Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Military Engineer Services - MES Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date10 Jul 2024
Closing Date4 Sep 2024
Tender Amount₹ 34,00,000
Costs
EMD
₹ 68,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665072_1Bid Award Id
ViewTender No
GE KPT - /2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Certain misc repair to drain, fencing, gates, pathway, boundary wall etc and Repairs/Replacement and cleaning of manholes, septic tanks and sewage line at New Mil Stn Kapurthala under GE Kapurthala.
Certain misc repair to drain, fencing, gates, pathway, boundary wall etc and Repairs/Replacement and cleaning of manholes, septic tanks and sewage line at New Mil Stn Kapurthala under GE Kapurthala.
Certain misc repair to drain, fencing, gates, pathway, boundary wall etc and Repairs/Replacement and cleaning of manholes, septic tanks and sewage line at New Mil Stn Kapurthala under GE Kapurthala.
BOQ Items
... More
M&L for brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Engn-in-Charge.
153.2
-
-
... More
All as per item No 4 here in before but except bricks complete all as specified and directed by Engn-in-Charge.
10
-
-
... More
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engn-in-Charge.
60
-
-
... More
All as per item No 6 here in before but except bricks complete all as specified and directed by Engn-in-Charge.
10
-
-
... More
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engn-in-Charge.
100
-
-
... More
M&L for Cement concrete 1:5:10 type E-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engn-in-Charge.
30
-
-
... More
M&L for cement concrete (1:2:4) B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, benching, coping, bed blocks etc including use of necessary form work complete all as specified and directed by Engn-in-Charge.
8
-
-
... More
M&L for providing precast cement concrete Type B0 1:2:4 set in C:M 1:4 louvres and jallies, 40mm thick measured solid, including all mouldings but excluding frame (Pre cast frame shall be measured separately) complete all as specified and directed by Engn-in-Charge.
60
-
-
... More
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engn-in-Charge.
2.5
-
-
... More
M&L formachine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and directed by Engn-in-Charge.
150
-
-
... More
M&L for chequered coloured cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry and pigments as in floors over 15mm thick screed bed in cm mortar 1: 6 complete all as specified and directed by Engn-in-Charge.
60
-
-
... More
M&L for rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:4 finished even & smooth without using extra cement complete all as specified and directed by Engn-in-Charge.
730
-
-
... More
M&L for preparation of plastered and un plastered surface of wall by applying two coat of exterior emulsion paint over a coat of primer complete all as specified and directed by Engn-in-Charge.
550
-
-
... More
M&L for keyed pointing to brick work as in CM (1:4) complete all as specified and directed by Engn-in-Charge.
10
-
-
... More
M&L for preparation of old Plastered or Unplastered surface of wall shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of exterior emulsion paint complete all as specified and directed by Engn-in-Charge.
500
-
-
... More
Taking down old unsv steel gates any size any shape any description complete all as specified and directed by Engn-in-Charge.
200
-
-
... More
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, confirming to Gde Fe410-O or Fe-310-O, complete all as specified and directed by Engn-in-Charge.
200
-
-
... More
S&F expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanized steel staples supplied and fixed complete to wood or steel members not exc 4 kg complete all as specified and directed by Engn-in-Charge.
50
-
-
... More
M&L for 25 mm thick Cement Conrete 1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even & smooth complete all as specified and directed by Engn-in-Charge.
50
-
-
... More
M&L for 50 mm thick Cement Conrete 1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra complete all as specified and directed by Engn-in-Charge.
200
-
-
... More
M&L for glazed ceramic coloured tiles of size 450X 300X 8mm thick as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:4 complete all as specified and directed by Engn-in-Charge.
100
-
-
... More
M&L for non skid ceramic coloured tiles with matt finish, 6 to 8 mm thicksquare or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade as in floors over 15mm thick screed bed in cm 1:6 complete all as specified and directed by Engn-in-Charge.
50
-
-
... More
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in conc or brick masonary and making good disturbed ground complete all as specified and directed by Engn-in-Charge.
250
-
-
... More
Dismantling fencing wire mesh, any type, any size complete all as specified and directed by Engn-in-Charge.
500
-
-
... More
S&F mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290. Gde E-165, complete all as specified and directed by Engn-in-Charge.
1870
-
-
... More
S&F in repairs galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at cross with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed by Engn-in-Charge. (Each line to be measured separately)
2
-
-
... More
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed by Engn-in-Charge.
2500
-
-
... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed by Engn-in-Charge.
500
-
-
... More
M&L for steel Round bars Fe-410 -W (Gde E-250) 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engn-in-Charge.
200
-
-
... More
S&F MS screw bolts (machine made) with hexagonal or square head at one end, screwed end to be fitted with washer and one hexagonal / square nuts exc 10 cm and not exc 15mm , dia of neck 5 to 10mm complete all as specified and directed by Engn-in-Charge.
10
-
-
... More
M&L for applying two coats of synthetic enamel paint on preparation of newly steel surfaces over a coat of Zinc chromate primer any description over 10 cm width of girth not otherwise described complete all as specified and directed by Engn-in-Charge.
50
-
-
... More
M&L for applying two coats of synthetic enamel paint on preparation of old brick/Kerb stone/ concrete surfaces and repair demaged portion by any means like plastering and concreting any description over 10 cm width or girth not otherwise described complete all as specified and directed by Engn-in-Charge.
Note:- cost of repairing of demaged portion is included in this item.
50
-
-
... More
Desilting of existing drain removing of mud, soil, etc for a depth of 1m and deposit at 500m away from the site complete all as specified and directed by Engn-in-Charge.
3
-
-
... More
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified and directed by Engn-in-Charge.
85
-
-
... More
M&L for Plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engn-in-Charge.
21.42
-
-
... More
M&L for cleaning blockage of WC (EWC or IWC) by opening inspection door bend and using roding / pressure technique to clear blockage upto first manhole complete all as specified and directed by Engr-in-Charge.
400
-
-
... More
M&L for cleaning blockage of gully trap/floor trap upto first manhole by opening inspection door bend and using roding / pressure technique to clear blockage complete all as specified and directed by Engr-in-Charge.
400
-
-
... More
M&L for Cleaning of sludge, mud etc from manhole of any size and depth upto 4.50 m including getting out and removing and depositing the sludge outside of defence land and covering the manholes properly after completing the cleaning all as specified and directed by Engr-in-Charge.
400
-
-
... More
M&L for pumping out liquid or semi liquid from sewage wells/septic tanks/soakage pit of any size or any depth mechanically by sucking mechanical machine system (closed tank) and dispose off the same from out of defence land, complete all as specified and directed by Engr-in-Charge. During the cleaning of sewage wells, septic tanks and soakage pit the alternate temporary arrangemants shall be made by the contractor for clearing sewage disposal. No pumping is allowed in defence land.
800
-
-
... More
M&L for cleaning sewage lines of dia 150/200 /300 mm as in main sewage system having depth not exceeding 1.50 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge. (Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine & honey sucker for cleaning of central sewer pipe lines from manhole to manhole).
3500
-
-
... More
M&L for cleaning sewage lines of dia 150 / 200 / 300 mm as in main sewage system having depth exceeding 1.50 mtr but not exceeding 3.00 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge. (Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine for cleaning of central sewer pipe lines from manhole to manhole).
2000
-
-
... More
M&L for cleaning sewage lines of dia 150/200/300 mm as in main sewage system having depth exceeding 3.00 mtr but not exceeding 4.50 mtr by roding and other mechanical methods and removing taken out sludge outside the defence land complete all as specified and directed by Engr-in-Charge. (Length of line shall be measured from manhole to manhole and the contractor will provide sewer jetting machine & honey sucker for cleaning of central sewer pipe lines from manhole to manhole).
1300
-
-
... More
M&L for breaking up / puncturing existing badly blocked lines and clearing blockage before puncturing by excavating a manhole of suitable depth and size all as specified and directed by Engr-in-Charge. (The different items involved in excavating manhole shall be measured and paid for separately under appropriate items)
15
-
-
... More
Demolition of concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engr-in-Charge.
3.46
-
-
... More
Excavation in trenches not exc 1.5 m wide & not exc 1.5 m in depth for foundation, sewage lines and man holes etc not exc 10 Sqm on plan & not exc 1.5 m in depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
160
-
-
... More
Excavation in trenches not exc 1.5 m wide & notexc 3 m in depth for foundation sewage lines and man holes etc n.exc 10 Sqm on plan & exc. 1.50 m but n.exc 3 m in depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
150
-
-
... More
Demolition and breaking up 150mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
Demolition and breaking up 200mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
Demolition and breaking up 300mm bore drain pipe of any type, in cement mortar and taking out from tranches complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
S&F Reinforced concrete pipes,150 mm Dia class NP2, laid and jointed complete with collars all as specified and directed by Engr-in-Charge.
200
-
-
... More
S&F Reinforced concrete pipes,200mm Dia class NP2, laid and jointed complete with collars all as specified and directed by Engr-in-Charge.
100
-
-
... More
S&F Reinforced concrete pipes,300MM Dia class NP2, laid and jointed complete with collars all as specified and directed by Engr-in-Charge.
100
-
-
... More
Returning filling in incl spreading leveling and well ramming in layers n.exc 25 cm in soft/loose soil all as specified and directed by Engr-in-Charge.
75
-
-
... More
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above starting point all as specified and directed by Engr-in-Charge.
235
-
-
... More
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone agg) as in foundation of man holes complete all as specified and directed by Engr-in-Charge.
2.88
-
-
... More
M&L for pre cast cement concrete 1:2:4 as in man hole covers type B-1 (20 mm graded agg) as in manhole cover set in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
3.46
-
-
... More
S&F for TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia all as specified and directed by Engr-in-Charge.
400
-
-
... More
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 150mm bore pipe complete all as specified and directed by Engr-in-Charge.
200
-
-
... More
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 200mm bore pipe complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) concrete bed to drain pipe incl packing under and haunching against the sides of pipe as they are laid and tested for 300mm bore pipe complete all as specified and directed by Engr-in-Charge.
100
-
-
... More
S&F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
15
-
-
... More
M&L for cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 /200/300mm bore drain pipe complete all as specified and directed by Engr-in-Charge.
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements