Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 32,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_279652_2Bid Award Id
ViewTender No
802019/GE-49/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Complete cleaning and removing blockage from WC to first manholes, Nahani/floor traps to gully trap and from gully trap to first manholes by well flushing with adequate water including opening and re-fixing gully trap covers, access doors of junctions/bends with bolts or cement joints as per site conditions for any dia and type of pipes & fittings complete all as directed (cleaning from WC to 1st MH, NT to GT and GT to MH shall be treated as separate units and shall be measured and paid for separately as per site requirement).
10000
-
-
Taking down cement plaster from inside/outside of existing septic tank/manhole/walls etc including racking out joints, hacking for key scrubbing down with water and removal of rubbish off the premises complete all as directed.
90
-
-
M and L for 15 mm thick rendering in cement mortar 1:4 inside and outside wall of manhole of brick work/ concrete surface and finishing even and smooth without using extra cement mortar as per manufactures instructions complete all as specified & as direcetd.
Note: (i) WPC shall be measured and paid for separately as 'Supply only'.
(ii) WPC to be mixed @200ml per 50 Kg bag of cement all as manufacturers instruction.
190
-
-
Supply only integral water proofing compound complete all as directed.
9
-
-
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 200 mm complete all as directed.
2
-
-
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as directed.
3
-
-
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 300 mm complete all as directed.
10
-
-
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 200 mm complete all as directed.
30
-
-
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 150 mm complete all as directed.
100
-
-
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 300 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
10
-
-
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 200 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
30
-
-
M & L for PCC 1:3:6 type C2, (using 40 mm graded aggragate) as in concrete bed to 150 mm bore drain pipe including packing under and hunching against the sides of pipes after pipe laid and tested complete all as directed.
100
-
-
M&L for 300 mm borw reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
10
-
-
M & L for 200 mm bore (internal dia of pipe) salt glazed stoneware drain pipe grade A laid in trenches and jointed complete all as directed.
30
-
-
M & L for 150 mm bore (internal dia of pipe) salt glazed stoneware drain pipe grade A laid in trenches and jointed complete all as directed.
100
-
-
Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
70.2
-
-
Excavation in trenches n. exc. 1.5 mtr wide and exc. 1.5 mtr but n.exc. 3.00 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
23.4
-
-
Excavation in trenches n exc. 1.5 mtr wide and exc. 3.00 mtr but n.exc. 4.50 mtr depth for cesspits, manholes etc. and getting out soft/loose soil even in foul position complete aii as specified and as direcetd.
23.4
-
-
Returning, filling including spreading leveling watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as directed.
52.65
-
-
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed.
64.35
-
-
Dismantling PVC pipe alongwith fittings of 75/100mm dia, below or above ground level or laid in floors, jointed in cement mortar and taking out complete all as specified.
70
-
-
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes , complete all as specified.
40
-
-
S&F 110 mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified.
10
-
-
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including distance pieces and stack clamps as in rain water pipes , complete all as specified.
30
-
-
S&F 75 mm bore PVC (SWR) bends/shoe any radius fixed to walls including distance pieces and stack clamps complete all as specified.
10
-
-
S&F 110 mm bore PVC(SWR) branch piece,single( single y) equal or unequal
10
-
-
S&F 110 mm bore PVC(SWR) branch piece,double( double y) equal or unequal
8
-
-
S&F 110 mm bore PVC(SWR) juction single T equal or unequal
8
-
-
S&F110 mm bore PVC(SWR) reducer
10
-
-
S&F 75 mm bore PVC(SWR) cowl
10
-
-
Dismantling 100 mm internal dia cast iron pipe, jointed in cement mortar upto 04 storeys including all scafolding arrangments complete all as specified and directed.
8
-
-
Dismantling 75 mm internal dia cast iron pipe, jointed in cement mortar upto 04 storeys including all scafolding arrangments complete all as specified and directed.
6
-
-
Supplied and fixed to walls 100 mm nominal bore dia Cast iron sand cast soil,waste and vent pipes, in any length with or without ears, with cement mortar joints upto 04 storeys including all scafolding arrangments complete all as specified and directed.
8
-
-
Supplied and fixed to walls 75 mm nominal bore dia Cast iron sand cast soil,waste and vent pipes, in any length with or without ears, with cement mortar joints upto 04 storeys including all scafolding arrangments complete all as specified and directed.
6
-
-
Supplied and fixed 100 mm bore bends (any radius), diminshing pieces or tapers (larger bore measured.
5
-
-
Supplied and fixed 100 mm bore branch pieces, single (equal or unequal) ordinary or inverted)( spigot and socket type) or with parallel branches complete all as specified and directed.
4
-
-
Supplied and fixed 75 mm bore bends (any radius), diminshing pieces or tapers (larger bore measured.
5
-
-
Supplied and fixed 75 mm bore branch pieces, single (equal or unequal) ordinary or inverted)( spigot and socket type) or with parallel branches complete all as specified and directed.
4
-
-
S&F 100 mm cast iron sanitary connection socket to fit WC outlet complete all as specified and directed.
3
-
-
Dismantling brickwork of stone/boulder masonry, build incement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
14
-
-
Material and labour for brick work with sub class 'B' brick straight curved on plan exceeding 6 metre mean radius with old size bricks built in CM 1:6 for cracked wall of manholes,septic tank, soak pits etc complete all as specified and directed.
12
-
-
All as per item No-24 here-in -above but except bricks complete all as specified and directed. Note :- Old serivceable bricks obtained from Srl No 23 shall be reused after proper cleaning.
2
-
-
Providing cement concrete type B1 1:2:4 (20 mm graded aggregate) as in copings to brick wall, kneelers,bedplates and all other similar works including necessary form work complete all as specified and directed.
2
-
-
Demolition of cement cocrete (unreinforced) not exceeding 15 cm thickness (above or below ground level) complete all as directed.
4
-
-
M&L for PCC (1:3:6), type C2 (40 mm graded aggregate ) in foundation filling and mass concrete for bottom of manhole complete all as specified and directed.
2
-
-
M&L for PCC (1:4:8), type C2 (40 mm graded aggregate ) in foundation filling and mass concrete all as specified and directed.
2
-
-
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.
50
-
-
Demoletion of reinforced cement concrete (reinforcement cut as required to facilitate demoletionof any description and in any position not otherwise specifically provided for complete all as specified and directed.
2
-
-
M&L for RCC(1:2:4), type B1 (using 20 mm graded stone aggregate) precast cement concrete cover slab for manhole and similar article with plain face, set in cement mortar 1:4 complete all as specified and direceted.
2
-
-
S&F deformed or twisted TMT bars 8 mm dia cut to length bent to shape required including cranking binding with MS wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
270
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements