Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Sep 2024
Closing Date15 Oct 2024
Tender Amount₹ 19,40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per above Srl item No. 03 but for one socket out let 5 Amps point controlled by one switch (on same board) complete all as specified and as directed by Engineer-in-charge.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

312

-

-

... More
All as per above Srl item No. 03 but for one socket out let 5 Amps point controlled by one switch (on independent board and not below the any other switch board) complete all as specified and as directed by Engineer-in-charge. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

328

-

-

... More
Material and labour for concealed Point wiring for one light point controlled by two Nos- two way switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).

72

-

-

... More
Material and labour for concealed Point wiring for one socket out let 15/16 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switch, socket complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate).

280

-

-

... More
Supply only modular switch 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.

2741

-

-

... More
Supply only modular switch 16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.

280

-

-

... More
Supply only modular switch 6Amps, single pole, two way (1 module) complete all as specified and as directed by Engineer-in-charge.

144

-

-

... More
Supply only modular Bell Push switch, 6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.

80

-

-

... More
Supply only modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.

640

-

-

... More
Supply only modular Socket outlet multipurpose type 16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.

280

-

-

... More
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge.

80

-

-

... More
Supply and fixing Ceiling Rose, polycarbonate, isolated body, surface bakelite 3 terminal, 240 volts, 5/6 Amp complete all as specified and as directed.

1104

-

-

... More
Supply and fixing Modular type Batten holder polycarbonate cased body (B22 base), with back plate complete all as specified and as directed.

720

-

-

... More
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified. Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

272

-

-

... More
Supply and fixing exhaust fan (heavy duty) steel body, AC single Phase 230V, 50Hz, 900RPM, size 300mm sweep with blades and frame including new mosquito stainless steel wire mesh of guage 0.36mm with suitable wooden frame protection against birds etc mounted in suitable opening arrangement in wall and electric connection with and including three core PVC Insulated PVC Sheathed copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. Note :- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account (ii) Cost for making suitable cutting/opening in wall for fixing of exhaust fan including making good disturbed surface and masonary work shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.

72

-

-

... More
Supply and fixing ventilating Air fresher Fan of size 250mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge. Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.

160

-

-

... More
Supply and fixing (concealed flush to wall) factory made VTPN (Vertical type), 6 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating 150 Amps, with two neutral bar, 2 earth bar and cable tie for cable management, including in built one number MCCB 4 pole 80Amp, 16KA as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ.

2

-

-

... More
Supply and fixing (concealed flush to wall) factory made VTPN (Vertical type), 4 Way 415V, as per IEC 61439-3, DB (made out of CRCA sheet not less than 1.2mm thick, with copper bus bar rating 63 Amps, with two neutral bar, 2 earth bar and cable tie for cable management, including in built one number MCB TPN 16Amp, 10KA as incomer and suitable for mounting MCBs as outgoing, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCBs for outgoing shall be measured and paid separately under appropriate item of BOQ.

8

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, as per IEC 61439-3, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.

64

-

-

... More
Supply and fixing (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated bus bar) SPN, 4 Way 240V, suitable for mounting MCB/Isolator etc, as per IEC 61439-3, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-43 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.

19

-

-

... More
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 06 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge

723

-

-

... More
Supply and fixing MCB ‘B’ curve suitable for 230 volts AC supply, 6 to 32 Amps, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge

75

-

-

... More
Supply and fixing MCB ‘B’ curve suitable for 415 volts AC supply, 16 to 32 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB complete all as specified and as directed by Engineer-in-charge

16

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 4 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volt drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Three runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

1500

-

-

... More
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (05 run i.e 4 runs for main 3 phase & 01 neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volt drawn through and including PVC conduit 32mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed. Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.

200

-

-

... More
Supply and fixing LED lamp minimum 3 star rated 9W LED B-22 base complete all as specified and directed by Engr-in-Charge with following specifications (a) Lumen system efficacy of lamp should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) CRI : More than 70

720

-

-

... More
Supply and fixing LED tube light fitting polycarbonate housing 1 x 18/20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

450

-

-

... More
Supply and fixing LED light fitting 1 x 8/10 Watt, appx 2 feet long with decorative ultra ceiling square profile linear LED lighting fixture with extruded polycarbonate environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) CRCA pre coated housing with plastic end cap. (h) LED Driver of the same make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection minimum 2.5 kV. (l) CCT : Minimum 6000K (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

424

-

-

... More
Supply and fixing LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : 15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

72

-

-

... More
Supply and fixing energy efficient LED security light fitting of 25W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing medium grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

48

-

-

... More
Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.

88

-

-

... More
Material and labour for concealed wiring for TV antenna connection complete with coaxial RG-6 heavy duty PVC insulated sheathed cable with copper conductor having single strand of 0.7 mm dia and a aluminium wire net drawn through PVC conduit complete all as specified and as directed. (TV antenna connection socket outlet, terminal box, conduit with fittings shall be measured and paid separately under appropriate item of BOQ).

60

-

-

... More
Material and labour for concealed wiring for telephone connection complete with PVC insulated sheathed cable with copper conductor having single strand of 0.4 mm dia twin core (one pair) taped for telephone wiring drawn through PVC conduit complete all as specified and as directed. (Telephone connection socket outlet and terminal box, conduit with fittings shall be measured and paid separately under appropriate item of BOQ).

200

-

-

... More
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) 2 pin TV antenna connection socket outlet round flush type duly marked with symbol of TV and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.

72

-

-

... More
Material and labour for Pressed steel powder coated sunken terminal box of size 100mm x100mmx50mm concealed in wall, including inner and outer plates (cover plate) suitable for fixing and including modular type (1 module) telephone connection socket outlet flush type duly marked with symbol of telephone and making good disturbed surfaces of walls by using CM (1:3) complete all as specified and as directed.

8

-

-

... More
Material and labour for concealed in wall rigid non matallic PVC conduit 20mm dia (medium duty, ISI marked) for telephone wiring, cable TV etc inclusive of all fitting & accessories such as tees, bends, elbow, reducer, junction box, pipe hooks etc, bell mouth tube ends including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.

150

-

-

... More
Material and labour for concealed in wall rigid non matallic PVC conduit 25mm dia (medium duty, ISI marked) for telephone wiring, cable TV etc inclusive of all fitting & accessories such as tees, bends, elbow, reducer, junction box, pipe hooks etc, bell mouth tube ends including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed.

150

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)

1

-

1734115.6

... More
Sch 'A' Sec - III (Part-II), INTERNAL WATER SUPPLY WORKS

-

-

-

... More
Supply and fixing brass chromium plated inlet or diverted valve with nozzle compatible for all type of water purifier, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and as directed.

72

-

-

... More
Supply and fixing health faucet fancy type, CP including 1.2 meter long 8mm dia flexible tube and including wall hook and fixing material complete all as specified and as directed by Engineer-in-charge.

88

-

-

... More
Supply and fixing 15 mm bore two way Bib cock/Angle stop valve with flange, cast copper alloy chromium plated, screwed down high pressure with on/off handle screwed end for iron pipe or for unions and fixed complete all as specified and as directed.

88

-

-

... More
Supply and fixing wall mixer valve 3-in-1, 15mm bore, brass chromium plated, for mixing hot & cold water with provision for overhead shower with L bend, screwed down for iron pipe suitable for fixing to wall, complete all as specified and as directed.

24

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “ROAD, PATH AND CULVERT WORKS " as listed in Schedule ‘A’ Section -IV (Part-I)

1

-

11110870.68

... More
Sch 'A' Sec - IV (Part-II), ROAD, PATH AND CULVERT WORKS

-

-

-

... More
Supply and laying/fixing 80 mm thick (M-40 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.

1030

-

-

... More
Supply and laying/fixing 60 mm thick (M-35 grade) precast interlocking tile/paving block factory casted (made by using PVC/ Rubber moulds on Vibrating Table Machine) using grey cement and no pigment, any shape haxagon / trigular / zigzag / I-shaped etc, as directed, confirming to relevant IS, laid over and including 25mm thick layer of sand cushining and filling the interstices etc with sand complete all as specified and as directed.

1000

-

-

... More
Supply and laying factory made kerb stone of size 30x10x45cm of M-25 grade cement concrete laid in position to the required line, level and curvature, jointed with cement mortar (1:3) (1 cement:3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and as directed.

60

-

-

... More
Material and labour for Thermo plastic paint road marking 2mm thick painting (lines, dashes, arrows, letters etc) with road safety spikeries glass beads @ 8% by weight including preparation of new or previously treated road surfaces and applying paint by using special applicator machine with heating arrangement complete all as specified and as directed.

240

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Section -V (Part-I)

1

-

2117734.02

... More
Sch 'A' Sec - V (Part-II), AREA DRAINAGE WORKS

-

-

-

... More
Material and labour for Pre-cast factory made RCC drain of size and shape as directed by GE alongwith male and female ends for proper joining, made of 75mm thick RCC M-30 using 20mm graded aggregate, duly embeded two Nos socket for hoisting including form work etc, hosting and placing at site and jointed in CM (1:4) to form uniform length and fair finish to drain upto 120cm girth (width measured @ Avg of inner and outer girth) complete all as specified and as directed by Engineer-in-Charge. Note : Reinforcement shall be measured and paid separately under respective item of Sch.

74.25

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)

1

-

1225275.76

... More
Sch 'A' Sec - VI (Part-II), SEWAGE DISPOSAL WORKS

-

-

-

... More
Material & Labour for Precast M-30 factory made manhole cover, set in CM (1:4) including necessary form work complete all as specified and as directed (Reinforcement and MS handle shall be measured and paid separately under respective item of Sch).

6.34

-

-

... More
S & F PVC coated factory made MS rungs of size 263mm (L)x165mm (W), overall length 691mm made out of 16mm dia round bar with overall thickness after coating as 25mm fixed in RCC while casting complete all as specified and as directed.

95

-

-

... More
Supply and laying DWCPE (SN8) drain pipes 180mm (OD) and 163mm (ID) dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under appropriate item of BOQ/Sch A.

645

-

-

... More
Supply and laying DWCPE (SN8) drain pipes 200mm (OD) and 175mm (ID) dia as per IS-16098 (Part-II), laid in trenches on and including bed 100mm thick beding comprising of well compacted clean poorly graded gravel, gravel/sand mixture with little or no fines to required slope, including all accessories/fittings/jointing ring, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note : Excavation, earth work and pedestal /anchorage if required shall be measured & paid separately under respective item of Sch.

190

-

-

... More
Supplying, installing, commissioning and testing of Non-clog vertical Submersible pump for handling sewage water and having discharge of minimum 900 LPM and 40M head, 415 Volts, 50 Hz, 'F' class insulation, IP 68 protection, 40 degree centigrade operating temperature with chrome steel impeller and cutter, CI motor body, CI pump housing, stainless steel shaft including hoisting submersible sewage pump into sewage collection tank using suitable stainless steel heavy duty (Gde 316) chain and anchoring with hook on top of sewage tank with necessary nuts, bolts, washers etc including GI pipe ( ISI marked heavy grade) suitable dia appx 8mtr long with tube fittings Viz Tees, Socket bends elbows, union nipple etc screwed and socketed/flange Joints connecting with delivery of open well submersible pump set including clamps complete all as specified and directed.

2

-

-

... More
Supply and fixing Electrical cable PVC insulated unsheathed multistrand copper conductor of size 10 Sqmm single core drawn through and including 63mm dia PVC pipe (heavy duty) from motor to starter for star delta connections complete with coppers lugs complete all as specified.

150

-

-

... More
Supply and fixing Star Delta starter fully automatic in sheet steel enclosure, suitable for Non-clog vertical Submersible pump set, suitable for 3 Phase 415 V 50 Hz AC Supply with Preventor, Suitable for Non-clog vertical Submersible pump Motor complete all as specified and directed.

2

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-9, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

66

-

-

... More
Supply and fixing 150mm dia Non Return Valve (NRV) P.N. 1.0 ISI marked confirming to IS 5312 (Part-I) swing type gun metal flap flanged type including jointing material such as nuts, bolts, washers and rubber sheet etc complete all as specified and as directed.

2

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “SECURITY FENCING AND GATE WORKS" as listed in Schedule ‘A’ Section - VII

1

-

469944.49

... More
Lump sum price worked out by the tenderer for “ EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)

1

-

231578.82

... More
Sch 'A' Sec - VIII (Part-II), EXTERNAL WATER SUPPLY WORKS

-

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 200mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

600

-

-

... More
Supplying, laying, jointing and testing Ductile iron pipe (ISI marked) class K-7, bore 150mm, confirming to IS : 8329-2K, spigot & socketed ends centrifugally cast, with cement mortar lining inside and metallic zinc coating with finishing layer of bituminous paint on outside the pipe, suitable for and including rubber tyton joints (Push-on joint) complete all as specified and as directed. Note : (i) Earth work, DI specials/ fittings shall be measured and paid separetly. (ii) Test Certificate for pipes from manufacturer shall be produced. No payment shall be entertained without Test Certificate.

400

-

-

... More
Supply and fixing cast iron sluice valve 80 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.

5

-

-

... More
Supply and fixing cast iron sluice valve 150 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.

4

-

-

... More
Supply and fixing cast iron sluice valve 200 mm dia with flanged ends class PN 1.0 (heavy duty ISI marked) confirming to IS:14846-2000, drilled type, complete with stainless steel spindle, CI gate with brass ring, iron wheel handle, complete including jointing material such as nuts, bolts, washers and rubber sheet insertion 3.0mm thick at both ends etc complete all as specified and as directed.

1

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 105 X105 X105 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

4

-

-

... More
Material and labour for Construction of brick masonary valve pit chamber size 90 X90 X60 cm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed.

2

-

-

... More
Supply and fixing DI fitting upto 200 mm bore pipe line for reducing/bends (any type radius and angle) tapers any type, straight, bend, increasing decreasing or double socket extra Tee pieces single branch Y 'Junction' double branch cross collers cap etc complete all as specified and as directed. Note:- Make of DI fittings shall be same make as DI pipe or as per recommendation of DI pipe manufacturer.

450

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION, LIGHTNING PROTECTION, DG SET AND LIFT WORKS" as listed in Schedule ‘A’ Section - IX (Part-I)

1

-

3342736.58

... More
Sch 'A' Sec - IX (Part-II), EXTERNAL ELECTRIFICATION, LIGHTNING PROTECTION, DG SET AND LIFT WORKS

-

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

17

-

-

... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing strip 32x6mm by means of GI bolts/nuts/washers and protected by 40 mm bore GI light grade pipe upto test point or upto main switch board / electric equipment / pole / lightning arrestor / HT/LT equipments / GODO switch etc, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing strip upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.

48

-

-

... More
Supply and fixing energy efficient LED street light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 105 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : Minimum IP65. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Morethan 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) Note : (i) GI bracket and clamps shall be measured and paid separetly.

26

-

-

... More
Supply and fixing bracket made out of GI tubing light grade 25mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron of size 25x4 mm with suitable nuts and bolts for holding/fixing of bracket on steel pole including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.

26

-

-

... More
Supply and fixing three core (3x1.5sqmm) flexible flat/round cable, copper conductor multistranded, PVC insulated and overall PVC sheathed, 1100 volt, drawn through LT steel tubular poles or drawn through GI pipe along PCC pole for connection to street light from junction box to light complete all as specified and as directed. Note :- GI Pipes if required same shall be measured and paid seperately under respective item.

260

-

-

... More
Supply and fixing cable junction box of Size 250mm x 200mm x100mm or any other higher size (Suitable for Pole mounting) complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. The polycarbonate junction box shall be environment frinedly, recyclable, UV resistant, halogen and silicon free, anti acid and anti corrosive. The junction box knock out on four side wall and following specifications and all as directed by Engr-in-Charge :- (a) The junction box shall be rated for degree of IP 65 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60695-22, IEC 60670-2 to 5 and grey color according to RAL-9011/ 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self extiguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box shall have 4 pole tinned copper bus bar of size 25mmx3mm complete with one number 20Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (j) Suitable size of mild steel Clamps and screws/nut bolt shall be used for fixing of Junction box..

24

-

-

... More
Sand cushioning, with dry and clean tibba sand (for under ground cable) 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed. Note:- (i) Punned thickness shall be considered for payment purpose (ii) Approved sand free from vegetations, grass and other deleterious substances shall be used.

180

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

1

-

-

... More
Four Pole, Aluminium bus bar 600 Amps - 01 Set

-

-

-

... More
MCCB 400 Amps, Four pole, adjustable thermal magnetic protection, 36 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCCB 160 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 01 No (Outgoing)

-

-

-

... More
MCCB 125 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 04 No (Outgoing)

-

-

-

... More
MCCB 32 Amps, Triple pole and netural (TPN), adjustable thermal magnetic protection, 16/18 KA, 415 V AC supply - 01 No (Outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

4

-

-

... More
Four Pole, Aluminium bus bar 200 Amps - 01 Set

-

-

-

... More
MCCB 100 Amps, Four pole, adjustable thermal magnetic protection, 36 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCB 32 Amps, SPN, 10 KA, C-series, AC supply - 16 No (Outgoing)

-

-

-

... More
MCB 6 Amps, SPN, 10 KA, B-series, AC supply - 02 No (Outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

1

-

-

... More
Four Pole, Aluminium bus bar 250 Amps - 01 Set

-

-

-

... More
MCCB 160 Amps, Four pole, adjustable thermal magnetic protection, 36 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCB 63 Amps, TPN, 10 KA, C-series, AC supply - 02 No (Outgoing)

-

-

-

... More
MCB 40 Amps, TPN, 10 KA, C-series, AC supply - 01 No (Outgoing)

-

-

-

... More
MCB 32 Amps, TPN, 10 KA, C-series, AC supply - 01 No (Outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

1

-

-

... More
Four Pole, Aluminium bus bar 100 Amps - 01 Set

-

-

-

... More
MCCB 63 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCB 20 Amps, TPN, 10 KA, C-series, AC supply - 04 No (Outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

1

-

-

... More
Four Pole, Aluminium bus bar 63 Amps - 01 Set

-

-

-

... More
MCB 40 Amps, Four pole, adjustable thermal magnetic protection, 10 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCB 20 Amps, TPN, 10 KA, C-series, AC supply - 02 No (Outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning and testing of factory made LT panel board (out door for 415 volts, 3 phase, 4 wire AC supply) cubical type suitable size, outer shell made out of 3.15 mm thick CRCA epoxy powder coated sheet and inner shell made out of 2mm thick CRCA epoxy powder coated sheet, factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns, totally enclosed busbar chamber fully comparted type to accommodate the incoming and outgoing each switch gear shall have be independent opening and having provision for front and rear side opening with double door with hinges including locking arrangements (chromium plated 19 mm dia fancy lock) including provision of rubber beading and stainless steel cable glands for each cable to make it weather and vermin proof, provision of air fins for ventilation, The Four Pole bus bar shall be insulated with colour code heat shrinkable sleeve and shall be mounted on suitable size "F" class insulator at an interval not more than 250 mm through out the length of each bus bar, panel shall be mounted on angle iron frame and 04 No legs made from angle of size 40 x40 x5mm, legs shall be 750 mm long, 300 mm grouted in blocks of PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) with 450 mm ground clearance, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, danger notice plate for LT with conventional skull and bones duly riveted/pasted to the panel door, complete including all connections incoming / out going all as directed by Engineer-in-charge and comprising of following accessories :-

1

-

-

... More
Four Pole, Aluminium bus bar 300 Amps - 01 Set

-

-

-

... More
MCCB 160 Amps, Four pole, adjustable thermal magnetic protection, 25 KA, 415 V AC supply - 01 No (incoming)

-

-

-

... More
MCCB 125 Amps, Four pole, adjustable thermal magnetic protection, 16 KA, 415 V AC supply - 02 No (outgoing)

-

-

-

... More
Multifunction meter Digital type showing Voltage, Amp , Frequency, KW , KWH inbuilt selector switch with CT coils for three phase- 01 No

-

-

-

... More
Indicating lamps set RYB - 01 Set of three

-

-

-

... More
Internal power and control wiring with suitable size PVC insulated multistranded copper wire.

-

-

-

... More
Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate. (ii) Drawing of panel shall be approved by GE before fabrication.

-

-

-

... More
Supply, installing, commissioning & testing energy efficient transformer suitable for 315 KVA (Level-2) step down floor mounted outdoor type 11/0.433kv, 3 phase, 50 Hz AC, double wound core type copper wound, oil immersed, air naturally cooled with external cooling tubes, transformer delta connection on HV side and star connected on LV side in accordance with vector symbol Dyn-11 (vector group 4) with neutral brought out on LV side with for earthing and having tapping on HV side for constant output so as to alter/vary secondary voltage (Tapping range + 5 % to - 10% in equal step of 2.5 % ) changed by means of manually operated " off load" taps changing gear. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories. The limit of temperature rise after continuous full load run as specified in IS-1180 (Part-I) 2014 and BEE Certified shall be suitably adjusted to suit the maximum ambient temperature of 55 degree centigrade as prevalent complete all as specified and as directed and shall be comprised with the following fittings and accessories :-

1

-

-

... More
(a) Oil conservator tank with fillings holes and cap filter type drain valve and oil level gauge. (b) Silica gel breather with connecting pipe, first fill of dehydrating agent. (c) Explosion relief mounted on tank with double diaphram and equalizer pipe connected to conservator air tank (pressure release valve) (d) Air release valve plug (e) One cable box on LV side (Secondary) consisting of 04 Nos porcelain bushing with nuts, washers & bushing rods with 01 cable gland suitable for reception of taking out suitable size cable, including gland joints complete all as specified (f) Explosive vent (g) 01 No 100 mm dial type thermometer vapor pressure type having range 0-120 degree centigrade with max temp indicator and resetting device incl max reading pointer washer etc. (h) Thermometer pocket on tank cover (j) 04 Nos plain solid CI detachable rollers (k) Two Nos Earthing terminals marking plate. (l) Rating plate and terminal marking plate (m) Extra bushing for neutral outside the cable box brought out on LV side. (n) First filling of oil conforming to IS and tested upto 60 KV dielectric strength (o) Lifting lugs (p) Oil drain valve with plug (q) One cable box on HV side (Primary) consisting of 01 cable gland suitable for reception of taking in HT cable including gland joints complete all as specified (r) Hand hole of sufficient size to assess interior of tank (s) Dehydrating breather with first filling of Dehydrating agent (t) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strip. (u) Rating plate with terminal marking plate (v) Inspection cover.

-

-

-

... More
Note :- (a) Transformer shall be Pre-Commisioned by SEI/detailed officer by Accepting Officer after installation, before issue of completion. (b) Cost of all necessary T&P and measuring devices shall be provided by the contractor without any extra cost. (c) Drawing of transformer shall be approved by GE before placing the order. (d) PCC foundation, plateform as per manufacturer recommendation (one metre high from ground level) shall be provided by the contractor without any extra cost. (e) Any other item which is required for efficient functioning of transformer is deemed to be included in the quoted rate.

-

-

-

... More
Supply and fixing Lightning arresters pin type complete with all fittings, discharge capacity 65 kilo Amp suitable for 11000 volts complete all as specified and as directed.

2

-

-

... More
Supplying, installing, commissioning and testing complete of manufacturer or OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven Generating Set, radiator cooled, with AMF panel capable of delivering 100KVA (80KW) or nearest higher rating 415 volts AC 3 phase, 4 wire system of supply, 50Hz. The DG set shall consist of diesel engine coupled through flexible coupling to matching alternator and mounted on foundation pads on common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per CPCB-IV norms and as specified) with AMF control panel standardised by manufacturer, inbuilt fuel tank, flexible exhaust pipe, incl necessary PCC foundation as per manufacturer instructions complete all as specified and as directed and comprising with the following:--

1

-

-

... More
Engine (Prime mover) : Diesel Engine 1500 RPM of suitable BHP as recommended by manufacturer (at rated RPM), water cooled, 4 cylinder, inline, 4 stroke, performance class of Generator Set ISO 8528-562 as per latest norms with turbo charged air cooled , 1x88 AH 12 Volts batteries start, mechanical FIP, Electronic Governor, pulse tuned exhaust manifold, stainless steel exhaust flexible connection complete with flywheel and all standard fittings/fixture as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp and pressure gauge, water temp starter, dynamo, fuel tank, fuel and lube oil filter, Dry type replaceable paper element air cleaner etc.

-

-

-

... More
Alternator : AC alternator, self-excited, self-regulated, self-ventilated, brushless design, confirming to BS 2613/5000, 3 phase, 415 volts, 4 wire, output at PF 0.8, 1500 RPM, insulation class ‘H’ enclosure IP 23 complete with AVR with ± 1% voltage regulation, directly coupled to and matched with engine.

-

-

-

... More
Anti-vibration pad for mounting engine alternator assembly on the base frame/plate.

-

-

-

... More
Base frame/plate made out of structural steel as per manufacturer’s recommended design/specifications.

-

-

-

... More
Acoustic Enclosure : Engine Alternator assembly mounted on AV mounts with silencer and SS exhaust bellow suitable optimised to meet stringent noise emission standards as laid down by MOEF/CPCB. Base rail with draw out type fuel tank provided with drain plug, air vent, inlet and out let connection, level indicator, manhole etc.

-

-

-

... More
01 No 12 volt x 88 AH maintenance free batteries complete with suitable size copper lead.

-

-

-

... More
AMF control panel : RAL 9003 white powder coated control panel made out of CRCA sheet provided with AMF system (automatic starting of main failure) and Start Stop push button for manual operating, provide with MCCB of suitable rating with short circuit protection, controller which display voltage, current, KW, PF, Frequency, KWH, lube oil pressure, indicating lamps for ‘load ON’ and ‘set running’ current transformer of suitable rating etc, aluminium bus bar of suitable rating with incoming and outgoing termination complete all as per manufacturer’s recommended design/specifications.

-

-

-

... More
The contractor shall supply following maintemance spare part and tool kit for the generator set :- (i) Fuel filter - 02 Nos (ii) Lube oil filter - 01 No (iii) Air filter - 01 No (iv) V-belt - 02 Sets (v) Tool kit socket set - 01 No (vi) DE Spanner set - 01 No (vii) Ring Spanner set - 01 No (viii) Clamp meter - 01 No

-

-

-

... More
Note :- (i) Any item left out for successful operation of AMF panel is deemed to be included in overall cost quoted. (ii) DG set should be sound proof as per latest policy (iii) Cost of maintenance free batteries as per recommendations of manufacture shall deemed included in unit rate quoted by contractor (iv) Cost of PCC foundation as per recommendations of manufacturer shall deemed included in unit rate quoted by contractor. (v) Initial filling of lubricating oil/coolant and fuel required for testing of DG set shall be provided by the contractor without any extra cost. (vi) Exhaust from DG set shall be as per latest CPCB IV norms. Alternatively emission control device within overall cost quoted shall be provided (vii) Pre commissioning test shall be carried out by rep of Accepting Officer. All necessary equipment’s, consumables and T&P required for successful completion of the test shall be arranged by the contractor and cost for the same shall deemed included in unit rate quoted by contractor. (viii) Contractor shall produce test certificate of DG set, no payment shall be allowed without test certificate.

-

-

-

... More
Supply, installing, commissioning and testing 13 passenger lift, having 1.0 m/s car speed, gearless motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G + 3 upper floors with AC variable voltage & variable frequency drive (VVVF drive), complete with all standard accessories, simplex full collective operation, centre opening doors with door drive, sliding stainless steel doors, automatic rescue device (ARD) system, 2D infrared sensor in full height of door & built in press and speak 3 way intercom. Complete all as specified and as directed and shall conform to the following specifications:

4

-

-

... More
Type of Lift : Passenger Lift

-

-

-

... More
Capacity of Lift : 884 Kg, 13 Person

-

-

-

... More
Rise : up to G+3 Bldg

-

-

-

... More
Stop and opening - 04 stops with all opening on the same side

-

-

-

... More
Controller type : Microprocessor based

-

-

-

... More
Drive : AC VVVF drive

-

-

-

... More
Power Supply : 400/415 Volts (3 Phase AC)

-

-

-

... More
Operation : Full collective operation

-

-

-

... More
Car Group : Simplex Type

-

-

-

... More
Machine : Gearless motor located above shaft in machine room

-

-

-

... More
Traction Media : Steel rope

-

-

-

... More
Car Finish : Rear Mid Panel, Rear Corner Panel, Side Mid Panels, Side Corner Panels, Front Panels all are made of Stainless Steel SS304 with honey comb finish

-

-

-

... More
False Ceiling Finish : Stainless steel with hairline finish and with provision for LED lights specified here-in-after.

-

-

-

... More
Ventilation : PVC heavy duty Cross Flow Fans

-

-

-

... More
Hand Rails : Stainless Steel Finish round Handrails on rear car panels

-

-

-

... More
Flooring : 20mm thick Granite to be provided in the recess car cabin floor and fixing with suitable adhesive over aluminium chequered plate in one piece minimum 3mm thick.

-

-

-

... More
Car door and Landing Door finish : Stainless steel SS-304, mirror finish outside

-

-

-

... More
Fire rated doors : Fire rating - 60 Minutes

-

-

-

... More
PIT DEPTH: 1600

-

-

-

... More
OVERHEAD : 4500

-

-

-

... More
HOISTWAY DIMENSIONS (W x D – mm) : 2500 mm W x 1900 mm D

-

-

-

... More
Car Size (W x D x H - mm) : As per IS-14665 (Part 3 Sec-I) : 2000, height 2200 mm

-

-

-

... More
CAR & HOISTWAY DOOR TYPE : Central opening (CO) doors

-

-

-

... More
DOOR OPENING (W x H - mm) : 900 mm W x 2000 mm H

-

-

-

... More
DOOR OPERATOR : VF

-

-

-

... More
COP : COP (car operating panel) and LOP (landing operating panel) in Stainless Steel Hairline finish with display.

-

-

-

... More
CAR POSITION INDICATOR : Dot Matrix type

-

-

-

... More
HALL FIXTURES : Dot Matrix type

-

-

-

... More
HALL FIXTURE FACE PLATE : Stainless steel hairline finish-SS-304

-

-

-

... More
HALL BUTTON ARRANGEMENT: Hall and call Buttons with illumination and Braille

-

-

-

... More
Car and counter weight guide as per OEM recommendation

-

-

-

... More
Terminal buffers metal spring/oil buffer as per OEM recommendation

-

-

-

... More
STANDARD FEATURES : Anti-nuisance Car Call Protection, Independent Service, Overload Device, Nudging, Emergency Car Light Unit, Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking Door Open/Close Button, Manual Rescue Operation, Auto Fan Cut Off, Over Speed Governor for Car

-

-

-

... More
ALSO INCLUDED : Emergency Firemen’s Service, Automatic Rescue operation, Intercom.

-

-

-

... More
Car Enclosure: Manufactured with stainless steel frame not less than 1.5mm with honey comb finish (SS-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED sleek light fittings (as per manufacturer’s instructions, minimum 04 Nos) operated on commercial supply and one LED light fitting operated on battery with inverter as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection

-

-

-

... More
Floor announcement system in car cabin

-

-

-

... More
Signals: (a) Combined luminous hall buttons with LED hall position indicators at all floors (b) LED car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing (e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door. (h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (j) Infrared door sensor safety edge of door for entire height.

-

-

-

... More
Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open.

-

-

-

... More
Operation: Simplex, full collective automatic operation

-

-

-

... More
Machine Room: Located above the hoist way, details as per building drawings

-

-

-

... More
Hoist way: Construction details as per building drawings

-

-

-

... More
Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc.

-

-

-

... More
One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room

-

-

-

... More
Looking mirror of size 1200x900mm, 5.5mm thick to be provided on rear panel wall (opposite to main door) of car cabin above hand rail

-

-

-

... More
Provision of suitable size of copper conductor XLPE insulated cable from Lift Panel installed at Ground floor to machine room will deemed to be included the rate quoted by the contractor

-

-

-

... More
Supply and fixing Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia and 8mm thick with provision of 500 mm long (minimum) single leg/stand of angle iron 40x40x5 mm, welded/riveted on back side of plate, fixed and grounted in position with with PCC (1:3:6) type C-1, using 20 mm graded stone aggregate block of suitable size complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
Subtotal

-

-

-

... More
Sch 'A' Sec - X , (FIRE FIGHTING WORKS)

-

-

-

... More
Supply and fixing fire hydrant landing valve type 'A' (double head outlet) gunmetal of 65 mm dia with 63 mm dia female outlet complete and 65 mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63 mm with couplings conforming to IS 903 (for internal hydrant at Ground floor to 3rd floor and roof) complete all as specified and as directed.

16

-

-

... More
Supply, installing, commissioning and testing of Fire Hose Cabinet to be mounted externally near the Hydrant Post fabricated from 16 SWG MS Steel of appox size 800 mm x 600 mm x 450 mm with a canopy, door with 4 mm glass encased in heavy grade rubber beading, a key box in built in the box, suitable to accommodate one hydrant valve, one branch nozzle and 30 mtrs hose reel, weather proof, Finished with and including painting of two coats of synthetic enamel paint of post office red colour over a coat of red oxide primer ( Sample to be approved prior to entire supply) complete all as specified and as directed.

16

-

-

... More
Supply, installing, commissioning and testing of wall mounting swinging type First aid fire hose reel with drum, hanging bracket, 30 mtr long and 20mm dia high pressure hose reel as per IS 444 with gunmetal shut off nozzle having 5mm dia orifice. The hose reel shall be conforming to IS 884-1985. Drum shall be fixed on adjoining wall through anchor fasteners/cement concrete book or MS stand as per site requirement complete all as specified and as directed.

16

-

-

... More
Supply, installing, commissioning and testing of 63mm dia Gun metal, short type, instantaneous pattern branch pipe to suit fire hose delivery coupling of 63 mm size complete with GM nozzle of 20 mm nominal size conforming to IS 8090 complete all as specified and as directed.

16

-

-

... More
Supply, installing, commissioning and testing of gun metal body Butterfly valves of size 63mm dia, IS:210, PN-16, confirming to IS:13095 complete all as specified and as directed.

16

-

-

... More
Supply, installing, commissioning and testing of Booster Pump 30 m head, 450 LPM discharge, 440 V, 3 Phase, 50Hz confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings complete all as specified and as directed.

4

-

-

... More
Supply, installing, commissioning and testing 65mm nominal bore, wall thickness 6mm, MS heavy duty ('C' Class) flanged pipe, ISI marked (IS : 1239) with all necessary fittings & fabrication like tees, elbows, flanges, reducers, gaskets, nuts and bolts etc welding or screwed joints as required including fixing of pipe with necessary standard clamps structural steel supports (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red colour over two coats of red oxide primer complete all as specified and as directed.

70

-

-

... More
Supply and fixing trolley mounted water stored pressure type fire extinguishers, 9 Ltr capacity conforming to IS:13386 with extinguishing agent : water+AFFF and propelling Nitrogen gas, wall bracket handle fitted with high pressure flexible discharge hose with discharge throw of 2-5 Mtrs., with ISI certification mark complete all as specified and as directed.

16

-

-

... More
Supply and fixing carbon-di-oxide 3 Kgs capacity fire extinguisher (light weight squeeze grip type) fitted with high pressure wire braided hose and horn shall be flat type and equipped with diffuser inside the horn, and cylinder bearing No., confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed.

32

-

-

... More
Supply and fixing Dry Chemical Powder Fire Extinguisher ( ABC POWDER ) 9 Kgs capacity Stored Pressure type, CE Mark Valve with NRV & Safety Release Provision with EPDM Rubber Hose, The extinguisher is internally coated with Epoxy Polyester and externally coated with Pure Polyester Powder and confirming to IS:15683:2006. Fire rating 3A: 89B, ISI certification mark complete all as specified and as directed.

32

-

-

... More
Supply and fixing mechanical foam Extinguisher of 9 Ltr capacity and confirming to IS:15683:2006 complete all as specified and as directed.

4

-

-

... More
Supply and fixing fire buckets (dry sand) of 7 Kg capacity including hanging arrangements complete all as specified and as directed.

4

-

-

... More
Supply and fixing emergency Exit Sign Board with double side adhesive tape vinyl sticker with forex board (Green and White colour) 30 cm x 10 cm complete all as specified and directed.

64

-

-

... More
Subtotal

-

-

-

... More
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS" as listed in Schedule ‘A’ Section - XI (Part-I)

1

-

1763552.7

... More
Sch 'A' Sec - XI (Part-II) , (EXCAVATION, EARTHWORK AND SITE DEVELOPMENT WORKS)

-

-

-

... More
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and as directed. (For road work)

7300

-

-

... More
Subtotal

-

-

-

... More
Sch 'A' Sec - XII (OUTSOURCING FOR LIFT OPERATION WORK FOR FIRST YEAR)

-

-

-

... More
Providing the services for Manual rescue and operation rescue of 04 No lifts (3 Nos OR block and 01 No JCO block) in Three shifts, one semi skilled lift operator per shift of 08 Hrs for operation of all lifts including providing rescue to the trapped person, maintaining lift panel room, lift car and connected machinery of the lifts, on all seven days of the week (including Sunday and holidays) (including reliever on weekely off), complete all as specified and as directed by Engr-In-Charge. Note :- A mobile phone will be provided to the operator by the contractor, their mobile phone number shall be displayed in each Block and if any call received by the operator for rescue, the operator shall immediately move to the location for rescue operation. The cost for the same shall be deemed to be included in the quoted unit rates and nothing extra shall be payable over and above.

1002

-

-

... More
Subtotal

-

-

-

... More
Sch 'A' Sec - XIII (OUTSOURCING FOR LIFT OPERATION WORK FOR SECOND YEAR)

-

-

-

... More
Providing the services for Manual rescue and operation rescue of 04 No lifts (3 Nos OR block and 01 No JCO block) in Three shifts, one semi skilled lift operator per shift of 08 Hrs for operation of all lifts including providing rescue to the trapped person, maintaining lift panel room, lift car and connected machinery of the lifts, on all seven days of the week (including Sunday and holidays) (including reliever on weekely off), complete all as specified and as directed by Engr-In-Charge. Note :- A mobile phone will be provided to the operator by the contractor, their mobile phone number shall be displayed in each Block and if any call received by the operator for rescue, the operator shall immediately move to the location for rescue operation. The cost for the same shall be deemed to be included in the quoted unit rates and nothing extra shall be payable over and above.

1002

-

-

... More
Subtotal

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.