Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Bridge Construction
Eprocure
Opening Date7 Dec 2024
Closing Date14 Jan 2025
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, painted with a shop coat of red oxide primer complete all as specified and directed.

60

4

-

... More
S&F pressed steel frames for doors/windows of size size 105x60 mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, painted with a shop coat of red oxide primer complete all as specified and directed.

140

5

-

... More
S&F 35mm thick factory made plain framed panelled shutters of 2nd class hard wood, two panels with lock rail and panel of 9mm thick BWP commercial ply. The size of rail and stile as per IS-1003 (Part-I), Kiln seasoned and chemically pressure treated complete all as specified and directed.

65

6

-

... More
S&F 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per section 8 clause 8.20 (a) of SSR Part-I complete all as specified and directed

38

7

-

... More
S&F Solid PVC door frame of size 50 x 47 mm made out of 5mm wood grain printed PVC sheet & edges shall be painted to match with printed sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.

65

8

-

... More
S&F Factory Made Solid PVC Moulded door Shutter With wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick prelam Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.

20

9

-

... More
S&F Box type Steel windows and ventilators comprised of tubular frame and shutters made out of 1.25mm thick MS steel tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire mesh and glass panes shall be measured and paid separately) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 Nos tower bolts 150mm long for each leaf and 8mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks (1:2:4 type 12.50mm graded crushed stone aggregate) including two coats of synthetic enamel paint over a shop coat of red oxide primer etc. all as shown on drg No CEPZ /TD-354/09 sheet 1/3 to 3/3 complete all as specified and directed.

60

10

-

... More
S&F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or galvanized wire staples complete all as specified & directed.

25

11

-

... More
S&F 100 mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed.

100

12

-

... More
S&F for 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed

32

13

-

... More
S&F aluminium anodized barrel tower bolts 200 mm of extruded section (as per sample) fixed complete all as specified and directed.

190

14

-

... More
S&F 150 mm size aluminium alloy handles, febricated type extruded section (as per sample), complete all as specified and directed.

190

15

-

... More
S&F 300mm, ordinary rat tail rod pattern door springs including roller and roller plate complete all as specified and directed.

16

16

-

... More
S&F 100 mm long hasp and staple , mild steel , wire type stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified.

16

17

-

... More
S&F in repair 20mm bore stainless steel, single curtain rod (walls thickness not less than 1mm) including fancy type both sides brackets, fenials etc (as per sample) suitable for single curtain rod complete all as specified and directed.

80

18

-

... More
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillar etc but excluding ashlar facing , dressed stone work and precast concrete articles, and removal of debris out off the premises etc complete all as specified and directed.

6

19

-

... More
M&L for Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified & directed.

5.2

20

-

... More
M&L for Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified & directed.

3

21

-

... More
Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed.

1800

22

-

... More
M&L for Rendering 10mm thick on fair faces of brick work, concrete sruface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed.

818.3

23

-

... More
M&L for rendering 5mm thick in CM 1:3 on concrete surface of ceiling, chajja etc, finishing the surfaces even and smooth without using extra cement including taking down of existing plaster of any description and removal of rubbish complete all as specified and as directed.

300

24

-

... More
M&L for 15mm thick plaster in two layers (10+5mm) in cemet mortar 1:4 external layer of plaster shall be mixed with liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc, surface finished even and smooth with using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid for separately.

750

25

-

... More
M&L for plastering 10 mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape and finishing the surface without using extra cement complete all as specified and directed.

50

26

-

... More
M&L for preparation of new plastered surface of external wall and chajjas, making surface smooth using sand paper, priming the surface with alkali resistance primer paint for external surface, applyingapplying two coat of exterior emulsion (weather coat ) paint complete all as specified & directed.

800

27

-

... More
M&L Preparation of new plastered surface of wall by applying one coat wall care putty and making the surface smooth and two coats of distemper oil emulsion over a coat of primer of new surfaces complete all as specified and directed

700

28

-

... More
M&L for preparation of new plastered surface of walls and applying three coats of white wash complete all as specified and directed.

168.3

29

-

... More
M&L three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as spd and directed.

300

30

-

... More
M&L for preparation of new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.

15

31

-

... More
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.

110

32

-

... More
M&L for Complete removal of existing treatment from walls, brooming down with broom or steel wire brush; scrapping down smoke soot, moulds, mass, efflorescent salts, trading oil and greasy spots etc, applying wall care putty, making the surface even and smooth and applying two coats of oil emulshion distemper over a coat of primer complete all as specified & directed Note: Where thickness of putti is required more than 1mm thick, the same shall be make good using POP and than putti shall be applied to obtain even & smooth surface. Nothing extra shall be admissible on this account.

80

33

-

... More
M&L for Complete removal of existing treatment from walls, brooming down with broom or steel wire brush; scrapping down smoke soot, moulds, mass, efflorescent salts, trading oil and greasy spots etc, applying wall care putty, making the surface even and smooth and applying two coats of exterior emulsion (weather coat ) paint complete all as specified & directed.

50

34

-

... More
M&L for Complete removal of existing treatment from walls, brooming down with broom or steel wire brush; scrapping down smoke soot, moulds, mass, efflorescent salts, trading oil and greasy spots etc, applying wall care putty, making the surface even and smooth and applying two coats of white wash complete all as specified & directed.

30

35

-

... More
M&L two coats of white wash on surface of ceiling including preparation of old plastered surface complete all as spd and directed.

80

36

-

... More
M&L two coats of synthetic enamel paint on old steel surfaces of any description, n.exc 10 Cms in width or girth, including preparation of surfaces, complete all as specified and directed.

10

37

-

... More
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick (below or above ground level) and removal of rubbish beyond MOD land complete all as specified and directed.

6

38

-

... More
M&L for PCC type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair including making joints not more than 2.5 m (or as directed) and at corner, filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed.

90

39

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 15mm thick screed bed or bedding layer of mortar in CM 1:6 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises complete all as specified and directed.

48

40

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement laid over 15mm thick screed bed in CM (1:6) including dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises all as specified and directed .

390

41

-

... More
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in skirting/dado or verticle surface etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises complete all as specified and directed.

50

42

-

... More
M&L for glazed ceramic coloured tiles in vertical surface 450x300x7mm set and jointed (joint free) in neat cement slurry and pointed in white or coloured cement to match over 10mm thick screed bed or bedding layer of mortar in CM 1:4 including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding ( but not backing), rubish off the premises complete all as specified and directed.

240

43

-

... More
M&L green Marble work 18-20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including demolition of old stone slab/tiles of any description, removal of rubbish complete all as specified and directed.

60

44

-

... More
M&L for Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with 3.00 kg per sqm complete all as specified and directed.

60

45

-

... More
M&L for Round chamfering to the edges of marble/granite slabs not exc 15 mm wide complete all as specified and directed.

30

46

-

... More
Taking up or down steel water tubing and connections including cleaning for refixing of pipe 15mm bore complete all as specified and directed.

120

47

-

... More
Taking up or down steel water tubing and connections including cleaning for refixing of pipe 20mm bore complete all as specified and directed.

40

48

-

... More
S&F 15mm bore mild steel tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.

100

49

-

... More
Refixing of old steel tubing 15 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc complete all as specified and directed.

20

50

-

... More
M&L for cutting chases, pinning in brick work, making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth complete all as specified and directed.

80

51

-

... More
S&F 20mm bore tubes medium grade galvanized ISI marked with all fittings, short pieces and fixed to walls, floor, ceiling etc complete all as specified and directed.

30

52

-

... More
Refixing of old steel tubing 20 mm medium grade galvanized ISI marked with new all fittings short pieces and fixed complete to walls, floor etc all as specified

10

53

-

... More
S&F in repair 15mm bore dia angle valve / stop valve cast copper alloy capston head chromium plated (as per sample), fancy type ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed.

32

54

-

... More
S&F 15mm bore dia angle valve / stop valve/ concelled cast copper alloy chromium plated fancy type, long shank ISI marked with crutch or butter fly handles screwed down, screwed for iron pipe complete all as specified and directed.

8

55

-

... More
S&F 15mm bore dia Bib taps long body, cast copper alloy, chromium plated fancy type ISI marked with crutch or butter fly handles, screwed down, screwed for iron pipe complete all as specified and directed.

32

56

-

... More
S&F Vitreous china wash basin, white flat back, size 550 x 400 mm brackets, CP waste coupling and cutting for and pinning in ends of brackets or errecting stand including 32 mm dia waste pipe complete all as specified and directed.

8

57

-

... More
S&F in repair SS grating 100 mm dia complete all as specified and directed.

8

58

-

... More
S&F in repair glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated brackets double guard and railing 60cm long, complete all as specified and directed.

8

59

-

... More
S&F towel rail, brass, CP 600 mm long 20mm dia pipe of 1mm thick complete all as specified and directed.

8

60

-

... More
S&F 600 mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick AC building board or BWP commercial plywood and fixed to wooden plugs/PVC rawl plug with chromium plated brass screws and cup washers complete all as specified and directed.

8

61

-

... More
S&F in repair 15mm bore pillar tap cast copper alloy, fancy type, long neck, screwed down high pressure with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe complete all as specified & directed.

8

62

-

... More
M&L for of 15mm dia Brass CP wall mixer for mixing hot & cold water 450mm long screwed down for iron pipe and fixed cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.

8

63

-

... More
S&F in repair vitreous china, squatting Pan 'Orissa' pattern 'white' size 580mm x 440mm white with integral footrest including provision of lean concrete bedding, connection to drain out pipe, flush pipe, flush pipe and anti syphonage pipe etc, making good to floor where required complete all as specified & directed.

8

64

-

... More
M & L Plain cement concrete 1:5:10 type E2 using 40mm graded crushed stone aggregate as in sunken floors portion including demolition of PCC & removal of rubbish complete all as specified and directed.

1

65

-

... More
M&L for water proofing treatment to sunken floor with the following course of treatment/ specifications:- (i) Cleaning top surface of floors /slabs and laying 50 mm thick (avg) PCC 1:2:4 type B0 (using 12.50mm graded crushed stone aggregate) including coveting corners mixed with WPC as per manufactrrer's instruction laid in slope 1:20 towards spout. (ii) Provide 10 mm thick plaster in CM (1:4) on sides mixed with WPC as per manufacturer's instruction. (iii) Applying 1st layer of cement slurry @ 0.488 kg / sqm mixed wth acrylic based polymer modified cementious compound @ 0.253 kg /sqm. (This layer shall be allowed to air cured for 4 hrs). (iv) Applying 2nd layer of cement slurry @ 0.242 kg/sqm mixed with accrylic based polymer modified cementenous compound @ 0.126 kg/sqm.(This layer shall be allowed to air cured for 4 hrs). followed with water curing for 48 hrs. (v) Applying a coat of industrial bitumen 85/25 penetration @ 1.50 kg/sqm on plastered and concrete surfaces (vi) Provide 150 micron thick polyutethene paint in two coats (each of 75 micron measured dry on dry surface over a coat of PU primer including preparation . (Make of PU primer - Dek guard EP -302 of M/S Fosroc or equivalant approved brand. Make of PU paint - Dek guard PUor equivalant approved brand). (vii) Provide 2 Nos 32mm bore GI medium grade 450mm long spout through external wall to drainout accumulated water. (viii) Sunken floor shall be tested for water tighness by filling water for 72 hrs before and after treatment work is carried out and ensure that no leakage /seepage exists (ix) Sunken portion shall be filled with lean concrete 1:5:10 type E2 using 40mm grade stone agregate.

5

66

-

... More
S&F in repair PVC low level flushing cistern 10 ltr capacity, inlet and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and directed.

8

67

-

... More
S&F PVC connection 15 mm dia & length 450 mm with PTMT nuts complete all as specified and directed.

32

68

-

... More
M&L for Rotational moulded polyethylene water storage tanks ( cylindrical vertical with closed top) two layers, Capacity 500 litres, ISI Marked including all accessories, hoisted and fixed in position all as specified in SSR Part-I including dismantling of old tank, removal from site and disposal beyond MOD land complete all as specified and directed..

8

69

-

... More
S&F in repair 20mm bore dia gun metal globe or gate valves (as per sample) cast copper alloy chromium plated fancy type, ISI marked with crutch or butter fly handleswith iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed

32

70

-

... More
S&F for 110mm bore PVC(SWR) rainwater pipes including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.

90

71

-

... More
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors including taking down eaves gutters and rainwater pipes (any size or pattern), including all fitting, head, shoes, bend, swan-nacks etc., including cleaning or refixing and removal complete all as specified & directed.

40

72

-

... More
S&F 110 mm PVC(SWR) reducer complete all as specified and diretced.

15

73

-

... More
S&F PVC (SWR) branch piece, single (single Y) equal or unequal, or with parrallel branches fitted with oval access doors of 110 mm bore dia complete , ISI Marked, fixed in repairs all as specified & directed.

15

74

-

... More
S&F 110mm dia PVC (SWR) bends any radius (larger bore measured) complete all as specified and directed.

12

75

-

... More
S&F 75 mm dia PVC (SWR) bends any radius (larger bore measured) complete all as specified and directed.

10

76

-

... More
S&F cast iron 100mm bore Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fitted with ovel access doors complete all as specified and directed.

8

77

-

... More
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and directed.

4

78

-

... More
S&F in PVC floor trap 75 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 with CP grating with ot without hole for waste pipe complete all as specified and directed.

8

79

-

... More
S&F in repair kitchen sinks with drainage board made of stainless steel 1mm thick with plugs, washers , PVC waste pipe fixed in repair including waste copling; bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.

8

80

-

... More
S&F in repair stainless steel kitchen plate rack of size 750 x 900 mm not less than 1mm thick sheet thickness of approved make fixed with mild steel screw complete all as specified and directed.

8

81

-

... More
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed.

25

82

-

... More
S&F Mild steel TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified & directed.

20

83

-

... More
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick (below or above ground level) and removal of rubbish beyond MOD land complete all as specified and directed.

1

84

-

... More
M&L for PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof mixed with WPC as per manufacturer's instruction, surface finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid for separately.

7

50

-

... More
M&L for PCC 1:2:4 Type B1 (using 20 mm graded crushed stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, benching, copings, kneelers, apex stones, bed plates, kerbs , fillet, gola, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed

1

51

-

... More
M&L 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth mixed with liquid water proofing compound as per manufacturer instruction including raking out joingts, hacking for key, scrubbing down with water etc complete all as specified and directed. Note : WPC shall be measured separately.

250

52

-

... More
M&L for APP modified roof treatment over existing RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) All Shifting/ removing of any wire/cable/AC unit/Water tank of any capacity or other any object as per site requirement an re-fixing the same, if needed shall deemed to be included in the quoted rates by the contractor. (f) Removal of any loose/packed items such as mud phuska, terrace tiles, cement screed bed shall be removed and surface shall be made free from depressions before applying treatment to the roof. Quoted rates shall deemed to be included this fact into account and no extra payment shall be made on this account.

250

53

-

... More
Supply only liquid water proofing compound complete all as specified and directed.

5

54

-

... More
M & L for cleaning, breaking, loose concrete, changing of corressive reinforcement and filling plain cement concrete 1:1 1/2 :3 type B0 using 12.5mm graded aggregate using approved bonding chamical at places like old Reinforcement & chajja ,sunchades ,roof projection ,fascia ,coloumns etc as per direction by E-in-Charge (the cost of scafoldings, formworks deemed to be included in the item) Note :- Reinforcement shall be measured and paid seperately.

30

55

-

... More
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth for foundation etc or for shafts, well, cesspits, manholes, pier holes, etc n exc 10 sq m on plan and n exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed.

5

56

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.

1.5

57

-

... More
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.

2.5

58

-

... More
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.

1.5

59

-

... More
Cutting into existing manholes for connecting new drains for ineternal dia of pipe 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.

4

60

-

... More
S&F in repairs cabinet PVC size 510 x 490 x 100 mm with looking mirror full openable door complete all as specified & directed.

8

61

-

... More
S&F in repair glass shelf assembly consisting of 5.5mm thick sheet glass 12cm wide with chromium plated brackets double guard and railing 60cm long, complete all as specified and directed.

8

62

-

... More
M&L for Providing, precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates), as in cover slabs (for septic tanks, manholes and the like) and similar articles including necessary moulds/fromwork etc, set and jointed in cement mortar (1:6) complete all as specified and directed.

1

63

-

... More
S&F for 18 to 20 mm thick prelaminated PVC solid board with acrylic lamination not less 0.50 mm thick one side decorative choice laminate and other side balancing white and with weight of sheet not less than 9kg per sqm as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed.

35

64

-

... More
All as item no 99 but both side without printrd

19

65

-

... More
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed.

25

66

-

... More
Rolled mild steel as in framing for cledding glazing & the like fixed with angle cleats & conecting plates, etc conforming to Fe-410-w(Gde-E-250) quality 'A' complete all as specified and directed.

73

67

-

... More
Surface dressing n exc 15 cm deep in soft/loose soil complete all as specified and directed.

490

68

-

... More
Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.

62

69

-

... More
M&L for 60mm thickness M-35 grade Machine pressed precast concrete factory made paver block confirming to IS-15658-2006 (topping thickness not less than 5mm thick with white cement and colour pigment non fadable epoxy coating) complete all as specified & directed.

490

70

-

... More
M&L for 100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub floors, sub bases, floors and pavings etc complete all as specified and directed.

490

71

-

... More
M&L 25mm thick sand filling in floors or paving incl levelling , watering and consolidation complete all as specified and as directed.

12

72

-

... More
PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.

20

73

-

... More
Taking down carefully unsv copper/aluminium point wiring (light/fan/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sketch fitting etc removing materials to store for keeping in safe custody for taking creit and making good to disturbed surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed.

260

74

-

... More
M&L for point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI/MS modular sunken box of required size with support frame (inner/outer) for mounting modular switch , sockets etc including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed. Note:- 1) Conduit shall be fixed on surface/ceiling with necessay saddles where concealing of conduit is not feasible. 2) Rate of supplying and fixing modular GI/MS pressed sunken box with support frame deemed to be included in the quoted rates.

168

75

-

... More
All as per Ser item No 110 but for one 5/6 Amp socket outlet point on same board controlled by one switch.

32

76

-

... More
All as per Ser item No 110 but for one 5/6 Amp socket outlet points on independent board controlled by one switch.

32

77

-

... More
All as per Srl item No 110 here-in-before but for one 15/16 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor.

24

78

-

... More
All as per Ser item No 110 but for two way point controlled by two switches.

4

79

-

... More
S&F switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed.

232

80

-

... More
S&F socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type, 240 volts complete all as specified and as directed.

64

81

-

... More
S&F switch 15/16 Amps, flush type, 240 volts complete all as specified and as directed.

24

82

-

... More
S&F socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed.

24

83

-

... More
S&F switch piano flush button single pole two way 6 Amp 240 volts complete all as specified and as directed.

8

84

-

... More
S&F Bell push, flush type, 5/6 Amp AC 230 Volt etc complete all as specified and directed.

8

64

-

... More
S&F stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W complete all as specified and directed.

32

65

-

... More
S&F Bell Ding Dong AC 230 Volt, single Pole etc complete all as specified and directed.

8

66

-

... More
S&F Lamp holder jumbo modular type, PVC/Polycarbonate type with back plate suitable for batten fitting including 15 W LED lamp complete all as specified.

40

67

-

... More
S&F ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals.

124

68

-

... More
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit, removing materials to store for keeping in safe custody for taking credit complete all as specified.

50

69

-

... More
M & L for sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including suitable size concealed rigid medium grade PVC conduit not less than 20mm dia 1.5mm thick with all accessories incl cutting chases on wall and making good to the disturbed surface of wall/floor with cement mortar 1:4 and finishes to match existing surface complete all as specified and directed.

50

70

-

... More
Taking out carefully electric meters from meter box after disconnecting electrically and repair/replacement of burnt links, cable peices, drawing cables through PVC flexible conduit of suitable size and refixing the electric meter in same or other indicated location in meter box and sealing meters with high grade tranparent polycarbonate material and galvanized steel wire of suitable length and making electric connections using copper/brass thimbles complete all as specified and directed. Note : (i) Rate of PVC flexible conduit deemed to be included in quoted rates. (ii) PVC wire should be measured and paid seperately under respective item.

8

71

-

... More
Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing and greasing complete. Re-assembling and refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors for complete fan as required, testing complete after servicing and fixing for smooth and noise free operation complete all as specified and directed.

48

72

-

... More
Disconneting & taking down geyser any type/capacity complete, refixing to the same/other location with all connected accessories afer cleaning replacing anchor bolts complete all as specified and directed.

8

73

-

... More
S&F 20W surface / wall mounted box type batten LED fitting having polycarbonate housing and diffuser and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed.

36

74

-

... More
All as per ser item No130 but for 10 W LED batten fitting 2 feet long.

8

75

-

... More
S&F surface mounted, bulk head LED luminaire 10 W with and integrated electronic driver with system luminous efficacy ≥ 100 lumens/Watt operating voltage 140V-240V, IP 65 protection complete with all accessories internally prewired and including connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting complete all as specified and directed.

20

76

-

... More
S&F round/square shaped LED 15Watt recessed type panel, 220 volts AC with Polycarbobnate housing and high efficiency diffuse for glare free light complete with drivers, mounting clips suitable for roof ceiling including connecting up suitabel size flexible copper conductor cable complete all as specified and directed.

8

77

-

... More
S&F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 3 pole 415 V, 63 Amps, 16 kA of the same make as of distribution board, making connection with suitable size thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface in CM 1:4 to match the surface as per existing complete all as specified and directed.

2

78

-

... More
M&L for SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar, neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete fixed flush in wall including cutting chases on wall for taking out old DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface complete all as specified and directed. Note: MCBs will be measured and paid seperately under respective items

8

79

-

... More
S&F MCB SP 240V, 50Hz of rating 6 to 32 Amp, 'B' curve using suitable size copper thimbles complete all as specified and directed.

48

80

-

... More
All as per Ser item No 136 but for size 40-63 Amps MCB SP.

8

81

-

... More
S&F LED wall security lights of 25 Watt having pressure die cast aluminium housing with system lumens efficacy≥100 lumen/W, IP65 protection, IK07 rating, inbuilt electronic driver with PF0.95 incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable complete all as specified and directed.

4

82

-

... More
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit alongwith angel iron 40x40x3mm frame and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 3 of SSR part I 1991 or directed and testing on completion.

2

83

-

... More
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 80,992.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.