Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680690_1Bid Award Id
ViewTender No
GES/PKT/51/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified and directed.
145
-
-
Supply and laying sub class 'B' bricks of (230x115x75 mm) or of size locally available , laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
10000
-
-
Laying only old bricks retrieved from item No. 7 here-in-after of any size/type laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
5000
-
-
Taking up the existing cables from trenches of any size any type all as specified and directed by Engr-in-Charge.
2270
-
-
Supply and lay cable XLPE insulated armored heavy duty electric cable with aluminum conductor, 1100 volts grade of cross sectional area 16 Sq mm 2 core complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushioning , cable protection cover, GI protection pipe shall be measured and paid for separately under respective item of Schedule
150
-
-
All as per item No. 8 here-in-before but of size 400 Sqmm 3.5 core
80
-
-
All as per item No. 8 here-in-before but of size 16 x 04 core
200
-
-
All as per item No. 8 here-in-before but of size 25 Sqmm 4 core
150
-
-
All as per item No. 8 here-in-before but of size 35 Sqmm 3.5 core
200
-
-
All as per item No. 8 here-in-before but of size 50 Sqmm 3.5 core
200
-
-
All as per item No. 8 here-in-before but of size 70 Sqmm 3.5 core
200
-
-
All as per item No. 8 here-in-before but of size 95 Sqmm 3.5 core
300
-
-
All as per item No. 8 here-in-before but of size 120 Sqmm 3.5 core
200
-
-
All as per item No. 8 here-in-before but of size 150 Sqmm 3.5 core
120
-
-
All as per item No. 8 here-in-before but of size 185 Sqmm 3.5 core
200
-
-
All as per item No. 8 here-in-before but of size 240 Sqmm 3.5 core
120
-
-
All as per item No. 8 here-in-before but of size 300 Sqmm 3.5 core
150
-
-
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 10 to 16 Sqmm 2/4 core with working voltage 1100 volts, complete all as specified and directed.
6
-
-
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 25 to 50 Sqmm 3.5/4 core with working voltage 1100 volts, complete all as specified and directed.
10
-
-
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed.
4
-
-
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 150 to 185 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed.
4
-
-
Material, labour , testing & commissioning of straight through jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 240 to 300 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed.
2
-
-
Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 16 to 50 Sqmm 3.5/4 core with working voltage 1100 volts, complete all as specified and directed.
50
-
-
Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 70 to 120 Sqmm 3.5 core with working voltage 1100 volts .
30
-
-
Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 150 to 185 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed.
20
-
-
Material, labour , testing & commissioning of indoor End jointing kit, heat shrinkable type suitable for XLPE/ PVC cables of size 240 to 600 Sqmm 3.5 core with working voltage 1100 volts, complete all as specified and directed.
10
-
-
M&L for GI pipe light grade 40 mm dia for cable protection on road crossings /plinth protection with fixed to the pole or wall etc including suitable fittings for cable protection complete all as specified and directed.
50
-
-
Material and labour for GI tubing light grade 80 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole including fittings complete all as specified and directed.
30
-
-
All as per srl item No 31 here-in-before but 50mm bore
50
-
-
Supply and erecting in true vertical or to be planed as strut, steel tubular swaged welded pole complete with MS base plate final taper plug, bolt, nuts & screw, 6mm thick of size 300mmx300mm welded at the centre of the pole, type 410 SP-31 (09 Mtr long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zinc chrome primer and two coats of aluminum paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three black and three white bands at lower portion of pole each of 300mm height at 300mm spacing complete all as specified incl dismantling old one complete all as directed and specified. NOTE :- Earth work, Cement concrete in foundation, coping etc. will be measured and paid separately under relevant item.
10
-
-
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded copper conductor cable for connecting OH line/junction box to street light fitting, testing and commissioning complete all as specified and directed.
300
-
-
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and directed.
4.5
-
-
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and directed.
1
-
-
M & L for disconnecting burnt end or portion of UG Cable, removing the cable from loop or trench including necessary excavation and earth work, relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminal by replace with new cable joint kit for cable of cross sectional area 10 Sqmm 4 core to 300 Sqmm 3.5 core of LT cable to pole, main switch, LT Panel etc. complete all as specified and as directed Note :- Cable joints and cable will be measured separately under respective item of schedule.
80
-
-
Supply and Fixing in Replacement for 350 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
1
-
-
Supply and Fixing in Replacement for 250 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
1
-
-
Supply and Fixing in replacement for 200 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
1
-
-
Supply and Fixing in Replacement for 160 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and Fixing in Replacement for 100 AMP MCCB, 3 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and Fixing in Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and Fixing in Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and Fixing in Replacement for 200 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 25 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and Fixing in Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 16 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
4
-
-
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc. complete all as specified and directed.
