Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Security and Emergency Services
Eprocure
Opening Date21 Mar 2025
Closing Date12 Apr 2025
Tender Amount₹ 45,00,000
Costs
EMD
₹ 90,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_702246_1Tender No
CWE/TKD/CHD/TOKEN-103 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
S&F in replacement foam pickup tube as per existing make and size complete all as specified and directed.
5
-
-
... More
S&F in replacement of low intensity hooter for warning of fire connected with central control panel installed in each zone inside the rooms complete all as specified and directed Make :Siemens/Safex/ Honeywell
5
-
-
... More
S&F in replacement of intelligent addressable 1 loop control fire alarm control panel 230V AC nominal current 75mA existing complete all as specified and directed. Make Cooper, Model No. CF 1200
5
-
-
... More
S&F in replacement of device loop card for connecting detectors with support upto 254 devices and XLS panel compatiable with addressable detectors, manual call points, modules etc, loop resistance 40 Ohms max loop current 300mA, 24 Volt DC with all connecting accessories suitable for any make complete all as specified and directed.
2
-
-
... More
S&F in replacement of Detectors Complying with and type certified to EN - 54 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS: 11360 with suitable fixing arrangements complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F in replacement of optical type multisensor smoke with heat detector supply voltage 9 to 33 V DC, UUFM/LPC approved with junction box and base to be fixed with suitable fixing arrangement complete all as specified and directed
10
-
-
... More
Supply. installation, testing and commissioning in replacement flame proof triple sensor UV/IR name detector with rugged explosion proof and FM/ATEX/PESO approved enclosure UV range 185-260 nm, IR 3000-5000 nm quiescent current 80 mA separate LED indication for normal and alarm air purging provision protection class IP 66. operating temp 10 Deg C to +55 Deg C, conforming to NFPA 72 E, FM standars class No 3260 and IS code 2189 IP & performance certification by ETDC, Govt of India, LPCB 1259 a/02 approved all as specified and directed by Engr-in-Charge. Make : Advanced (UK), Argus. AGCO, Schrack
5
-
-
... More
Supply and fixing in replacement of fire extinguisher CO2 type 4.5 Kg capacity cylinder ISi marked conforming to IS 15683 class 13 B type of fire fitted with PVC bend horn complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of ABC type fire extinguisher 9 kg capacity ISI marked conforming to IS 15683-with au standard fitting and discharge pipe etc complete all as specified and directed.
20
-
-
... More
Supply & fix in replacement of trolley mounted fire extinguisher, AFFF mechanical foam type (gas pressurized) capacity 50 liter and conforming to IS 4989 complete all as specified and directed.
10
-
-
... More
Material and labour required for cleaning, Servicing, Testing and making complete system functional for existing automatic addressable fire alarm system of Siemens make comprising of approx. 1000 devices, such as detectors manual call points Sounders control module control panels and repeater panels etc Scope is inclusive of all infrastructure require to carry out such as scaffolding ladders or man lift required for working at height 20 Meters in hangar The complete job shall be carried out by authorized vendor Rate are inclusive of all software or hardware parts lf required tor making system functional or up gradation for existing fire detection and alarm panel, Nothing shall be paid extra and including testing complete all as specified and directed.
3
-
-
... More
Supply & fixing in replacement XLPE insulated PVC sheathed armoured copper conductor 4.00 sqmm 2 core on surface of wall/truss with suitable saddles to fix the cable complete as per site requirement complete all as specified and directed .
500
-
-
... More
Supply & fixing in replacement PVC insulated FR LS copper conductor 1.5 sqmm 2 core multi-strand flexible cable drawing in steel conduit complete all as specified and directed.
800
-
-
... More
Supply & fixing in replacement PVC insulated, PVC sheathed cable glvanized steel strip or wire armoured electric control cable with stranded copper conductor of size 1.5 Sqmm 4 Core in existing steel conduit or as per site requirement complete all as specified and directed.
200
-
-
... More
Supply Installation, testing and commisioning of UL Listed and FM approved intelligent addressable relay module for hooters / sounders/ stroves etc. complete all as specified and directed.
10
-
-
... More
Supply Installation, testing and commisioning of UL Listed and FM approved intelligent addressable monitor module sprinklers, flow switch and door hooter complete all as specified and directed.
10
-
-
... More
Supply and fixing LED EXIT Sign 4" x 12" with battery backup, engraving on acrylic Sheet lluminaized frame with LED light red color complete all as specified and directed.
30
-
-
... More
Supply and fixing in replacement of Manual gas release switch of aluminium LM6, lP 65, wall mounting type, red colour complete all as specified and directed.
2
-
-
... More
Material and labour for CO2 gas filling of cylinder (existing cylinder with capacity upto 140 Ltrs ) by disconnecting empty/partially filled cylinder with necessary tools and reconecting as per exising with relevant accessories after filling of the gas in cylinder as per desired level complete all as specified and directed.
3360
-
-
... More
Material and labour for transporting the cylinders mentioned in item No. 23 away from air force station 3 brd for filling the cylinder with CO2 and transporting back from filling station to 3 brd airforce station. Quoted rates to be included for the following.
Note:- (i) Empty/partially filled cylinder to be removed from grnd/first/second/third floor terrace and to be shifted with the help of labour to ground same to be loaded in vehilce for transportation to the filling station. (ii) Filled cylinder to be shifted from vehicle to grnd/first/second/third floor terrace
5
-
-
... More
Supply and fixing of 4 kg capacity HFC 227ea , DLP Assembly with automatic valve CE & pie approved, push in connector for tube, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation complete all as specified and as directed. Make :- Rotarex/Envos/Minimax
12
-
-
... More
Supply and fixing of Linear pneumatic heat detection tube for automatic fire detectin and suppression system made by special modified Polyamide (PA), Color Red RAL300/ Black, High grade quatity,Inner diameter 4mm, Outer Diameter 6 MM, Melting point approx. 222"C, Burst Pressure 100 bar at 20'C. Temperature range : minus 40"C to +80'C. Working Pressure 20Bar at 20"C. Burst Temperature : when Pressurised with dry Nitrogen at 16 bar pressure approx 100"C to 110"C complete all as specified and directed. Make :- Firedetect (Rotarex)/Siemens/Minimax
70
-
-
... More
Supply and fixing of pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars. Switch Type SPST, Normaily Open, Electric Rating : 120/240 V AC-375 VA, 24 VAC-125 VA, Open 160 psi y-7, Close 185 psi y-5,Pressure switch and adaptor 5bar /M10x1 / SPST complete all as specified and directed. Make:- Rotarex/Envos/Minimax
13
-
-
... More
Supply and fixing of End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm, length 2.77/171mm, Gauge scale :0-20 bar. Fitting made by brass (plated /unplated), Staintess steet, Elastomeric Sealings, Copper Nickle plated, Temperature range
TS -20 Deg C till + 6O Deg C, made as per PED Pressure Equipment Directives complete all as specified and directed Make :- Rotarex/Envos/Minimax
13
-
-
... More
Supply and fixing of End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Tube connection 6mm, Length 1.13"/29mm, Fitting made by brass nickel plated material with Elastomeric sealings, Temperature range TS -20 Deg C till+ 60 Deg C, Maximum working pressure 25 Bars, made as per PED pressure equipment Directives complete all as specified and directed. Make :- Rotarex/Envos/Minimax
13
-
-
... More
Supply and fixing of T Connection, Brass, Nickle plated, for 4x6 mm Sensor Tube, quick and easy disassembly using special tool, working pressure 15 bars at 15 Deg Temperature, temperature range-40 Deg C to + 80 Deg C, Elastometric Sealings, External Diameter tube 6mm and as per attached specification. Make :- Rotarex/E nvos/Minimax
13
-
-
... More
Supply, installation, testing in replacement of Fire alarm control panel complying with BS EN 54 2 loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) with all programming feeding as per existing device and battery backup of 04 hours complete all as specified and directed.
1
-
-
... More
Schedule of Credit
-
-
-65165
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%