If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 42,460Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maintenance Of Hv Lv Electrical System
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684144_1Bid Award Id
ViewTender No
CWE/PAT/T-42/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 25 sqmm including necessary crimping with crimping tool complete all as specified and directed .
90
100
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 35 sqmm including necessary crimping with crimping tool complete all as specified and directed .
50
53
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 50 sqmm including necessary crimping with crimping tool complete all as specified and directed .
80
10
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 70 sqmm including necessary crimping with crimping tool complete all as specified and directed .
70
10
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 95 sqmm including necessary crimping with crimping tool complete all as specified and directed .
70
22
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 120 sqmm including necessary crimping with crimping tool complete all as specified and directed .
60
-
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 150 sqmm including necessary crimping with crimping tool complete all as specified and directed .
50
10
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for185 sqmm including necessary crimping with crimping tool complete all as specified and directed .
50
-
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 240 sqmm including necessary crimping with crimping tool complete all as specified and directed
60
-
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable for 300 sqmm including necessary crimping with crimping tool complete all as specified and directed .
40
22
-
... More
Supply and Fix cable lugs aluminium any type suitable for cable up to 400 sqmm including necessary crimping with crimping tool complete all as specified and directed .
35
22
-
... More
Repair/replacement of LT Jumper all as directed and specified
120
-
-
... More
Connecting /disconnecting of air-conditioner in married officers quarters, OTM, offrs Mess from the existing over head lines all as directed and specified (No service of ACs Involved in the item rate) (Cables and materials for connection will be provided by occupant /user of the accn)
150
-
-
... More
Taking out wornout MCCB of any size, any capacity and any rating complete all as specified and as directed.
38
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 63 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz, 16 kA complete all as specified and directed.
8
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 100 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz, 16 kA complete all as specified and directed.
8
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 160 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
6
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 200 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
6
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 250 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
6
-
-
... More
Supply and fix MCCB with adjustable thermal and magentic setting type Release Range 400 Amps 4 Pole breaking capacity at 415 volt AC 50 Hz 36 kA complete all as specified and directed.
4
-
-
... More
Supply, fix and in replacement of LT ACB, 4 Pole, 415V, 50 KA and with thermal magnetic release (manual draw out type) of capacity 630 Amps all as specified and directed
1
-
-
... More
Supply, fix and in replacement of LT ACB, 4 Pole, 415V, 50 KA and with thermal magnetic release (manual draw out type) of capacity 800 Amps all as specified and directed
1
-
-
... More
Supply only the HT fuse wire of size 5 Amps of capacity all as specified and directed.
2
-
-
... More
Supply only the HT fuse wire of size 10 Amps of capacity all as specified and directed
2
-
-
... More
Supply only the HT fuse wire of size 20 Amps of capacity all as specified and directed
3
-
-
... More
Supply only the HT fuse wire of size 32 Amps of capacity all as specified and directed
3
-
-
... More
Supply only the HT fuse wire of size 40 Amps of capacity all as specified and directed
4
-
-
... More
Supply only the HT fuse wire of size 60 Amps of capacity all as specified and directed
3
22
-
... More
Supply only the HT fuse wire of size 100 Amps of capacity all as specified and directed
1
-
-
... More
Replacement of HT Pin/ Disc insulator all as directed and specified (New insulator shall be measured in respective items of BoQ)
45
-
-
... More
Supply only pin type porcelain, vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvansied iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed.
30
-
-
... More
Supply only Disc type porcelain insulator, vitreous 145mm height and 255 dia ball and socket type, white, brown and green " Two in series" assembly for tension with tension clamps for conductor, working pressure 11000 volts grade complete all as specified and directed.
15
-
-
... More
Replacement of HT Jumper all as directed and specified (Materials requried for fault repairs will be measured under relevant items included in BOQ.)
40
-
-
... More
Supply only multi-jointed ACSR jumpers of HT over head lines with and incl XLPE/ PVC insulated 11000 volts multi stranded aluminium conductor single core cable of size 120 sqmm as per colour code in sequence Red ,yellow ,blue and black for neutral incl fixing with ACSR conductors with suitable size PG (Parellel Groove) clamp complete all as specified and directed .(Length of one jumper not exceeding more than 3.0 mtrs).
100
-
-
... More
All as per Srl item No.37.00 here-in-before but of size 240 Sqmm.
