Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 77,660Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694183_1Tender No
CWE/PAT/T-65/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 1.5 Sqmm (nominal area), FRLSH,PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit(thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators and white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell point controlled by one bell push (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.
32
-
-
... More
All as per Item No. 4.00 here in before but for One three pins 5 Amps switch socket outlet point on independent board etc complete all as specified and as directed by Engineer-in-charge.
5
-
-
... More
All as per Item No. 4.00 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches etc complete all as specified and as directed by Engineer-in-charge.
5
-
-
... More
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 2.5 Sqmm (nominal area), FRLSH, PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit (thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets and white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for 16 Amp socket outlet (Wiring shall be done as per colour code in IS for phase, neutral and earth) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.
15
-
-
... More
Supply and fix Ceiling fan with BLDC technology AC single phase 240 Volt 50 Hz of size 1200 mm sweep 5 star rated without remote but with compatible electronic regulator complete in white colour having service value more than or equal to 6 with canopy, hanging rod and all accessories incl nuts, bolts, clamps etc including making connections with twisted 3 core PVC insulated unsheathed flexible cord of 0.75 sqmm copper conductor from ceiling rose to ceiling fan, complete all as specified and directed
7
-
-
... More
Supply and fix Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed.
1
-
-
... More
Supply and fix MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed
3
-
-
... More
Supply and fix MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed
10
-
-
... More
Supply & fix LED mirror light with Linear & compact 9W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser of capacity 9 watt. complete all as specified and directed.
1
-
-
... More
Supply and Fix new generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed
8
-
-
... More
Material & Labour for earthing complete with galvanized steel earth plate electrode 60×60cm×6mm thick electrode burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1, using 20 mm graded stone aggregate, provn of 40 mm RCC with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade GI pipe for watering, 40 mm dia light grade Gl pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-I (2009) connected to earthing test point all as specified and indicated including testing on completion including retrieving of old GI earth plate, CI cover, GI pipes, angle iron frame from existing earthing as directed by Engineer-in-Charge. NOTE : - (i). Earthing strip GI/copper upto 7.5m will be measured and paid under this item only. (ii). The earth chamber shall be constructed 50 cm away from the edge of earth pit and the cost of the same is deemed to be included in the rate quoted for above item. (ii). Quoted rate is deemed to be inclusive of cost of demolition of old earthing as directed by Engr-in-Charge. (iii). The new earthing so constructed must have resisitance value below 2 ohms. If the aforesaid resistance value is not achieved contractor has to make proper aadditions/alterations to the newly constructed earthing at his own cost.
4
-
-
... More
Supply and fix surface mounted LED luminaire with more light distribution and clutter free ceilings of 20 watt suitable for mouniting on roof.all as specified and directed
5
-
-
... More
Supply and fix Exhaust fan AC single phase 230/240 v of size 300 mm sweep heavy duty 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver ,making holes, grouting nut-bolts complete all as specified and directed
2
-
-
... More
Supply and Fix Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed
3
-
-
... More
Supply and fix LED tube light fittings 1 x 20 W, 4 feet long 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as directed by Engr-In- Charge.
14
-
-
... More
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. all as specified & directed
1
-
-
... More
Material & Labour for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed. Note 1:- 2 Runs of 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 4.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc. 10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring.
