Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666291_2Tender No
8324/17/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
15 TR Capacity installed at 23 FAD ( No. 20).
3
-
-
... More
27 TR Capacity installed at 23 FAD Mag No 24 & Mag No 25.
3
-
-
... More
Maintenance, overhauling & servicing the Package Type A C Plants of capacity 11 TR at 23 FAD (27 A) water cooled type complete including cleaning, greasing of blower motor etc of following Capacities by trained and qualified Mechanics of including replacement of unserviceable Spare parts ,leak test by nitrogen gas and charging the refrigerant as required at site & test run for 24 hrs to achieve satisfactory complete all as specified and directed :-
2
-
-
... More
All as per item No 6 above but of capacity 11 TR at 23 FAD (27 B) Water cooled type.
2
-
-
... More
All as per item No 6 above but of capacity 11 TR at 23 FAD (Mag No 1) Water cooled type.
2
-
-
... More
All as per item No 6 above but of capacity 11 TR at 23 FAD (Mag No 2) Air cooled type.
2
-
-
... More
All as per item No 6 above but of capacity 22 TR at 23 FAD (Mag No 3) Air cooled type.
2
-
-
... More
All as per item No 6 above but of capacity 22 TR at 23 FAD (Mag No 4) Air cooled type.
2
-
-
... More
Material & Labour for carrying out the chemical servicing of the Air Handling units of both inside & outside cooling coils by applying the non-aciditic scale removing agent to the fins area of the cooling coil, copper tubes, remove the complete scale deposit across the coil, flushing through and complete blowing out the dirt, cleaning the fan impellers, filter section, fan section and complete cleaning of filters, tightening of all bolts & nuts, renew the rusted bolts & nuts checking the alignment of the drive set and testing & commissioning the Air Handling units of AC Plant complete all as directed by Eng-in-charge :-
-
-
-
... More
60/54 TR Capacity.
2
-
-
... More
Upto 30 TR Capacity.
6
-
-
... More
M&L for Dismantling electrical connections , taking down existing cooling tower motor from cooling tower of the following capacity and carrying out the repairs by filling metal on the worn out portion of shaft,machining to the standard size of hub,removing the bend, checking the balancing and S&F new cooling tower hub and fan including fixing,testing and commissioning of various capacity of AC plants,complete all as directed by Eng-in-charge.
-
-
-
... More
60/54 TR Capacity hub with blades.
1
-
-
... More
30 TR Capacity hub with blades.
1
-
-
... More
22 TR Capacity hub with blades.
1
-
-
... More
11 TR Capacity hub with blades.
1
-
-
... More
M&L for disconnecting electical/ mechanical connections and de-coupling Motor from pump/compressor, taking down the defective Induction Motor of any make / model shifted to work shop for dismantling motor , remove burnt out winding from stator and rewinding the stator with same gauge super enamelled copper conductor with necessary insulation materials , varnishing backing re-assembling motor including replacement of both end bearings complete after complete the job motor shifted to site and reinstalled at its original position including allignment with pump/compressor with electrical connections and testing for best performance complete all as directed of the following capacities :-
-
-
-
... More
Motor upto 3 to 5 HP.
15
-
-
... More
Motor 7.5 HP to 10 HP.
10
-
-
... More
M&L for vacummising the complete system of various capacity of central type AC plants with vaccum pump as per the standard practice and charging refrigerant R-22 gas including checking of leaks and testing & commissioning of the system complete all as directed.
300
-
-
... More
M&L for vacummising the complete system of various capacity of central type AC plants with vaccum pump as per the standard practice and charging refrigerant HFC R-407 a gas including checking of leaks and testing & commissioning of the system complete all as directed.
120
-
-
... More
Supply and charge of compressor oil servo freeze in Package/ Central type AC plant of any capacity complete all as specified and directed.
150
-
-
... More
Taking down unserviceable single phase preventer and S&F new single phase preventer, 6 wires 230 V complete all as directed.
10
-
-
... More
Material & Labour for taking down the defective unserviceable solenoid valve coil and supply & fixing of new coil suitable to work in single phase, AC 220 V,50 Hz complete all as directed.
8
-
-
... More
Supply and fixing oil filter for package type chiller unit of capacity up to 22 TR.
8
-
-
... More
Material & Labour for taking down the defective/ unserviceable High Pressure cutout switch and supply & fixing of new high pressure cutout switch including connecting up the Electrical & pressure line connections and setting the cutin & Cutout pressure limits and testing the cutout switch for AC plant compressor complete all as directed.
