Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date27 Sep 2024
Closing Date25 Oct 2024
Tender Amount₹ 44,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling/taking down cross arms, bracings, support, clamp including nuts, bolts and washers complete.

1.5

-

-

... More
Dismantling of insulators LT of any size for removal or refixing at site as directed.

175

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm , 3.5 core. Make : KEI/Havells/Polycab

1295

-

-

... More
do-- but size 25 sq mm 3½ core

2745

-

-

... More
do-- but size 16 sq mm 4 core

1625

-

-

... More
Supply, install, testing and commissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCA sheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portions shall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted on plateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm from the ground level. The panel shall be provided with separate compartment of each switch gears with hinged door, including inter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (300 Amp) rated high conductivity Aluminum bus bar supported with DMC/ AMC barriers and colour cotted heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustration such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (200 AMP) and outgoing as per rating of MCCBs including aluminium lugs to connected the cable etc. Note:- 1. Design/ drawing / BOM of the panel board showing the dimension incl accessories is to be obtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. i). INCOMING: a) MCCB 200 A,415 Volts 4 pole, 36 KA-(Adj Thermal Mag sett)-01 (Incoming)+ 01 Nos spare b) Indicator lamp LED type (set of three Red,Yellow,Blue)-01 set ii) OUTGOING c) MCCB-63A,3 Pole ,25 KA -10 Nos d) Aluminum bus bar 300 Amp, reqd length-04 nos e) Digital Volt meter & Ammeter with suitable CT's each (f)Astronomical time switch complete with all accessories in built panel

1

-

-

... More
Supply, install, testing and commissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCA sheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portions shall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted on plateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm from the ground level. The panel shall be provided with separate compartment of each switch gears with hinged door, including inter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (300 Amp) rated high conductivity Aluminum bus bar supported with DMC/ AMC barriers and colour cotted heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustraction such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (200 AMP) and outgoing as per rating of MCCBs including aluminium legs to connected the cable etc. Note:- 1. Design/ drawing / BOM of the panel board showing the dimension incl accessories is to be obtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. a) MCCB 200 A,415 Volts 4 pole, 36 KA-(Adj Thermal Mag sett)-01 No b) Indicator lamp LED type (set of three Red,Yellow,Blue) ii) OUTGOING c) MCCB-4P-63A-10 - with 01 NOs spare d) Aluminum bus bar 300 Amp, reqd length-04 nos e) Digital Volt meter & Ammeter with suitable CT's each ( 500+400)

1

-

-

... More
Supply, install, testing and commissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCA sheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portions shall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted on plateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm from the ground level. The panel shall be provided with separate compartment of each switch gears with hinged door, including inter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (250 Amp) rated high conductivity Aluminium bus bar supported with DMC/ AMC barriers and colour cotted heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustraction such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (160 AMP) and outgoing as per rating of MCCBs including aluminium legs to connected the cable etc. Note:- 1. Design/ drawing / BOM of the panel board showing the dimension incl accessories is to be obtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. i). INCOMING: a) MCCB 160 A,415 Volts 4 pole, 36 KA-(Adj Thermal Mag sett)-01 Nos b) Indicator lamp LED type (set of three Red,Yellow,Blue) ii) OUTGOING b) MCCB-3P-63A- 09 NOs k) Aluminum bus bar 250 Amp, reqd length-04 nos l) Digital Volt meter & Ammeter with suitable CT's each

1

-

-

... More
M & L for preparation of old painted surfaces of LT panel size 2.0x1.5mx0.6m and applying spray painting with two coats of synthetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards complete all as directed by Engineer-in-charge including white wash to panel foundation/PCC base complete all as specified and directed.

1

-

-

... More
Material and labour for removing serviceable cable duly testing the cable by the megger and taking down existing serviceable and relaying as specified such as relaying/rerouting and shifting the cable to laying as reqd at site complete all as specified and directed Note: 1. Taking down removal of the cable rates deemed to include in quoted rates. 2. Excavation,earth work and other necessary items for the relaying of the cable measured and paid separately under relevent items

120

-

-

... More
M&L for removing bricks from trench for re use of serviceable bricks and re-laying old serviceable bricks of any type and size bricks, for cable protection in trenches laid dry and flat complete all as specified and directed by Engineer-in-Charge

90

-

-

... More
M&L for taking down carefully street light fitting and bracket for re use to servicebile after minor repairs if any by replacing wire, connection terminals and nut, bolt washers and fix the street light and bracket with steel tubular pole by using necessary clamps,nut bolts and washers complete all as specified and directed. Note: Clamps,nut,bolt and washers for fixing street light bracket is measured and paid seprately with relevent items of the schedule

28

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 10 to 50 sqmm,Indoor/Outdoor type

6

-

-

... More
M&L in repairs for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 70 to 150 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge

8

-

-

... More
S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection of street light from FRP junction box to street lights including provision of flexible pipe to conealed the copper wire from weather expose complete all as specified and directed by Engineer-in-Charge

165

-

-

... More
M&L for Earthing for Panels complete with galvanized steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized iron earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.

6

-

-

... More
Supply and install steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) with MS base plate of size 300 X 300 X 6 mm thick at bottom , welded at center with through hole of 14 mm dia height of 300 mm above the coping, complete with including painting of poles with two coats of synthetic enamel paint over a coat of primer black and white/yellow strips 30CM wide each (05 Nos) up to 1.5 Mtrs height from coping & numbering of poles complete all as specified and directed. all as directed.

28

-

-

... More
M&L for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggrigate for foundation of pole etc complete all as specified.

1.51

-

-

... More
M&L for providing PCC 1 : 3: 6 type C2 using 40mm graded stone aggregate as foundations, filling and mass concrete complete all as specified and directed

15.37

-

-

... More
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggrigate in coping or chamfered on edges complete all as specified.

2.2

-

-

... More
Supply and fix in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified. Make-Neptune/Hensel/Sintex

26

-

-

... More
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as specified.

1

-

-

... More
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed.

62

-

-

... More
Excavation in trenches any type of soil , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specificed and directed.

710.6

-

-

... More
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc. 25 cm within the 1 mtr strech complete all as specificed and directed.

361.6

-

-

... More
Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specificed and directed.

346

-

-

... More
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.

304.4

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology usingn ultra sound technique and necessary machine including HDPE/GI pipe of 100 mm dia suitable for 0.4 mpa working pressure

80

-

-

... More
M&L Supplying and laying reinforced precast concrete cable cover, class LV, type 1with peak, size 250mm x 150mm x 40mm®

26433.33

-

-

... More
M&L for Earthing for Pole /DB complete with galvanized steel plate electrode of size 600x600x6.3mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanized iron earth strip of size 4mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed.

8

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make :Crompton ,cat part NO : CRP-409-60-57-SL-GL-NSG or equivalent in Bajaj/ Philips.

12

-

-

... More
M&L for street light bracket made to shape from 40mm dia length 1.5m GI Pipe medium grade incl two number of clamps made from 50 x 6 Flat iron nut bolts complete all as directed

28

-

-

... More
S & F LED flood light 60 watt 230 V AC ,made out of pressure die cast Aluminium housing with toughned glass and high power LEDs secondary optics with IP-66 protection system efficacy 110/120 LPW.

5

-

-

... More
S & F ,4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 35 KA for existing serviceable source panel

1

-

-

... More
S & F 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 35 KA for existing serviceable source panel

1

-

-

... More
M& L for disconnecting cables and earthing strip carefully of existing 1100 V Old seviceable panel and shifted to where directed and reinstalled , testing & commisining the same complete all as specified . note: cost of shifting by veh deemed to be included in qouted rates.

1

-

-

... More
Dismantling and taking DBs of any size including breaking of PCC foundation and earth work etc and removal of debris where directed complete.

7

-

-

... More
Dismantling of old UNSV earthing

6

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core including provision of LT cable path indicator CI round shape mentioning LT cable of Blue color paint fixed with 0.75 Mtr lenth angle iron of size 40x40x4 mm laying intervals 20 Mtr and refer laying of cable shall be compile with SSR Part -I Section 19.75.1 Note: Cable path indicators and end termination joints with aluminium lugs/thimbles deemed to include with quoted rates

350

-

-

... More
do-- but size 35 sq mm 3½ core

275

-

-

... More
Supply, install, testing and commissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.25 X 1.8 X 0.6 mtr shall be made 3.15 mm thick CRCA sheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portions shall be powder coated both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted on plateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm. The panel shall be provided with separate compartment of each switch gears with hinged door, including inter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (400Amp) rated high conductivity Aluminum ( double set -08 NOs ie one set for Main supply incomming only , another set for change over incomming) bus bar supported with DMC/ AMC barriers and colour cotted heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustration such as LED phase indicating lamps and CTs including external aluminium strip and rating of MCCBs including aluminium lugs to connected the cable etc. Note:- 1. Design/ drawing / BOM of the panel board showing the dimension incl accessories is to be obtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. i). INCOMING: a) Change over Switch with MCCB 250 A,415 Volts 4 pole, -(Adj Thermal Mag sett) b MCCB 250 A,415 Volts 4 pole, -(Adj Thermal Mag sett) c) Indicator lamp LED type (set of three Red,Yellow,Blue) ii) OUTGOING d) MCCB 100 A,415 Volts 4 pole (03) e) MCCB 63 A,415 Volts 4 pole (05) f) MCCB 40 A,415 Volts 4 pole 25 KA,(04) g) Aluminum bus bar 400 Amp , Reqd length -08 nos h) Digital Volt meter & Ammeter with suitable CT's each (500+400)

1

-

-

... More
M&L in repairs for straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 16 to 50 Sqmm 3.5 Core complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat.

0.3

-

-

... More
M&L for 75 mm dia HDPE pipes PN 10 with fittings, laid in trenches/wall for protection of underground cable when crossing the road/fixing on wall.

10

-

-

... More
M&L for 50 mm dia HDPE pipes PN 10 with fittings, laid in trenches/wall for protection of underground cable when crossing the road/fixing on wall.

12

-

-

... More
S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 12 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed.

3

-

-

... More
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells

4

-

-

... More
M&L for submain wiring comprising single core ,2 Runs of 4 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in surface/recessed PVC conduit and its fittings complete including provision of 1X 4 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engr-In-charge. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)

120

-

-

... More
M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. in surface/recessed PVC conduit and its fittings complete including provision of 1X 4 sqmm nominal cross sectional area multi stranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main complete all as specified and directed by Engr-In-charge. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)

110

-

-

... More
Supplied and fixed Miniature circuit breaker (MCB) single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as directed by Engr-in-charge.

12

-

-

... More
Supplied and fixed MCB, Double pole, 240 Volts, of 6-32 amps current rating of 10 KA complete all as directed by Engr-in-charge.

2

-

-

... More
S&F Steel pregalvanized hot dip GI cable tray said thickness 1.6 to 2.0 mm size 50 mm to 350 mm, pre galvanized coating, rectangular shape, ARS brand complete all as specified and directed.

231

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.