If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jan 2025
Closing Date28 Feb 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Summary

Repair / Maint To Dg Sets, Amf Panels, Fire Fighting System, Installations, Renewal Of Earthing, Installation Of Recd And Connected E/m Works Under Ge (east) Jalandhar Cantt

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
320 KVA Make : Kirloskar

2

-

-

... More
250 KVA Make : M&M

4

-

-

... More
200 KVA Make : Ruston, Kirloskar

6

-

-

... More
180 KVA Make : Crompton Greaves,

2

-

-

... More
160 KVA, MAKE: Cummins, M&M

4

-

-

... More
125/100 KVA, MAKE: Kirloskar, Ashok Leyland ,CG

5

-

-

... More
82.5 KVA Make: Crompton Greaves

2

-

-

... More
62.5/55 KVA, MAKE: Kirloskar, Mahindra, Ashok Leyland & Crompton Greaves

8

-

-

... More
15/12.5KVA, Chattri Chowk Exchange , MAKE:Crompton Greaves, Kirloskar

4

-

-

... More
10/7.5 KVA, 250 ASC Supply , MAKE: Mahindra, Kirloskar

6

-

-

... More
Supply only B' Check Kit for DG sets of following capacities:- Note : It Includes Oil filter (1.00 Ltr/0.5 ltr), Diesel filter, by pass element

-

-

-

... More
400 KVA Make : M&M

1

-

-

... More
320 KVA Make : Kirloskar

1

-

-

... More
250 KVA Make : M&M

2

-

-

... More
200 KVA Make : Ruston Horntery, Kirloskar

4

-

-

... More
180 KVA Make : Crompton Greaves,

1

-

-

... More
160 KVA, MAKE: Cummins, M&M

2

-

-

... More
125/100 KVA, MAKE: Kirloskar, Ashok Leyland ,CG

5

-

-

... More
82.5 KVA Make: Crompton Greaves

1

-

-

... More
62.5/55 KVA, MAKE: Kirloskar, Mahind, Ashok Leyland & Crompton Greaves

4

-

-

... More
15/12.5KVA, Chattri Chowk Exchange , MAKE:Crompton Greaves, Kirloskar

3

-

-

... More
10/7.5 KVA, 250 ASC Supply , MAKE: Mahindra, Kirloskar

3

-

-

... More
Disconnecting all the connections from alternator of DG Set of 15 KVA to 250 KVA Capacity removing the alternator from foundations/ enclosure , transporting to workshop, dismantling completely including stator, rotor, removing burnt winding and replacing with new copper winding (copper winding shall be paid separately as per actual weight under item No. 3.01), insulation, unserviceable parts, bearing cleaning all the parts with thinner and varnishing completely with F class varnishing, applying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed. Note: The qty of copper winding replaced shall be measured in under mentioned item as supply only

2

-

-

... More
Supply only Copper winding of Alternator with insulation material

60

-

-

... More
M & L for replacement of defective spare parts of DG Sets of capacity 200KVA,Make : Kirloskar including dismantling old parts, fitting new part, connecting and testing all as specified and as directed.

-

-

-

... More
Air filter (inner & Outer)

1

-

-

... More
V Belt

1

-

-

... More
Water Pump assembly

1

-

-

... More
M & L for replacement of undermentioned UNSV/ defective spare parts of DG Sets of capacity 160 KVA, Make: Cummins / Kirloskar/ Mahindra or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed.

-

-

-

... More
Air filter

2

-

-

... More
V belt

2

-

-

... More
Water Pump assembly

1

-

-

... More
M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 125 KVA, Make :Kirlosker or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed.

-

-

-

... More
Air filter

2

-

-

... More
V Belt

2

-

-

... More
Water Pump Assembly

1

-

-

... More
M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 82.5 KVA, Make :Cromption Greaves or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed.

-

-

-

... More
Air Filter

1

-

-

... More
V Belt

2

-

-

... More
Solenoid switch

1

-

-

... More
M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 55 KVA/62.5 KVA/63 KVA, Make : Crompton Greaves or any other make existing at site including dismantling old part, connecting, asssembling new part and testing all as specified and as directed.

-

-

-

... More
Air filter

2

-

-

... More
V Belt

2

-

-

... More
Water Pump Assembly

1

-

-

... More
M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 15 KVA, Make: Crompton Greaves including connecting and testing all as specified and as directed.

-

-

-

... More
Air filter

1

-

-

... More
V Belt

1

-

-

... More
M & L for replacement of undermentioned defective spare parts of DG Sets of capacity 12.5 KVA,Model- S 3804 & NB 200M Make :Greaves including connecting and testing all as specified and as directed.

-

-

-

... More
Engine upper Gasket

1

-

-

... More
Air filter

1

-

-

... More
M&L for Oil Pressure gauge of DG set complete incl necessary connections & taking down/ out old UNSV complete.

1

-

-

... More
M&L for RPM gauge of DG set complete incl necessary connections & taking down/ out old UNSV complete.

