If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 47,00,000 
Notes
Download

Costs

Summary

Ges/pkt/47/2024-25 Repair/ Maint/ Renewal Of Perimeter Lights, Street Light, Security Lights, Post Top Lanterns, Garden Lights, Gate Lights Including Control Panels, Illumination Sys, Dg Set, Cranes And Misc Installations, External Fire Fightning Sys

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in repair new automatic street light timer switch for LED street light using infrared sensor based nature switch for automatic switching of street light 230 volt, single phase of cap 5-8 KW outdoor type factory made IP-65 protection having nature switch operating should be based on natural light flux level and selector switch to change the mode of operation supply indicator with including SMC box and locking arrangement. the sensor alongwith power contactor of Cap 63 Amp and incoming and outgoing MCB TPN Cap upto 63 Amp with auto manual operation and overvoltage and overcurrent protection and auto trip & auto reset making arrangement incl internal wiring of copper cable FRLS 10 Sqmm single core multistranded and mounted arrangement with clamp and nut bolt on wall/pole, dust proof and temper proof complete all accessories as required and provided by manufacturer complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Supply and fixing in repair Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting complete all as specified and directed.

58

-

-

... More
Supply and fixing in repair Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting complete all as specified and directed.

60

-

-

... More
Supply and fixing in repair Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting complete all as specified and directed.

70

-

-

... More
Supply and fixing in repair Surge protection device of capacity 10 KV suitable for LED light fitting complete all as specified and directed.

100

-

-

... More
Disconnecting from electric supply and remove from bracket/pole and dismantling LED light fitting of capacity 25 to 120 W, by strip opening the electronic driver, LED panel complete, identifying defective LEDs, make it functional by complete soldering, replacement of pitted control wiring from LED panel to driver etc. complete, including testing and commissioning all as specified and directed.

196

-

-

... More
Taking down old unserviceable security light fittings from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 2500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 30 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items.

65

-

-

... More
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

70

-

-

... More
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

75

-

-

... More
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72/70 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

64

-

-

... More
Taking down old unserviceable street light fittings from any height and Supply & fixing LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with lumen output not less than 9000 lumens suitable wattage for efficiency not less than 100 lumens/Watt, min wattage 90 watt, with ingress protection IP 65 and SPD of capacity 10 KV etc. complete and testing on completion all as specified and directed. Note: The GI pipe if required bracket will be measured and paid separately under relevant schedule items

50

-

-

... More
Taking down old unserviceable security light fittings roadway luminaire type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with PC cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway luminaire type with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

40

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed.

10

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed.

12

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc. incl necessary clamps etc. complete and testing on completion all as specified and directed.

15

-

-

... More
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100/120 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc. incl necessary, angle iron supports , clamps etc. complete and testing on completion all as specified and directed

15

-

-

... More
Supply & fix replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in soothing opal/ prismatic finish made up of polycarbonate, including all accessories prewired complete all as specified and directed. Note for serial item No. 10 to 20 :- (i) Minimum 2 years guarantee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9

49

-

-

... More
S&F in repair PVC insulated 3 core 1.0- 2.5 Sq mm stranded Copper conductor cable for connecting OH line/junction box to street light fitting testing and commissioning complete all as specified and directed.

300

-

-

... More
Cutting the tarmac / hard standings and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6, type C1 matching with the surroundings complete all as specified and directed.

2

-

-

... More
M&L for Earthing complete with Galvanized Steel earth plate of size 60x60cmx6.3mm thick electrode and GI wire 4 sqmm dia as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to earth wire 4 sqmm by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I, including testing on completion (Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, CI cover, funnel with watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).

30

-

-

... More
M&L for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc. complete including dismantling old defective.

20

-

-

... More
M&L for bracket for street light fitting made out of 25 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc. complete including dismantling old defective.

15

-

-

... More
M&L for preparation of old painted steel surfaces of 9 m long steel poles incl removing oily/greasy spots and applying one coat of aluminium paint complete including applying a coat of white wash on pole coping and lettering the pole details with white letters/ background etc. complete all as directed

15

-

-

... More
Repairs to High Mast/mid mast pole motor of Capacity 1.0 HP/0.75 KW 415 Volts 50 Hz 3 Phase 930 RPM and necessary rewinding with super enamelled copper wire all as per existing and servicing/greasing of reduction gear box complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Decarbonizing of the control panel of High mast/Mid mast and including servicing of parts such as contactors/timers including replacement of pitted lugs, thimbles, control wiring etc. complete including painting with a coat of synthetic enamel paint.

5

-

-

... More
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carrying capacity 32 to 40 Amps complete including control wiring thimbles etc. complete all as specified and directed.

2

-

-

... More
M&L for preparation of old painted surfaces of 9 m long PCC poles incl removing oily/greasy spots and applying one coat of synthetic enamel paint of black and yellow in alternate strips of 30 cm width upto 1.5 mtr height including applying a coat of white wash on pole coping and lettering the pole details with white letters/ background etc. complete all as directed

40

-

-

... More
S&F in repair powder coated Mild steel junction box with MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door , locking arrangements with 4 Nos Aluminum bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc. with suitable size flat iron clamps, nuts , bolts complete including taking down all as specified and directed.

50

-

-

... More
S&F in repair powder coated Mild steel junction box with MCB SP 03-10 Amps-01 No outdoor type , CRCA sheet with front openable hinged door , locking arrangements with 2 Nos Aluminum bus bars , 200 Amps, mounted on porcelain insulator, glands and lugs etc. and fixed to pole/ PTL post etc. with suitable size flat iron clamps, nuts , bolts complete including taking down all as specified and directed.

50

-

-

... More
Supply and fixing galvanized steel tube light grade of 15 mm dia, over the electric pole with the help of suitable size MS clamp, passing the service cable from the busbar to the light fitting through it, and making connection, of the cable to both the ends from bus bar to the light complete all as directed and specified.

150

-

-

... More
Supply and erecting in true vertical or to be planed as strut, steel tubular swaged welded pole complete with MS base plate final taper plug, bolt, nuts & screw, 6mm thick of size 300mmx300mm welded at the centre of the pole, type 410 SP-31(09 Mtr long) including drilling of holes of required size and nuts for fixing of cross arms, painting with coat of red oxide zinc chrome primer and two coats of aluminum paint on exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three black and three white bands at lower portion of pole each of 300mm height at 300mm spacing complete all as specified incl dismantling old one complete all as directed and specified. NOTE :- Earth work, Cement concrete in foundation, coping etc. will be measured and paid separately under relevant item.

5

-

-

... More
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete all as specified and directed.

3.01

-

-

... More
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work complete all as specified and directed.

0.47

-

-

... More
Repair, maint and making the fully functioning of flameproof electric operated crane of cap 2 Ton to 5 ton after checking long travell motion , cross travel motion , hoisting motion (electrically and mechanically) in presence of user rep and MES rep & rectify any type of defects immediately when found including servicing, greasing, top up gear box oil & carrying out routine maintenance as directed by Engineer in Charge. Note :- (i) any accessories found unserviceable that shall be replaced under respective items of this Sch. (ii) : Labor for lowering, mounting arrangement such as ladder , pulley block, rope system, T&P , any type nut, bolt, washers and other connected mechanism shall be contractor arrangement and rates are deemed to be included in this Job. No extra payment will be made to the contract against lowering/lifting the spare etc. at a height of 20' to 30' (iii) Repair/maint of each flame proof EOT crane of capacity 2 to 5 Ton (total 17 Nos) for two times or as per complaint of EOT cranes in a month.

40

-

-

... More
Dismantling the main driving shaft of forward/reverse drive of flameproof EOT crane after unscrewing nuts, bolts, washers including other connected accessories with shaft such as breaking assembly, coupling, bearings rings, gear box lowering down the smaller portion of shaft from up to 30' approximate height for removing and threading, repairing manufacturing cutting teeth keys one Nos bearing housing cabinet and replacement of one Nos tapper bearing welding of foundation rest pad making drills holes in rest pads matching with main foundation of trolly, cleaning, greasing and oiling of all the bearing, bearing housing, gear box etc. complete for smooth functioning including providing nut, bolts with locking arrangement & washers of any type/size as site requirement complete including re-assembly with connected accessories after repair including carrying out necessary alignment of all the parts connected with shaft all as specified and directed by Engineer-in-charge (Capacity of crane - 2 to 5 Ton )

6

-

-

... More
Dismantling of micro -up and down drive arrangement of flameproof EOT crane after un-screwing L- key bolts/screws nuts, washers etc. which includes gear box of micro drive main box of up -down drive, braking arrangements including dismantling of 3 set (3 pair) of micro coupling, micro-drive arrangement for under taking repair including getting down all as dismantled parts from existing platform at a minimum height about 20' to 30' approximately reassembling and re alignment all the parts complete including testing on load on both micro and main drive complete all as specified and directed by Engineer -in-charge. (capacity of Crane 2 to 5 Ton )

1

-

-

... More
Dismantling/strip opening gear of micro main shaft drive for replacement of 2 Nos gun metal bushes having internal lining for oiling arrangement, replacement of all the nuts/bolts of bush side plate with L-key, bolts of size as per sample oiling/greasing of gear box including necessary cast iron repair to broken foundation which includes welding lathing and grinding complete all as specified and directed by Engineer -in-charge. (Crane capacity 2 to 5 Ton )

2

-

-

... More
Dismantling and refixing after repair brake shoe leather suitable any motion of flameproof EOT crane 2 to 10 ton cap complete all as specified and directed Engineer in charge.

2

-

-

... More
Dismantling/strip opening flameproof micro drive box complete with rectifier transformer arrangement, magnetic disc both side coupling for remotting both the side ends of driving shaft (Gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and couplings (teeth system ) to avoid any kind of play in coupling and shaft including replacement of 4 Nos carbon bushes, replacement of 02 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive re-assembling/testing complete (crane capacity up to 5 Ton) all as specified and directed by Engineer -in-charge.

5

-

-

... More
Dismantling/strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, replacement of brake leathers, replacement of two Nos 440 volts any make brake coils, replacement of both gun metal bushes of shaft housing in brake box making oiling/greasing arrangement complete re-assembling and testing complete all as specified and directed by Engineer -in-charge.(Crane capacity 2 to 5 Ton )

4

-

-

... More
M&L for replacement coupling as per sample or approved by GE suitable for perfect alignment between flameproof motor and driven machine all as directed by Engineer in charge.

1

-

-

... More
M&L for replacement of L Key bolts 1" x 10mm as per sample or approved by GE including applying moose threads found worn out and taking out broken bolts from body/housing of machine for 2 to 5 ton capacity flameproof EOT Crane complete all as specified and directed by Engineer-in-charge.

1

-

-

... More
Dismantling/ lowering of burnt flame proof/weather proof three phase 440 volts , 50 Hz , 960 RPM , class F, 5 HP induction motor from platform complete including strip opening the same and rewinding with super enameled copper winding wire of same size /gauge as existing earlier complete including all backing material , insulation material and re- installation the same at original site complete all as specified and directed Engineer in charge.

5

-

-

... More
All as per serial item No. 46 here-in-before but capacity of motor 3 HP.

5

-

-

... More
M & L for of Power contactor 3 pole 16 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed by Engineer in charge.

4

-

-

... More
M & L for of Power contactor 3 pole 40 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed by Engineer in charge.

4

-

-

... More
M & L for of Over load relay 1.7 to 2.4 Amp as per sample or approved by GE complete all as specified and directed by Engineer in charge.

4

-

-

... More
M & L for of main bearing as per site requirement suitable for 2 to 10 Ton cap crane all as specified and directed by Engineer in charge

4

-

-

... More
M&L for brake oil suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation or directed by Engr In Charge. Make : Servo/HP/Castrol

20

-

-

... More
M&L for grease suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation or directed by Engr In Charge. Make : Servo/HP/Castrol

40

-

-

... More
S & F Thruster for flame proof EOT crane cap upto 5 Ton complete with all accessories all as specified and directed by Engr-in-charge.

2

-

-

... More
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.3 mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using galvanised iron strip 32x6mm earthing lead as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remain surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge incl testing on completion.

15

-

-

... More
Excavation in trenches not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide in any type of soil for laying and taking out of GI/CI pipes all as specified and directed by Engr-in-Charge

180

-

-

... More
Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm thick complete all as directed.

162

-

-

... More
Removing excavated soils to a distance not exceeding 50 m and depositing where directed complete all as specified and directed.

18

-

-

... More
Taking down/Cutting MS ERW pipe as Per IS 1239 line of size 150 mm bore, including all fittings of any type complete all as specified and directed.

200

-

-

... More
M&L in replacement of M/S ERW pipe as Per IS 1239 line of size 150 mm bore with Plain ends, heavy grade in any length laid in trenches by means of welding (For firefighting installation) in required position as taken down under Srl item 59 here-in-before complete all as specified and directed by Engr-in-charge.

150

-

-

... More
Relaying the MS ERW pipe as Per IS 1239 line of size 150 mm bore after cleaning as taken down under Srl item No 59 here-in-before including all fittings complete all as specified and directed.

50

-

-

... More
Taking up and down old/unserviceable MS ERW as Per IS 1239 tubing with fittings of size 100 mm bore including welding and cutting all as specified and directed by Engr-in-Charge. (earth work will be measured and paid separately).

200

-

-

... More
Relaying the MS pipe as Per IS 1239 line of size 100 mm bore after cleaning as taken down under Srl item No 62 here-in-before including necessary welding and all fittings complete all as specified and directed.

50

-

-

... More
M&L in replacement of M/S ERW pipe as Per IS 1239 line of size 100 mm bore with Plain ends, heavy grade in any length laid in trenches by means of welding (For firefighting installation) in required position as taken down under Srl item 62 here-in-before complete all as specified and directed by Engr-in-charge.

150

-

-

... More
Supply & fixing CI/DI/MS fittings up to 150 mm bore such as ( any type, bend/color/reducer and angle) tapers any type ( Straight, bends increasing, decreasing or double socket etc. ) tail pieces single branch Y junction, double branch cross ( all sockets or socket ends spigot) all as required at work site and as directed.

110

-

-

... More
S&F of CI sluice valve flanged of size 150 mm bore class PN-1.0 ISI marked with stainless steel spindle and iron wheel head complete with rubber gaskets, nuts, bolts washers and packing materials etc. all as directed and as per site requirement.

1

-

-

... More
All as per serial item No. 66 here-in-before but of size 100 MM

1

-

-

... More
All as per serial item No. 66 here-in-before but of size 80 MM

1

-

-

... More
Supply and fixing of CI non return valve of size 150 mm bore flanged ISI marked including bolts, nuts, washers and rubber gasket etc. complete all as directed.

1

-

-

... More
Supply and fix Cast Iron Foot valve including necessary fittings conforming to ISI mark conformed of size 100 mm bore all as specified and directed by Engineer-in-Charge.

1

-

-

... More
All as per serial item No. 70 here-in-before but of size 150 mm bore

1

-

-

... More
Supply and fixing Gun metal gate valve ISI marked with iron wheel head screwed both ends for pipe of size 50 mm .

1

-

-

... More
All as per serial item No. 72 here-in-before but of size 25 mm

2

-

-

... More
M & L for attending break down of pipe ling bursting /cracks including excavation in hard/dense soil with the use of earthmoving machinery/labour and taking out old CI/GI/MS defective/misaligned water pipe ling of size 200/150/100/50 mm dia bore carefully after disconnection of Joints to a length up to 6 mtr and create bund with excavate earths and excavated earth and dewatering/bailing out water complete with diesel engine driven pump set and positioning the pipe line after repairs/porocline all as directed by Engineer-in-Charge. Note:- (a) M/L for lead joints/spares/CI/GI specials will be measured and paid separately. (b) M/L for CI/GI/MS pipe, special lead joints etc. will be measured and paid separately under relevant schedule items. (c) The rate is deemed to include cost for tool and plant and transportation required for attending the repair work. (d) Disconnecting /dismantling/cutting the existing pipe line is included in quoted rate.. (e) The rate is inclusive of earth work complete including returning and refilling in any type of strata complete. (f) The break down shall be attended within 4 hrs of intimation round the clock and time of restoration shall be maximum of 5 hrs. The additional manpower required to complete the work is quoted rate is deemed to be included in the quoted.

1

-

-

... More
Cutting existing CI/MS water main 150 mm bore pipe and fire fighting pipe line in position for making branch connection and CI pipeline (Insertion of CI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Cast iron fittings such as tees, bends, collars reducers etc. joints and jointing material for fixing cast iron fittings, sluice valve shall be measured and paid separately.

3

-

-

... More
All as per serial item No. 75 here-in-before but of size 100 mm

3

-

-

... More
M&L joints with rubber gaskets for CI flanged pipe including necessary nut bolts and washers etc. for pipe 150 mm bore all as specified.

3

-

-

... More
S&F replacement brass spindle with checknut suitable for sluice valve of size 80 mm bore including replacement of gland packing all as directed.

3

-

-

... More
All as per description of srl item 78 here-in-before but of size 100 mm bore.

2

-

-

... More
All as per description of srl item 78 here-in-before but of size 150 mm bore.

2

-

-

... More
S&F in replacement unserviceable fire hydrant valve brass 65mm dia ISI mark (One end flanged and drilled holes) fitted with packing materials nut, bolts with washers complete all as specified and directed

10

-

-

... More
Supply and laying in repairs synthetic Insulating Mat of size 2m X 1m and 2mm thick for up to 3.3 KV Volts made from synthetic insulating material, free from any insertions leading to detoriation of insulating properties. Note : The upper surface should have small aberration (Rough Surface) with out edges to avoid slippery effects. The mat should be fire retardant & self extinguishing complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply and fixing battery heavy duty 12 volt 180 Ah heavy duty with battery leads complete all as specified and directed.

2

-

-

... More
Supply only search light rechargeable heavy duty complete all as specified and directed.

2

-

-

... More
Supply and fixing pvc insulated copper conductor multi stranded cable of size 25 sqmm single core complete all as specified and directed.

50

-

-

... More
M&L in replacement of smoke detectors (Optical type) complete including taking down the same all as specified and directed by Engr-in-charge

10

-

-

... More
S&F in non percolated fire chief brand cotton synthetic fibre circular woven jacketed, rubberized fabric reinforced rubber lined (RRL) fire hose, delivery treated against rot with mystox, having 38 Kg/cm2 brust pressure, 22kg/cm2 proof pressure, 14kg/cm2 working pressure bearing IS 636-1988 type A mark & having TAC & MMD approval 63 mm inside dia in 15 mtr length with ISI marked male and female instantaneous coupling with copper binding complete all as specified and directed by Engr-in-charge

25

-

-

... More
Painting fire hydrants hose boxes as per existing sizes complete including cleaning, scraping of old rusted surface paint inside and outside of panel surface with two coats of synthetic enamel paint and writing of SRL No as per existing size complete all as specified and directed

25

-

-

... More
S&F in replacement of broken glass of fire hydrant panel with glass size 80cm x 14cm x 5 mm thick end covered type including rubber beading for finish of glass or as per existing glass on site and directed by Engr-in-charge.

24

-

-

... More
Taking out fire fighting motor from the existing foundation, transport to workshop for rewinding by using super enamelled copper winding wire of existing wire gauge including other allied items such as varnish tape, sleeve, greasing etc. of suitable size for following capacity of motor and refixing after testing and commissioning complete all as specified and directed :-

-

-

-

... More
90 to 105 HP

1

-

-

... More
20 to 30 HP

1

-

-

... More
S&F hose box made out of 2 mm thick sheet size as per site with a provision two fix MS flanged pipe for hanging of hose pipe , MS line to accommodate hose pipe ,with front double window with glasses as per existing on site each with rubber beading with locking arrangements, painted red colour and numbered with white paint and opening the valves should be outside and inside the box only hose pipe safety all as specified and directed by Engr-in-Charge. Note: Hose box should be fitted in PCC / Brick foundation as per required on site.

5

-

-

... More
Dismantling to the existing AMF panel and depositing to the MES store yard and supply install ,testing commissioning AMF panel for control of Jockey pump(20-30 HP) with Centrifugal pump(90-105 HP) to maintain the auto pressure of 50 PSI to 110 PSI including all connected accessories like power contactor, tripping and starting coil lugs, relay , Aluminium cable up to 95x 3.5 core up to 50 mtrs etc. complete all as specified and directed by Engr in charge

1

-

-

... More
M & L for removing existing Centrifugal/Jockey pump set from base frame after disconnecting suction & delivery lines replacing bearings, repairing and grinding the shaft etc. complete and reassembling and fixing back to original position and testing, commissioning etc. complete all as directed for the following:- (Notes :- Any minor part up to Rs 2000 if required will be provided by contractor without any extra cost.)

-

-

-

... More
90-105 HP Pump Set

1

-

-

... More
20-30 HP Pump Set

1

-

-

... More
M & L for removing existing Fan blade from pump set motor and replacing and reassembling and fixing back to original position and testing, commissioning etc. all as directed complete for the following capacity :-

-

-

-

... More
90-105 HP Pump Set

1

-

-

... More
20-30 HP Pump Set

1

-

-

... More
M&L for laith work as per required size for Pump shaft of 90-105HP capacity pumping set, including sleeves, machining, threading, making key slot etc. complete all as directed.

1

-

-

... More
M&L in replacement of coupling set with all accessories for Pump shaft of the following capacity pumping set ,including machining ,threading, making key slot etc.as directed.

-

-

-

... More
90-105 HP Pump Set

1

-

-

... More
20-30 HP Pump Set

1

-

-

... More
M&L in replacement of CI impeller for 105 HP capacity pumping set all as directed.

1

-

-

... More
M&L in replacement of gland coupling brass bush for the following pumping set all as directed:-

-

-

-

... More
90-105 HP Pump Set

2

-

-

... More
20-30 HP Pump Set

2

-

-

... More
M&L in replacement of gland cup including changing gland rope for the pumping set of capacity 105 HP/75 KW all as directed.

2

-

-

... More
Servicing and maintaining pumping installation by tightening the gland of pump ,replacing rubber coupling ,bushes and clearing the leakage of sluice valves, NRV's, aircock, pressure gauge by tightening gland etc. comprising 2 Nos pump sets of capacity 90-105 HP and 20-30 HP complete all as specified and as directed.

4

-

-

... More
M&L for cleaning of SWT up to 1,00,000 gallons capacity including removal of all deposited scales, dirt and settled sand particles from intake of circulating pipe, cleaning with brushing, sweeping and brooming of inner and outer wall of the tank and washing the complete with bleaching powder solution and also re-writing date of cleaning and marking all as directed by Engr-in-Charge.

2

-

-

... More
S & F in replacement of Electric fire alarm panel board and testing the cable from firefighting location to missile sheds and other shed where it is connected if any leakage of cable found rectify it and after repair the leakage testing it with a smoke or any electric short-circuit at this time fire alarm system has to calling. If any leakage in sheds found rectify it and check. The repair of panel board and testing should be done in front of MES operator and describe to the operator what kind of fault can be raised and how to rectify that completely all as specified and directed by Engr-in-charge.

1

-

-

... More
Maintenance and servicing of DG set consisting of replacement of fuel filter, air filter and lub oil filter including replacement of engine oil all as directed and testing on full connected load for the following capacity of DG Sets and any make as per OEM. Note: Engine oil will be measured and paid separately.

-

-

-

... More
DG Set 10 KVA to 20 KVA

4

-

-

... More
DG Set 25 KVA to 50 KVA

4

-

-

... More
DG Set 200 KVA to 320 KVA

4

-

-

... More
M & L for replacement of existing unserviceable Fan Belt and testing complete for the following capacity of DG Sets and any make as per OEM.

-

-

-

... More
DG Set 10 KVA to 20 KVA

1

-

-

... More
DG Set 25 KVA to 50 KVA

2

-

-

... More
DG Set 200 KVA to 320 KVA

2

-

-

... More
M & L for replacement of existing unserviceable Hose Pipes with clamps and testing complete for the following capacity of DG Sets and any make: :-

-

-

-

... More
DG Set 10 KVA to 20 KVA

1

-

-

... More
DG Set 25 KVA to 50 KVA

2

-

-

... More
DG Set 200 KVA to 320 KVA

2

-

-

... More
Taking out the old unserviceable radiator from the DG set and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc. complete all as directed for the following capacity of DG Sets and any make as per OEM.

-

-

-

... More
DG Set 10 KVA to 20 KVA

1

-

-

... More
DG Set 25 KVA to 50 KVA

2

-

-

... More
DG Set 200 KVA to 320 KVA

2

-

-

... More
M&L for repair and overhauling of unsv self starter 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.

2

-

-

... More
M&L for repair and overhauling of unsv dynamo/alternator 12 V of any capacity DG set including repair/replacement unsv/defective spares such as field coil, armature winding, carbon bushes, clutch bushes and pinion assy complete all as specified and directed.

2

-

-

... More
S&F in replacement of unsv battery charger of capacity 24 V all as specified and directed by Engr-in-Charge.

2

-

-

... More
S&F in repair AVR with functions to adjust generator output voltage, prevent voltage hunting, set under frequency roll off knee point, set generator droop to 5% at full load, match AVR input to accessory output, set the over excitation cut off level, set initial frequency related voltage dip, over-voltage protection cut off level, maximum short circuit current with sensing input voltage range 170 - 250 V AC max, 50 -60 HZ frequency with output max upto 120 V DC, continuous current 2.7A & transient 6A for 10 sec including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG sets of capacity 10.5 to 20 KVA.

1

-

-

... More
All as per srl item No. 110 above but for DG set capacity 25 to 50 KVA

1

-

-

... More
All as per srl item No.110 above but for DG set capacity 200 to 320 KVA

1

-

-

... More
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 180 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed

4

-

-

... More
Taking out the old unserviceable battery from the DG Set and supply and fix new 12 V, 100 AH maintenance free battery make Amron/Exide including testing and commissioning complete all as specified and directed

2

-

-

... More
M & L for repair of Water pump of 10.5 to 20 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed

1

-

-

... More
M & L for repair of Water pump of 25 to 50 KVA DG set including replacement of defective unsv spare part of any make and model and refix the same after repair complete all as specified and as directed

1

-

-

... More
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 10.5 to 20 KVA KVA DG Set of any make and model complete all as directed.

1

-

-

... More
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 25 to 50 KVA DG Set of any make and model complete all as directed.

2

-

-

... More
M&L for Calibration of Fuel pump including replacement of unsv/defective spares of 200 to 320 KVA DG Set of any make and model complete all as directed.

2

-

-

... More
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv/defective spares of 10.5 to 20 KVA DG Set of any make and model complete all as directed.

1

-

-

... More
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv/defective spares of 25 to 50 KVA DG Set of any make and model complete all as directed.

2

-

-

... More
M&L for overhauling and calibration of fuel injector assembly including replacement of unsv/defective spares of 200 to 320 KVA DG Set of any make and model complete all as directed.

2

-

-

... More
Supply and fix in replacement battery leads set, PVC insulated multistranded, copper conductor of min size 35 sqmm 1 mtr long each duly fixed with brass clamps, copper lugs suitable for DG sets of different capacities.

4

-

-

... More
M/L for replacement of coolant for radiator for DG set at various locations all as specified.

60

-

-

... More
M/L for replacement of Lub Oil (Engine Oil) of grade 20W40 for Engine for DG set at various locations all as specified.

400

-

-

... More
M/L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc. including replacement of PVC pipe fuel level indicator, writing of tank capacity, date of cleaning and next due date for tank to be cleaned for following capacities of DG Set and any make as per OEM.

-

-

-

... More
DG Set 10 KVA to 20 KVA

1

-

-

... More
DG Set 25 KVA to 50 KVA

2

-

-

... More
DG Set 200 KVA to 320 KVA

2

-

-

... More
M & L for scrapping of old paint from DG set and preparation of old painted surfaces for re-painting. Repainting complete body of DG set with superior quality super enamelled paint of colour as per standard engineering practice for engine, alternator, base frame etc. by spraying including writing SM/MES No, all as specified and directed.

-

-

-

... More
DG Set 10 KVA to 20 KVA

1

-

-

... More
DG Set 25 KVA to 50 KVA

2

-

-

... More
DG Set 200 KVA to 320 KVA

2

-

-

... More
M&L for replacement of acrylic sheet diagram of main incoming and outgoing elect supply/water supply to various destination and generator supply destination all as directed and specified size of display not less than 1.0x2.0 mtr with all decoration as specified.

2

-

-

... More
M&L for replacement of acrylic sheet DO and DON'T instructions in Hindi/Punjabi and English language for elect supply installations and water supply installations all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.

4

-

-

... More
M&L for replacement of acrylic sheet instructions for pump operation in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.

2

-

-

... More
M&L for fire point comprising of the following. (a) CO2 fire extinguisher 4.5 Kg (02 Nos), b) Dry carbon powder (ABC)-05 Kg (02 Nos) ,ceiling Hook, fire beater, sand buckets 9 mtrs capacity-02 Nos ,Showel complete with angle iron stand duly painted with two coats of synthetic enamel paint of approval colour over a coat of red oxide primer incl dismantling old unsv one.

2

-

-

... More
M&L for replacement of electric shock and its management with picture in Hindi/Punjabi all as specified size of display not less than 2.0x1.0 ft with all decoration as specified.

2

-

-

... More
M&L for replacement of Maintenance schedule of Sub stations instructions board on acrylic sheet in Hindi/Punjabi all as specified size of display not less than 3.0x1.5 ft with all decoration as specified.

2

-

-

... More
Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. (ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.