If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Mar 2019
Closing Date28 Mar 2019
Tender Amount₹ 10,59,710 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Repair/ Replacement / maint of E/M items at Mil Stn Beas and Jandiala Guru under GE Kapurthala
Repair/ Replacement / maint of E/M items at Mil Stn Beas and Jandiala Guru under GE Kapurthala
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl item No 2 here-in-before but for one socket outlet 3 Pin, 6 Amp on independent board

-

-

-

... More
All as per Srl item No 2 here-in-before but for one socket outlet 3 Pin, 6 Amp on same board.

-

-

-

... More
All as per Srl item No 2 here-in-before but for one bell point controlled by one bell push

-

-

-

... More
All as per Srl item No 2 here-in-before but for one light point controlled by two 2 -way switches, with cables 1.5 Sqmm size.

-

-

-

... More
M&L for point wiring with PVC unsheathed single core multistranded copper conductor cable of size 2.5 Sqmm (nominal area) in and including PVC conduit 20 mm dia by cutting chases in walls by cutter and making good the surface in CM 1:3 and to the original specification and PVC cassing capping on ceiling for steel structure/surface conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel terminal boxes including providing new 3 mm thick plastic laminated sheet cover (Hylem) including one run of PVC insulated FRLS copper conductor cable of 1.5 Sqmm with green insulation as earth dolly controlled by one switch for 6 pin, 16 Amp socket outlet on Independent board.

-

-

-

... More
Attending/checking/repairing day to day complaints of existing electrical items/points for serviceability for continuous electric supply , rectifying the no light complaints including carrying out minor repairs, checking of MCB DB, fuse & Isolator etc as required to make the item functional and replacement of small pieces of wire, screw, use of insulation tape of good quality, refixing of hanging wiring/wires and boards etc all as specified and directed by Engr-in-charge for the following : - (Note: (a) Contractor shall ensure that all complaints given by concerned JE E/M for 2 ASD area/Bde area/Jandialaguru area is attended daily within stipulated time frame (b) Contractor will provide sufficent trademans with helper for attending day to day complaints (c) The quoted rate is deemed to include the cost of providing ladders, to & for charges to site & return, carrier/arrangement to carry to ladders, tools, equipments for safty of tradesmen & helper. (d) Contractor shall provide a complaint register, complaint slip and maintain proper records of complaint attended by their elect/helper (d) Any other replacement of items shall be measured & paid seperately as supply & fix in replacement or as the case may be under respective items of this schedule.)

-

-

-

... More
Supply and fix Angular holder insulated body with back plate suitable for batten fittings including taking down unserviceable holders complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix Switch piano type, polycarbonate one way 6 Amp including taking down unserviceable switch complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix Switch piano type, polycarbonate two way 6 Amp including taking down unserviceable switch complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix switch, 6 pin ,16 Amps, flush type, polycarbonate, multipurpose, with indicator, 230 / 250 volts including taking down of unserviceable one complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix Switch bell push 6 Amps, flush button type, polycarbonate, SP, one way, 230 Volts including taking down old unserviceable onecomplete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix socket out let multipurpose 5 pin 6 Amps, flush type, polycarbonate, 230 / 240 Volts including taking down unserviceable socket outlet complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix Electronic fan regulator 230 volts , step type, socket type, hum free 120 watt, including taking down unserviceable fan ragulator complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with 200 Amp bus bar, earth wire and neutral link, 8 ways, 240 volts inlcuidng taking down unserviceable DB complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply & fixing sheet metal enclosures with double door, detachable gland plates flush/ mounting for MCB’s fitted with 200 Amp bus bar, earth wire and neutral link, 4 ways, 240 volts including taking down unserviceable DB complete all as specified and as directed by Engineer-in-Charge. ( Make- Havells/Legrand)

-

-

-

... More
Supply and fix MCB, 6 to 32 Amp, SP, 240 Volt including taking down old burnt/unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. Make : Legrand RX3 or equivalent in Schneider/Siemens

-

-

-

... More
Supply and fix MCB, 32 to 63 Amp, SPN, 240 Volt including taking down old burnt/unserviceable MCB complete all as specified and as directed by Engineer-in-Charge. Make : Legrand RX3 or equivalent in Schneider/Siemens

-

-

-

... More
Material and labour for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) including taking down old unserviceable ceiling rose complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Material and labour for bell multi music typeDing Dong, AC 230 Volts, single pole (ISI Marked) including taking downof unserviceable one complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Material and labour for repairing the existing LED tube light fitting 18/20 watt of any make or type by providing suitable driver, and checking connection etc and providing new LED tube rod of 18/20 watt complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix in repair CFL 36 Watt 4 pin in existing 2 x 36/3 x 36 watt recess mounting fitting complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix in repair laminated sheet 8" x 4" including switch, socket, regulator fix on laminated sheet including providing new screws, nuts bolts etc complete fix laminated sheet etc on wall complete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply and fix in replacement Electronic Ballast 36/40 watt for Tube light fitting 36/40 watt complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj/Philips/CG

-

-

-

... More
Supply and fixing in replacement LED bldg security light fitting 15 watt Powder coated pressure die cast aluminium compact LED security light including 1.5 mtr long 40 mm bore GI pipe mounting bracket made to shape for fixing on wall with 40 mm x 6 mm flat iron clamp 02 numbers with 16 mm dia bolts, nuts and washers all as specified and directed by Engineer-in-Charge.Make- C&S Product Code DRACO/15W Ordering Code - LTESS15WLED or equivalent in Bajaj/Philips/Crompton: Contractor shall provide 1 years written manufactures warranty for the LED fixture complete including driver from the certified date of completion.

-

-

-

... More
Material and labour for submain wiring with 4 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 10.0 Sq mm 1100 volts grade including and10.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/steel rigid conduit including taking down unserviceable sub main wiring complete all as specified and as directed by Engineer-in-Charge. Note : Five run of 10 Sqmm cable shall be measured & paid as one unit.

-

-

-

... More
Material and labour for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 6.00 Sq mm 1100 volts grade including and 6.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/steel rigid conduit including taking down unserviceable sub main wiring complete all as specified and as directed by Engineer-in-Charge. Note : Three run of 6.0 Sqmm cable shall be measured & paid as one unit.

-

-

-

... More
Material and labour for submain wiring with 2 single core PVC insulated unsheathed multi stranded copper conductor FRLS wire 4.00 Sq mm 1100 volts grade including and 4.00 Sq mm PVC insulated, multi stranded, unsheathed copper wire green in colour as earthing lead drawn through in existing PVC/steel rigid conduit including taking down unserviceable sub main wiring complete all as specified and as directed by Engineer-in-Charge. Note : Three run of 4.0 Sqmm cable shall be measured & paid as one unit.

-

-

-

... More
Supply and fix MCB 32 to 63 Amp, TP 240 volts including taking down old unserviceable one complete all as specified and as directed by Engineer-in-Charge. Make : Legrand RX3 or equivalent in Schneider/Siemens

-

-

-

... More
Supply and fix MCB 32 to 63 Amp, TPN 240 volts including taking down old unserviceable complete all as specified and as directed by Engineer-in-Charge. Make : Legrand RX3 or equivalent in Schneider/Siemens

-

-

-

... More
Supply and fix in repair LED tube light fittings 1 x 20 W, 230 V, Self ballasted LED Batten, Extruded Aluminium body with PC diffuser, with all accessories, pre-wired, fixed on wall/ceiling and connecting upto with 3 core flexible cable white of size 23/0.0076 including LED tube rod 20 watt complete all as specified and as directed by Engineer-in-Charge. Make: Polycab cat part No PCGLB VX 20 65 or equivalent in Philips/Wipro/Bajaj.

-

-

-

... More
Supply & fix in repair LED slim panel 36 Watt, having white powder coated extruded Aluminium body with high quality LGP and PMMA diffuser, sepearate HPF driver, suitable for Armstrong and Grid ceiling with necessary fitting on false ceiling as required complete all as specified and as directed by Engineer-in-Charge. Make : C&S CYGNUS 36 W/W Cat Part No LTCRSLM36WATT2X2

-

-

-

... More
Supply and fix in repair distribution board 4 way TPN double door as incomer with MCCB 63 Amp TPN breaking capacity 16 KA , MCCB is pre fitted at factory complete all as specified and as directed by Engineer-in-Charge. Make : Indo Asian Cat part No KSL 04 or equivalent in Havells/Standard

-

-

-

... More
Material and labour for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.

-

-

-

... More
The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. Item includes cost of 7.50m earth lead wire/strip.PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc including dismantling of existing one shall be deemed included in the unit rate.

-

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.

-

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.

-

-

-

... More
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenchescomplete all as specified and as directed by Engineer-in-Charge.

-

-

-

... More
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.

-

-

-

... More
Supply, laying jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade ( heavy duty) with stranded aluminium conductor, cross sectional area 25 sqmm 4 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified and as directed by Engineer-in-Charge. Note : (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.

-

-

-

... More
Supply, laying jointing and testing 1100 volts grade ( heavy duty) PVC insulated stranded aluminium conductor served with the inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or round of 10sqmm cable complete all as specified and as directed by Engineer-in-Charge.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.