1

-

-

... More
M&L for Analogue DC Amp meter cap 20 Amp of DG set complete incl necessary connections & taking down/ out old UNSV complete.

1

-

-

... More
M&L for Digital voltmeter suitable upto 415 volt of DG set complete incl necessary connections & taking down/ out old UNSV complete.

1

-

-

... More
M & L for replacement of defective spare parts of DG Sets of capacity 12.5 KVA,Make : Kirlosker including connecting and testing all as specified and as directed.

-

-

-

... More
Air filter

2

-

-

... More
Dismantling , removing the self starter 12 volt from the engine of DG Sets upto 200 KVA opening up, over hauling/ repairing/ servicing, replacement of defective undermentioned parts and assembling, refixing and testing for proper functioning :

2

-

-

... More
Carbon Brush

4

-

-

... More
Bendex/ Pinion

2

-

-

... More
Rewinding of Stator

2

-

-

... More
Carbon brush holder

4

-

-

... More
Dismantling , removing the self starter 24 volt from the engine of DG Sets from above 200 KVA to upto 400 KVA opening up , over hauling/ servicing, replacement of burnt winding, carbon brushes with holders assembling back, refixing and testing for proper function complete all as directed.

2

-

-

... More
M&L for solenoid switch 12 volt with relay for DG self starter 12 volt complete with connection plate all as specified & directed.

2

-

-

... More
M&L for solenoid switch 24 volt with relay for DG self starter 24 volt complete with connection plate all as specified & directed.

2

-

-

... More
Dismaintling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing/ descaling, removing blockages arresting leakages, assembling back incl necessary welding brazing as required, refixing , reconnecting and testing for proper functioning :

-

-

-

... More
25 KVA to 100 KVA

2

-

-

... More
125 KVA to 400 KVA

3

-

-

... More
Cleaning of fuel tank of DG set of following capacities by disconnecting fuel pipes connection, draining out fuel from the tank, cleaning of tank, replacement of chocked all fuel pipe Connection of suitable diameter, painting of fuel tank with synthetic enamel paint, one coat after cleaning, scrubbing the surfaces incl writing with paint the capacity, serviceability of fuel gauge complete for following DG Sets.

-

-

-

... More
12.5 KVA to 180 KVA

3

-

-

... More
200 KVA to 400 KVA

3

-

-

... More
M & L for painting of DG sets top frame and bottom frame, inner side base of capacity 7.5 KVA to 63 KVA with existing colour with spray painting including cleaning of rusted space of the body all as specified and directed by Engr-in-Charge

4

-

-

... More
M & L for painting of DG sets top frame and bottom frame, inner side base of capacity 100 KVA to 250 KVA with existing colour with spray painting including cleaning of rusted space & prepration of surfaces of the body all as specified and directed by Engr-in-Charge

4

-

-

... More
S & F in repair automatic voltage regulator of following capacity complete all as specified and as directed by Engr-in-Charge

-

-

-

... More
10 KVA to 125 KVA

2

-

-

... More
160 KVA to 400 KVA

2

-

-

... More
Replacement of coolant incl taking out old , Supply & Pour in refilliing of coolant, K cool Supper plus 50-50 Premix complete. Note: The net qty of coolant shall be measured for payment.

200

-

-

... More
Supply & Pour in refilliing of battery distilled water

150

-

-

... More
Replacement of Engine oil incl taking out old, Supply & fill in refilling of engine oil 15w40 superior quality engine oil complete.

650

-

-

... More
M & L for replacement of steel hinges of door of various capacity of DG Set 100 KVA to 400 KVA complete with nuts and bolts reqd/ welding as reqd at site.

40

-

-

... More
Replacement of Existing Acoustic enclosure of DG set 15 KVA complete by removing Alternator, Engine & all accessories, pipe, cable connections and fixing in new Acoustic enclosure with inbuilt fuel tank, exhaust siencer made of Powder coated CRCA sheet 16 gauge min having suitable ISMC channel for base and fixing of Engine & Alternator. Cenopy shall have the contractor shall check size of engine & alternator of existing DG Set at site. doors - 04 Nos with steel hinges, high quaity EDPN/ neoprene gasket, acoustic insulation material complete to comply CPCB norms of 75dBA at 1 Mtr and fuel, cable connections complete for satisfactory testing of DG set incl any type of T&P, hydra, T&P charges complete.

1

-

-

... More
Supply & Fix in repair SMPS based 12Volt/10 Amp float cum boost type battery charger suitable for input voltage 220 V and output voltage 12 Voltage having NO & NC terminals with necessary electric connections in DG control panel complete all as specified and dircted by engineer-in-charge.

3

-

-

... More
Supply & Fix in repair SMPS based 24Volt/20 Amp float cum boost type battery charger suitable for input voltage 220 V and output voltage 24 Voltage having NO & NC terminals with necessary electric connections in DG control panel complete all as specified and dircted by engineer-in-charge.

3

-

-

... More
M&L for Overload relay with range 3-5 Amp suitable for 3 phase connections complete all as specified & directed.

2

-

-

... More
M&L for Annuciator window suitable to work on 12/24Volt DC having button for reset, test, Acknowledge and features suitable for DG set faults 12 Nos minimum having required windows complete of size suitable to fit in existing panel complete all as specified & directed.

2

-

-

... More
Attending complaints of not working / any error / mechanical/ electrical/ electro-mechanical of DG sets/ AMF panel up to 400 KVA within 3 hours after intimation to the contractor by the Department. Complaint shall be attended by qualified mechanic all as specified and as directed by Engineer - in - charge. If contractor fail to attend the complaint of DG set within 3 hours, recovery @ Rs. 500/- per hour shall be imposed upon the contractor. Note: Major parts required to be replaced shall be measured and paid separately.

15

-

-

... More
M&L for battery terminals with nut & bolt heavy duty suitable for upto 180 Ah maint free DG set battery complete.

10

-

-

... More
Supply and fixing in repair battery 12 volts 150 AH maint free type complete all as specified and as directed by Engineer in Charge. Make : Exide Express or eqvt in TATA /AMARON

8

-

-

... More
Supply and fixing in repair battery 12 volts 180 AH maint free type complete all as specified Make : Exide Express or eqvt in TATA /AMARON

10

-

-

... More
Supply and fixing in repair battery Battery Lead of size 35 sqmm made of copper of superior quality having length 60 cm min complete.

10

-

-

... More
Supply & Fix in repair onload changeover switch with steel sheet enclosure 4 pole, 400 A, 415Volt 50 Hz all as specified and as directed by Engineer -in- charge.

1

-

-

... More
Supply and fixing in replacement 3 pole contactors 40 Amps with coil voltage 240 Volts. Make BCH or equivalent in Havells/C&S/Indo Asian/L&T/ Siemens/Schneider Note for item No. 40 to 44:- The new contractor, contractor coil shoul be of same model as per existing size to avoid any alteration/modification during replacement.

2

-

-

... More
Supply and fixing in replacement 4 pole contactor MCX 41 of make L&T, coil voltage 220/240/415 volts, 2 NO + 2 NC complete with spreader link kit as reqd at site complete all as directed by Engr-in-Charge. Make L&T or equivalent in Havells/C&S/Indo Asian/ Siemens/Schneider

1

-

-

... More
Supply and fixing in replacement 4 pole contactor MCX 44 of make L&T, coil voltage 220/240/415 volts, 2 NO +2 NC complete with spreader link kit as reqd at site complete all as directed by Engr-in-Charge. Make L&T or equivalent in Havells/C&S/Indo Asian/ Siemens/Schneider

1

-

-

... More
S&F Add on Aux contact block having 1 NO + 1NC suitable for MCX 34 to MCX 44 complete all as directed.

1

-

-

... More
S&F spare coil for contactor MCX 41 to MCX 44, coil voltage 240/415V as reqd at site complete.

1

-

-

... More
M&L for MCCB 200 Amp, 4 pole, 25kA complete with spreader link set and phase separator complete all as specified & directed. Make : L&T/ Schneider/ ABB/ BCH / C&S/ Siemens

2

-

-

... More
M&L for MCCB 250 Amp, 4 pole, 36kA complete with spreader link set and phase separator complete all as specified & directed. Make : L&T/ Schneider/ ABB/ BCH / C&S/ Siemens

1

-

-

... More
M&L for MCCB 315 Amp, 3 pole, 36kA complete with spreader link set and phase separator complete all as specified & directed. Make : L&T/ Schneider/ ABB/ BCH / C&S/ Siemens

1

-

-

... More
M&L for MCCB 400 Amp, 3 pole, 36kA complete with spreader link set and phase separator complete all as specified & directed. Make : L&T/ Schneider/ ABB/ BCH / C&S/ Siemens

1

-

-

... More
Supply and fix Voltage monitoring relay suitable having Single phase preventor, Under voltage & overvoltage feature and control to set voltage limits and digital display to show voltage and LEDs for fault indication complete all as specifed.

2

-

-

... More
Supply and fix Single phase preventor having voltage unbalance and phase reversal protection. Make GIC/L&T or other equivalent approved make.

4

-

-

... More
Supply and fix in replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter. Make L&T/ GIC/ Legrand/ C&S/Minilec or equivalent.

2

-

-

... More
Material and labour for fixing of MS CRCA sheet powder coated of 2 to 3.15mm thickness , cut to shape and size required as per LT panel located at site including welding of hinge joint to sheet for fixing complete all as per directed by Engineer-in-Charge. Note: The contractor shall have to take measurement of panel at site for new sheet complete.

160

-

-

... More
Supply and fixing of Micro Processor controller unit with RS 485, RS232 connector port, IP/OP serial connector able to work on 8 to 35V dc, having suitable ports for DC conn, AC suppply, alarms, auto start conforming to model No i.e. EC-RXA-V2 Make C&S / KG 545 of Kirloskar / DSE or any other updated make/ model matching with features of existing controller suitable for DG set of cap 7.5 kVA to 400 kVA make Kirloskar/ Cummins/ Mahindra/ CSH/ Greaves Cotton and necessary connections complete all as specified and as directed.

2

-

-

... More
Repair/ Servicing /replacement of old UNSV parts of DG Set 250 KVA, Make Mahindra & Mahindra by disconnecting, taking down following parts from the engine, machining to engine block to make surface smooth and of suitable size to match with liner complete and replacing the UNSV parts with new parts and it functional complete all as specified and as directed. Note: The parts shall be measured & paid separately.

1

-

-

... More
Cylinder liner

4

-

-

... More
Piston complete with pin

4

-

-

... More
Piston ring set

4

-

-

... More
Cylinder head gasket

1

-

-

... More
Joint kit complete

1

-

-

... More
'O' ring kit complete

1

-

-

... More
Connecting rod big end bearing

4

-

-

... More
Connecting rod bearing small end

4

-

-

... More
Valve inlet and exhaust

6

-

-

... More
Valve seat

12

-

-

... More
Material and labour for Earth continuity conductor or main earth lead fixed on wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to pole or any other indicated as required on ground for 25x3 mm aluminium strip complete all as specified and as directed.

30

-

-

... More
Inspection, maintenance and servicing of DG set 15 KVA Make: CSH / Ashok Leyland by Authorized service center for complete functioning/ testing of Alternator, Engine, Electric panel boars, AMF system by authorized service senter completely of Engine, Alternator, fuel pump, Electric panel board, complete DG Set for routine check ('B' check complete as per recommendations of DG set manufacturer for smooth functioning and carrying out maintenance by replacing following parts complete all as specified and as directed

1

-

-

... More
Inspection, maintenance and servicing of DG set 160 KVA Make: Greaves Cotton by authorized service center (M/s Imperial Generator & Electricals) or any other authorized service center of OEM completely of Engine, Alternator, fuel pump, Electric panel board, complete DG Set for routine check ('B' check complete as per Greaves manual) of DG set for smooth functioning and carrying out maintenance complete by replacing following parts as directed Note: In case contractor does not gets service done from service center as directed by deptt. Then, penalty of Rs 10000.00 per service per DG set will be levied on Contractor. No claim will be entertained on this account.

6

-

-

... More
Element Pre Fuel Filter

3

-

-

... More
Element Micro Fuel Filter

3

-

-

... More
Lub Oil Filter (232V12)

1

-

-

... More
Greaves Lub Oil

60

-

-

... More
Radiator Pre-mix Make: Greaves Note for Srl item No. 57.01 to 57.05 : The spare parts shall be purchased/ procured from OEM company or their auth servicing centre only.

15

-

-

... More
Inspection, maintenance and servicing of DG set 160 KVA Make: mahindra & mahindra by authorized service center (M/s Diesel Power Solutions ) completely of Engine, Alternator, fuel pump, Electric panel board, complete DG Set for routine check ('B' check complete as per OEM manual) of DG set for smooth functioning and carrying out maintenance complete by replacing following parts as directed. Note: In case contractor does not gets service done from service center as directed by deptt. Then, penalty of Rs 10000.00 per service per DG set will be levied on Contractor. No claim will be entertained on this account. The parts to be replaced shall be measured from following items:-

2

-

-

... More
Element Pre Fuel Filter

1

-

-

... More
Element Micro Fuel Filter

1

-

-

... More
Lub Oil Filter

1

-

-

... More
mahindra Lub Oil

20

-

-

... More
Radiator Pre-mix Make: Mahindra Note for Srl item No. 58.01 to 58.05 : The spare parts shall be purchased/ procured from OEM company or their auth servicing centre only. The contractor shall provoide the bill to deptt.

5

-

-

... More
Supply, installation and testing of AMF panel outdoor type Height 150 mm X width 900mm X Depth 550 mm suitable for DG set 200 KVA with factory made type weather proof, double door type vermin proof fully ventilated both side opening and fabricated out of 3.15 mm thick CRCA sheet and mounting channel having copper bus bar three phases and one neutral of suitable capacity, fixed on insulator by coloured heat shrinkable sleeves and housed in specified including powder coated internally externally the entire steel surfaces MS abgle iron frame made of 45X45X5mm height 80 cm, all the cover shall have fully locking arrangement. fully internally wired with suitable size of thimbles and internally wiring of suitable size all as specified and as directed, comprising with following parts :- (a) Under voltage relay 415V AC for main supply (b) Under voltage relay 415V AC for DG supply (c) AC meter 230 V, 2 NO+2 NC (d) Microprocessor controller of make C&S/ kirloskar (e) Control MCB SP 16A (f) Control MCB SP 6A  (g) Automatic battery charger 24V/12V having floot/boost option as reqd at site.  (h) LED indicating light for main and DG (j) LED indicating light for main battery charger  (k) Digital voltmeter (0-500V) with selector switch  (l) Digital Ammeter (0-500A) with selector switch with suitable CT  (m) DC Volt meter 15/30V (n) DC Ammeter 0-15A (o) Trickle/ Boost switch (p) Auto/ Manual switch

1

-

-

... More
(q) Plus button start & stop with element (r) Power contactor 300A 4 pole 415V for DG (s) Power contactor 300A 4 pole 415V for Main  (t) MCCB 315A 35KA, 4 pole for main and DG supply control  (u) Suitable Nos of Control Relay and Overload relay 2P/ 4pole, with reqd C/O of suitable current rating (v) Any other material required, but not mentioned will be included in the item rate

-

-

-

... More
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 32x6 mm as earthing strip by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth strip protected by 40mm dia GI light grade pipe (IS-1239), PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. (Note: The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner . (2) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.

10

-

-

... More
M&L for pin type/ din mounting type relay 4 pole, 12 Volt of 12 Amp rating with 2/ 4C/O complete

2

-

-

... More
Supply and fixing in replacement 3 pole contactors 95 Amps with coil voltage 240/415 Volts. Make BCH or equivalent in Havells/C&S/Indo Asian/L&T/ Siemens/Schneider

2

-

-

... More
S&F spare coil for contactor rating 95 Amp, coil voltage 240/415V as reqd at site complete.

1

-

-

... More
M&L for flexible steel braided fuel pipe having banjo nipple & matching bolt at both ends of length 0.50Mtr min complete

2

-

-

... More
M&L for Analogue DC Voltmeter cap 30 Volt for DG set complete incl necessary connections & taking down/ out old UNSV complete.

1

-

-

... More
M&L for self starter assembly 12 volt/ 24 volt complete with solenoid switch incl necessary connections complete.

1

-

-

... More
M& for DG set timing belt suitabe for DG set cap 55 kVA to 400 kVA complete incl setting of timing and taking out old UNSV belt complete.

1

-

-

... More
Supply and fixing in replacement 4 pole contactor MCX 33 of make L&T, coil voltage 220/240/415 volts, 2 NO + 2 NC complete with spreader link kit as reqd at site complete all as directed by Engr-in-Charge. Make L&T or equivalent in Havells/C&S/Indo Asian/ Siemens/Schneider/BCH. Legrand

1

-

-

... More
Material and labour for fixing of Aluminium bus bar of size 40x10 mm or any other suitable size cut to required shape, length and size having colour heat shrinkable sleeves as per existing panel at site and cover bus bar with colour sleeve as per site requirement and fixed to bus bar support with DMC/SMC insulator complete all as specified and as directed.

40

-

-

... More
Periodical maintenance of Fire alarm system installed at MAP 'G-1' pocket with 01 No Main Fire control panel (4 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter 01 No at Ground floor of each one block ) incl making system fully functional on commencement of work by deploying suitable Technician. Technician will clean, inspect, check the functionality, tight connections testing including carrying out repairs initial for Fire Alarm system having Intelligent addressable fire alarm system control Panel, control loop panel and flow chart based programmable RTU, Loop card, Main board, LCD display, Printer Panel, AC filter, Lead acid batteries, UPS, Multisensor, sounder, MCP, Heat detector, smoke detector, Manual Call Point, Repeater Panel, Zone monitor Module, Loop Isolator, Amplifier, connection wires, batteries and Loud speakers, annuciator system for the trouble free and efficient functioninig of the entire fire alarm system all as directed and as per Guideline as mentioned in Tender particular specifications. The parts to be replaced shall be measured and paid separately. Note: Major defective parts replaced shall be measured under Item S No 79 to 100. The quoted rate includes the cost of minor parts. A report regarding satisfactory functioning of system shall be submitted by the contractor on letter pad monthly basis all as directed by Engineer-in-Charge.

8

-

-

... More
All as per above item No 70 but for Fire alarm installed at MAP 'H' pocket with MA in Fire alarm control panel - 02 No (10 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower. and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter 01 No for one block each ) for complete H pocket complete.

8

-

-

... More
All as per above item No 70 but for Addressable Fire alarm system installed at MAP 'G-2' pocket with Main FIre alarm control panel - 01 No (18 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower. and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter 01 No for one block ) complete G-1 pocket ) complete.

8

-

-

... More
All as per above item No 70 but for Addressable Fire alarm system installed at MAP 'K' pocket with Main FIre alarm control panel - 01 No (14 Blocks of G+6 structure having Smoke detector - 02 Nos & Heat detector - 02 Nos, MCP - 01 No, FCM - 01 No, Hooter - 01 No at each floor of G+6 tower. and Repeater panel - 01 No with FCM - 01 No, FIM- 01 No, SMPS -01 No, hooter 01 No for one block ) for complete K pocket ) complete.

4

-

-

... More
Non Comprehensive maintenance of fire fighting system installed at MAP 'G-1' pocket (4 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) by deploying suitable Technicians. Technician will clean panels, inspect, check the functionality, including replacing of defective parts of Fire Hydrant system having valve, Terrace pump & motor, starters, pressure switch, air pressure tank, panel etc. for satisfactory functioning and carryout physical check by testing once in a month on a convenient day at the discretion of User/ Engr-in-Charge in their presence and a report to this extent shall be submitted by the contractor in letter pad and all as directed by Engineer-in-Charge. The technician will grease/ oiling of components, valve, yard hydrant landing valve, hose reel valve etc. Note : The parts to be replaced shall be measured and paid separately.

9

-

-

... More
All as per above item No 74 but for Fire fighting system installed at MAP 'G-2' pocket (18 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete.

9

-

-

... More
All as per above item No 74 but for Fire fighting system installed at MAP 'H' pocket (10 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete.

9

-

-

... More
All as per above item No 74 but for Fire fighting system installed at MAP 'K' pocket (14 Blocks of G+6 structure having hose reel connection at each floor) (Yard Hydrant, Air Pressure Tank and Terrace pump - 01 No with accessories for each block) complete.

4

-

-

... More
Note for Item No 70 to 77 :- (i) The contractor shall submit a maintenance schedule for the entire period of Contract. (ii) Skilled manpower - 1 No min (Technician) of company dealing with Fire Alarm System shall be employed for Item No 70 to 77. The team will remain present during 9 to 5 PM having experiance of 2 years and maintain record of functioning of all equipments fortnightly basis. Report of testing on printed prescribed letter pad of the firm will be submitted to GE office. (iii) The above item will cover round the clock (24 x 7) complaint booking onTelephone Nos to ensure complaints will be attended within 48 Hrs. In case the contractor fails to do so, a penalty of Rs. 250/- per complaint per day for the delayed period will be deducted from payment. (iv) Any breakdown (major or Minor) shall be attended to keep the fire alarm and fire fighting system in working condition. Minor spares i,e. Lubricants, greasing, cloth for cleaning required will be provided by the contractor to make system functional for which cost deemed to be included in the rate (except item No 78 to 126 ). The replacement of any parts (Major) shall be measured and paid under relevant items given from 78 to 126:-

-

-

-

... More
(v) The qty of MCP, detector, repeater is approx/ tentative. Same may vary at site. Contractor shall quote his rate accordingly. Nothing extra shall be admissible on this account. vi) Contractor shall engage a qualified technician 01 No/per day having experiance of fire alarm systems, fire fighting system for maint. (vi) Contractor should have MOU with company working in Fire Alarm system before quoting of tender and submit copy of MOU document before submitting his tender. If contractor fails to submit MoU with bid, the tender of that contractor will be rejected. (vii) The contractor shall visit the site and check condition of existing system. (viii) The rate quoted includes the cost of making existing defective FIre Alarm system fully functional within 30 days from commencement of work. The rate of which deemed to be included in the monthly maint quoted rates. Nothing extra shall be admissible on account of this. (ix) The technician will beck functioning of terrace pumps, wetriser/down cummer systems daily or tasks as diected by deptt and will mantain record & submit to deptt.

-

-

-

... More
Dismantling and Servicing of all multi sensor detector with heat/ smoke combination photoelectric as per exact locations with the help of manufacturer's instructions and testing for exact fault locations including cleaning through air blower then reinstalling complete all as specified and as directed.

360

-

-

... More
Supply and Fixing in replacement of addressable smoke detectors Addressable type multisensor detector with smoke and heat combination with base with self built intelligence all as specified and as directed. Make: GST/GST/ COOPER/BOSCH/SIEMENS/HONEYWELL/ competiable with existing system. Note for Item No. 79 to 100:- The new item to be fixed shall be completible with existing Fire Alarm & Fire Central System. Contractor shall quote his rate accordingly. Nothing extra shall be admissible on this account.

10

-

-

... More
Supply and Fixing in replacement of Indoor addressable heat detectors addressable type with suitable model base with fixed temperature 57 Degree approx complete matching to existing model FST-851 of NOTIFIER or superior model to match with site all as specified and as directed. Make: GST/GST/ COOPER/BOSCH/SIEMENS/HONEYWELL/ competiable with existing system.

45

-

-

... More
Supply and Fixing in replacement of Indoor addressable smoke detectors addressable type photoelectric with suitable model base, UL listed suitable for Op. Temp 49 degree C complete matching to model FSP-851 of Notifier or other existing model all as specified and as directed. Make: GST/GST/ COOPER/BOSCH/SIEMENS/HONEYWELL/ competiable with existing system.

45

-

-

... More
Supply and fix Addressable intelligent resettable type manual call point model No NFX-MCP-GLASS, EN54-11 TYPE A of NOTIFIER by Honeywell/compatible with existing system, with mounting base all as specified and as directed

80

-

-

... More
Supply and fix Fault Isolator Module Model No TC811A1006 of make HONEYWELL with mounting backbox complete all as specified and as directed. Make :SAFETEK/CIMCON/POWERTEK/competiable with existing system.

25

-

-

... More
Supply and fix Addressable electronic sounder cum Hooter Strobe having Audible and visual alert facility regulated by 24V DC of Model SYS-HS of SYSTEM SENSOR complete all as specified and as directed.

15

-

-

... More
Supply and fix in replacement Addressable fire control module including testing complete all as specified and as directed. Make: GST/COOPER/GODREJ/AGNI/HONEYWELL, competiable with existing system.

25

-

-

... More
Supply and fix in replacement Addressable fire Relay module including testing complete all as specified and as directed. Make: GST/COOPER/GODREJ/AGNI/HONEYWELL, competiable with existing system.

25

-

-

... More
Repair of existing Main Fire Control Panel NFS2-640./ Repeater /NCA Network Control Annuciator panel NFS2 3030 of NOTIFIER having remote control, annuciator functions complete incl dismanting and replacing the defective parts and assembling, incl data download/ storage before repair, software upgradation and data uploading and fixing at site for testing complete all as specified and as directed. The rate quoted includes cost of any minor parts not specified here. The major parts shall be measured as under following relevant items Make :CONNECTWELL/BRISK/ELMEX, competiable with existing system.

4

-

-

... More
Main CPU Board of Repeater panel

1

-

-

... More
Main CPU Board of Main Fire Control panel

2

-

-

... More
Notifier LCD-160 panel suitable for 640 character display (NCA-2)

1

-

-

... More
Base Card

2

-

-

... More
Notifier Fire Alarm Subassembly S635 card

1

-

-

... More
Loop card

1

-

-

... More
Supply and Fixing wall mounted loudspeaker 10 watt 230V AC ,50Hz of sturdy design weather proof type re-entrant horn type loudspeaker for operating under rough conditions complete all as specified and as directed. Make:-AHUJA/BOSCH/ HONEYWELL competiable with existing system.

8

-

-

... More
M&L for PA Amplifier with built-in Digital Player suitable for multi application confirming to model No SSA-5000DP of Ahuja or equivalent complete.

1

-

-

... More
M&L for Remote Paging Microphone of Make Ahuja Model No APM-201 RM complete all as directed.

2

-

-

... More
M&L for 6 Zone Paging Control unit/ Switcher of Model No APM -202CU of Ahuja Complete all as directed.

3

-

-

... More
S&F maintenance free Lead Acid battery 12 Volt, 7 Ah capacity complete all as specified and as directed. Make: EXIDE/ AMARON/ TATA

12

-

-

... More
S&F maintenance free Lead Acid battery 12 Volt, 12 Ah capacity complete all as specified and as directed. Make: EXIDE/ AMARON/ TATA

2

-

-

... More
M&L for UPS 650VA/ 360 W with input voltage 220-240V AC, Output 220V- 240V and DC input rating 12V DC, 30 Amp minimum complete.

2

-

-

... More
Supply, laying, installation, testing and commissioning of FRLS PVC insulated unsheathed copper conductor multistranded copper conductor cable of size 1.5 Sqmm, drawn through existing conduit, laid in trenches complete all as specified & directed.

1000

-

-

... More
Supply, laying, installation, testing and commissioning of PVC insulated , sheathed copper conductor armoured multistranded copper conductor cable of size 1.5 Sqmm, 2 core drawn through existing conduit, laid in trenches under load/floors, along well complete all as specified & directed.

1000

-

-

... More
M&L for DWC (double wall corrugated) HDPE pipe IS 16205 in suitable colour of size 40 mm OD complete all as specified & directed.

200

-

-

... More
M&L for repair to NCA-2 Primary display suitable for Honeywell Notifier panel complete with replacement of all defective parts complete incl taking down old UNSV and testing complete all as directed.

1

-

-

... More
M&L for SMPS AC-DC adaptor suitable for input power supply 140 to 280 volt and out put 24V DC, 5 Amp complete as directed.

10

-

-

... More
M&L for replacement of glass of Manual control point (MCP) complete incl dismantling MCP and refixing after replacement of glass incl connections tightning.

80

-

-

... More
Supply and fix Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 150mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed.

2

-

-

... More
Supply and fix Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 100mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed.

2

-

-

... More
Supply and fix Cast Iron Non return butterfly valve class PN 1.6 flanged ends suitable for 80mm bore CI / DI pipe including all joints with rubber or fibre board gasket , bolts and nuts, washer complete all as specified and as directed.

2

-

-

... More
Supply & fix Cast Iron Butterfly valve having drilled end suitable for 150 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed.

3

-

-

... More
Supply & fix Cast Iron Butterfly valve having drilled end suitable for 100 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed.

3

-

-

... More
Supply & fix Cast Iron Butterfly valve having drilled end suitable for 80 mm bore, ISI marked including all joints with rubber or fibre board gasket, bolts and nuts, washer complete all as specified and as directed.

3

-

-

... More
Supply and fix ball valve of size 50mm dia bore incl all required fittings complete all as specified and as directed.

1

-

-

... More
Supply and fix ball valve of size 25mm dia bore incl all required fittings complete all as specified and as directed.

3

-

-

... More
Supply and fix ball valve of size 20mm dia bore incl all required fittings complete all as specified and as directed.

4

-

-

... More
Supply and fixing 63mm dia 15m long CP hose confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and as directed.

3

-

-

... More
Supply and fixing 20mm dia 30m long hose reel confirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and as directed.

3

-

-

... More
Supply and fix fire hydrant landing valve type A (SINGLE HEAD OUTLET) of 63mm dia conforming to IS :5290 including rubber or fibre gasket, bolts and nuts complete all as specified and as directed.

3

-

-

... More
Supply and fixing 63mm dia gun metal branch pipe with instantaneous inlet with threaded type outlet and 15 mm short nozzle conforming to IS 903 complete all as specified and as directed.

2

-

-

... More
Supply & install Pressure guage 4" dial 0 - 14 Kgs rating complete all as specified and as directed.

8

-

-

... More
Supply & install Dual Pressure switch Universal type having min Range upto 7.5 Bar and differential scale complete all as specified and as directed.

4

-

-

... More
M & L for removing motor pump assy 15HP, 3 phase, 50 Hz of Terrace Fire pump installed at (G+6) block by disconnecting electric connections and discharge pipe and trasporting the same to workshop for opening, dismanting and cutting of old burnt winding wire of motor and rewinding of motor with coppper winding wire as per existing size, replacement of Insulation material, oil/ water seal, ball bearing, change of oil seal and making necessary connections with existing copper lead with sleeves from motor to connection plate, cleaning of impeller housing, greasing to all moving parts, bearing and reassembling the motor, Shifting to site back, making joints, electric connection and refitting with the help of tripod/any other machinery such as hydra, connecting, commissioning and testing on full load complete including replacement of worn out nut bolts or any minor parts required to make motor pump assy serviceable all as specified and as directed by Engineer - in - charge.

4

-

-

... More
Material and labour for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE LT underground power cables of the rating 1.1 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of fault location necessary excavation upto 10m length and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar Cantt all as specified and as directed. Notes : (a) The joint shall be measured and paid separately under relevant item. (b) The qty of item will be executed at different times during currency of contract as directed by Engineer-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly. (c) Fault should be detected and rectified within 12 hrs from intimation to contractor. the penalty should be levied to contractor at the rate of Rs. 500/- per hours, if contractor fails to restore supply or contractor has to make temporary alternate arrangement for restoration of electric supply at his own cost.

7

-

-

... More
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 150 to 240 sqmm 3.5 core complete all as specified and as directed.

4

-

-

... More
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 185 Sqmm, 3.5 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall under roads complete all as specified and as directed

250

-

-

... More
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 240 Sqmm, 3.5 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall under roads complete all as specified and as directed

120

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed by Engr-in-charge.

50

-

-

... More
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and trenches punned down to thickness of 18 cm complete all as specified and as directed.(Note: Punned thickness of 18 cm will be measured and paid)

35

-

-

... More
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and as directed by Engineer-in-charge.

5

-

-

... More
Supply, fix and jointing heavy grade MS ERW pipe 80 mm bore heavy grade, laid in trenches / under floors or fixed to wall including all fittings, such as coupling, bends, elbow, and tee etc, with welded joint all as specified and as directed.

6

-

-

... More
Material and labour for Boring hole under the road/ pavement/ hard standing and inserting HDPE pipe of 100mm at a depth not less than one metre below ground level complete all as specified & directed. Note: The quoted rate includes cost of HDPE pipe 100mm pipe min.

25

-

-

... More
M& L for Cutting chases in road/ hardstanding upto depth of 150 mm min holes in or through walls /earth surface for in and including inserting GI/HDPE Pipe up to 100mm bore mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. (Note: The quoted rate includes GI/HDPE pipe.)

10

-

-

... More
Supply and fixing in replacement 3 pole contactors 12 Amps with coil voltage 240 Volts, 2NO + 2NC, model MO-12 of L&T or equivalent in Havells/C&S/BCH/Indo Asian/L&T/ Siemens/Schneider

3

-

-

... More
M&L for thermal overload relay, 3 pole, range 8.5 to 12.5 A, with NO + NC contacts confirming to model RTO-1 of L&T or equivalent in C&S/ BCH/ Schneider/ Siemens/ BCH

3

-

-

... More
Supply and fixing in replacement MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer including dismantling/ taking down existing MS work complete all as specified and as directed. Note: Unexposed surface shall be given one coat of primer only.

0.5

-

-

... More
M & L for repair to OCEMS incl iRTU controller complete by replacement of iRTU 1000 controller and RS-232 to RS-485 controller complete for satisfactory fucntioning of OCEMS and data shifting to PPCB server complete.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.