Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date1 Jun 2024
Closing Date29 Jun 2024
Tender Amount₹ 41,70,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No.1 here- in- before but of capacity 10 KVA to 20 KVA NOTE for item No. 1 to 4 : Items required to be replaced will be measured and paid saparately as supply only and labour for fixing deemed to be included as part of servicing.

5

-

-

... More
Supply only fuel filter primary & secondary (Set of Two) of existing make & specification for 200 KVA DG set all as specified and directed..

1

-

-

... More
Supply only fuel filter primary & secondary (Set of Two) of existing make & specification for 100 KVA to 125 KVA DG set all as specified and directed..

4

-

-

... More
Supply only fuel filter primary & secondary (Set of Two) of existing make & specification for 40 KVA to 62.5 KVA DG set all as specified and directed..

7

-

-

... More
Supply only fuel filter primary & secondary. (Set of Two) of existing make & specification for 10 KVA to 20 KVA DG set all as specified and directed..

5

-

-

... More
Supply only oil filter element of existing make & specification for 200 KVA DG set complete all as specified and directed..

2

-

-

... More
Supply only oil filter element of existing make & specification for 100KVA to 125 KVA DG set complete all as specified and directed..

8

-

-

... More
Supply only oil filter element of existing make & specification for 40 KVA to 62.5 KVA DG set complete all as specified and directed..

7

-

-

... More
Supply only oil filter element of existing make & specification for 10 KVA to 20 KVA DG set complete all as specified and directed..

5

-

-

... More
Supply only Air Cleaner filter element including outer and inner element of existing make & specification for 200 KVA set complete all as specified and directed..

1

-

-

... More
Supply only Air Cleaner filter element including outer and inner element of existing make & specification for 100 KVA to 125KVA set complete all as specified and directed..

4

-

-

... More
Supply only Air Cleaner filter element including outer and inner element of existing make & specification for 40 KVA to 62.5 KVA set complete all as specified and directed..

7

-

-

... More
Supply only Air Cleaner filter element including outer and inner element of existing make & specification for 10 KVA to 20 KVA set complete all as specified and directed..

5

-

-

... More
Supply only 'V' Belt for Dynamo A-49/50 of existing make & specification for 10 KVA to 200 KVA set complete all as specified and directed..

4

-

-

... More
Supply only Air cleaner hose pipe with clamps of existing make & specification for 100 KVA to 200 KVA set complete all as specified and directed..

2

-

-

... More
Supply only Air cleaner hose pipe with clamps of existing make & specification for 10 KVA to 62.5 KVA set complete all as specified and directed..

5

-

-

... More
Supply only Safety Control valve of existing make & specification for 100 KVA to 200 KVA set complete all as specified and directed..

2

-

-

... More
Supply only Safety Control valve of existing make & specification for 10 KVA to 62.5 KVA set complete all as specified and directed..

3

-

-

... More
Supply only flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts of existing make & specification for 200 KVA set complete all as specified and directed..

1

-

-

... More
Supply only flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts of existing make & specification for 100KVA to 125KVA set complete all as specified and directed.

2

-

-

... More
Supply only flexible Pipe for fuel pump to PT pump with banjo, banjo washer and nut, bolts of existing make & specification for 10KVA to 62.5 KVA set complete all as specified and directed..

4

-

-

... More
M&L for servicing of calibration of fuel injection pump of existing make & specification of capacity 200 KVA DG Sets including replacement of plunger, manifold washer etc, all other minor items as required and testing after refixing on engine and setting the rated RPM complete all as specified and directed.

1

-

-

... More
All as per item No. 25 here- in- before but DG set of capacity 100 KVA to 125 KVA

2

-

-

... More
All as per item No.25 here- in- before but but DG set of capacity 40 KVA to 62.5 KVA

4

-

-

... More
All as per item No 25 here- in- before but DG set of capacity 10 KVA to 20 KVA

2

-

-

... More
M&L for servicing/overhauling of injecter nozzle assembly of existing make & specification of capacity 200 KVA DG set including replacement of nozzles, washers, etc and pressure setting as required and replacement of timing shaft with coupling complete all as specified and directed.

1

-

-

... More
All as per item No.29 here- in- before but DG set of capacity 100 KVA to 125 KVA

2

-

-

... More
All as per item No. 29 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

4

-

-

... More
All as per item No. 29 here- in- before but DG set of capacity 10 KVA to 20 KVA

3

-

-

... More
M&L for dismantaling and taking out of self starter from mounting and to carryout complete servicing/overhauling of the same with replacement of carbon brush, armature coil, field coil,solenoid switch, bush and pinion and other related components of DG set of capacity 100 to 200 KVA complete all as specified and directed.

2

-

-

... More
All as per item No.33 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

2

-

-

... More
All as per item No. 33 here- in- before but DG set of capacity 10 KVA to 20 KVA

2

-

-

... More
M&L for repair/servicing and overhauling of unsv dynamo of existing make & specification of DG set capacity 100 to 200 KVA by dismantling the same from DG set after taking down the fan belt & pulley and repairing the same by replacement of armature coil, carbon (1 set) field coil, clutch bearing and other related items and re-assembling all the dismantled items and refixing the same on mountings including testing complete all as specified and directed

2

-

-

... More
All as per item No.36 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

3

-

-

... More
All as per item No.36 here- in- before but DG set of capacity 10 KVA to 20 KVA

2

-

-

... More
S&F in replacement of automatic voltage regulator, Diode forward and reverse, rotating rectifier assembly of existing make & specification of DG set of capacity 100 to 200 KVA complete all as specified and directed.

2

-

-

... More
All as per item No.39 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

3

-

-

... More
All as per item No.39 here- in- before but DG set of capacity 10 KVA to 20 KVA

2

-

-

... More
S&F in replacement of turbo charger repair kit of existing make & specification of DG set of capacity 100 to 200 KVA complete all as specified and directed.

2

-

-

... More
All as per item No.42 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

2

-

-

... More
All as per item No.42 here- in- before but DG set of capacity 10 KVA to 20 KVA

1

-

-

... More
M&L for dismantaling of radiator complete from DG Set of capacity 200 KVA, cleaning/ scraping of depositing manually from outside of the radiator, cleaning all copper tubes of radiator with descalling solution from inside & outside with forced feed method & with water and aircompressor (by using separate chemical pump/ water pump & all compressor ) plugging of all leakage through welding, brazing of copper tubes, cleaning of fins and replacement of gaskets etc complete all as specified and directed.

1

-

-

... More
All as per item No.45 here- in- before but DG set of capacity 100 KVA to 125 KVA

4

-

-

... More
All as per item No.45 here- in- before but DG set of capacity 40 KVA to 62.5 KVA

7

-

-

... More
All as per item No.45 here- in- before but DG set of capacity 10 KVA to 20 KVA

4

-

-

... More
M&L for dismantaling/opening of alternator by disconnecting cable connection and flexible coupling nuts & bolts and alternator foundation nut & bolts including taken back on temporary flat form including strip opening of alternator and checking out worn out part of DG sets of make and capacity 10 KVA to 200 KVA complete all as specified and directed ,

2

-

-

... More
M&L for taking out worn out rotor armature winding/out field coil stator winding and rewinding of rotor armature/field coil stator with supper enamelled copper winding wire of existing gauge of DG sets of capacity 10 KVA to 200 KVA complete all as specified and directed

60

-

-

... More
M&L for insulation of armature with class`B' insulation and varnishing of armature winding and drying up to desired temerature of DG sets of capacity 10 KVA to 200 KVA complete all as specified and directed ,

2

-

-

... More
M&L for insulation of field coil with class`B' insulation and varnishing of armature winding and drying up to desired temerature of DG sets of capacity 10 KVA to 200 KVA complete all as specified and directed by the Engineer-in-Charge,

2

-

-

... More
Re-assembling of rotor and stator after rewinding and re-fixing of alternator with engine by assembling flexible coupling with alternator,mounting with nuts & bolts including making cable connection & testing on complete load of DG set of capacity 10 KVA to 200 KVA complete all as specified and directed.

2

-

-

... More
M&L in replacement of self Sarter 12 volt of DG set of capacity 10 KVA to 63 KVA complete all as specified and directed .

2

-

-

... More
M&L in replacement of self Sarter 12 volt of DG set of capacity 100 KVA to 200 KVA complete all as specified and directed .

2

-

-

... More
M&L in replacement of base relay 12/24 Volt DC of start position of any capacity DG set and mode of cranking relay complete all as specified and directed .

2

-

-

... More
S&F timer card of DG set of capacity 10 KVA to 200 KVA complete all as specified and directed

1

-

-

... More
Supply and top up of Engine Oil SAE 15W/40 Make: HP/Indian oil/Castrol or its equivallent all as specified and directed .

310

-

-

... More
Supply and re-filling of coolent in sealed pack suitable for DG sets of capacity 10KVA to 200 KVA. Make : Valvoline /Castrol super/equivalent as approved by GE..

100

-

-

... More
Supply and re-filling of distiled water in sealed pack suitable for battery of DG of capacity 10KVA to 200 KVA all as directed .

50

-

-

... More
M&L in replacement of PSO 500 controller of AMF of DG set of capacity 100 KVA to 200 KVA of existing make with all accessories as per manufacturer complete all as specified and directed .

1

-

-

... More
S&F in replacement of battery terminal with bolt & nuts complete all as specified and directed .

26

-

-

... More
S&F in repalcement of engine start push button, green suitable for DG sets of any capacity complete all as specified and directed .

3

-

-

... More
S&F in repalcement of engine stop push button, red colour suitable for DG sets of any capacity complete all as specified and directed .

3

-

-

... More
S&F in replacement of fan belt A-44, A-42, A-41,A-40 or as per existing size suitable for DG sets of capacity 10 KVA to 200 KVA complete all as specified and directed .

4

-

-

... More
S&F in replacement of alternator (Dynamo) 12 Volts suitable for DG sets of capacity 10 KVA to 62.5 KVA complete all as specified and directed .

3

-

-

... More
S&F in replacement of alternator (Dynamo) 12 Volts suitable for DG sets of capacity 100 KVA to 200 KVA complete all as specified and directed .

1

-

-

... More
S&F in replacement of stop solenoid assembly for S12 VDC micro pump (single coil) heavy duty electrical control suitable for DG sets of capacity 100 KVA to 200 KVA complete all as specified and directed

2

-

-

... More
S&F in replacement of stop solenoid assembly for S12 VDC micro pump (single coil) heavy duty electrical control suitable for DG sets of capacity 10 KVA to 62.5 KVA complete all as specified and directed

3

-

-

... More
S&F in repalcement of battery cable lead (copper) positive terminal of size 35 Sqmm (198cm long) complete all as specified and directed.

3

-

-

... More
S&F in repalcement of battery cable lead (copper) negative terminal of size 35 Sqmm (198cm long) complete all as specified and directed.

3

-

-

... More
S&F in repalcement of inter connection battery cable lead (copper) with terminal of size 35 sqmm (30cm long) complete all as specified and directed.

2

-

-

... More
S&F in replacement of battery 12 Volts 180AH complete all as specified and directed.

2

-

-

... More
S&F in replacement of battery 12 Volts 100AH complete all as specified and directed.

4

-

-

... More
S&F in replacement of oil temperature gauge suitable for DG Set of capacity 10KVA to 200 KVA complete all as specified and directed.

2

-

-

... More
S&F in replacement of lube oil pressure gauge flexible pipe suitable for DG sets of capacity 10KVA to 200 KVA complete all as specified and directed

2

-

-

... More
M&L in replacement of water temperature gauge suitable for DG set of capacity 10KVA to 200 KVA complete all as specified and directed.

2

-

-

... More
Dismantling of broken door of sound proof canopy of the DG Set of capacity 10 KVA to 200 KVA and taking it to nearest workshop for repair purposes and repairing the door with new hinges ,nut & bolts etc and re-assembling the same at existing position and testing for proper opening and closing of the door including repair of the locking system of the door complete all as specified and directed. Note:- Rate of any cutting/drilling/welding work involves in the job is deemed to be include in the quoted rate of the item.

3

-

-

... More
Rubbing the uneven as well as open surfaces of the DG Sets of capacity 100 to 200 KVA with sand paper,cleaning the grease and oil substances over the area & spray painting with two coats of synthetic enamel painty complete all as specified and directed .

2

-

-

... More
Rubbing the uneven as well as open surfaces of the DG Sets of capacity 10 KVA to 62.5 KVA with sand paper,cleaning the grease and oil substances over the area & spray painting with two coats of synthetic enamel painty complete all as specified and directed .

2

-

-

... More
S&F in replacement of fuel level sensor gauge suitable for DG sets of capacity 10 KVA to 200 KVA complete all as specified and directed. Make : Kirloskar Green Model No 6SL1500TA.

3

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.

6

-

-

... More
M&L for disconnecting electrically & mechanically outdoor DG set of capacity 100 KVA to 200 KVA getting out from foundation plateform by any mechanical means and re-installing at its original position and reconnecting electrically & mechanically complete all as specified and directed . Note:- Re-installing of DG shall be done only after repair of its foundation plateform to be done by the department and contractor's quoted rate shall be deemed to include the same.

1

-

-

... More
M&L for disconnecting electrically & mechanically outdoor DG set of capacity 10 KVA to 62.5 KVA getting out from foundation plateform by any mechanical means and re-installing at its original position and reconnecting electrically & mechanically complete all as specified and directed . Note:- Re-installing of DG shall be done only after repair of its foundation plateform to be done by the department and contractor's quoted rate shall be deemed to include the same.

1

-

-

... More
Repair/replacement of alternaror dynamo wiring complete from DG set to AMF panel board and battery charging unit as per site requirment for DG set of capacity 100 to 200 KVA complete all as specified and directed.

2

-

-

... More
Repair/replacement of alternaror dynamo wiring complete from DG set to AMF panel board and battery charging unit as per site requirment for DG set of capacity 10 KVA to 62.5 KVA complete all as specified and directed.

2

-

-

... More
Attending emergency complaints of DG set of any capacity regarding starting issue arrising from any kind of mechanical & electrical problem and rectify the same complete all as specified and directed.

20

-

-

... More
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor of capacity 10 / 7.5 HP, 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop , dismantling and strip opening of worn out /defective non clog submersible electric motor , taking out brunt stator winding , servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including mechanical seal,insulating material, varnishing and drying and re-assembling , installing, testing and connected at original location and making celectric onnection complete all as specified and directed. Note :Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.

10

-

-

... More
All as per Srl item No. 88 here-in-before but capacity of motor 5/3 HP complete all as specified and directed.

9

-

-

... More
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the centrifugal motor of capacity 40 HP, 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop, dismantling and strip opening of worn out/ defective motor, taking out burnt stator winding, servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including insulating material, varnishing andand drying and re-assembling , repair to concrete foundation with grouting of bolts in concrete & iron frame, installed, testing and connected at original location and making electric connection complete all as specified and directed. Note :Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.

1

-

-

... More
All as per Srl item No. 92 here-in-before but motor of capacity 20 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 92 here-in-before but motor of capacity 12.5/10 HP complete all as specified and directed.

3

-

-

... More
All as per Srl item No. 92 here-in-before but motor of capacity 5/7.5 HP complete all as specified and directed.

5

-

-

... More
All as per Srl item No. 92 here-in-before but motor of capacity 3 HP complete all as specified and directed.

2

-

-

... More
Taking proper shut down in writing, disconnecting all the electrical connections, dismantling the motor of capacity 20 HP (Air blow motor), 3 Phase, 415 volts,from the base plate and pump and transporting the same for repair to workshop, dismantling and strip opening of worn out/ defective motor, taking out burnt stator winding, servicing, cleaning of stator slots, bearing, bushes etc, rewinding of stator coils with superior quality copper enamelled wire of existing size and specification including insulating material, varnishing andand drying and re-assembling , repair to concrete foundation with grouting of bolts in concrete & iron frame, installed, testing and connected at original location and making electric connection complete all as specified and directed. Note : Charges of loading & unloading,transportation,change of unserviceable nut & bolts and necessary concrete work shall be deemed to be included in the quoted rate.

2

-

-

... More
All as per Srl item No. 95 here-in-before but motor of capacity 10/7.5 HP complete all as specified and directed.

3

-

-

... More
M&L for repair and servicing to motor, 3 phase 415 volts, capacity 5/7.5 HP, by dismantling the motor from the pump set, removing the stator/rotor seperately, cleaning, varnishing, heating and drying re-erecting, testing complete all as directed.

5

-

-

... More
All as per Srl item No. 97 here-in-before but of capacity 10/12.5 HP complete all as specified and directed.

3

-

-

... More
All as per Srl item No. 97 here-in-before but of capacity 3 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 97 here-in-before but of capacity 20 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 97 here-in-before but of capacity 40 HP complete all as specified and directed.

1

-

-

... More
M&L for maintenance, servicing, oiling and greasing of air blower assembly, draining out compressor chamber oil, washing out and refilling with new oil of existing specification as recommended by manufacturer including replacement of lubricating oil and minor spare parts, fitting and fastners deemed essential to make system serviceable, smooth and noise free complete all as specified and directed.

9

-

-

... More
Supply only Sodium hypochloride solution in container IS-11673 Grade-II for disinfection of treated water complete all as specified and directed. Note : RV shall be prepared for supply & consumption duly verified by audit authority. Note : Hypochloride solution shall be conforming to IS-11673-1992 and shall be supplied in packed containers. The contractor shall produce test certificates of the hypochloride solution issued by factory/ District Govt Food Inspection lab to ascertain the presence of the chlorine percentage in the consignment. In addition, independent testing for the material shall be got done by the Engineer-in-Charge to verify and check the quality .

12500

-

-

... More
S&F in replacement of DOL starter, push button type, suitable for 5HP, 3 phase 415 V,AC electric motor complete all as specified and directed.

9

-

-

... More
S&F in replacement of DOL starter, push button type, suitable for 7.5HP, 3 phase 415 V,AC electric motor complete all as specified and directed.

8

-

-

... More
S&F in replacement of DOL starter, push button type, suitable for 10HP, 3 phase 415 V,AC electric motor complete all as specified and directed.

6

-

-

... More
S&F in replacement of fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt, suitable for 50 HP motor, Amp range 55-70 complete all as specified and directed.

1

-

-

... More
S&F in replacement of fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt suitable for 20 HP motor, Amp range 28-36 complete all as specified and directed.

4

-

-

... More
S&F in replacement of fully automatic, air break, star delta electric motor starter, 3 phase, 415 volt suitable for 15 HP motor, Amp range 28-36 complete all as specified and directed.

1

-

-

... More
S&F in replacement of MCCB, 3 phase, 4 Pole, 415 volts, of capacity 63 Amps, short circuit breaking capacity 25 KA, fixed thermal and fixed magnetic setting, conforming to IS-13947 Part-III-1993 and IEC-60947 (Part-2) including copper extension terminals thimbles, nut, bolts, washers etc complete all as specified and directed.

3

-

-

... More
M&L for replacement of MCCB, 3 phase, 4 Pole, 415 volts, of capacity 100 Amps, short circuit breaking capacity 35 KA, fixed thermal and fixed magnetic setting, conforming to IS-13947 Part-III-1993 and IEC-60947 (Part-2) including copper extension terminals thimbles, nut, bolts, washers etc complete all as specified and directed.

2

-

-

... More
S&F in replacement of PVC insulated, submersible cable of size 6 Sqmm, 1100 Volt,3 core, flat, copper conductor (including jointing material) complete all as specified and directed.

60

-

-

... More
S&F in replacement of PVC insulated, submersible cable of size 10 Sqmm, 1100 Volt,3 core, flat, copper conductor (including jointing material) complete all as specified and directed.

50

-

-

... More
S&F in replacement of PVC insulated, submersible cable of size 16 Sqmm, 1100 Volt,3 core, flat, copper conductor (including jointing material) complete all as specified and directed.

40

-

-

... More
S&F in repair gland packing in packets of standard length suitable for 40 HP motor pump complete all as specified and directed.

10

-

-

... More
S&F in repair gland packing in packets of standard length suitable for 20/12.5 HP motor pump complete all as specified and directed.

20

-

-

... More
S&F in repair gland packing in packets of standard length suitable for 3 to 10 HP motor pump complete all as specified and directed.

40

-

-

... More
Collection of sample of sewage water from sewage treatment plant and testing it through Govt approved laboratory for testing the pH, COD (mg/l), BOD (mg/l), TSS (Mg/l), Oil and grease (mg/l) & coliform count/100ml complete all as specified and as directed.

16

-

-

... More
S&F in replacement chlorine dosing pump of capacity 0.05 HP,dosing pressure upto 7 Kg/cm² with flow rate 0-6lph including all fixture complete all as specified and directed.

2

-

-

... More
M&L for MBBR media made of poly propylene with virgin plastic UV stabilized milky white specific gravity 0.95 to 0.98 complete all as specified and directed.

25

-

-

... More
Taking proper shut down in writing, disconnecting all the electrical connections,disconnecting the pump from centrifugal/monoblock motor pump sets of capacity up to 3 HP, any make and model & all water connections and removing/taking up from foundation, transporting to civil workshop for repair/strip opening and repairing of pump by changing defective/unserviceable parts such as bearing,shaft,impeller,bush,gland plate etc complete, taking back from workshop,Re-assembling including oiling, greasing & replacement of worn out nuts,bolts gasket etc and installing in its original position at site, making all connections , commissioning and testing etc complete all as specified and directed.

1

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 5 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 7.5 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 10 HP complete all as specified and directed.

3

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 12.5 HP complete all as specified and directed.

1

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 20 HP complete all as specified and directed.

2

-

-

... More
All as per Srl item No. 121 here-in-before but of capacity 40 HP complete all as specified and directed. Note for Ser item No 121 to 127 :-Charges of loading & unloading,transportation,change of unserviceable minor items required for proper functioning of pump shall be deemed to be included in the quoted rate.

1

-

-

... More
S&F in replacement of flexible tyre coupling of size suitable for 10/12.5 HP pump including making alignment of pump and motor complete all as specified and directed.

2

-

-

... More
S&F in replacement of flexible tyre coupling of size suitable for 20 HP pump including making alignment of pump and motor complete all as specified and directed.

2

-

-

... More
S&F in replacement of flexible tyre coupling of size suitable for 5 HP pump including making alignment of pump and motor complete all as specified and directed.

2

-

-

... More
Supply only air compressor oil for air blower complete all as specified and directed.

70

-

-

... More
S&F in replacement of set of Belts of suitable size for 7.5/10 HP Air Blower electric motor complete all as directed.

3

-

-

... More
S&F in replacement of set of Belts of suitable size for 20 HP Air Blower electric motor complete all as directed.

2

-

-

... More
Supply and mixing of Aluminium Sulphate on required basis complete all as specified and directed

750

-

-

... More
M&L for preparation of old steel surfaces of panel of any size and applying two coats of synthetic enamel paint complete all as specified and directed .

25

-

-

... More
S&F in repair power Contactors of size up to 63 Amps 415 Volts with auxilliary contact block, timer delay & mechanical interlocking contactor star-delta starter complete all as specified and directed.

3

-

-

... More
M&L for rewiring of starter panel through specified authorized mechanic complete all as specified and directed.

5

-

-

... More
S&F in repair LED flood light 70 watts,230V,AC,outdoor type with thermal management in multiple optics and equipped with IP66 protection,with impact and corrosion resistant complete with driver and lamp enclosed with glass cover complete all as specified and directed

3

-

-

... More
S&F in replacement twin core cable, 6 sqmm,nominal cross sectional area, multi-stranded, aluminium conductor cable, over all PVC sheathed, 1100 volts grade, heavy duty , PVC insulated complete all as specified and directed

200

-

-

... More
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade complete all as specified and as directed.

110

-

-

... More
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm, 4 core, aluminum conductor, 1100 volts grade complete all as specified and as directed.

50

-

-

... More
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 35 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade complete all as specified and as directed.

50

-

-

... More
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 70 Sqmm, 3.5 core, aluminum conductor, 1100 volts grade complete all as specified and as directed.

40

-

-

... More
S&F in repair rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 Ltr capacity.triple layered, hoisted and fixed in position complete all as specified and directed

1

-

-

... More
Supply only multipurpose grease for lubricating mechanaries complete all as specified and directed

15

-

-

... More
Supply and use bacteria for moving bed bio reactor of STP complete all as specified and directed.

5000

-

-

... More
M&L for prepration of old surfaces of motor, pumps,air blow assembly of different capacity etc including removing existing treatment by scrapping, burning and painting with two coats of synthetic enamel paint complete all as specified and directed

17

-

-

... More
M&L single phase preventer with UV/OV relay power contactor mcx 12(63 Amp) 4 pole with auto/manual selector switch including wiring for protection of motors from over voltage/under voltage complete all as specified and directed. Note :- A Sum of Rs. 1,26,404.00 will be deducted on account of credit for dismantling/ demolished/taking down material. Please refer detail on srl page Nos 35 & 36 (Schedule of credit) of Tender Documents.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.