30
-
-
... More
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed
1
-
-
... More
Supply and fix Sheet metal enclosure 4 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed
2
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “INTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - III (Part-I)
1
12961
-
... More
Sch 'A' Sec - III (Part-II), “INTERNAL WATER SUPPLY WORK"
-
-
-
... More
Supply & Fix central hole basin mixer fancy type, cast copper alloy, with capstan heads, chromium plated screwed down, high presssure with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe complete all as specified and directed
1
-
-
... More
Supply & Fix Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe of 15mm bore and fixed complete all as specified and directed
1
-
-
... More
Supply & Fix 40mm dia PVC corrugated flexible waste pipe of 750mm long including nut washer cup bracket complete all as specified and directed
2
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “ROAD, PATH & HARD STANDING WORK" as listed in Schedule ‘A’ Section -IV (Part-I)
1
8514
-
... More
Sch 'A' Sec - IV (Part-II), “ROAD, PATH & HARD STANDING WORK"
-
-
-
... More
Material and labour for machine pressed precast concrete interlocking paver block rubber moulded any shape and size with grey cement and no pigment confirming to IS 15658-2006 of 60 mm thickness M-35 Grade. pre-polished & pre-glazed, confirming to relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over 75mm thick PCC 1:4:8 type D-2 and including 25mm thick layer of sand cushioning and filling the interstices etc with sand complete all as specified and as directed.
112
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - V (Part-I)
1
11732
-
... More
Lump sum price worked out by the tenderer for “SEWAGE DISPOSAL WORK" as listed in Schedule ‘A’ Section - V (Part-II)
1
135668
-
... More
Material and labour for RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:2:4 below foundation, RCC M-25 in slabs/Walls, Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete with effective depth of 1.3 meter and overall depth of 3 meter up to 20 users as per Chief Engineer Chandigarh Zone TD Drg No STD 1320 (C) complete all as specified and directed..
1
-
-
... More
Material and labour for Soakage wells excavation in any type of soil, foundation in PCC 1:4:8, walls of honey combed masonry with top ring of M-25 concrete, RCC cover slab of M-25, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth as per Chief Engineer Chandigarh Zone TD Drg No STD 1173 (C) complete all as specified and directed.
1
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “FENCING AND GATE WORKS" as listed in Schedule ‘A’ Section - VI (Part-I)
1
530302
-
... More
Lump sum price worked out by the tenderer for “EXTERNAL WATER SUPPLY WORKS" as listed in Schedule ‘A’ Section - VII (Part-I)
1
132637
-
... More
Sch 'A' Sec - VIII (Part-II), (EXTERNAL WATER SUPPLY WORKS)
-
-
-
... More
Material and labour for taking out branch connection from existing CI/DI pipe line upto 250 mm bore by using ferrule including insertion of TEE of 50x50x25 mm etc complete all as specified and directed..
1
-
-
... More
Material and labour for construction of brick masonary pits of internal dimensions 0.9 mtr x 0.9 mtr x 0.9 mtrs ( bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of gate valve to provide sufficient working space) , bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The gate valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet 3.15 mm thick witth angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with galvanised steel hindges two nos ,and locking arrangements duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide as specified and directed
1
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIFICATION WORKS" as listed in Schedule ‘A’ Section - VIII (Part-I)
1
7604
-
... More
Sch 'A' Sec - VIII (Part-II), (EXTERNAL ELECTRIFICATION WORKS)
-
-
-
... More
Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed.
10
-
-
... More
Material & Labour for boring of holes under road pavement hard standing by trench less technology using ultra sound technique and necessary machine suitable to pass through 40 to 80 mm bore GI tubing and cable etc complete all as specified and directed.
Note: GI pipe shall be measured and paid separately under relevant item.
18
-
-
... More
Material & Labour for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric LT cables (heavy duty) 16 sqmm 4 core ,earthed system, stranded aluminium conductor including cable glands, cable lugs etc, to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified
300
-
-
... More
Material & Labour for sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes)
17
-
-
... More
Supply and fix Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-54 protection complete all as specified and directed .
1
-
-
... More
Supply and fix MCB C curve, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed
1
-
-
... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning. SPN 40 to 63 amp complete all as specified and directed
4
-
-
... More
Material and labour precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
1401
-
-
... More
Subtotal
-
-
-
... More
Lump sum price worked out by the tenderer for “EXCAVATION, EARTHWORK AND SITE CLEARANCE DEVELOPMENT WORK" as listed in Schedule ‘A’ Section - IX
1
81065
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%