8
-
-
... More
Material & Labour for taking down the defective unserviceable oil Pressure cutout switch and supply & fixing of new oil pressure cut out switch including connecting up the Electrical & Pressure line connection and setting the cutin & cutout pressure limits and testing the cutout switch for AC plant Compressor coplete all as directed.
8
-
-
... More
Material & Labour for taking down the defective unserviceable timer and S&F of new on delay timer HSDT2 CON-230, 0 to 30 Sec connecting the wiring & testing complete all as directed.
8
-
-
... More
Material & Labour for taking down the defective unserviceable power contactor of 3TF46 & burned out copper wire, lugs, and S&F of new power contactor 3 pole, 220-240 coil volt, including the copper wire & copper lugs and testing complete all as directed.
2
-
-
... More
S&F MPD Power supplier of capacity 5-30 Amps auxilary supply,15 V,AC 230V,50Hz,AC supply as fixed in repairs complete all as directed.
3
-
-
... More
Taking down old unserviceable 100 mm dia CI butterfly valve and S&F 100 mm dia CI butterfly valve,PN 1.0,pneumatic double acting actuator with both sides flanges and gaskets complete all as specified and directed.
6
-
-
... More
Taking down old unserviceable 50/80 mm dia CI butterfly valve and S&F 80 mm dia CI butterfly valve,PN 1.0,pneumatic double acting actuator with both sides flanges and gaskets complete all as specified and directed.
6
-
-
... More
Painting air conditioning plant complete of a capacity 20 to 60 TR chiller water type including preparation of surface by cleaning /rubbing /scrapping as required and painting with two coats of synthetic enamel paint of existing color using spray gun and marking SM MES No etc as directed on the following parts/ equipments:- Compressor and compressor motor -3 Set. Condenser /chiller pump /hot water pump -06 Nos. LT panel complete -01 No. Hot water generator -01 No. Cooling tower complete -01 No. CT fan motor -01 No. Blower fan motor -02 Nos. All water /gas pipe line -01 No.
2
-
-
... More
Material and labour repair to internal wiring / burnt out wiring of LT panel and supply and rewiring with suitable size single core PVC insulated, unsheathed multi stranded 1100 volts grade copper conductor cable of required sizes from bus bar to outgoing feeders/ starters properly lugged at end terminals , cleaning of panel board , tightening of all connections removing old burnt lugs and including replacement of Voltmeter digital type 0-500 V, Ampmeter 0-500 Amp and indicator lamp complete all as directed..
2
-
-
... More
Supply and fixing in replacement shut off valve brass body of suitable size complete all as specified and directed.
6
-
-
... More
Supply and fix in replacement, angle valve brass body of suitable size complete all as specified and directed.
6
-
-
... More
Supply and fix in replacement, filter assembly for Central type chiller unit of capacity up to 30 TR.
6
-
-
... More
Supply and fix in replacement, of Relative Humidity sensor complete all as specified and directed.
8
-
-
... More
Supply and fix in replacement, of Temperature Gauge (Digital Type) as specified and directed.
10
-
-
... More
Supply and fix in replacement, V Belt B-80 to 88 type complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
Supply and fix in replacement,V Belt B-72 type complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
Supply and fix in replacement, V Belt B-63 type complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
Supply and fix in replacement, V Belt A-20 to 30type complete all as specified & directed by Engineer-in-charge.
20
-
-
... More
M&L for replacement of micro filter of size 60x60x15cm (20 micron per filter).
20
-
-
... More
M&L for replacement of micro Hepa filter of size 60x60x30cm (5 micron per filter).
20
-
-
... More
Supply and fixing shaft bearing as per existing of blower of AHU.
4
-
-
... More
Supply and fixing 3 pole connactor MNX 18 type Coil, 240V,50/60 Hz complete.
15
-
-
... More
Material & Labour for Taking down the damage blower fan and supply & fixing new as per existing size and make including necessary fixing arrangement.
4
-
-
... More
Supply & fix in repair single phase preventor Model 1 : VSP D2 complete all as specified & directed.
4
-
-
... More
Supply & Fixing Thermel over load relay ML-2 type, 9 -15 Amp
15
-
-
... More
Supply and fixing Add on block MNX-A1 up to 415 Volt complete all specified and directed
15
-
-
... More
Supply & Fixing copper tube as per existing size
20
-
-
... More
Supply & Fixing MCCB 3 pole, 100 Amps, 415 Volt.with
breaking capacity 16 KA
3
-
-
... More
Supply and fixing MCCB 4 pole, 125 Amps, 415 Volt. with
breaking capacity 16 KA
3
-
-
... More
Supply and fixing MCCB 4 Pole 250 Amps, 415 V, Adjustable type thermal & fixed magnetc, with breaking capacity 36 KA
2
-
-
... More
Supply and fixing MCB TPN , 40 to 100 Amps 415V 10KA 'C' curve, in existing panel of AC Plant.
6
-
-
... More
Supply and fixing MCB TP , 25 to 63 Amps, 415 volt 10KA 'C' curve in existing panel of AC Plant.
6
-
-
... More
Supply and fix in replacement, MCB SPN 20/25 A 240V, 10KA 'C' curve complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement, MCB SP 5-52 Amp 240V, 10KA 'C' curve complete all as specified and directed.
10
-
-
... More
Material and labour for servicing Electric control panel complete with replacement necessary burnt wiring, lugs, replacement of necessary insulators and u/s parts, saddeling and bunching of cable properly for smooth functioning of the plant all as directed by Engr-in-Charge at site.
2
-
-
... More
Supply and fixing Fan belt of Blower motors (AHU).
10
-
-
... More
Supply and fixing Fan blelt of compressor motors.
10
-
-
... More
Material & Labour for taking down the defective/ unserviceable High Pressure & Low Pressure combination cut out switch and supply & fixing new HP & LP combined switch including connecting the circuit wiring, pressure line connections and setting of the cut in & cut out pressure limits and testing complete all as directed.
8
-
-
... More
Supply and fixing digital type Ammeter 4"x4" size 0-200 Amp with suitable CTs of.
6
-
-
... More
Supply and fixing digital type Voltmeter 4"x4" size 0-500 Volts with suitable CTs of
6
-
-
... More
Supply and fix in replacement, Gun-metal, globe or gate valves of 20mm with iron wheelhead, screwedboth ends for ironpipe and fixed
6
-
-
... More
Supply and fix in replacement, Gun-metal, globe or gate valves of 25mm with iron wheelhead, screwedboth ends for ironpipe and fixed
6
-
-
... More
Supply and fix in replacement, in repair, gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe, including provn of one union complete all as specified of size 65 mm bore pipe complete all as specified & directed.
2
-
-
... More
Supply & Fixing in repair PTMT Ball valve with apoxy coated alluminium rod and high density plastic ball screwed for iron pipe 15 mm dia.
8
-
-
... More
Supply & Fixing in repair PTMT Ball valve with apoxy coated alluminium rod and high density plastic ball screwed for iron pipe 20mm dia.
4
-
-
... More
Supply and fix in replacement, 32/40 mm dia Balancing valves made of Cast iron/Gun metal of PN 16 Rating as per engineering standards handle type and specifications.(For Hot water system), complete all as specified and directed.
4
-
-
... More
Supply and fix in replacement, 50 mm dia Balancing valves made of Cast iron/Gun metal of PN 16 Rating as per engineering standards handle type and specifications.(For Hot water system), complete all as specified and directed.
2
-
-
... More
Disconnecting, cutting and taking out unserviceable sealed unit compressor of Central type Air conditioner 30 Ton Capacity any make & model suitable for site requirment including removal, fitting/fixing of serviceable sealed unit compressor,(brought against srl item No 77 here-in-after) soldering, welding, brazing as required including charging of refrigerant gas including change expension valve and oil in the exchanged compressor, making electric & mechanical connections at site and testing on load, complete old unsv compressure deposite in MES yard complete all as specified and directed.
1
-
-
... More
Supply & Fixing with provision of clean, exchange of unserviceable compressor (removed against item No 76 here-in-before) with company made new one sealed compressor of central type air conditioner 30 Ton capacity, complete with control arrangement all as specified and directed. Note :- After fixing of new compressor testing will be done its own arrangement test run for 24 hrs to achieve satisfactory complete all as specified and directed.
1
-
-
... More
Disconnecting, cutting and taking out unserviceable sealed unit compressor of pckage type Air conditioner 5.5 Ton Capacity any make & model suitable for site requirment including removal, fitting/fixing of serviceable sealed unit compressor (brought against srl item No 79 here-in-after), soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections at site and testing on load, complete all as specified and directed.
1
-
-
... More
S&F with provision of clean, exchange of unserviceable compressor (removed against item No 66 hre-in-before) with company made new one sealed compressor of package type air conditioner 5.5 Ton capacity, complete with control arrangement all as specified and directed. Note :- After fixing of new compressor testing will be done its own arrangement test run for 24 hrs to achieve satisfactory complete all as specified and directed.
1
-
-
... More
S&F of PCB for hot water control panel of any capacity / make including checking the all components, replacing demaged minor components with new ones, making the PCB fully functional till Hot water system testing Engineer-in-Charge satisfaction complete all as specified and directed.
6
-
-
... More
Supply and fixing of New PCB alongwith all accessories as per existing model / sample suitable for chilling unit of pakage type AC unit any capacity 11/22 TR fixed on existing system by any fixing method and making electrical connection including taking down of existing unsv PCB complete and produce test certificate all as specified and directed by Engineer-in-Charge.
2
-
-
... More
M & L for rewinding of electric motor of capacity 1/1.6/2 HP incl dismatling, carrying to workshop and transporting back and testing thereafter up to the satisfaction of Engr in charge.
4
-
-
... More
Repair to damage/leckage cooling tower FRD type with suitable material/chemical complete all as specified and directed.
4
-
-
... More
Complete servicing and repairing of cooling tower any make any size incl dismatling of unserviceable part & fins if any and replacing with same specification, making body of tower serviceable testing up to the entire satisfaction of Engineer-in-charge
4
-
-
... More
Supply & fixing ball bearing SKF 6308 or equivalent complete all as specified and directed.
10
-
-
... More
Repair to HOT water genertor system electric panel complete make repaid cool capacity upto 50 KW including replacement of minor part like copper wire, lugs, ON/OFF switch & rellay complete all as specified and directed.
4
-
-
... More
S&F of heating elements of capacity 2 KW complete all as specified and directed.
16
-
-
... More
Repair/Cleaning of condenser coils by descaling complete in all respects of upto 54 TR AC plant
3
-
-
... More
S&F of leakage of 25 mm 'med grade ' GI pipe suitable for plant up to outside the plant room incl making good to disturbed surfaces of wall
20
-
-
... More
M & L Cleaning of air filter, Cleaning of cooling coils assembly of AHUs 10000 CFM, 14000 CFM with descaling solution to remove deposited scale/dust including cleaning of tubes with wire brush to the entire satisfaction of Engineer-in-charge complete all as specified and directed
6
-
-
... More
Repairing of electronic expansion valve upto 150 TR for any gas system.
4
-
-
... More
S & F electronic valve type 5 of suitable size complete all as specified and directed.
4
-
-
... More
Repair to condenser unit Make-Accel/Voltas by dismating carefully for replacement of worn out part from unit and transporting to workshop, opening up for carrying out the necessary repair/replacement of worn out parts, lath/machinery work incl proper clean of condenser coil and re-assembling condenser unit transporting back to site,refixing with electric motor and testing for proper functioning complete all as specified and directed. However the unit rates quoted against this item shall include the cost of fixing all type of spares, fixing, minor parts such as bolts, nuts, washers, gasket set, seal etc and also supplying and charging of oil charging after ensuring entire system leak proof complete all as specified and directed
4
-
-
... More
Compressive maint for general complaints the non functioning AC plant complaints due to the minor defect like electric suppy/pump & moter/ cooling/ blower/ AHU/ switch / leckage of water by deploying sufficient labour (Skilled and helpers) for repair to minor repair of any description such as at any location complete all as specified.
NOTE:-
(i) Rates quoted by the contractor shall be deemed included the cost of necessary items like Nut & Bolt, cable lugs, PVC wire, Gland & required T&P. ( ii) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (iii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor.
(iv) Confirmation of attendance & rectification of complaint shall be given by the contractor. (v) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (vii) Major parts and cost of repair to AC plant shall be measured and paid separately under respective items.
150
-
-
... More
M&L for leak arresting of chilled water pipes of size 50/65 mm dia bore including replacement of MS flanges, gaskets, bolts, nuts etc complete to make the lines water tight as directed by Engr-in-charge
1
-
-
... More
M&L for disconnecting, opening, for overhauling the water cooled type compressor unit complete with condenser capacity 30 TR AC Plant Make ACCEL dismating carefully for replacement of worn out part from unit and transporting to workshop, opening up for carrying out the necessary repair/replacement of worn out parts including lath/machinery work, re-assembling compressor transporting back to site,refixing with electric motor and testing for proper functioning complete all as specified and directed at 23 FAD and and repair/ replacment of the following components/worn out parts all as specified and directed by Engr-in -charge
3
-
-
... More
(b) Piston Ring set -01 set
-
-
-
... More
(c) AHU solonoid valve -01 Nos
-
-
-
... More
(d) Oil Pump assemble -01 Nos
-
-
-
... More
(e) Rocker Arm -04 Nos
-
-
-
... More
(f) Piston assembly -01 set
-
-
-
... More
(g) Gasket set complete -01 set
-
-
-
... More
(g) Suction and discharge road -01 set
-
-
-
... More
Note : - (i) All repair work will be done by authorised/ trained and qualified Mechanics
-
-
-
... More
(ii) Testing of complete compressor unit after re-assembly the unserviceable Spare parts ,leak test by nitrogen gas and charging the refrigerant & oil as required at site & test run for 24 hrs to achieve satisfactory complete all as specified and directed
-
-
-
... More
(iii) Required all other minor parts like nut, bolt, grease, seal etc included in coated rate.
-
-
-
... More
(iv) Required refrigerent and compressure Oil dept will be paid through relevent items.
-
-
-
... More
M&L for disconnecting, opening, for overhauling the water cooled type compressor unit complete with condeneser capacity 15 TR AC Plant co Make ACCEL dismating carefully for replacement of worn out part from unit and transporting to workshop, opening up for carrying out the necessary repair/replacement of worn out parts including lath/machinery work, re-assembling compressor transporting back to site,refixing with electric motor and testing for proper functioning complete all as specified and directed at 23 FAD and and repair/ replacment of the following components/worn out parts all as specified and directed by Engr-in -charge
1
-
-
... More
(a) Shaft Polishing -01 Nos
-
-
-
... More
(b) Piston Ring set -01 set
-
-
-
... More
(c) AHU solonoid valve -01 Nos
-
-
-
... More
(d) Oil Pump assemble -01 Nos
-
-
-
... More
(e) Rocker Arm -04 Nos
-
-
-
... More
(f) Rocker Arm Cup
-
-
-
... More
(g) Gasket set complete-01 set
-
-
-
... More
Note : - (i) All repair work will be done by authorised/ trained and qualified Mechanics
-
-
-
... More
(ii) Testing of complete compressor unit after re-assembly the unserviceable Spare parts ,leak test by nitrogen gas and charging the refrigerant & oil as required at site & test run for 24 hrs to achieve satisfactory complete all as specified and directed
-
-
-
... More
(iii) Required all other minor parts like nut, bolt, grease, gasket etc included in coated rate.
-
-
-
... More
(iv) Required refrigerent and compressor Oil dept will be paid through relevent items.
-
-
-
... More
S&F MCCB 400 Amps 3 pole 415 Volts 36KA breaking capacity Adjustable type thermal & fixed magnetic with spreader complete all as specified and directed.
2
-
-
... More
Supply& Fixing of start/stop push button with Led indicator red/ green type -240 Volt Ac as per exiting sample/ size complete all as specified and directed.
15
-
-
... More
Supply& Fixing of volt visel switch as per exiting sample/ size complete all as specified and directed.
4
-
-
... More
Supply, & fixing of Pressure gauge 4"dial 0-21 kgs rating complete all as specified and directed
12
-
-
... More
Supply, & fixing liqid line core filter complete all as specified and directed
6
-
-
... More
Supply, & fixing section gauge 0 to 300mm complete all as specified and directed
12
-
-
... More
M&L for repair of PLC control panel complete of 30 TR capacity / make voltas including repair of PCB checking the all components, replacing demaged minor components with new ones, making the PLC fully functional complete all as specified and directed.
3
-
-
... More
S & F for New PLC control unit of 30 TR capacity / make voltas complete with new PCB including checking the all components, making the PLC fully functional satisfaction complete all as specified and directed.
2
-
-
... More
S & F `Y' Stainer 10mm dia with filter complete all as specified and directed.
4
-
-
... More
S&F of heating strip of capacity 2 KW for hot water system complete all as specified and directed.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%