Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 95,200Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_685909_1Bid Award Id
ViewTender No
GE(S)/PAT/T-66/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender documents containing General conditions special conditions and particular specifications
BOQ Items
... More
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.
404
-
-
... More
Supplying & laying Bricks Sub Class 'B' Designation 75 for laying of LT Cables complete all as specified and directed.
43423
-
-
... More
Returning filling in including, spreading, levelling, watering and well ramming in layers not exc 25cm thick each complete all as specified and directed.
855
-
-
... More
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
492
-
-
... More
M&L for GI tubing light grade of dia 80 mm for passing of cables under the road, floor, along the wall or along the pole complete all as specified and directed .
34
-
-
... More
All as per Item No. 8 above but dia 50 mm complete all as specified and directed.
21
-
-
... More
All as per Item No. 8 above but dia 40 mm complete all as specified and directed.
8
-
-
... More
All as per Item No. 8 above but dia 32 mm complete all as specified and directed.
30.6
-
-
... More
All as per Item No. 8 above but dia 25 mm complete all as specified and directed.
24.6
-
-
... More
All as per Item No. 8 above but dia 20 mm complete all as specified and directed.
20
-
-
... More
Supply, laying, testing and commissioning of cable LT XLPE insulated, PVC sheathed armoured, 1.1 KV grade using stranded conductor aluminium of size 240 Sqmm 3.5 core confirming to IS specification complete all as specified and as directed.
258
-
-
... More
All as per Item No. 14 above but Cable size 185 Sqmm 3.5 core complete all as specified and directed.
120
-
-
... More
All as per Item No. 14 above but Cable size 150 Sqmm 3.5 core complete all as specified and directed.
220
-
-
... More
All as per Item No. 14 above but Cable size 95 Sqmm 3.5 core complete all as specified and directed.
190
-
-
... More
All as per Item No. 14 above but Cable size 70 Sqmm 3.5 core complete all as specified and directed.
382
-
-
... More
All as per Item No. 14 above but Cable size 50 Sqmm 3.5 core complete all as specified and directed.
480
-
-
... More
All as per Item No. 14 above but Cable size 35 Sqmm 3.5 core complete all as specified and directed.
604
-
-
... More
All as per Item No. 14 above but Cable size 25 Sqmm 4 core complete all as specified and directed.
609
-
-
... More
All as per Item No. 14 above but Cable size 16 Sqmm 4 core complete all as specified and directed.
597
-
-
... More
All as per Item No. 14 above but Cable size 16 Sqmm 2 core complete all as specified and directed.
1338
-
-
... More
All as per Item No. 14 above but Cable size 10 Sqmm 2 core complete all as specified and directed.
1008
-
-
... More
All as per Item No. 14 above but Cable size 6 Sqmm 2 core complete all as specified and directed.
392
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.15 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type2, B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories (LT Panel 'A' at S/S No. 5) :-
1
-
-
... More
A:-Incomming: (i) MCCB 350A, 4 pole with rupturing capacity 36 Ka with adjustable thermal & Magnetic release -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB 240 volts - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
B : Al bus bar 600 A for three phase and neutral duly insulated with sleeves of different colour RYB.
-
-
-
... More
Outgoing
-
-
-
... More
C : Outgoing - (i) MCCB 100A, 4 pole with rupturing capacity 16 kA with adjustable thermal & Magnetic release - 02 No,
-
-
-
... More
(ii) MCCB 63A, 4 pole with rupturing capacity 16kA with adjustable thermal & Magnetic release - 04 Nos,
-
-
-
... More
(iii) MCCB 40A, 4 pole with rupturing capacity 16kA with adjustable thermal & Magnetic release - 02 Nos,
-
-
-
... More
(iv) MCB 32A SPN, with rupturing capacity 6 kA - 01 Nos,
-
-
-
... More
(v) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(vi) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note :- Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
Supply & fixing, installation, testing and commissioning of factory fabricated prewired LT feeder pillar box, cubical type of appropriate size out door type dust vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90 cm high (30 cm below ground level and 60 cm above ground level), embedded in PCC (1:2:4 ) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories (Proposed Loc:- LT Panel 'A1' at Bldg No. P-19 of OTM HQ Sqn) :-
1
-
-
... More
(A) Incoming :- (i) MCCB, 63A, 4 Pole with rupturing capaicty 16 KA with adjustable Thermal and Megnetic Release - 1 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB 240 volts - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
(B) Al bus bar 100 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
(C) Outgoing :- (i) MCCB 32A, 4 Pole, 16 KA with adjustable Thermal and Megnetic Release - 03 Nos.
-
-
-
... More
(ii) MCB SPN of rating 16 to 32 A 'B' Curve type - 04 Nos.
-
-
-
... More
Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type 2 B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories (Proposed Loc:- LT Panel 'B' Sub Stn No. 6, NFS) :-
1
-
-
... More
A:-Incomming: (i) MCCB 350A, 4 pole with rupturing capacity 36 Ka with adjustable thermal & Magnetic release -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB 240 volts - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-500 Amps with suitable die cast CTs -01 No.
-
-
-
... More
(B) Aluminium bus bar 600 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
Outgoing
-
-
-
... More
C : Outgoing - (i) MCCB 250A, 4 pole with rupturing capacity 36kA with adjustable thermal & Magnetic release - 02 No,
-
-
-
... More
(ii) MCCB 200A, 4 pole with rupturing capacity 36kA with adjustable thermal & Magnetic release - 01 Nos,
-
-
-
... More
(ii) MCCB 100A, 4 pole with rupturing capacity 16kA with adjustable thermal & Magnetic release - 01 Nos,
-
-
-
... More
(ii) MCCB 40A, 4 pole with rupturing capacity 10kA with adjustable thermal & Magnetic release - 02 Nos,
-
-
-
... More
(iv) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(v) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note :- Incoming and outgoing cable shall be fixed with appropriate size of thimbles.
-
-
-
... More
Supply & fixing, installation, testing and commissioning of factory fabricated prewired LT feeder pillar box, cubical type of appropriate size out door type dust vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90 cm high (30 cm below ground level and 60 cm above ground level),Panel embedded in PCC (1:2:4 ) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories (Proposed Loc:- LT Panel 'B1' neat T-44 Cafeteria) :-
1
-
-
... More
(A) Incoming :- (i) MCCB, 200A, 4 Pole with rupturing capaicty 25 KA with adjustable Thermal and Megnetic Release - 1 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB 240 volts - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
(B) Al bus bar 400 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
(c) Outgoing :- (i) MCCB 63A, 4 Pole, 16 KA with adjustable Thermal and Megnetic Release - 02 Nos.
-
-
-
... More
(ii) MCCB 40A, 4 Pole, 16 KA with adjustable Thermal and Megnetic Release - 03 Nos.
-
-
-
... More
(iii) MCCB 32A, 4 Pole, 16 KA with adjustable Thermal and Megnetic Release - 01 Nos.
-
-
-
... More
(v) MCB SPN of rating 20 to 32 Amps 'B' Curve type - 03 Nos.
-
-
-
... More
Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Supply & fixing, installation, testing and commissioning of factory fabricated prewired LT feeder pillar box, cubical type of appropriate size out door type dust vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having Proposed Locactionking arangement mounted on four legs 90 cm high (30 cm below ground level and 60 cm above ground level), embedded in PCC (1:2:4 ) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories (Proposed Loc:- LT Panel 'B2' near Shiv Temple at HQ Bde) :-
1
-
-
... More
(a) Incoming :- (i) MCCB, 40 A, 4 Pole with rupturing capaicty 16 KA with adjustable Thermal and Megnetic Release - 1 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB 240 volts - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Digital Ammeter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
(b) Al bus bar 100A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
(c) Outgoing :- (i) MCB SPN of rating 6 to 32 Amps 'B' Curve type - 05 Nos.
-
-
-
... More
Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type 2 B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories. (Proposed Loc:- LT Panel 'B3' near Bldg No. T-109/Qtr Gd)
1
-
-
... More
A):-Incomming: (i) MCCB 250A, 4 pole with rupturing capacity 36 KA with adjustable thermal & Magnetic release -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Digital Ammeter, frequency meter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
B):- Al Busbar 400 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
C) :- Outgoing - (i) MCCB 63A, 4 pole with rupturing capacity 16 kA with microprocessor type - 03 No,
-
-
-
... More
(ii) MCCB 40A, 4 pole with rupturing capacity 16 kA with microprosser type- 02 No,
-
-
-
... More
(ii) MCCB 32A, 4 pole with rupturing capacity 16 kA with microprosser type- 01 No,
-
-
-
... More
(iii) MCB 25A, SPN with rupturing capacity 6 kA - 05 Nos,
-
-
-
... More
(iii) MCB 20A, SPN with rupturing capacity 6 kA - 05 Nos,
-
-
-
... More
(iv) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(v) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note :- Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type 2 B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories. (Proposed Loc:- LT Panel near Bldg No. P-32 JCO Md Accn, Pratham Vatika)
1
-
-
... More
A):-Incomming: (i) MCCB 160A, 4 pole with rupturing capacity 25 KA with adjustable thermal & Magnetic release type -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Digital Ammeter, frequency meter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
B):- Al Busbar 300 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
C) :- Outgoing - (i) MCCB 63A, 4 pole with rupturing capacity 16 kA with microprocessor type - 01 No,
-
-
-
... More
(ii) MCCB 32A, 4 pole with rupturing capacity 16 kA with microprosser type- 08 No,
-
-
-
... More
(iii) MCB 20A, SPN with rupturing capacity 6 kA - 03 Nos,
-
-
-
... More
(iv) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(v) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note :- Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type 2 B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories. (Proposed Loc:-LT Panel rear of Bldg No. P-17/1, MES Complex)
1
-
-
... More
A:-Incomming: (i) MCCB 100A, 4 pole with rupturing capacity 25 KA with adjustable thermal & Magnetic release type -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-400 Amps with suitable die cast CTs -01 No.
-
-
-
... More
B : Al Busbar 250 A for three phase and neutral duly insulated with sleeves of different colour RYB .
-
-
-
... More
Outgoing
-
-
-
... More
C : Outgoing - (i) MCCB 32A, 4 pole with rupturing capacity 16 kA with adjustable thermal & Magnetic release type - 03 No,
-
-
-
... More
(ii) MCB 32A, SPN with rupturing capacity 10 kA - 03 Nos,
-
-
-
... More
(iii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iv) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
M& L for LT feeder pillar box, installation, testing and commissioning, factory fabricated prewired, CPRI aproved, cubical type of appropriate size out door type, dust and vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.0 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) , type 2 B2 Block each of size 200x200x300 complete all as specified & directed by the Engr-in-Charge incl cost and to accommodate the following accessories. (Proposed Loc:- LT Panel near Bldg P-25/1)
1
-
-
... More
A:-Incomming: (i) MCCB 125A, 4 pole with rupturing capacity 25 KA with adjustable thermal & Magnetic release type -01 No.
-
-
-
... More
(ii) Indicators lamp LED type RYB - 01 Set.
-
-
-
... More
(iii) Digital Voltmeter with built in selector switch 0-500 Volts -01 No.
-
-
-
... More
(iv) Frequency, Digital Ammeter with built in selector switch 0-200 Amps with suitable die cast CTs -01 Set.
-
-
-
... More
B : Al Busbar 250 A for three phase and neutral duly insulated with sleeves of different colour RYB
-
-
-
... More
Outgoing
-
-
-
... More
C : Outgoing - (i) MCCB 40A, 4 pole with rupturing capacity 16 kA withadjustable thermal & Magnetic release-02 NoS.,
-
-
-
... More
(Ii) MCCB 32, 4 pole with rupturing capacity 25 kA with microprocessor type - 06 Nos,
-
-
-
... More
(iii) MCB 32A, SPN with rupturing capacity 10 kA - 01 Nos,
-
-
-
... More
(iv) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(v) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
Note : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimbles.
-
-
-
... More
(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.
-
-
-
... More
(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.
-
-
-
... More
S&F Street light automatic power control LT panel outdoor type made out of CRCA sheet 3.0 mm thick with Voltmeter, Ameter, frequency meter & timer switch, RYB indicator and internal wiring etc. with Single phase Aluminium busbar rating 60A. Incoming:- MCB, SPN, 20A, -01 No. Outgoing:- MCB SPN 6/10 A-03 Nos. Panel will be grouted in PCC work on angle iron of siutable size all as specified and directed.
2
-
-
... More
Cable route indicator shown "LT UG cables" painted in blue colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 20 x 20 x 60cm in ground, complete all as specified and directed.
296
-
-
... More
M & L for submain wiring with 2x1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor cable 1100 volts grade drawn through suitable size PVC flexible conduit from Jn box to St Light connection complete all as specified and as directed by Engr-in-charge Note :- 2 runs of 1.5 sqmm and one run of 1.0 Sqmm PVC copper cable with PVC flexible conduit will be measured as one length.
274
-
-
... More
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 3.25 mtr deep below the normal ground level ) with top edge of plate not less than 2.5 mtr below the normal ground level connected to galvanized earth strip 32X6 mm thick by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) medium grade GI watering pipe 20mm dia with funnel and wire mesh and 40 mm bore GI pipe light grade proection pipe up to test point etc including excavation and charcoalt ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
20
-
-
... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6 mm size galvanised iron Strip complete all as specified and directed.
24
-
-
... More
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I .
1
-
-
... More
M&L for Cutting of road /PCC path upto the thickness of road/PCC for laying of protection pipe for LT Cable complete all as specified and directed.
107
-
-
... More
M&L for trench less drilling of Road/PCC Surface by Machine without damaging near by area, depth as per site requirement for crossing of LT Cables protection pipe of dia upto 80 for LT Cable 185/240 Sqmm, 3.5 Core complete all as specified and directed.
22
-
-
... More
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
50
-
-
... More
M&L 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded aggregate as in sub base,complete all as specified and directed.
40
-
-
... More
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
12
-
-
... More
Cement Concrete in sub floor, floor, bases, sub bases 40 mm thick Type B-0(1:2:4) using 12.5mm graded aggregate complete all as specified and directed.
120
-
-
... More
Demolition of brick work built in cement mortar complete all as specified and directed.
10
-
-
... More
M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus complete all as specified and directed.
10
-
-
... More
M&L for 15 mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directed.
40
-
-
... More
S&F Street Light Junction box (IP-55) suitable for mounting on LT RCC pole/steel tubular pole, box having single phase aluminium busbar 20 Amp rating with 6 Amp MCB ('B' series) control, mounted on insulators with 2 clamps of Aluminium strip for earthing of the armoured of the cable complete with making holes for connecting cables etc nuts bolts etc front openable hinged cover suitable for mounting on steel clamps nut bolt etc pvc adopters and PVC hose pipe upto cable treench for incoming and outgoing cables, factory made duly painted with powder coating process complete all as specified and directed.