50 HZ supply for smooth and trouble free operation including spare parts with periodic routine services, complaints and technician/ attendant for breakdown including replacement of all spare parts and servicing of complete system of the LIFT Located at Bldg No NP-2 and NP-4 in 167 MH complete all as specified in particular specification and as directed by the Engineer-in-Charge as detailed below:-

-

-

-

... More
All as per Srl Item No 59.1 above and comprehensive annual maintenance for 1st year after 02 years completion of defect liability period (1st year of Comprehensive maintenance period FY 2027-28)

1

-

-

... More
All as per Srl Item No 59.1 above and comprehensive annual maintenance for 2nd year after 02 years completion of defect liability period (2nd year of Comprehensive maintennance period FY 2028-29)

1

-

-

... More
All as per Srl Item No 59.1 above and comprehensive annual maintenance for 3rd year after 02 years completion of defect liability period(3rd year of Comprehensive maintennance period FY 2029-30)

1

-

-

... More
Note for SL No: 59 (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in 06 months complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.

-

-

-

... More
(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM. (vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up/ replacement of gear oils, acrylic covers, fuses, copper cables, hardwares like nuts, bolts, emery papers, grease,waste cotton, stationery and other miscellaneous items and all minor & major spare parts. (viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personel. The MoU shall be submitted at least 06 months prior to issue of completion certificate of Phase II as per Work Order No I.

-

-

-

... More
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.