Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date10 Jan 2025
Closing Date4 Feb 2025
Tender Amount₹ 38,82,000 
Notes
Download

Costs

Summary

Special Repair And Replacement Of Oh Conductor With Lt Ug

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and errecting in true vertical position steel tubuler swaged poles 9.0 metre long complete with MS base plate, MS pole cap, bolts nuts & screws as specified type 410 SP-31 including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion with two coats of aluminium paint over a coat of red oxide primer, including necessary excavation & earth work and painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with synthetic enamel paint (white) complete all as specified and directed.

22

100

-

... More
Supply and Fixing PVC insulated and sheated copper conductor of size 1.5 Sqmm 3 core from junction box to street light fittings complete all as specified and directed.

308

53

-

... More
Material and Labourfor earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth strip of size 32X6 mm, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel with and including 40mm GI pipe light grade upto 7.5m long all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3:6 type C-1 with PCC cover and, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.

18

10

-

... More
Material and Labourfor earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.30mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meter deep below normal ground level connected to galvanized earth wire 4 mm dia, 7.5m long means of bolts, nuts, check nuts and washers of galvanized iron or steel with and including 40mm GI pipe light grade upto 7.5m long all as shown in electrical plate No 3 of SSR part I connecting to earthing test point and testing on completion with and including PCC pit in mix 1:3.5:6 type c1 with PCC cover and, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, common salt and charcoal filling, necessary excavation and earth work, complete all as directed.

6

10

-

... More
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.

20

22

-

... More
Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.

55

-

-

... More
Supply,laying, commissioning and testing in trenches or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade of nominal cross sectional area 500 sqmm 3.5 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed

100

10

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 300 sqmm..

300

-

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 240 sqmm..

610

-

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 185 sqmm...

610

22

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 95 sqmm..

220

22

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 70 sqmm..

200

-

-

... More
All as per item No. 10 here-in before but for cable of size 3.5 core 50 sqmm...

300

-

-

... More
All as per item No. 10 here-in before but for cable of size 4.0 core 25 sqmm..

300

-

-

... More
Supply,laying, commissioning and testing in trenches or passing through pipe, XLPE insulated, armoured, electric power UG cable (Heavy duty) with aluminium conductor, 1100 volts grade cable of nominal cross sectional area 16 sqmm 4.0 core including brass compression cable gland, terminal aluminium lugs etc making connection and testing complete all as specified and directed

280

-

-

... More
All as per item No. 18 here-in before but for cable of size 4.0 core 10 sqmm..

945

-

-

... More
Supply and fixing gun metal test point terninal block of size 75 x 75 x 25 mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and directed.

18

-

-

... More
Supply installation, testing and commissioning LT Feeder piller board out door type cubicle panel suitable for 3 phase,4 wire 415 volt 50 hz factory fabricated approved CPRI powder coated made out of 3.15 mm thick CRCA sheet and MS angle iron sectiom 50X50X6mm frame with front and back openable double door system with locking arragement louver and air vent gasket for natural flow of air with canopy, inner compartment made out of 2 mm the CRCA sheet duly compartmentalized for each MCCB of incoming and outgoing with lockable arragement with aluminium bus bar three phase and neutral of capacity of 600 amp marked red, yelllow, black and blue insulators, made of high strength insulated material suitable 1100 voltage all control PVC wires shall be with 2.5 sq mm multistrand copper conductor and shall be properly bunched, tied, frerruled for proper indication , fixed on PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate complete with following accessories:- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 Pole 400Amp 50 KA -1 No (As incoming) (b) MCCB 4 Pole 250 Amp 25 KA - 2 No (As out going) (c) MCCB 4 Pole 63 Amp 10 KA - 1 No (street light) (d) Digital voltmeter (0-500V ) (e) Digital Ammeter suitable rating (f) CTS (g) Selector switches and RYB LED indicator Lamp (set of three)

2

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1 : 2 : 4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland. and with aluminium bus bar three phase and neutral of capacity of 600 Amps from the main incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 400 amps 36 KA - 01 No (incoming) (b) MCCB 4 pole 200 amps 25 KA - 02No (c) MCCB 4 pole 125 amps 25 KA - 01No (d) On load change over switch 4 pole 315 amp 415 Volts use fitted on the panel board (e) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (f) Volt meter (digital type) 0-500 volts with selector switch - 01 No (g) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1: 2: 4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland. and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue insulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 320 amps 50 KA - 01 No (incoming) (b) MCCB 4 pole 250 amps 36 KA - 01No (c) MCCB 4 pole 160amps 25 KA - 01No (d) MCCB 4 pole 125amps 16 KA - 02No (e) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (f) Volt meter (digital type) 0-500 volts with selector switch - 01 No (g) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland. and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue insulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 315 amps 36 KA - 01 No (incoming) (b) MCCB 4 pole 200 amps 25 KA - 02No (c) MCCB 4 pole 125amps 16 KA - 01No (d) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (e) Volt meter (digital type) 0-500 volts with selector switch - 01 No (f) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1: 2:4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland. and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 315 amps 36 KA - 01 No (incoming) (b) MCCB 4 pole 200 amps 25 KA - 01No (c) MCCB 4 pole 160 amps 25 KA - 01No (d) MCCB 4 pole 125amps 16 KA - 02No (e) Change over switch 4 pole 400 amp 415 Volts use fitted on the panel board (f) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (g) Volt meter (digital type) 0-500 volts with selector switch - 01 No (h) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland. and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 200 amps 25 KA - 01 No (incoming) (b) MCCB 4 pole 125amps 16 KA - 02No (c) MCB TPN 63 AMP -01 (d) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (e) Volt meter (digital type) 0-500 volts with selector switch - 01 No (f) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C-1 with 20 mm graded stone aggregate, thimbling and cable entry boxes with cable gland and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable thermal and magnetic levels. (a) MCCB 4 pole 200 amps 36 KA - 01 No (incoming) (b) MCCB 4 pole 125amps 16 KA - 01No (c) MCB TPN 63 AMP -01 (d) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (e) Volt meter (digital type) 0-500 volts with selector switch - 01 No (f) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use with angle iron 50x50x6 mm frame bottom of the panel board, grouted by using PCC foundation 1:2:4 type C-1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland and with aluminium bus bar three phase and neutral of capacity of 1.5 time from the main incoming (Annexe Bldg) marked red, yelllow, black and blue inslulators, made of high strength insulated material :- NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 250 amps 36 KA - 01 No (incoming) (b) MCCB 4 pole 125 amps 25 KA - 02 No OG TO AC CABLE (c) MCB TPN 63 AMP -02 (d) Ampere meter (digital type) 0-500 amps with selector switch - 01 No (e) Volt meter (digital type) 0-500 volts with selector switch - 01 No (f) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Supply, Install , testing and commissioning of Wall Mounted LT panel of suitable size for 3 Phase 415 Volts Indoor type made out 3.15 mm thick CRCA sheet of sides of the panel board, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted on angle iron 50x50x6 mm frame of the panel board, fitted on wall by proper cement work, thimbling and cable entry boxes with cable gland. and the copper bus bar should be 1.5 time from the main incoming covered with protection mesh of 6mm iron wire square mesh having proper opening and closing arrengement with locking arrengement and standard danger sign board plate NOTE:-All MCCB's used are thermal magnetic overload and short-circuit protection class with adjustable tharmal and magnetic levels. (a) MCCB 4 pole 320 amps 50 KA - 01 No (incoming) (b) MCCB 4 POLE 125 amps 25 KA - 04No (outgoing to V TPN DB for light/fan/socket point) (c) On load change over switch 320 ampere capacity inbuilt.-01 (d) Ampere meter (digital type) 0-100 amps with selector switch - 01 No (e) Volt meter (digital type) 0-500 volts with selector switch - 01 No (f) Indicator lamp RYB (3 Nos) - 01 Set

1

-

-

... More
Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and beyond 1.5 mtr deep for laying of cables including taking down complete all as specified and directed.

694.45

-

-

... More
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.

456.87

-

-

... More
Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specified and directed.

237.58

-

-

... More
Material and labour for precast concrete cable covers class class LV, type 1 with peak, size 250mm x 150mm x 40mm laid dry in trenches for cable protection all as specified and directed

14830

-

-

... More
Material & Labour for sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes)

205.34

-

-

... More
Material & Labour for Boring of holes under road, pavement, hard standing by trench-less technology using ultrasound technique and necessary machine suitable to pass through 80mm bore GI tubing and cable etc complete all as specified and directed..

120

-

-

... More
Material and Labourfor providing platform for placing of Transformer size of 3.0 x 2.5 mtr with height of 900mm above GL and 300mm below GL with PCC 1:2:4 type B1 as in foundation and platform including necessary flat angle iron 40x6 mm and XPM for fencing around the transformer for safety complete all as specified and directed..

1

-

-

... More
Supply, Install, testing and commissioning LT feeder pillar BUS BAR BOX of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board IP 54, insulated with PVC sleaves and coloured with (red, yellow, blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire, use fitted on angle iron 25x25x6 mm frame of the panel board, thimbling and cable entry boxes with cable gland and copper bus bar should be 400AMP Capacity complete all as specified and directed.

5

-

-

... More
Supply and fixing cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and grouting lug of suitable size including grouted in PCC foundation of size as directed complete all as specified

31

-

-

... More
Supply and fix PVC Sintex box having aluminium bus bar 4 pole suitable for street light connections including single pole MCB of rating 6 Amps, 2.5 sqmm copper conductor for connection and fixing arrangement to pole all as specified and directed

22

-

-

... More
Dismantling/Taking down old ACSR conductor from LT pole by opening all connections and depositing in safe custody of MES store yard complete all as specified & directed

6

-

-

... More
Material and Labourfor taking out concrete poles/struts, any size and taking safe custody of MES store yard complete all as specified & directed

22

-

-

... More
Material and Labour for cable jointing kit for 1100 Volt grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50- 120 sqmm complete all as specified.

2

-

-

... More
Material and Labour for cable jointing kit for 1100 Volt grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185-240 sqmm complete all as specified.

4

-

-

... More
Material and Labour for cable jointing kit for 1100 Volt grade cable for straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified.

2

-

-

... More
Supply and fix 60 W LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be 90Lm/w.It should have active power factor correction (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment, IP-66 protection class I operating voltage range should be from 120 volt to 270 volt AC and frequency range 50Hz fitting should be suitable for an ambient temparature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire copper conductor 3 x 1.5sqmm with OH line or PVC junction box complete all as specified and directed NOTE:-Size of street light clamp must be suitable for fitting in street light pole neck end complete all as specified and directed..

9

-

-

... More
Material and Labour for taking out insulators of any type and size complete all as specified & directed

100

-

-

... More
Material and Labour for taking out old GI PIPE of any size complete all as specified & directed

75

-

-

... More
Material and Labour for taking out old iron brackets of any size complete all as specified & directed

2

-

-

... More
Material and Labour for taking out XLPE cable of any size complete all as specified & directed

75

1

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.