Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 99,800Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676599_1Bid Award Id
ViewTender No
8829/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINTENANCE/REPLACEMENT LT NETWORK PANEL AND CONNECTED ACCESSORIES AT NORTH MD ACCN UNDER GE UTILITY BATHINDA MIL STN
REPAIR/MAINTENANCE/REPLACEMENT LT NETWORK PANEL AND CONNECTED ACCESSORIES AT NORTH MD ACCN UNDER GE UTILITY BATHINDA MIL STN
REPAIR/MAINTENANCE/REPLACEMENT LT NETWORK PANEL AND CONNECTED ACCESSORIES AT NORTH MD ACCN UNDER GE UTILITY BATHINDA MIL STN
BOQ Items
M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed.
70
-
-
M&L for providing of new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
10
-
-
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc including excavation of any strata & relaxing taken out cable complete all as specified and directed.
2
-
-
M&L PCC (1:2:4) type C1 (using 20 mm graded crushed stone aggregate) in coping / plinth blocks for poles and the like including weathering , slightly rounded or chamfered angles and throating, as directed including necessary Steel form work and finishing the surfaces fair in forms complete all as specified and directed.
2
-
-
S & F in replacement of heat shrink insulation tubes for all the bus bars of Lt Panels and maintaining the RYB sequence in the system complete all as specified and as directed
200
-
-
M & L for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl copper strip 20x3 mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.5 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and incl galvanized strip 32x6mm as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 5 of SSR Part-I 1991 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
20
-
-
Cutting and trimming of tree branches to clear the over head lines in the arc of LT over head lines feeders complete in 2/4 pole structure/sub station area (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engineer-in-Charge. Notes :- All tools required for the job shall be arranged by the contractor within the overall cost quoted in the item.
20
-
-
Supply,fixing,commissioning and testing ACSR conductor of any size on existing LT pole including copper binding wire or aluminium tab, complete all as specified and directed by Engineer-In- Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
1
-
-
Restretching of LT ACSR conductor and GI wire of any size and on any type of poles including disconnecting from insulator and rewinding to insulator after stretching with and including aluminium wire including re-fixing/re-adjusting line spans, line separators, cross arms on poles all as specified.
30
-
-
Cross arms bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint after preparation of surface, complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
0.5
-
-
Repair and Replacement of damaged service cable incluing supply and fixing 1100 volt grade alluminium solid conductor cable with pvc armoured tape and overall pvc sheathed nominal cross section in service connction complete all as specified of following sizes :-.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
6 Sqmm 2 core
200
-
-
10 Sqmm 2 core
200
-
-
S&F in replacement MCCB 4 Pole, 415 V,of following breaking capacity, thermal magnetic type of capacity including all jointing materials like thimbles, tapes etc., complete all as specified and directed by Engineer-in-Charge fo following sizes :-.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
40/63/100 Amp 4 Pole, 16 KA
30
-
-
160 Amp, 4 P, 36 KA
10
-
-
200 Amp,, 4 P, 36 KA
10
-
-
250 Amp, 4 P, 36 KA
10
-
-
400 Amp, 4 P, 36 KA
8
-
-
630 Amp 4 P, 50 KA
4
-
-
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length heavy duty in repair/maintenance of cables or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
500
-
-
Cutting and trimming of tree branches to clear the over head lines in the arc of HT/ LT over head lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of trees) and removal of the trimmed branches of trees, removing and depositing the same away from the site, complete all as specified and directed by Engr-in-Charge. NOTE : All tools required for the job should be arranged by the contractor with in the overall cost quoted in the item.
300
-
-
Supplying, laying, jointing and testing in replacement of u/s LT underground cable, heavy duty, 1100 Volts, XLPE insulated and sheathed, armoured with multi-stranded aluminium conductor cable , laid in trenches/ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes complete all as specified and directed of following sizes:-
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
70 sqmm, 3.5 core.
200
-
-
35 sqmm, 3.5 core.
400
-
-
25 sqmm, 04 core.
200
-
-
16 sqmm, 4 core.
300
-
-
10 sqmm, 4 core.
