Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair And Cleaning Of Sewage Line, Septic Tank, Manholes Including Day To Day Complaint And Certain Misc Work In Otm Accn Under Zone M Under Age Br-v Of Ge (n) Btd At Bathinda Mil Stn
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_664475_2Tender No
8939/NIT-35/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Cleaning and desilting of sewage lines 150 mm to 250 mm dia of any size at any depth by pumping out /removing liquid waste/sewage ,plugging the ends pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinkling bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and flushing the sewer lines with fresh water etc complete all as specified and directed by Engr-in-Charge.
Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
500
-
-
Cleaning and desilting of manholes depth not exceeding 1.50 meter by pumping out/removing liquid waste/sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinking bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside of MD land all as per existing rules and regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge . Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
75
-
-
Cleaning and desilting of manholes depth exceeding 1.50 m but not exceeding 3.00 m by pumping out/removing liquid waste/sewage and plugging the ends of sewer pipes or diverting the flow into drains if necessary, removing silt, sludge etc, sprinkling bleaching powder on the silt to avoid bad smell including all precautionary and safety measures, such as safety belts, lighting arrangements face mask etc and removing the same(silt,sludge &other waste material) in leak proof trucks covered with tarpoline to outside MoD land all as per existing rules & regulations of civil authorities and cleaning the manholes with freah water etc complete all as specified and directed by Engr-in-Charge.
Note :- (a) If required getting a honey sucker and cleaning the heavily congested sewage line. (b) JCB and other machinery required on special basis would be called on requirement basis.
50
-
-
Cleaning the chocks/blockades in AC/CI/PVC soil waste/rain water pipe of any dia and collar, bend etc by removing cleaning eye and refixing the same after cleaning the pipe, making good damaged cement joints, dia of pipe not exc 150mm dia upto ground/stilt plus four floors including necessay scafolding complete all as specified and directed by Engr-in-Charge.
300
-
-
Empting choked up sewage lines and manholes exceeding 3.00 mtr depth by providing sewage suction vehicle of capacity 5000 ltrs (BMC Pattern) including other necessary arrangments such as sweepers to clean up the site after work and desposing the same at places earmarked outside MOD land upto 25 KM lead and lift complete all as specified and directed.
Note :- (a) All precautions to be taken by all workers while working in foul condition. Contractor shall take all necessary actions. (b) After cleaning vehicle will be contractors property. (c) Contractor accredited representative shall be available during the cleaning. (d) Complete process shall be completed in all respects within a day.
15
-
-
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 200 mm complete all as specified and directed.
15
-
-
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC1:2:4 type B1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed.
15
-
-
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
350
-
-
Excavation in trenches, not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
200
-
-
Supply and laying of Reinforced concrete pipes, class NP3, 200 mm dia/bore, with collars laid and jointed including complete demolition of existing pipes all as specifed and directed.
100
-
-
Supply and laying of Reinforced concrete pipes, class NP3, 150 mm dia/bore, with collars laid and jointed including complete demolition of existing pipes all as specifed and directed.
350
-
-
Supply and fixing for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 150 ID mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions complete including demolition of existing line all as per specified and directed. (Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting etc.)
100
-
-
Supply and fixing for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 200 ID mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions including demolition of existing pipe complete all as per specified and directed.(Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting etc.)
100
-
-
Material and labour for cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in bed of drain pipe of size 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
430
-
-
Material and labour for cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate as in bed of drain pipe of size 200mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
185
-
-
Returning, filling including spreading, leveling, watering and well ramming in layers n. exc 25 cm in soft/loose soil complete all as directed.
425
-
-
Removing excavated soil to a distance n. exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as directed.
125
-
-
Material and labour for brick work with sub class 'B' brick straight curved on plan exceeding 6 metre mean radius with old size bricks built in cement mortar 1:6 for cracked wall of manholes,septic tank, soak pits etc complete including demolition all as specified and directed.
30
-
-
Material and labour for brick work with old sub class 'B' bricks (except bricks) straight curved on plan exceeding 6 metre mean radius with old size bricks built in cement mortar 1:4 for cracked wall of manholes, septic tank, soak pits etc complete all as specified and directed.
Note :- Seriviceable bricks obtained from demolition of brick work vide srl item No. 20 & 21 shall be reused.
2
-
-
Material and labour Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete masonry walls, finished even and fair without using extra cement and using water proofing compound as per manufacturer's instructions complete all as specified and directed.
Notre- (i) WPC shall be measured and paid for separately as 'Supply only'.
180
-
-
Supply only integral water proofing compound.
19
-
-
Material and labour Rendering 15mm thick plaster in cement mortar 1:4 on brick or concrete masonry walls, finished even and fair without using extra cement complete all as specified and directed.
100
-
-
Material and labour for cement concrete 1:2:4 type B0, (using 12.5 mm graded stone aggregate) as coping/cills including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
2
-
-
Material and labour for PCC (1:3:6), type C2 (40 mm graded aggregate ) in foundation filling and mass concrete for bottom of manhole including demolition of existing PCC complete all as specified and directed.
2
-
-
Material and labour for PVC (SWR) multi floor trap in repair with grating including jointing with solvent cement for diameter of 75 mm outlet complete all as directed.
15
-
-
Supply and fixing PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement/adhesive including dismantling of existing gully trap with chamber and making new chamber with PCC 1:2:4 type B1 covered with RCC cover complete all as specified and directed.
25
-
-
Supply and fixing 75mm bore of pipe PVC (SWR) type B pipes single socket in any length with rubber ring joint fixed to walls with GI clamps/ Brackets at a distance of 100-120mm away from walls as directed by eineer in charge.
90
-
-
Supply and fixing 110mm bore of pipe PVC (SWR) type B pipes single socket in any length with rubber ring joint fixed to walls with GI clamps/ Brackets at a distance of 100-120mm away from walls as directed by eineer in charge.
940
-
-
Supply and fixing 75mm dia PVC (SWR) bends with access doors any radius.
10
-
-
Supply and fixing 110 mm dia PVC (SWR) bends with access doors any radius.
45
-
-
Supply and fixing 75 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door complete all as specified and directed.
5
-
-
Supply and fixing 110 mm dia PVC (SWR) junction single, (single T) equal or uequal provided with access door complete all as specified and directed.
25
-
-
Supply and fixing 75mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
10
-
-
Supply and fixing 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and directed.
40
-
-
Supply and fixing 75 mm PVC (SWR) branch piece, single (double Y) equal or unequal complete all as specified and directed.
10
-
-
Supply and fixing 110mm PVC (SWR) branch piece, single (double Y) equal or unequal complete all as specified and directed.
30
-
-
Supply and fixing 75 mm dia PVC (SWR) vent cowl.
10
-
-
Supply and fixing 110mm dia PVC (SWR) vent cowl.
20
-
-
Supply and fixing in repairs 900mm x 600mm FRP manhole cover of 8 tonne loading capacity with frame over manhole coping concrete complete all as specified and directed.
50
-
-
Supply and fixing cast iron manhole covers alongwith frame grade A-35 T/A-350 KN, machined each exceeding 5 Kg by weight complete all as specified and directed by EIC.
50
-
-
Material and labour for pre cast RCC Cylindrical manhole System of size (top dia- 560mm, bottom dia-1200mm) upto depth of 3.0 metre with manhole cover including necessary excavation, earth work and removal of surplus soil to a distance 50 metre complete all specified and directed by engineer in charge.
15
-
-
Material and labour for pre cast RCC Cylindrical manhole System of size (top dia- 560mm, bottom dia-1000mm) upto depth of 1.80 metre with manhole cover including necessary excavation, earth work and removal of surplus soil to a distance 50 metre complete all specified and directed by engineer in charge.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%