Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Water Storage And Supply
Eprocure
Opening Date23 Oct 2024
Closing Date20 Nov 2024
Tender Amount₹ 12,00,000
Costs
EMD
₹ 24,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Certain Repairs/replacement/cleaning Of Manholes, Septic Tanks And Sewage Lines At Old Mil Stn Kapurthala Under Ge Kapurthala.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680885_1Bid Award Id
ViewTender No
GE KPT- /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Certain Repairs/Replacement/Cleaning of manholes, septic tanks and sewage lines at Old Mil Stn Kapurthala under GE Kapurthala.
Certain Repairs/Replacement/Cleaning of manholes, septic tanks and sewage lines at Old Mil Stn Kapurthala under GE Kapurthala.
Certain Repairs/Replacement/Cleaning of manholes, septic tanks and sewage lines at Old Mil Stn Kapurthala under GE Kapurthala.
BOQ Items
M&L for pumping out liquid or semi liquid from sewage wells/septic tanks/soakage pit of any size or any depth mechanically by sucking mechanical machine system (closed tank) and dispose off the same from out of defence land complete all as specified and directed by Engr-in-Charge.
Note:-During the cleaning of sewage wells, septic tanks and soakage pit the alternate temporary arrangemants shall be made by the contractor for clearing sewage disposal. No pumping is allowed in defence land.
400
-
-
M&L for cleaning sewage lines of dia 150/200/300 mm as in main sewage system having depth not exceeding 1.50 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge.
Note:- Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine for cleaning of central sewer pipe lines from manhole to manhole.
2000
-
-
M&L for cleaning sewage lines of dia 150/200/300 mm as in main sewage system having depth exceeding 1.50 mtr but not exceeding 3.00 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge. Note:- Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine for cleaning of central sewer pipe lines from manhole to manhole.
1000
-
-
M&L for cleaning sewage lines of dia 150/200/300 mm as in main sewage system having depth exceeding 3.00 mtr but not exceeding 4.50 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge. Note:- Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine for cleaning of central sewer pipe lines from manhole to manhole.
200
-
-
M&L for breaking up/puncturing existing badly blocked lines and clearing blockage before puncturing by excavating a manhole of suitable depth and size as directed by the Eng-in-charge at site complete all as specified and directed by Engr-in-Charge. Note:- The different items involved in excavating manhole shall be measured and paid for separately under appropriate items of Sch 'A'.
12
-
-
Demolition of concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge.
2
-
-
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge.
6
-
-
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed by Engr-in-Charge.
10
-
-
M&L for Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4, complete all as specified and directed by Engr-in-Charge.
10
-
-
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cm 1:4 finished even and smooth without using extra cement,complete all as specified & directed.
100
-
-
Excavation in trenches not exc 1.5 m wide & n.exc 1.5 m in depth for foundation, sewage lines and man holes etc n.exc 10 Sqm on plan & n.exc 1.5 m in depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
250
-
-
Excavation in trenches not exc 1.5 m wide & n.exc 3 m in depth for foundation sewage lines and man holes etc n.exc 10 Sqm on plan & exc. 1.50 m but n.exc 3 m in depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
100
-
-
Excavation in trenches not exc 1.5 m wide & n.exc 4.5 m in depth for foundation sewage lines and man holes etc n.exc 10 Sqm on plan & exc. 3.00 m but n.exc 4.50 m in depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
25
-
-
Demolition and breaking up 150 mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and directed by Engr-in-Charge.
100
-
-
Demolition and breaking up 200 mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and as directed by Engineer-in-Charge.
95
-
-
Demolition and breaking up 300 mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and directed by Engr-in-Charge.
75
-
-
S&F Reinforced concrete pipes, 150 mm Dia class NP2, laid and jointed complete all as specified and directed by Engr-in-Charge.
100
-
-
S&F Reinforced concrete pipes, 200 mm Dia class NP2, laid and jointed complete all as specified and directed by Engr-in-Charge.
95
-
-
S&F Reinforced concrete pipes,300MM Dia class NP2, laid and jointed complete all as specified and directed by Engr-in-Charge.
75
-
-
Returning filling in incl spreading leveling and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engr-in-Charge.
150
-
-
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed by Engr-in-Charge.
150
-
-
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation of man holes complete all as specified and directed by Engr-in-Charge.
5
-
-
M&L for PCC 1:2:4 type B-0 (using 20 mm graded agg) as in coping, benching of Man holes, complete all as specified and directed by Engr-in-Charge.
3
-
-
M&L for pre cast cement concrete 1:2:4 as in man hole covers type B-1 (20 mm graded agg) as in manhole cover set in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
3
-
-
S&F for TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engr-in-Charge.
300
-
-
S&F for TMT bars 6mm to 8 mm dia and over, cut to length, bent to shape required, including binding with mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed by Engr-in-Charge.
100
-
-
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 150mm bore pipe complete all as specified and directed by Engr-in-Charge.
45
-
-
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 200mm bore pipe complete all as specified and directed by Engr-in-Charge.
95
-
-
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 300mm bore pipe complete all as specified and directed by Engr-in-Charge.
50
-
-
M&L in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
20
-
-
Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150/200/300mm bore drain pipe, complete all as specified and directed by Engr-in-Charge.
10
-
-
Cleaning and removing all scale and dirt, etc from tanks and from mouth of circulating pipes exc 500 and n exc 1000, complete all as specified and directed by Engr-in-Charge.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements