Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 70,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_250408_2Bid Award Id
ViewTender No
GE(N)/M- 2019-20 NIT-04/19-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exc 1.5m above the starting point.
315
-
103
M&L for sand cushioning to under ground cables 8cm thick before laying the cable and 15cm, thick after laying, stretching and testing the cable.
290
-
104
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
10800
-
105
Laying only Sub class ‘B’ bricks old size retrieved against srl item 1 here in before laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required.
2000
-
106
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) for foundation of pole / stay including form work etc.
24
-
107
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) in coping of poles studs including form work etc complete all as specified
7.5
-
108
Taking out from trenches or wall/ pole or pipe cable LT 1100 volts grade heavy duty, armoured with steel strip of wire, with stranded aluminium conductor of any size 240 upto 400 Sqmm, any core, for rectification of faults or replacement. Seggregating serviceable cable and unserviceable lenght by meggering or any other suitable and recommended method. Removing unserviceable from site and keeping aside serviceable for reuse at same location or any other location under AGE E/M-I all as rquired at site or directed. (Earth work will be measured and paid separately under respective item).
400
-
109
All as per Srl Item 10 here in above but of size 16 Sqmm to 25 Sqmm
1500
-
110
All as per Srl Item 10 here in above but of size 35 Sqmm to 95 Sqmm
2100
-
111
All as per Srl Item 10 here in above but of size 120 Sqmm to 185 Sqmm
570
-
112
Laying only in trenches or fixed to wall/pole or passing through pipe cable LT 1100 Volts grade heavy duty, armoured with aluminium conductor of any size 240 upto 400 Sqmm any core. (Serviceable cables retrieved against srl item above will be used).
250
-
113
Supply & laying in trenches or fixed to wall/pole or passing through pipe cable LT 1100 volts grade heavy duty, XLPE insulated, armoured heavy duty electric cable, with alumn conductor of any size 16 Sqmm x 4 core.
800
-
114
All as per Srl Item 15 here in above but of size 25 Sqmm X 3.5 core.
700
-
115
All as per Srl Item 15 here in above but of size 35 Sqmm X 3.5 core.
600
-
116
All as per Srl Item 15 here in above but of size 50 Sqmm X 3.5 core.
500
-
117
All as per Srl Item 15 here in above but of size 70 Sqmm X 3.5 core.
600
-
118
All as per Srl Item 15 here in above but of size 95 Sqmm X 3.5 core.
400
-
119
All as per Srl Item 15 here in above but of size 120 Sqmm X 3.5 core.
250
-
120
All as per Srl Item 15 here in above but of size 150 Sqmm X 3.5 core.
200
-
121
All as per Srl Item 15 here in above but of size 185 Sqmm X 3.5 core.
120
-
122
All as per Srl Item 15 here in above but of size 400 Sqmm X 3.5 core.
150
-
123
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 sqmm 3½ core core with working voltage 1100 volts.
8
-
124
M&L for cable end termination kit in door/out door, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 sqmm 3½ core core with working voltage 1100 volts.
8
-
125
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 25 Sqmm to 50 Sqmm3½ core core with working voltage 1100 volts.
5
-
126
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 70 Sqmm to 150 Sqmm3½ core core with working voltage 1100 volts.
5
-
127
M&L for cable jointing kit straight through, heat shrinkable type suitable for XLPE/ PVC cables of size 185 Sqmm to 240 Sqmm3½ core core with working voltage 1100 volts.
3
-
128
Taking up of unserviceable 100mm bore GI pipe all as specified and directed by EIC.
20
-
133
Taking up of unserviceable 80mm bore GI pipe all as specified and directed by EIC.
20
-
134
Taking up of unserviceable 40mm bore GI pipe all as specified and directed by EIC.
40
-
135
Taking up of unserviceable 20mm bore GI pipe all as specified and directed by EIC.
100
-
136
Material and labour for GI tubing light grade 100mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
20
-
137
Material and labour for GI tubing light grade 80mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.
20
-
138
Boring of hole under road,pavement, hard standing by boreing hand machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure.
20
-
139
Dismentaling of LT Panel outdoor type, bus bar 300 amps rating made of aluminium strip from site directed by Engr - in- Charge complete all specified and directed.
2
-
140
Supply, installation, commissioning and testing LT panel outdoor type of size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 300 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C-1 with 20mm graded stone aggregates totally tested as per IEC 61439-I, suitable for and including the following:- (i) MCCB 4 pole 415 volts 200 amp rating thermal based release with rupturing capacity 36 KA - 01 No as incomer , Make-Legrand ,Siemens 3VL/Schneider (ii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 63 amps - 05 Nos for outgoing , Make-Legrand ,or equivalent make- Siemens 3VL/Schneider (iii) MCB SPN 32 AMP- 09 No. (iv) Indicator set RYB -01 Set of 3 pcs only Make- L & T (v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio Make- Schneider cat no. 30002567 or equilent/ L & T / Legrand (Vi) MCB, SP 10 amps Make-Legrand/Hager -03 Nos Make- legrand /Hager ( for metering equipment) (vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
1
-
141
Dismentaling of LT Panel outdoor type, bus bar 600 Amps rating made of aluminium strip from site directed by Engr - in- Charge complete all specified and directed.
2
-
142
Supply, installation, commissioning and testing LT panel outdoor type suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 600 Amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply, hibling, cable entry boxes, cable gland incl 50x50x6mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C-1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I, suitable for and including the following:- (i) MCCB 4 pole 415 volts 400 amp rating microprocessor based release with rupturing capacity 50 KA - 01 No as incomer, Make-Legrand, Siemens 3VL/Schneider. (ii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 200 amps - 02 Nos for outgoing , Make-Legrand ,or equivalent make- Siemens 3VL/Schneider NSX. (iii) MCCB 3 pole 415 volts withmicroprocesser release rupturing cap 25 KA, 160 amps - 02 Nos for outgoing , Make-Legrand, equivalent make- Siemens 3VL/Schneider NSX. (iv) Indicator set RYB -01 Set of 3 pcs only Make- L & T. (v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio Make- Schneider cat no. 30002567 or equilent/ L&T / Legrand. (Vi) MCB ,SP 10 amps Make-Legrand/Hager -03 Nos. Make- legrand /Hager ( for metering equipment). (vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
1
-
143
Supply, installation, commissioning and testing LT panel outdoor type suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 300 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply, hibling, cable entry boxes, cable gland incl 50x50x6mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C-1 with 20mm graded stone aggregates totally tested as per IEC 61439-I, suitable for and including the following:- (i) MCCB 4 Pole 415 volts 200 amp rating microprocessor based release with rupturing capacity 50 KA - 01 No as incomer , Make- Schneider, Legrand, Siemens 3VL. (ii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 100 amps - 03Nos for outgoing, Make-Legrand, or equivalent make- Siemens 3VL/Schneider NSX. (iii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 63 amps - 01Nos for outgoing, Make-Legrand, or equivalent make- Siemens 3VL/Schneider NSX. (iv) MCB SPN 32 AMP 03 NO. (v) Indicator set RYB -01 Set of 3 pcs only Make- L&T. (vi) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio Make- Schneider cat no. 30002567 or equilent/ L & T / Legrand. (Vii) MCB, SP 10 amps Make-Legrand/Hager -03 Nos Make- legrand /Hager ( for metering equipment) (viii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
1
-
144
Supply, installation, commissioning and testing LT panel outdoor type suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 600amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4mm wire 415 volts 50 HZ AC supply, hibling, cable entry boxes, cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C-1 with 20mm graded stone aggregates totally tested as per IEC 61439-I , suitable for and including the following:- (i) MCCB 4 Pole 415 volts 400 amp rating microprocessor based release with rupturing capacity 50 KA - 01 No as incomer, Make- Schneider, Legrand, Siemens 3VL. (ii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 250 amps - 02 Nos for outgoing, Make-Legrand, or equivalent Make- Siemens 3VL/Schneider NSX. (iii) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 200 amps - 02Nos for outgoing, Make-Legrand, or equivalent make- Siemens 3VL/Schneider NSX. (iv) MCB SPN 32 AMP 03 NO. (v) Indicator set RYB -01 Set of 3 pcs only Make- L & T including CTs of appropriate ratio Make- Schneider cat no. 30002567 or equilent/ L & T / Legrand. (Vii) MCB, SP 10 amps Make-Legrand/Hager -03 Nos Make- legrand /Hager (for metering equipment). (viii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
1
-
145
Dismentaling of LT Panel outdoor type, bus bar 200Amps rating made of aluminium strip from site directed by Engr - in- Charge, complete all specified and directed.
2
-
146
Supply, installation, commissioning and testing LT panel outdoor type suitable size recommended by manufacturer cubical floor mounted type (IP-65 degree of protection) made out of 3mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200Amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4mm wire 415 volts 50 HZ AC supply, hibling, cable entry boxes, cable gland incl 50x50x6 mm frame (bottom portion of the panel), grouted by using foundation 1:2:4 type C-1 with 20mm graded stone aggregates totally tested as per IEC 61439-I, suitable for and including the following:- (i) MCCB 3 pole 415 volts with thermal based release rupturing cap 25 KA, 100 amps-01Nos for incoming, Make-Legrand ,or equivalent make- Siemens 3VL/Schneider. (ii) MCCB Single pole 230 volts with thermal based release rupturing cap 16 KA, 63 amps - 03Nos for outgoing, Make-Legrand, or equivalent make- Siemens 3VL/Schneider. (iii) Supply and fix time switches astro type (Having longitude and latitude of Indian cities in memory) 250 V single phase of 20Amp rating with contactor fitted inside steel enclosure.
2
-
147
Taking down carefully aluminium conductor of any size from LT OH Lines after unbinding from insulators for replacement of multijointed / undersize conductors.
15
-
148
M&L for ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed.
10
-
149
Restringing and restretching aluminium conductor reterived under item srl 46 above including necessary binding with insulators using alunimium binding wire, connections of incoming and out going cables complete all as specified and directed.
5
-
150
Restretching aluminium conductor or GI wire on existing over head lines without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire, connections of incoming and out going cables, binding with spacers where required, complete all as specified. (Note:- For measurement length of each conductor shall be taken seperately.
8
-
151
Taking down carefully earth wire of any size from LT OH Lines after unbinding from insulators for replacement of GI wire.
2
-
152
M&L for GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
2
-
153
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of alumn paint.
3
-
154
Taking down/Dismantling insulators carefully any type, any size.
70
-
155
M&L for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
40
-
156
M&L for pin insulators 75mm height and 90mm dia size porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts complete all as specified, required at site or directed.
30
-
157
M&L for stay assembly using GI stay rod 20mm dia complete with stay plate mild steel of size 300x300x6.00mm thick, stay bow complete all as specified and shown in Electrical Plate No 1. (Necessary earth work, stay wire, loop insulator,clamps and PCC shall be measured and paid seperately) complete all as specified and directed.
8
-
158
M&L for Galvanised stay wire of size 7/4mm all as specified and directed.
2
-
159
M&L for loop type insulator large size porcelain vitirious of size 90 x 140 mm clearence of hole 16mm complete all as specified and directed.
30
-
160
M&L for prestresed cement concrete pole 9 mtr long, 102 mm x 172mm at top and 102mm x 279mm at bottom class-10 complete, erected truly in vertical position and painting the poles with synthetic enamel paint upto 1.5 mtr from the coping above the ground level with alternate layer of 30 cm width with black and yellow paint complete all as specified and directed by Engr-in-Charge. (Earth work and PCC will be measured and paid separately under respective items).
25
-
161
M&L for steel tubular swaged pole 9m long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally up to planting depth, alternative green & white strips of 30 cm width upto 1.5m above ground level all as required at site or directed by Engr-in-charge.
10
-
162
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed, Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) Total length of line from supply point to load end will be measured for the purpose of payment, irrespective of the No of trees required to be trimed. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and out come whether lines are free from tree branches or not kept on record for payment. No payment is made for whole length if even single tree is within reach of OH line. (iv) The OH line will be maintained for whole period of contract and the payment will be made with final bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above.
15
-
163
Taking down street light fitting or flood light, garden lights fitting any type and rating from poles, walls or any other indicated situation/location including removal of GI bracket pipe as directed, after disconnecting electrically. and unservicable fittings and accessories from site.
50
-
164
Supply and fixing LED street light fitting 45 Watts, made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening, seperate driver compartment with IP66 protection and impact resistance of IK07 complete making connection with street light box or OH line using PVC insulated and sheathed single core multi stranded aluminium coductor cable of size 1.5 Sqmm all as directed by Engr - in - Charge
Notes:- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K.
5. System Lumen Efficacy shall be 100Lm/W
6. 10 KV separate Surge Protection shall be provided as a part of fitting.
7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type
50
-
165
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x4mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge.
10
-
166
Supply and replecement on wall by grouting the suitable size of nut bolts and make good the disturbed surface with existing specifications of ON LOAD Change over switch with advance neutral of front handle operated type 415Volts 4 pole in sheet metal enclosure of capacity 100 Amp. Make : Havells/Legrand
2
-
167
Supply and laying in trenches/on piller GI Pipe 40 mm bore dia medium grade ISI marked including all fitting and accessories, laid in trenches/under road/on wall/under floor or in air for connection of ditch all as complete as per site requirement for watering purpose of earthing.
40
-
168
Supply and fixing Gun metal gate valve 40mm dia with iron wheel head, screwed both ends for iron pipe fixing heavy duty ISI marked all as specified and directed.
6
-
169
Supply and laying in trenches/on piller GI Pipe 20 mm bore dia medium grade ISI marked including all fitting and accessories, laid in trenches/under road/on wall/under floor or in air for connection of ditch all as complete as per site requirement for watering purpose of earthing.
100
-
170
Supply & fix Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
12
-
171
Scraping of old paint from steel section of outdoor sub stn having area not more than 6 Sqmtr without removing accessories and preparation of surfaces for repainting. Repainting all metal parts including fencing with one coat of alumn paint. Painting PCC or cemented surfaces with Apex paint of approved colour all as required ta site or directed.
10
-
172
Scraping of old paint from steel section of outdoor sub stn having area more than 6 Sqmtr without removing accessories and preparation of surfaces for repainting. Repainting all metal parts including fencing with one coat of alumn paint. Painting PCC or cemented surfaces with Apex paint of approved colour all as required ta site or directed.
10
-
173
Supply ande fixi Mild steel sliding door bolts 250mm, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed all as directed by Engr in charge.
50
-
174
Supply and fix Butt hinges, 125mm long heavy weight cold rolled mild steel all as directed by Engr in charge.
100
-
175
Balacing of load in R,Y,B phase of UG cable of one transformer of 5 LT panels having 10 Nos blocks feeder at Bhattacharjee/Shivalik/Dhauladhar enclave or any Md Accn of Mamun cant by Addition alteration of cable in DB / over head conductor / LT panel of feeder and find out and made equal load balancing in transformer LT side as specifeid and directed at site by Engr -in-charge' Note : Prepare load balancing chart each and every Qtr network.
18
-
176