30
-
-
... More
Laying only HT/LT cable for providing temporary supply to feeder of various sizes from MES store and deposited back to store yard after permanent rectification of fault. All as directed and specified by Engr in Charge(Cost inclusive of transport of cables from stores to fault sites ,fixing arrangement /dismantling of old cables/refixing of new cables as required at site )
700
-
-
... More
Material and labour for providing necessary following stationary require to lodge the complaint, as per requirement and as per existing sample for a minimum period of 09 Months from the date of commencement of contract for Sub Stn No.1 and MAP Pocket No 5:- (i) Complaint Register/books as per sample. (ii) Complaint Slip/job card as per sample.
(iii) Permit book as per sample.
(iii) Other materials ie glue stick,pen, pencil, carbon paper and stainless steel scale 1'.
1
-
-
... More
Material & Labour for Periodical cutting of trees /trimming of branches along the HT /LT overhead lines in a girth of 03 mtrs on either side of the conductors including removing the same and dumping complete all as directed. Note : Expenditure for necessary tool and plants required for Periodical cutting of trees / trimming of branches along the HT / LT overhead lines are deemed to be included in rate quoted by the contractor. Complete all as specified and as directed.
Note:- (i) Contractor will arrange the security boards/danger boards (Man at work) at the site, so that prevent from any damaged. (ii) Contractor will liable to cutting/trimming the branches within the day after of complaint received.
120
-
-
... More
Supply and fix including commissioning of 16M high mast 360/150--3/3 shaft in two section suitable for 47 m/sec wind speed along with head frame, luminaires carriage suitable for 6-9 luminaires in symmetrical arrangement and other accessories manufactured in factory. Supply of raising lowering system comprising double drum winch, 4mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial.
(a) Supply and fix foundation bolts along with nuts, washers, anchor plate and common template.
(b) Supply and fix LED type single dome aviation obstruction light.
(c) Supply and fix outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals complete all as specified and directed
1
-
-
... More
Material and labour for construction of shallow foundation with concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour and including the erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour and Installation of the mast feeder pillar by grouting the stand in concrete complete all as specified and directed
1
-
-
... More
Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.
22
-
-
... More
Material & Labour for Earthing complete with galvanized earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground to the depth of not less than 2.25 mtr below ground level with top edge of earth plate or a depth not less than 1.50 m below ground level connected to GI strip 32 x 6mm as earth lead by means of galvanized bolts, nuts check nuts and washers and necessary excavation and earth work PCC 1:2:4 type B-1 using 20mm graded brick aggregate for earth pit RCC cover , charcoal & common salt filled in alternate layers funnel with 20mm bore light grade watering pipe, 40mm dia GI pipe light grade for protection of GI strip, wire mesh and connected to earth point including testing on all as specified and shown in electric plate No 3 of SSR part I.
8
-
-
... More
Supply and fix including commissioning and testing of 20 watt Solar integral AIO (All-in-One) street light with high pressure die-cast (LM6 Alloy) Aluminium housing, reliable & robust construction with IP65 & IK08 protection, suitable for OD 50/60mm bracket, having Min 4500 system lumens, suitable for 24hrs (2 Nights) Autonomy. The luminaire should work on Hybrid mode with priority for solar, in case solar charging is not available then it should automatically switch to AC grid supply for reliable operation. Dimming Profile: From Dusk – First 04 hours full brightness level • Next fixed at 30% Brightness level
• Lithium Pherrophosphate Battery capacity min 30Ah@12.8V or 256Wh & Battery Temp range -10 to +50℃. Panel capacity min 60Wp, CRI =70, System Efficacy 150lm/W, & system wattage should not be more than 30W ± 2%, if wattages increases then the size of battery & panel shall also be increased in similar percentage to maintain equal autonomy of the system. The fixture should have designed for street light application & should have flexible angle of mounting from 0-15 Degree for divers geographical condition. Life class of LED System 50000hrs@L70. Note :- Certified, charger efficiency 90% and standards IEC62109-1, IEC61547, CISPR15,
IEC62093, IEC61347-2-13, EN50530, IEC62384 or equivalent BIS Standards. The PV module should be made up of crystalline silicon solar cells "Mono-Crystalline" and must have a certificate of testing conforming to IEC 61215 Edition II / BIS 14286 & IEC 61730-1,2 IEC60598, Operating temp -10 Degree C to 50 Degree C, certifying above given parameters all reports shall be from In-house NABL or IECQ or any international accredited Laboratory..
3
-
-
... More
Supply and fix single arm GRP pole of 5 mtr cylindrical/square with bracket having high impact strength, high bending strength, non conductive, electric insulator, shock proof and non effective from chemical, salt and smog with suitable size of GI nut bolts and taper including PCC work complete all as specified and as directed.