Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date10 Jun 2020
Closing Date21 Jul 2020
Tender Amount₹ 16,26,598 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12mm veneered particle board with commercial veneering on both faceS ,The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated, fitted to chowkhats incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.

10.56

-

-

... More
M&L for 35mm thick glazed and skeleton shutters (Factory made) of 2nd class hard wood and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.20 (a) of SSR Part-I 2009 (Larger size to be provided) incl 02 coats of synthetic enamel paint over a coat of pink primer after preparation of surfaces complete all as specified and directed.

10.56

-

-

... More
M&L for Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick M S sheet tube factory made with double side hung wire gauged shutter & glass/glazed shutter (wire cloth and glass panes only shall be measured and paid separately) with steel handle and steel peg stay dovetailed or welded incl 2 Nos. tower bolts 150mm long for each leaf and 10mm square bar grills at spacing as shown on drg, welded to F I frame work, including other fittings; hinges, handles, tarred hold fasts fixed in PCC blocks all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.

32

-

-

... More
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all specified and as directed by Engr-in-Charge.

390

-

-

... More
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. (Note : The colour of sheet shall be as approved by GE)

426

-

-

... More
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof ridge/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. (Note : The colour of sheet shall be as approved by GE)

30

-

-

... More
M&L for False ceiling of 9.5mm thick gypsum tiles (of size 600x600mm) laminated with PVC film on the face side & metalised polyester film on the back side with all four edges sealed with PVC film (shade either plain white or crack) in a grid size of 605x605mm from manufacturer M/s Saint Gobain or equivalent of Armstong/Everest including taking down existing ceiling board of any type/pattern with GI frame work with grid size of 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.5 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI Hangers 4 mm dia (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40mm x3 mm size 60mm long and expansion hold fasteners 12.5mm ida, 40mm long incl taking down existing grid complete all as specified. complete all as specified and directed. Note :- Invoice from company’s authorized dealer shall be submitted with material by the contractor along with dealership certificate. Certificate of genuineness from the manufacturer shall also be submitted by the contractor before getting the material passed from the department.

300

-

-

... More
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, orstainless steel wire staples complete all as specified and directed.

29

-

-

... More
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty or fixed with beads/ glazing pins not .exc 0.5sqm in each pane complete all as specified and directed.

20

-

-

... More
M & L for Extruded aluminium alloy of size 150mm handles, fabricated type, anodised etc complete all as specified and directed.

24

-

-

... More
M&L for 300mm aluminium sliding door bolt with hasp & staple (bolt type) and fixing clip of sheets cast or extruded section and fixing sliding bolt of extruded section etc complete all as specified and directed.

6

-

-

... More
M&L for aluminium anodized barrel tower bolts 200 mm of extruded section and fixed. complete all as specified and directed.

24

-

-

... More
M&L for 300 mm MS Rat tail door spring for door closer, complete all as specified and directed.

6

-

-

... More
S&F Aluminium Wardrobe hooks (single) 50mm to 60mm long and fixed with screws, complete all as specified and directed.

45

-

-

... More
M&L for Brick work with Fly Ash Brick (Non-Modular) Class 7.5, straight or curved on plan exceeding 6m mean radius built in CM (1:6) including demolition of existing brick works complete all as specified and directed.

44

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors & paving not exceeding 15 Cms thickness (beloe or above ground level ) complete all as specified and directed.

34.25

-

-

... More
S&F for 600mm x450mm looking mirror of selected quality glass mounted on 6mm thick AC Building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws & cup whashers complete all as specified and directed.

12

-

-

... More
Taking down cement plaster on brick or stone walls,etc including racking out joints , hacjking for keys,scrubing down with water etc, and removal of rubbish out off the permises complete all as specified.

550

-

-

... More
M&L for rendering 10mm thick on brick work or concrete surface in CM (1:6) on wall surfaces finished even and smooth without using extra cement including preparation of new plastered surfaces of wall & applying two coats of distemper oil emulsion (OBD) over a coat of primer as per manufacturer instructions (from same manufacturer of OBD) over and including a layer of wall care putty 2mm thick complete all as specified and directed. complete all as specified and directed.

600

-

-

... More
M&L for Rendering 15mm thick in two layers [base layer 10mm IN CM 1:6 & finishing layer 5mm thick in cement mortar (1:4)] using liquid water proofing compound in IInd layer only on brick work or concrete surfaces of wall, surfaces finished even and smooth using extra cement complete all as specified & directed. (Note : WPC shall be measured and paid separately)

340

-

-

... More
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in coping, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed finished the surface even and smooth without using extra cement complete all as specified and directed.

3

-

-

... More
M& L mirror polish Machine cut kota stone slab in flooring 18-20mm thick over and including cement screed base 20mm thick backing coat of cement mortar (1 :4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 25 mm thick floor in PCC 1:2:4 type B-1(20mm graded crused stone aggregate) as in sub base for flooringcomplete all as specified and directed. (Note:- The rates of kota stone flooring includes for all cutting and waste including machine cutting to make it square or rectangular)

400

-

-

... More
M& L Machine cut mirror polished kota stone slab flooring 18-20mm thick as in riser/dado over and including cement screed base 10mm thick backing coat of cement mortar (1 :3) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. (Note:- The rates of kota stone flooring includes for all cutting and waste including machine cutting to make it square or rectangular).

30

-

-

... More
M&L for 60mm thick factory made rubberised coloured (laminated) interlocking paver block (using vibro compaction method) (topping thickness not less than 5mm) in white cement and non fadable glossy pigment of approved shade of any shape and size conforming to IS-15658-2006 of M-35 grade over and including 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) complete all as specified and directed.

60

-

-

... More
M&L for 75mm thick PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) as in plinth protection laid in panels and joints filled with mix of bitumen 85/25 grade and sand (1:2) by weight, finished the surface even and smooth without using extra cement etc complete all as specified and directed.

75

-

-

... More
M & L for sand filling under floors or in foundation including watering and consolidation as required on the site complete all as specified and directed by the Engr-in-Charge.

2.4

-

-

... More
Dismantling of existing framed trusses of Span not exc 10 m (Steel work in tubular trusses) and refixing of trusses on the base plate anchor with holding down screw including two coats of synethic enamel paint after prepartion etc. complete all as specified and directed.

12

-

-

... More
Dismantling of structural steel work (rolled mild steel work) including framed truss as in tubular purlins, rafter etc including refixing of tubular purlins, rafter on trusses with nessasary cleats including two coats of synethic enamel paint after prepartion on complete structural steel work complete all as specified and directed.

2600

-

-

... More
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS.1161 grade St.-240 including two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.

625

-

-

... More
M&L for G.I., round flat washers for 16mm bolts or screws complete all as specified and directed.

0.6

-

-

... More
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 45.0cm long & 16 mm diameter of neck complete all as specified and directed.

80

-

-

... More
M&L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe 410 -W (Gde- E- 250) quality - A complete all as specified and directed.

200

-

-

... More
S&F in repair for 25mm bore anodised aluminium alloy, single curtain rod (wall thickness not less than 1mm) including fancy type PVC brackets of approved design/pattern, funnels etc suitable for single curtain rod complete all as specified and approved by GE.

50

-

-

... More
M&L for Hard core, Broken stone aggregate to gauge n exc 63 mm as in plinth protection / sub bases etc deposited , spreaded and levelled in layers not exceeding 15 cm thick well watered and rammered to true surface complete all as specified and directed.

9

-

-

... More
M&L for Floor door stopper of aluminium alloy body and tongue with Overall length of cover plate 150mm, anodised, with hard drawn steel spring,fixed in floor complete all as specified and directed.

6

-

-

... More
M&L for Rolled sections as in framing FOR COOLER STAND for cladding, glazing and the like fixed with angle cleats and connecting plates, etc conforming to Fe 410 -W (Gde- E- 250) quality - A, complete all as specified & directed.

350

-

-

... More
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.

390

-

-

... More
M&L for Mild steel TMT bars 05 mm to 8mm dia , cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in striupps complete all as specified and directed.

220

-

-

... More
M&L for providing reinforced cement concrete (1:1.5:3) type A-1 (using 20mm graded crushed stone aggregate) in landings, cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc, set in cement morter (1:4) (of any section indicated) with plain fair faces, including chamfers, weatherings, throating etc and setting in mortar complete with joints to match complete all as specified & directed. (Note : Reinforcement shall be measured and paid separately)

5

-

-

... More
Taking down carefully unserviciable/ damaged copper/aluminium surface (batten/coduit or casing caping) point wiring any length for light/fan/socket or power including unscrewing from board (fitting and fixture such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sockets, Bracket /sketch fitting etc ) and removing material from site and making good to the disturbed surface to match with existing finish complete all as specified and directed.

138

-

-

... More
M&L for Modular Point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken modular metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point controlled by one way switch , SP, 6 Amps complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)

84

-

-

... More
All as per Srl item No. 44 above but for one multipin socket (5 pin) controlled by one switch, single pole, 5 Amp, 240 volts on the same board etc complete all as specified and directed.

12

-

-

... More
All as per Srl item No. 44 above but for one multipin socket (5 pin) controlled by one switch, single pole, 5 Amp, 240 volts on independent board etc complete all as specified and directed.

30

-

-

... More
M&L for Modular point wiring using FRLS PVC insulated unsheathed /multi stranded copper conductor cable 2.5 sqmm including 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor earth wire drawn through and including concealed PVC conduit of appropriate size not less than 20 mm dia and 1.8 mm thick including all fittings viz tees, bends, junctions box and approved make sunken metal flush gang box and suitable support frame and cover plate (inner/outer) of required modules for mounting modular switches/ sockets etc, for one 6 pin socket outlet 15 amps, Modular multi purpose independent point controlled by 15 Amp switch Single pole , one way , 240 volts l connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing including connection of cable with MCBs or bus bar shall be done through proper size copper/brass thimble of pin/u type etc (conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible), for light/fan/bell point complete all as specified and directed. (Note : Modular switch/bell push/fan regulator etc shall be measured and paid separately under respective items.)

12

-

-

... More
S & F modular switch piano type flush button one way, single pole 5 Amp one module complete all as specified and directed. Make : Legrand Cat Part No 673000/Crabtree Cat Part No ACMSXXW101/Anchor Roma Cat Part No 66111.

126

-

-

... More
S&F Modular Socket outlet, 5 pin, multi purpose 2 module 6 Amps, AC 230 volts, etc complete all as specified and directed. Make : Crabtree (Verona) Cat Part No : ACVKSWW065 or equivalent of Legrand/Siemens/Schenider/Anchor Roma.

42

-

-

... More
S&F modular switch Socket outlet, 2 in 1, 6 pin, ,5/15 Amps, flush type (ISI Marked ) AC 230 volts, etc complete all as specified and directed. Make : Crabtree /Legrand / Schneider /Siemens/Anchor Roma

12

-

-

... More
S&F modular Switch piano flush button single pole one way 16 Amp (ISI Marked ) AC 230 volts, front opreated etc complete all as specified and directed. Make : Crabtree /Legrand / Schneider /Siemens/Anchor Roma

12

-

-

... More
S&F Ceiling rose polycarbonate isolated body surface Bakelite, not less than 65 x 50 mm, three terminals, AC 230 volts etc, complete all as specified and directed. Make : Havells Cat Part No Reo/Cona Cat Part No 9246/GM Cat Part No 8224

57

-

-

... More
S&F Lamp holder insulated body with back plate suitable for batten fitting including 14W LED lamp of approved make and cat part and PVC Round/Square block etc complete all as specifeid and directed.

18

-

-

... More
S & F Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 100W- 2 module including necessary connections complete all as specified and directed. Make : Legrand Cat Part No 673028/Crabtree Cat Part No ACARFHW005/Anchor Roma Cat Part No 66502.

15

-

-

... More
S &F in replacement the Bulk head light fitting LED type 10 watt complete with 10 watt LED and having IP-63 protection and fixing on wall/ceiling complete with all accessories and including connecting up with ceiling rose with & including PVC insulated and overall sheathed flexible copper conductor cable and including 3 core 0.50 Sqmm complete all as specified and directed.

9

-

-

... More
S &F as in repair white powder coated CRCA box type with decorative end cap batten alongwith LED T8 tubular lamp of 20 Watts linear with extruded aluminium / PC body and PC diffuser and in bult driver, 230 Volts wall mounted completed with all accessories internally prewired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.Notes for Srl Item Nos 53, 55 & 56 :- 1. Driver shall be potted antivibration type. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be povided. 3. CRI (Colou Rendring Index) of fixture shall be 70. 4. CCT (Colout Correlated Temprature of fixture shall be 5700K ± 300 K. 5. System Lumen Efficacy shall be 100Lm/W 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years gurantee shall be provided by contractor suppoted by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the Contractor shall replace / repair the defective fitting within 07 Days after handing over to Contractor for replacement / repair 11. CA No shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintaince required, if any can be carried out from Top cover.

42

-

-

... More
S&F for MCB single pole (SP) 240 volts, 6 to 32 Amps, 10KA (C-series) , complete all as specified and directed.

24

-

-

... More
S&F for MCB single pole neutral (SPN) 240 volts, 40 to 63 Amps, 10KA (C-series) complete all as specified and directed.

3

-

-

... More
Taking down including refixing of ceiling fan of any sweep & size and refix in same position after overhauling including minor repairs by replacement of capacitor, safety pin, cap, nuts & bolts etc and making connection using 3 core, 0.50 Sqmm PVC insulated and overall sheathed flexible copper conductor cable from ceiling rose to fan, including testing to ensure efficient functioning including application of one coat of synthetic enamel paint by spray painting & rewriting number complete all as specified and directed.

10

-

-

... More
S&F Double door MCB DB SPN, 240 Volts, 12 Way made out of 18 SWG CRCA powder coated sheets, (IP43 protection) (phosphates powder coated with copper bus bar), earth stud, din rail, polyamid terminal blocks for incoming and outgoing circuits, inbuilt loose wire box, ground terminal blocks, duly prewired with thimble flame retardent copper conductors and polylayer for protection including one MCB, SP, 240 volts including taking out old unsv DB any size/type, complete all as specified and directed. Make: Legrand or equivalent in performance in other makes L&T/Hager/SCHNEIDER

3

-

-

... More
Supply , laying, testing and commissioning for 1100 volt grade XLPE insulated heavy duty cable, 16 sqmm 2 core, strip armoured with aluminium stranded conductor overall PVC sheathed laid in trenches including taking down existing cable & bricks complete all as specified and directed. Note : Excavation & Earthwork shall be measured and paid separately.

80

-

-

... More
M & L for well burnt bricks , laid flat ( old size) sub class B designation 75 for cable protection complete all as specifed and directed.

0.25

-

-

... More
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.

8

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.

4.5

-

-

... More
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.

3.5

-

-

... More
M&L for Sand filling in trenches dry and clean sand unwashed including punning around cable for protection of under ground cable duly compected and rammed with a layer of sand of 8 cm depth for the purpose of cushioning.and after laying cable the same shall be covered with sand to a depth of 15 cm (with overall 23cm of depth of sand cushioning punned down to 18cm) complete all as specified & directed. Note : Punned thickness shall be measured and paid accordingly]

2.5

-

-

... More
S&F for GI tubing 40 mm bore light grade laid in trenches/floors/ fixed to wall/poles for protection of cable with necessary fittings and FI clamps duly painted complete all as specified and directed.

18

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, HDPE pipe 15mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as directed. Notes: 1. Earth lead & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels .

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.