5
-
-
Supply, installing, testing and commissioning of LT feeder pillar box factory made outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN), including provn of following :- Note : (a) The panel shall be as per CPRI certificate (b) Rates inclusive of PCC complete
i) Aluminium Bus bar 400-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation
ii) MCCB 4 Pole , 200 Amp, 415 V, 36 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 01 No (incommer) Iii) MCCB 4 Pole , 125 Amp, 415 V, 25 KA (Thermal magnetic release) adjustable overload setting 80% to100%- 03 Nos (iv) MCB SPN 6-32 A -04 Nos v) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 No vi) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selection switch - 01 No vii) RYB LED indicator- one set
1
-
-
Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 40 x 40 x 6mm , 45 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire weather proof, with IP-66 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN), including provn of the following:- Note: (a) The panel shall be as per CPRI certificate. (b) PCC will be measured and paid separately. i) Aluminium Bus bar 400 A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation ii) MCCB 4 pole 415 V 3 phase 250 Amp, 36 KA (Thermal magnetic release) - 01 No (incoming) ii) MCCB 3 pole 415 V 3 phase 160 Amp, 25 KA (Thermal magnetic release) - 02 Nos (outgoing) iii) MCCB 3 pole 415 V 3 phase 100 Amp, 25 KA (Thermal magnetic release) - 02 Nos (outgoing) vi) Digital Voltmeter of size 96x96mm 0-500 volts with selector switch - 01 No vi) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selection switch - 01 No vii) RYB LED indicator- one set
2
-
-
Supply installing, testing and commissioning of LT feeder pillar box factory made Outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 65 x65 x 6mm, 45 cm height, dust and vermine proof, suitable for voltage 415 separate hinge door for each compartment for incoming and outgoing MCCB etc. with locking arrangement, with back door openable screwed, legs grouted in PCC including painting with two coats of epoxy powder paint over a coat of primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with aluminum busbar (TPN), including provn of following :- Note : (a) The panel shall be as per CPRI certificate (b) Rates inclusive of PCC complete i) Aluminium Bus bar 600-A- mounted on porcelain insulator - 01 Set ( Set of 4 Nos) with PVC sleeve insulation ii) MCCB 4 Pole ,400 Amp, 415 V, 36 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) iii) MCCB 4 Pole , 250 Amp, 415 V, 36 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 02 Nos (outgoing) iv) MCCB 4 Pole , 160 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 03 Nos (02 OG + 01 SB) v) MCCB 4 Pole , 63 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (Outgoing)
vi) Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch - 01 No vii) Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selection switch - 01 No viii) RYB LED indicator- one set
2
-
-
Supply, installation, testing and commissioning of LT panel outdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 200 Amp, MCCB 4 Pole , 100 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) & RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copper conductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated painting in inner & outer side, including making all suitable necessary electrical connection complete all as directed by the Engineer -in - Charge. Note : (i) The panel shall be as per CPRI certificate. (ii) The rates deemed to be inclusive necessary PCC for grouting of panels.
2
-
-
Supply, installation, testing and commissioning of LT panel outdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 300 Amp, MCCB 4 Pole , 200 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) & RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copper conductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated painting in inner & outer side, including making all suitable necessary electrical connection complete all as directed by the engineer –in - charge. Note : (i) The panel shall be as per CPRI certificate. (ii) The rates deemed to be inclusive necessary PCC for grouting of panels.
2
-
-
Supply, installation, testing and commissioning of LT panel outdoor type suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, made out 3.15 mm thick CRCA sheet with angle iron frame of size 80 x 80 x 6 mm cubical type complete with 4 Nos Aluminium bus bar 400 Amp, MCCB 4 Pole , 250 Amp, 415 V, 25 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100%- 01 No (incommer) & RYB LED indicator- one set with IP 54 as per IS 13947 protection, internal wiring by FRLS grade multi stranded PVC insulated copper conductor of size not less than 10 Sq.mm duly marked with ferrule, incl powder coated painting in inner & outer side, including making all suitable necessary electrical connection complete all as directed by the engineer –in - charge. Note : (i) The panel shall be as per CPRI certificate. (ii) The rates deemed to be inclusive necessary PCC for grouting of panels.
2
-
-
S&F in repair Capacitor duty contactor with 1 No Aux contact 230V AC coil voltage suitable for minimum 10 KVAR capacitor complete all as specified and directed.
2
-
-
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 3 to 15 KVAR complete all as specified and directed.
5
-
-
S&F in repair Double metalised paper and polypropylene technology ( Mixed Dielectric) capacitor cylindrical/box type for power factor correction of 440 V, 50 HZ rated of capacity 20 to 25 KVAR complete all as specified and directed.
4
-
-
M&L in replacement of existing unserviceable contactor of current carrying range 25 A to 40 Amp (AC-3 duty) at different places in APFC panels/other electric panel including required electrical connections with suitable size of single core pvc copper cable & testing complete all as specified and directed.
5
-
-
M&L in replacement of existing unserviceable contactor current carrying range 9 to 18 Amp (AC-3 duty) at different places in APFC panels/other electric panel including required electrical connections with suitable size of single core pvc copper cable & testing complete all as specified and directed.
5
-
-
S&F in repair APFC relay with inbuilt PF meter suitable for 5A CTR suitable for 8 Stage complete all as specified and directed.
1
-
-
Restretching of ACSR conductor of any size of over head lines LT on poles including binding with insulators, jointing jumpers etc. including connections of incoming and out going cables complete all as specified and directed. Note: ACSR conductor Required for winding etc. to be included in quoted rates.
30
-
-
Dismantling unserviceable cross arms including clamps, bolts, nuts, washers etc. from pole complete all as specified and directed.
0.5
-
-
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
0.5
-
-
Dismantling of ACSR conductor of any size, from insulator etc. from the structure/over head line all as directed.
0.5
-
-
M&L for ACSR conductor of any size as ordered by Engr-in-charge including tightening and binding with new binding wires to insulators all as directed.
0.5
-
-
Dismantling insulators of any type, size
60
-
-
M&L for pin type insulator vitreous, white, brown, or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade.
30
-
-
M&L for Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanized mild steel straps of section 31 x 3mm, washers, insulator bolts(dia 12 mm), washers and nuts,75 mm height, 90 mm dia for 1100 volts grade.
20
-
-
M&L for stay assy complete with MS stay plate of size 300x300x6mm thick, stay rod 16mm dia, stay bow, nuts, bolts and check nuts of GI all as shown in EP No 01 of SSR complete all as or directed by Engr-in-charge ( Excavation, PCC, and loop type insulators will be measured separately).
10
-
-
M&L for loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green.
10
-
-
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 2500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 30 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed .
5
-
-
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed.
5
-
-
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 70/72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed.
10
-
-
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with Glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed.
10
-
-
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed.
10
-
-
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete all as specified and as directed.
15
-
-
M& L for repair the broken/fallen and loose fencing around transformer/panel/bus bar including replacing the broken iron angle, gate and required PCC for fixing the angle and gate and repaint all as specified and directed by Engr-in-Charge.
2
-
-
S& F in replacement Anti-climbing device; spikes type fabricate out of M.S bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of pole all as specified and directed by Engr-in-Charge.
0.3
-
-
S&F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engr-in-Charge.
5
-
-
M & L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by Engr-in charge.
3
-
-
M & L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by Engr-in-Charge.
3
-
-
M&L for Earthing complete with galvanized cast iron earth plate electrode of size 600x600x6 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanized iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSR complete all as specified and directed by Engineer-in-charge incl testing on completion.
10
-
-
Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 200 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified
1
-
-
Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 400 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified
1
-
-
Supply and fixing in repair onload change over switch 04 Pole, confirming to IEC 947-E, EN-60947-3, AC -23A front operated, 415 V, 50 HZ of capacity 800 A front handle including dismantling the old burnt out change over switch, fixing complete with suitable lugs, testing complete all as directed and specified
1
-
-
M&L for preparation of old painted surfaces of LT electrical panel/Bus Bar chamber incl removing oily/greasy spots & rusting and cleaning internally and applying two coats of epoxy powder paint over a coat old primer after alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate complete all as specified and directed by Engr-in-Charge.
10
-
-
S&F in repair Digital Voltmeter of size 96x96mm rating 0-500 volts with selector switch complete all as specified and directed.
5
-
-
S&F in repair Digital Amp meter of size 96x96mm rating 0-1000 Amp with CT's & selector switch complete all as specified and directed.
5
-
-
S&F in repair R,Y,B indicator lamp for LT Feeder panel/Bus Bar chamber complete all as specified and directed.
10
-
-
Supply and fix in repair 20 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed.
100
-
-
Supply and fix in repair 25 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed.
100
-
-
Supply and fix in repair 32/40 mm dia HDPE flexible pipe for covering open electrical wire etc. , black colour complete all as specified and directed.
100
-
-
S&F loop-in/loop-out box of outer size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc. complete in the box, duly fixed to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.
30
-
-
Supply and fixing in replacement of MCB SP 6-32 Amps, 10 KA breaking capacity , 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
50
-
-
Supply and fixing in replacement of MCB SPN 32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
30
-
-
Supply and fixing in replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
25
-
-
Supply and fixing in replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
20
-
-
Supply and fixing in replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
20
-
-
Supply and fixing in repair of industrial change over switch gear 200 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc. complete all as specified and as directed by Engr-in-Charge.
1
-
-
Supply and fixing in repair of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc. complete all as specified and as directed by Engr-in-Charge.
1
-
-
Supply and fixing in repair of industrial change over switch gear 250 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc. complete all as specified and as directed by Engr-in-Charge.
1
-
-
Supply and fixing in repair for 800 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
1
-
-
Supply and fixing in repair for 630 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
1
-
-
Supply only PVC insulation tape roll of dimension 1.80 cm x 6.5m x 0.125 mm for jointing the connection etc. complete all as specified and directed.
200
-
-
Supply and fixing in repair for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and fixing in repair for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board complete all as specified and directed.
2
-
-
Supply and fix in repair 80 MM dia HDPE flexible pipe for covering open electrical wire etc. black colour complete all as specified and directed.
60
-
-
Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.
(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements