If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 92,920Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Spl Repair To Bldg No. T-20 (or Living) Of 11 Corps Pro Unit And Certain Other Sanctioned Work Under Ge (east) Jalandhar Cantt
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673821_1Tender No
GE/JULL/ET-68/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L 15 mm thick cement plaster in cement mortar 1:6 on internal surface of brick or concrete surface finished even and smooth without using extra cement all as specified
540
-
-
M&L for preparing new surfaces plastered or unplastered surfaces of walls by applying two coats of oil bound distemper over a coat of primer over a coat of 1 mm avg thickness wall putty complete all as specified.
540
-
-
Complete removal of existing treatment and preparation of old plastered surfaces of walls and applying two coat of oil bound distemper over a coat of primer over 1mm avg thickness wall putty complete all as specified.
211.71
-
-
M&L for 15 mm thick cement plaster in cement mortar 1:4 with water proofing compound as per manufacturer's instructions to brick or concrete surface finished even and smooth without using extra cement and using waterproofing compound all as specified (WPC shall be measured and paid separately)
95
-
-
Supply only integral water proofing compound
25
-
-
Material & Labour for new plastered surface of walls surface applied two coats of acrylic exterior emulsion paint (weathercoat) over a coat of wall primer complete all as manufacturrer's instructions complete all as speicfied and as directed.
95
-
-
M&L for complete removal of existing treatments by washing, rubbing down and stopping etc on wall surfaces and applied apply two coats of acrylic exterior emulsion paint (weathercoat) uses as per manufacturer direction over one priming coat complete all as specified and as directed by Engr-in-charge.
24.13
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified
535
-
-
M&L for non skid ceramic coloured tiles area of each tile exc 0.11 sqm but n. exc 0.18 Sqm, 7 to 8 mm thick in floor/skirting set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & including screed bed or bedding layer of morter 15mm thick in CM (1:6) for laying floor finishes , complete all as specified and as directed.
Make:-Kajaria/ Somani/ Johnson
210
-
-
All as per item No 12 above but on skirting etc over and including 10 mm thick cement plaster finished even and rough to receive tiles in Cement mortar (1:4) complete all as specified.
15
-
-
M&L for 25mm thick PCC (1:2:4) type B0 using 12.5mm graded aggregate as in sub floor , sub base; concrete surface finished even & rough to receive topping floor/tiles finish/layer complete all as specified.
210
-
-
M& L for glazed ceramic tiles in vertical surface 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and rendering 10mm thick in CM 1:4 as in backing coat of wall tiles complete all as specified and as directed.
10
-
-
Material and labour for machine cut Kota stone slab size 550 x 550 x 20-25mm thick flooring over 15mm cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab inlcuding rubbing and polishing complete all as specified and as directed
300
-
-
M&L for for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 15mm thick cement screed bed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
5
-
-
Dismentling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and as directed.
1113.9
-
-
S&F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of anY colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
606.9
-
-
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Make:- TATA/ JSW/ Indian Ispat.
24.6
-
-
Dismantling work for Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
210
-
-
Supply and fixing mineral fibre acoustical suspended ceiling system with dune (Tegular) edge tiles with 24mm exposed grid. The tiles should have humidity resistance of 99%, NRC 0.5, light reflectance 85%, thermal conductivity K=0.052-0.057 w/m K, colour white, fire performance UK class 0/ class I (BS 476 pt-6 & 7) in module size of 600x600x16mm, suitable for green building application with recycled content of 32%. The tile shall be laid on prelude 32 with 24mm wide T section flanges colour white rotary stitching on all T sections i.e. the main runner, 1200mm & 600mm cross Tees with a web height of 27mm and a load carrying of 7.1 Kgs/sqm and minimum pull strength of 100 Kgs. The T section have galvanising of 90 grams per Sqm and need to be installed with suspension system. All accessories manufactured and supplied by armstrong world industries complete all as specified and as directed
210
-
-
Taking down chowkats or frame not exc. 1.5 sq m each with shutters (without taking off shutters from the fames)
30
-
-
Taking down chowkats or frame exc. 1.5 sq m but n.exc 4 sq m each with shutters (without taking off shutters from the fames)
9
-
-
M&L for MS work as in hold fast and similar small articles complete all as specified.
200
-
-
S & F for Pressed steel frames size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. hollow section of steel frame filled with PCC (1:4:8), complete, as specified.
40
-
-
S&F 2nd class hard wood 35mm thickness of factory made plain framed, panelled shutter with lock rail and panel of 9 mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part-I), kiln seasoned and chemically pressure treated.
23.31
-
-
S&F for 2nd class hard wood 35 mm thick glazed and skeleton shutters, factory made, open rebated and prepared to receive glass, gauge etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR part-I, sector 8, clause 8.20 (a)
23.31
-
-
M&L for preparation of new wood or wood based surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of pink primer complete all as specified and as directed by Engr -in-charge.
93.24
-
-
S&F butt hinges medium weight, cold rolled mild steel 100 mm size
54
-
-
S&F 300 mm long mild steel sliding door bolts stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified.
18
-
-
S&F Mild steel pressed handles oval type stove enamelled black 150 mm size
36
-
-
S&F Mild steel barrel tower bolts, 200mm long, stove enamelled black, with bright bolt.
36
-
-
S&F Aluminum floor door stopper 63 mm with two rubber legged all as specified and as directed
18
-
-
Supplying and fixing steel windows 1.25 mm thick Box type (primer coated) ERW hollow 'P' section of size 60 mm x 25 mm single rebated comprises of glazed sutter EWR sec 50 mm x 20 mm and 1 mm thick and two openable leaf conisting two Nos sash bar of 'T' section 20 mm x 3 mm complete welded to frame with one vertical mullion of EWR bot 'T' section of size 60 mm x 25 mm and 1.25 mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1, four Nos for each window including following fittings welded to failed shutter:-
(a) Holdfasts 150 mm long 12mm x 3 mm made to shape- 4 Nos per window
(b) Handle of Z sec 20 mm x 25 mm, 100 mm long - 1 nos per leaf.
(c) MS tower bolt 150 mm long - 2 Nos per leaf.
(d) 'Z' sec 20 mm x 25 mm , 100 long stopper-01 Nos per leaf,
(e) Cleat 55mm long of hollow square 15 mm x 20 mm x 63 mm welded to hinges - 1 Nos per leaf
(f) MS pintal hinges of size 75 mm x 12 mm - 2 Nos per leaf.
(g) fabriction and fixing arrangement complete.
Note:- Grill / guard bar , glass pane shall be measured and Paid saperately.
25
-
-
All as per description of serial item No. 35 above but in gauged shutters without sash bars all as specified and as directed
25
-
-
All as per description of serial item No. 35 above but in ventilators fixed type .
4
-
-
S & F framed work such as grills, gratings, cooler stand etc .with ends of bars shouldered and/ or riveted , or forget into spikes ; framed guard bars barallel iron doors and similar work conforming to Fe.290.Gde-E-165
300
-
-
S&F galvanized mild steel wire cloth 0.56 mm nominal dia and average width of aperture 1.18 mm and fixed with tinned tacks.
25
-
-
M&L for 4.00 mm thick glass sheet, ordinary quality and glazing with oil putty in square n. exc 0.5 sq. m in each pane.
25
-
-
Dismantling of brick work or stone/boulders masonary, built in cement mortar or cement lime mortar including all quions, arches, pillars etc. and rubbish materials remove from site all as specified and as directed
10
-
-
Brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
7
-
-
All as per Item No 42 above but except bricks complete all as specified and as directed.
3
-
-
S&F in repair for stainless steel pipe 25 mm dia fancy type curtain road fixed in the MS hooks, and finials/side brackets (both side), shade as approved by GE all as specified.
100
-
-
Dismantling cast iron work of any description complete all as directed.
5.7
-
-
Supply & fix rolled mild steel work for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe 410-W Gde E-250 complete all as specified and as directed.
570
-
-
M&L for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applied two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed by Engr-in-charge.
110
-
-
Demolition of cement concrete in ground floors and paving n. exc 15 cm thickness (below or above the ground level) complete all as specified and as directed.
5.63
-
-
Material and labour for cement concrete type D-2, 1:4:8 (40mm graded aggregate) 75mm thick as in sub base of flooring complete all as specified and as directed.
25
-
-
Material and labour for 75mm PCC 1:3:6 type C1 using 20mm graded aggregate as in plinth protection and path finishing the surfaces even and smooth with using extra cement complete all as specified and as directed.
25
-
-
Material and labour for chequered cement concrete tiles 30cm x 30cm x 18 to 20 mm thick set with grey cement and pigments jointed and pointed in neat coloured cement slurry in floors over and including 15 mm thick cement screed bed in cement mortar (1:6) including demolition of old tiles/concrete floor all as specified and as directed
25
-
-
Material and labour for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sides of rounded or chamfered on edges of interlocking/ chequered tiles, bed block concrete complete all as specified and as directed
1
-
-
M&L polycarbonated plain sheeting 10mm thickness with side lap fixed with coach screw and washer self tapping screw in roof, wall etc as specified and as directed.
507
-
-
M&L for cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and as directed.
10
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
1.7
-
-
M&L for structural steel , rolled section such as joist, beam, channel, angle, tee,in available lengths Fe-410-W(Gde- E 250) quality B all as specified and as directed.
170
-
-
Material and labour for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
40
-
-
Taking down carefully existing point wiring of any type/ any size (ie on wooden/ batten, surface conduit, casing capping or concealed conduit) complete for light, fan, socket or power point etc including removing switches, sockets, holders, ceiling rose, pendants, regulators, light fittings, switch board outlets with sheets and other materials from site for refixing of serviceable light, accessories for taking credit of unserviceable light and accessories as per Sch of credit and making good disturbed surface of walls,roof, floors etc. with any type of civil wk involved complete all as specified and as directed.
168
-
-
M&L for point wiring for light/fan point with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm cable drawn in and including concealed rigid PVC conduit medium grade not less than 20mm dia with accessories including cutting chases for laying of conduit /fixing of boxes in walls/floor etc including making good to disturbed surfaces as per adjoining specification and terminated in and incl sunken pressed steel boxes duly painted with anti corrosive paint over a coat of red oxide primer with plastic laminated bakelite sheet top cover 3mm thick make hylum or equivalent fixed with nickel polished screws with cup washers etc including FRLS PVC insulated unsheathed multi stranded copper conductor 1.5 Sqmm single core as earth continuity conductor (green colour) connected with earth dolly with thimble complete all as specified and as directed by Engr-in-Charge.
102
-
-
All as per srl item No. 60 above but for one fan point controlled by one switch complete all as specified
29
-
-
All as per srl item No. 60 above but for one socket outlet 5 Amps on independent board complete all as specified.
44
-
-
All as per srl item No.60 above but for one socket outlet 5 Amps on the same board controlled complete all as specified.
31
-
-
All as per srl item No. 60 above but with 2.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable for one 3 Pin 15 Amp socket on independent board including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and as directed by Engineer-in-Charge.
14
-
-
S&F switch piano flush type, 6 Amps single pole, one way complete all as specified.
206
-
-
S&F switch piano flush type 16 Amps single pole, one way complete all as specified.
14
-
-
S&F socket out let 6 Amp, 5 pin, 2-in-1 flush type complete all as specified.
75
-
-
S&F Socket outlet multi purpose 2 in 1, 5/6 pin, 5 & 16 Amps, flush type complete all as specified.
14
-
-
S&F five step fan regulator, electronic type, single phase, including connection complete all as specified.
26
-
-
S&F ceiling rose surface type PVC/ polycarbonate 65mm x 50mm three terminal complete all as specified.
71
-
-
S & F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with matching colour back plate all as specified and as directed.
15
-
-
Supply and fixing LED lights fitting 1x 20 Watt, 220V AC decorative box type frame with holder including LED tube rod 20 watt connecting up single/ double connections with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Make:- Philips/ Crompton/ Bajaj.
42
-
-
S & F energy saving & environmental friendly long life versatile pressure die-cast aluminium housing luminaire with heat resistant glass and suitable optics for uniform distribution of light 35 watt LED bldg security lights with high efficiency electronic driver BIS approved, having IP-66 protection, surge protection operative on AC supply 140 volts to 270 volts pre-wired complete with GI pipe of 25mm bore of suitable length and MS clamp duly painted with two coat Aloxide paint all as specified and as directed.
Make:- Philips/ Crompton/ Bajaj.
10
-
-
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, clamps suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed
Make:- Philips/ Crompton/ Bajaj.
19
-
-
Fixing only serviceable tube light fittings any type and any description retrieved under item Srl No. 66, including necessary electric connection with round flexible wire with multi stranded copper conductor of size 0.50 sqmm, 3 core, 1100 volts grade complete all as directed.
16
-
-
Supply & fixing LED retrofit lamp 9W , 6500K, 220-240V with base cap B-22. complete all as specified and as directed.
15
-
-
Supply & fix wall mounting fan 230 volts single phase 400 mm sweep, 3 speed, suitable for wall mounting type complete all specified and as directed.
3
-
-
Supply & Fix MCB SP 6 to 32 Amps 240 V, 10 KA, B curve complete all as specified and as directed by Engr-in-charge. Make:- ABB/ Schneider/ Legrand/ Hager.
42
-
-
Supply & Fix MCB SPN 40 Amps 240 V, 10 KA, B curve complete all as specified and as directed by Engr-in-charge. Make:- ABB/ Schneider/ Legrand/ Hager.
5
-
-
M&L in replacement for sheet metal DB for MCBs, SPN, 8 ways 240 v, double door, single phase, with copper bus bar, neutral bar/ connectors/ earth link suitable copper thimbles, lugs etc complete all as specified. Make:- ABB/ Schneider/ Legrand/ Hager.
5
-
-
Supply and Fix in repair TPN double door DB 4 way with Bus Bars, Neutral Links, blanking plates suitable for fixing of TPN upto 63A as incommer and MCB for outgoing fixing in wall all as specified and as directed. Make:SIEMENS/Legrand/SCHNEIDER/ ABB
1
-
-
Supply & fixing in repair TPN MCB 63 Amps, 10 KA, B curve complete all as specified and as directed by Engr-in-charge. Make:- ABB/ Schneider/ Legrand/ Hager.
1
-
-
Taking down carefully and refixing ceiling fan of any sweep or make, painting of fans complete (as per previous colour) with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc including replacement of flexible wire, rubber reel, nut, bolts all as specified and as directed.
18
-
-
Supply & fixing down rod of Gi pipe medium grade 15 mm dia bore with slot & provision of 2 Nos hole of suitable size on top & bottom of size upto 2 mtr length complete painted with two coat of synthetic enamelled paint complete all as specified and as directed by Engr-in-charge.
8
-
-
M& L for ceiling fan fixing clamp/bracket to be fixed with purlin/steel structure/wooden joist made of MS flat iron 40 x6mm minimum of suitable length and bent to shape matching with structure to which it should be fixed including suitable fixing arrangement of down rod 15mm dia with clamp bolt, nuts and incl preparation of surface with iron oxide and two coat of synthetic enamelled paint complete all as specified and as directed.
8
-
-
M& L for XLPE insulated, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 3½ core complete laid in trenches passing through pipes/culverts/ under roades/ along wall all as specified and as directed by Engineer-in-charge.
60
-
-
Excavation in trenches in soft/Loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and as directed by Engineer-in -Charge.
7
-
-
Returning and filling in, including spreading and levelling, water and well remming in layers not exc. 25cm all as specified and as directed.
3
-
-
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and as directed.
4
-
-
Supply and laying old size sub class 'B' bricks laid flat in trenchs over the cable with the length of brick perpendicular to the direction of cable length, compressive strength of brick shall not be less than 75 kg/cm² adjacent/abutting each other complete all as specified and as directed by Engineer-in-Charge.
0.28
-
-
Material and labour Sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches and punned down complete all as specified and as directed.
Note:- Punned down thickness of 18cm shall be masured and paid.
2.83
-
-
M&L for GI tube light grade 40mm bore with fittings laid in trenches or fixed on wall/floor for protection of UG cable complete all as specified and as directed.
7
-
-
M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4 Sqmm drawn through in and incl PVC rigid non metallic concealed conduit (medium grade ISI marked) with all fittings including earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm PVC insulated with green insulation complete all as specified. NOTE: Two run of 4 sqmm wire and one run of 4 sqmm wire as earth wire including PVC conduit shall be measured as one unit.
180
-
-
Earthing complete in replacement with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below normal ground level with the top edge of electrode not less than 1.5 meters below normal ground level connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and incl GI lead protection pipe of GI light grade 15mm dia upto 7.5 mtrs and watering pipe 20mm bore of GI medium grade with funnel and wiremesh, earth plate covered on all sides with min 150mm thick alternate layers of charcoal, salt all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing point with PCC chamber and RCC cover in 1:2:4 complete with any type of earth work involved all as specified and as directed and testing on completion. Note:- PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
8
-
-
Supply, erection, testing and comissioning of 12.5 mtr high mast light system for 6 luminaires(raising & lowering type with motor incl manual provision also) having following specifications & accessories.
a) High Mast: The high mast light system of 12.5 Mtr high mast,(made up of 2 sections) entirely high mast structure (internally and externally) and all MS part shall be hot dip galvanized. The high mast shall be of continuously tapered polygonal cross section made up of two sections having sheet thickness 3 mm min. for lower section and upper section. The mast shaft shall be manufactured from high tensile steel plate conforming to S355 grade as per BS-EN 10025 having longitudinal welded seam only and without any circumferential weld joint approx. The minimum dimension across flats of top shall be 100mm approx and bottom(base) 360 mm approx or as recommended by OEM. The base plate shall have thickness 25mm and diameter 520mm min. It shall have door at suitable height of size 1200x250mm min or as recommended by OEM having vandal resistance, weather proof type with pad locking facility. The base flange shall be provided with supplementary gussets between the bolt holes. The door opening shall be carefully designed and reinforced with welded steel section, so that the mast section at the base shall be unaffected and undue buckling of the cut portion is prevented.
3
-
-
(b) Luminaires Carriage: Hot dip galvanized luminaire carriage of suitable diameter designed to install symmetrically 6 Nos luminaries fabricated from ERW tubes in two halves having bolted flanged joints at side with stainless steel bolts and nuts to permit removal from an erected mast. Holes are to be provided in the bottom side of the tubes to act as conduit for wiring cables. Luminaires fixing arms and plates are to be welded to the carriage. Carriage shall have fitted with buffer arrangements to prevent damage to the mast finish during movement. Suitable junction box (as applicable) shall be cast aluminium weather proof provided on the carriage assembly for terminating the trailing cable and power cable to luminaries.
-
-
-
(c) Winch/ Power tool: The double drum winch shall be completely self sustaining without the need for brake shoe, springs or clutches and self lubricating type by means of an oil bath. The worm gear ratio shall be of suitable ratio and having safe working load 750 Kg min. The drums are to be grooved to provide the perfect seat for the stable and tidy rope lay arrangement for distortion free rope and termination. The winch shall have provision to operate electrically through power tool or manually in case of power failure. Single phase/Three phase single speed, high power motor of suitable rating min or as recommended by OEM suitable to lift the load mounted on plate to adjust the length of motor of chain shall be provided in base compartment. Mechanical torque limiter mounted on motor shaft for start/stop transmission of motion shall be provided. The power tool shall be supplied with reqd wiring & accessories suitable to match with High mast control panel.( Suitable Handle to be provided to manual taking down of luminaire carriage.)
-
-
-
(d) Hot dip galvanized head frame as a capping unit of the mast of the welded steel construction and provided with guides and separators between the rope and cable complete with aluminium pulleys with bush bearing mounted through stainless steel shaft suitable to accommodate wire rope and multi core trailing cables. The head frame to be provided with guides and stops with PVC buffer for the locking of the luminaire carriage. The pulley shall be covered with a hot dip galvainzed canopy. The suspension wires shall be made of stainless steel wires rope of AISI 316 grade, 7/19 construction with central core in the same material of 6mm dia. The breaking load capacity of wire rope should be 2350 Kg x 2 minimum. The end termination luminaire carriage shall be with stainless steel thimble etc.
(e) The multi core flexible power trailing cable from base compartment to junction box at luminaries carriage shall be ERP insulated /PCP sheathed 1100 volts grade copper conductor with male female connectors of suitable rating and size having suitable cores for 6 Nos luminaires or above as required at site for control of these ligths as directed by Engr-in-Charge. The system shall have in-built facilities for testing the luminaries while carriage in lowered position.
-
-
-
(f) One number heavy duty hot dip galvanized lightning finial shall be provided for the mast. The lightning finial shall be minimum 1.2 M in length or as required so that the lantern carriage also comes within the safety zone and shall be provided at the centre of the head frame. It shall be bolted solidly to the head frame to get a direct conducting path to the earth through the mast. The lightning finial shall not be provided on the lantern carriage under any circumstances in view of safety of the system. A suitable space shall be provided at base of the mast to connect with earthing. The mast shall have single/double dome LED aviation light at the top of suitable capacity.
(g) Mast shall be erected with foundation bolt set comprises of anchor plate with qty/number of bolts ( as recommended by OEM) .The foundation bolt shall be TS600, 24mm diameter, 750 mm long or as recommended by OEM.
(h) Construction of shallow foundation with suitable grade concrete, iron, steel bar or as recommended by OEM for the high mast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth with all materials and labour complete as per OEM drawing after approval of Engr-in-Charge. The rate also include the cost of PVC/GI pipe 3 inch dia required to be fixed in foundation concrete for the passage of cable.
-
-
-
Note: (i) The quoted rate include the cost any type of special T&P, tools, equipments reqd at site for erection, installation of the complete high mast light system. The quoted rate include the cost of any control/junction box for lights, foundation other accessories, items which is necessary for the satisfactory functioning of the high mast light system but not mentioned in here. (ii) The contractor shall provide genuineness/ authentication certificate from manufacturer to confirm that High mast is of make approved by dept as specified in CA. No payment shall be released till contractor provide the same.
Make of Mast: Bajaj/Crompton/Surya
-
-
-
S & F LED flood light fitting of 150 watt in epoxy/ powder coated pressure die-cast aluminium housing with, heat resistant toughened clear glass fixed with SS screws controlled with potted CVCC type, BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 4 KV minimum in circuit and 5 KV outside the driver but inside the fixture with IP-66, Class-1 protection for LED and control gear compartments with high power LED chips of rating 2.5 to 3 watt (maximum) with colour temperature 5700 K(max) with secondary optics modular lenses provided to minimize glare and for better distribution of light suitable for voltage band 120 volts to 270 volt, power factor 0.95 (minimum) having efficacy 100 lumens/watt on 12.5 mtr high mast pole all as specified and as directed.
18
-
-
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 32x6 mm as earthing strip by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth strip protected by 40mm dia GI light grade pipe (IS-1239), PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. (Note: The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner . (2) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.
6
-
-
Supply and fix MCCB enclosure size 400x600x300mm min , outdoor type, including MCCB 63 Amp 25 KA, 4P with terminal links/phase extender incl phase barrier on wall/panel complete all as specified and as directed.
(to be fixed on existing panel)
3
-
-
Supply, install, testing and commissioning of feeder pillar, of size 0.9 mtr x 0.7 mtr x 0.5 mtr (Min), outdoor cubicle type weather and vermin proof totally enclosed made out of 3 mm thick CRCA sheet machine pressed, suitable to operate on 3 phase 4 wire system, 415 volts, 50 Hz with locking arrangement,removable bottom gland plate with sufficient numbers of circular cable entry holes including glands, prewired complete duly powder coated (7 tank Min.) with supporting legs of angle iron of size 40 x 40 x 6mm of length 100 cm long duly grouted in PCC (1:3:6), 40cm below ground level and 60 cm above ground including construction of masonry /PCC plateform complete all as specified and as directed. The panel shall be comprising of following. (i) MCB TPN 40 A 'C' curve -02 Nos (ii) Contactor 32 Amp 3 Pole for auto on/off of light -01 No
(iii) MCB SP-32 Amp-01 No
(iv) Astronomical Digital timer - 01 No
(v) Toggle/selector switch for auto/ manual operation-01 No
(vi) Digital Multifunction meter -01 No to display Volt, Amp,KWH,frequency etc.
(vii) LED indicator R,Y,B-01 set
(viii) CT's set of 3, 100/5 Amp rating
3
-
-
(ix) Control system for motorized control of High mast to lower and raise the luminaire carriage through motor with suitable Nos push button,contactors as reqd at site.
Note:- The panel shall have sliding bolt also for locking arrangement.The 'FRONT' & 'REAR' side 'DANGER' sign notice plate shall be provided on doors.
-
-
-
M & L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI Pipe up to 50mm mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. (Note: The GI pipe shall be measured and paid separately.)
10
-
-
Supply and fixing galvanised pipe light grade (IS-1239) 50 mm bore for passing of cable fixed to poles/walls/lay under floor complete with and including fittings as required compete all as specified and as directed Engr-in-charge.
12
-
-
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 16 Sqmm, 4 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall complete all as specified and as directed
420
-
-
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and as directed by Engineer-in-Charge.
56.7
-
-
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and as directed by Engineer-in-Charge.
34.12
-
-
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-charge.
22.58
-
-
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and trenches punned down to thickness of 18 cm complete all as specified and as directed.(Note: Punned thickness of 18 cm will be measured and paid)
18
-
-
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and as directed by Engineer-in-charge.
2.24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%