300
-
-
185 Sqmm 3.5 core
150
-
-
300 Sqmm 3.5 core
300
-
-
Supply only for Aluminium thimble/ferrule suitable for LT UG Cable,1100V for the following size of cable:-
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
25 Sqmm
30
-
-
35 Sqmm
30
-
-
50 Sqmm
30
-
-
70 Sqmm
30
-
-
95 Sqmm
30
-
-
120 Sqmm
30
-
-
150 Sqmm
30
-
-
185 Sqmm
30
-
-
240 Sqmm
30
-
-
M&L for surface dressing not exc 15cm deep and averaging 10cm deep and cleaning of surroundings of electrical installations/sub stations/2 & 4 pole structure/Panels/transformers drainage installation by cutting vegetation, bushes, grass etc. and surface dressing, complete all as specified and directed by Engineer-in-charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
600
-
-
S&F of following accessories in repair of Lt panels of various sizes at various location complete all as specifed by Engr-in Charge or GE :-
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
Volt meter digital, 96 x 96mm size, 0-500 volts, AC, complete all as specified and directed.
10
-
-
Ampere meter digital, 96 x 96mm size, 0-100A size, AC, complete all as specified and directed.
10
-
-
Phase indicating lamps LED type RYB, complete all as specified and directed.
10
-
-
Four position selector switch for ammeter/Voltage meter, complete all as specified and directed.
10
-
-
Die cast resin CT for digital Amp meter of any capacity and ratio of CT, complete all as specified and directed Engineer-in-Charge.
10
-
-
Wiring of voltmeter or ammeter with copper conductor single core 1.5 sqmm size, complete all as specified and directed.
10
-
-
Taking up or down defective/faulty LT underground cable 1100 volts of size upto 300 sqmm 3.5 core from the existing trench/duct/pole etc an Re-laying the same in the trenches/duct/pole etc after rectification of defects, including meggering of cable, provn of cable lugs, glands, thimble, insulation tape and connecting up with existing control gears, panels etc as per site requirement, complete all as specified and as directed. Note:- Excavation, returning filling etc shall be measured and paid seperately.
200
-
-
M&L for submain wiring with three single core 6 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 19/20mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete all as specified and directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
200
-
-
M&L for submain wiring with three run single core 10 Sqmm PVC insulated unsheathed copper conductor cable, drawn in and including 25mm dia PVC rigid non metalic conduit / flexibe PVC pipe medium density, ISI Marked, complete all as specified and directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
200
-
-
Supply & fix aluminium strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
100
-
-
Supply and fix in replacement busbar chamber wall mounted 8 way 250 Amps cubical type complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
2
-
-
Supply and fix in replacement busbar chamber wall mounted 8 way up to 315 Amps cubical type complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
2
-
-
Supply and fix in replacement busbar chamber wall mounted 8 way 400 Amps cubical type complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
2
-
-
Supply and fix in replacement busbar chamber wall mounted 8 way 630 Amps cubical type complete all as specified and directed.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
2
-
-
Supply and fixing in replacement amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) single pole and current carrying capacity of following sizes in the MCB DB or FRP looping box of security lights or Lt panels of poles/panelscomplete with connection testing and commissioning.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
240V, 10KA 'C' curve miniature circuit breaker (MCB) single pole and current carrying capacity 6 to 32 Amps
20
-
-
240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity 32/63 Amps in the MCB DB or FRP looping box of security lights poles/panels complete with connection testing and commissioning.
20
-
-
Supply, installation, commissioning and testing of factory made (CPRI approved) LT Panel outdoor type of suitable size, made out of 3.15 mm thick CRCA sheet duly compartmentalized inside panel with 2 mm thick CRCA sheet for fixing of MCCB & instumentations compartments and frame etc. to accommodate the incoming and outgoing MCCBs/ COs / Motor Starter duly powder coated (The inner/outdoor shell. will have powder coated siemens grey) and having provision for front and rear side opening with rubber beading and mild steel cable glands for each cable to make it weather and vermin proof. double door hinged type, both side openable, air fins for ventilation, The panel shall be placed on angle iron of size 50 x 50 x 6 mm frame supported on 04 legs 600 mm long each duly grouted in plain cement concrete blocks in 1:2:4 type B1 angle frame shall be provided with mild steel sheet 300 mm width and 1.6 mm thick on three sides duly fixed with nuts and bolts complete all as specified and directed. Panel shall comprise of the following:- (a) Aluminium bus bar mounted on insulators duly painted colour code 600 Amps - 3 Nos for phase and 200 Amps - 01 No for neutral. (c) Incoming MCCB 4 pole 3 phase, 250 Amps,415 Volts AC rupturing capacity 35 KA -01 No. (d) Out going MCCB's TP 100 Amps repturing capacity 25 KA - 03 No's (e) Out going MCCB's TP 63 Amps repturing capacity 25 KA - 02 No's (f) Two MCB DP for future. (g) Multifunction Meter Digital type showing V,A,F,Pf Kw,KWH in built Selector switch with CT coiles for three phase. Cat No WDM303FDWA1 of L&T Make:- L&T. (h) Indicator lamp neon type (RYB) with holder,one set for each incoming and out going - 03 Sets (j) Complete internal wiring with suitable sizes copper conductor PVC insulated all as per manufacturor design Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
1
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 630 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 400 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 300 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 200 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 160 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Checking, testing Taking out all the LT cables by cutting old rusted nuts,bolts etc, refreshing all the cables (one in comming and 4 to 8 out going) by providing new lugs, MS nuts, bolts & washers and required excavation work, returning filling, removal and making god. welding of panels hings including making proper locking arrangement of LT panel ront and rear doors and proper opening and clossing. Painting of LT Panels with smoke gray paint over a paint of redoxide. Marking incoming & out going feeder to particular block/ Bldg Nos with white paint etc. complete all as directed by engineer -in -charge.a) Excavtion and earth work for taking out cable loop will be included in the rate of the same deemed included in the quoted rate by the contractor, not paid seperately.
50
-
-
Taking down old unserviceable LT panel/ LT feeder pillrs of any discription and size including demolished PCC foundation and all accessories and shifted to other location complete all as directed by engineer -in -charge.
Note :- PCC Work or excavation for the same will be paid seperately in respective items.
30
-
-
Material and Labour for Preparation of the old painted surfaces of feeder piller box / panel of any size any description and in any position including removel of faded & deteriorated paint either by hand scrubbing or by blow lamps , applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) with using spray machine after coat of primer complete all as specified and as directed by Engineer-in-Charge.
80
-
-
Supply and fixing in replacement to any other existing panel, Aluminium bus bar 100 Amp capacity in existing LT Panel / feeder piller etc including provision of insulation tape RYBB in colour and holes, nuts bolt & mounting insulator of bus bar complete all as specified and as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
5
-
-
Supply, fabricating, installation, testing , commissioning and electrically connecting LT panel Board of suitable size , 415 volts ,factory made , machine pressed , dust and vermin proof , out door type made with CRCA sheet 3.15 mm thick , LT Panel internally and externally shall be painted with expoxy powder coating paint with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish. , both side opening in two halves with rubber beading , including aluminium bus bar of 630 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel and shall be mounted with angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge
(i) S&F Air circuit breaker 4 Pole 800 amps ,415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release, Manual drawout, A-Type - 01 (incoming) (ii) MCCB 400 Amp , 4 pole , 415 volts rating with breaking capacity 50 KA, adjustable setting = 80-100% and magnetic setting 50 Hz, Icu = Ics = 100% - 03 (outgoing)
(iii) S&F MCCB 4 Pole, 250 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type - 02 Nos
(ii) MCB 4 Pole, 63 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type -03 Nos.
(iii) Spare pocket for fixing of 01 No. MCCB with separate compartment - 01 No. (iv) Volt meter Digital type 0-500 volt with in built selector switch - 01 No. (v) Amp meter Digital type 0-200 Amp with inbuilt selector switch & CTs of suitable ratio - 01 No. (vi) Indicator lamp R,Y,B = 01 Set of three
(vii) Complete panel wiring with tagging and double layer of rubber bidding all as specified. Location- Core HQ Main Panel
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
1
-
-
Supply and fixing LT feeder piller box cubical type of size 60x40x30 cm,415 volts for outdoor use made out of CRCA sheet 3.15 mm thick powder coated ,machine pressed front opening with single door with provision of rubber beading and locking system including aluminium bus bar 4 strip of size 30 mm wide and 6 mm thick with provision of hole on bus bar fixing of cable mounted on PVC / epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/outgoing cables and testing complete all as directed by Engineer-in Charge. Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
10
-
-
Dismantling of U/S ACB and S&F ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual draw type of capacity of following sizes including testing & commisioning :-
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
-
-
-
S&F ACB 4 Pole,415 volt, with microprocessor release, adjstable release mannual draw type of capacity 630 Amps,65 KA including testing & commisioning .
1
-
-
~~~~Do~~~ but 800 Amps, 4 pole and 36 KA
1
-
-
~~~~Do~~~ but 1000 Amps, 4 pole and 36 KA
1
-
-
Supply, fabricating, installation, testing , commissioning and electrically connecting LT panel Board of suitable size , 415 volts ,factory made , machine pressed , dust and vermin proof , out door type made with CRCA sheet 3.15 mm thick , LT Panel internally and externally shall be painted with expoxy powder coating paint with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish. , both side opening in two halves with rubber beading , including aluminium bus bar of 630 Amp capacity , 4 strip mounted on porcelain insulator , bus bar chamber and shall be provided with inspection covers , Each MCCB / Cubical switch shall have be indipendent opening panel and shall be mounted with angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer , embeding and grouting in PCC 1:2:4 type B:1 20 mm graded crushed stone aggregate foundation including necessay earth work complete , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade comprising of following accessories including testing complete all as specified and directed by Engineer-in-charge i) S&F MCCB 4 Pole, 630 Amps ,415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and Adjustable Magnetic Type - 01 Nos (incoming) (ii)S&F MCCB 4 Pole, 400 Amps ,415 Volt of breaking capacity 36 KA (Ics=100 % Icu) with Adjustable Thermal and Adjustable Magnetic.- 02 (outgoing) (iii)S&F MCCB 4 Pole, 250 Amps ,415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type- 01 Nos (outgoing) (IV) MCB 4 Pole, 100 Amps, 415 Volt of breaking capacity 25 KA (Ics=100 % Icu) with Adjustable Thermal and fixed Magnetic Type -02 Nos.
(iii) Spare pocket for fixing of 01 No. MCCB with separate compartment - 01 No. (iv) Volt meter Digital type 0-500 volt with in built selector switch - 01 No. (v) Amp meter Digital type 0-200 Amp with inbuilt selector switch & CTs of suitable ratio - 01 No. (vi) Indicator lamp R,Y,B = 01 Set of three
(vii) Complete panel wiring with tagging and double layer of rubber bidding all as specified.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
2
-
-
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size 2 to 4 core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc all as directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
80
-
-
S&F cable jointing kit for Lt 1.1 KV cable for outdoor/indoor termination heat shinkable type end joint complete with jointing meterial and accessories suitable for XLPE armoured aluminium conductor cable of following sizes:-
-
-
-
400 to 630 sqmm 3.5 core
5
-
-
240 to 300 sqmm 3.5 core
5
-
-
150 to 185 sqmm 3.5 core
5
-
-
70 to 120 sqmm 3.5 core
10
-
-
25 to 50 sqmm 3.5 core
10
-
-
Taking out of Air circuit breaker 4 Pole 630 Amps to 1600 Amps, 415 Volt of breaking capacity not less than 50 KA to 65 KA with electronic/thermal/micro processor based release ,Manual drawout/Mechinical drawnout/ fixed , Any-Type/Make, , cleaning, servives & maint of any type ACB including replacement of worn out patrs and making fully smooth functioning upto to desire level , complete all as specified and as directed by Engineer-in-Charge. Note :- All the required spare parts will be included rates qouted by the contactor.
10
-
-
Demolitiong of old earth pit and Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
15
-
-
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20cm x 15cm size complete all as directed by Engineer-in-Charge.
Note :- Old unserviceable material should be deposited to the MES E/M stroe by the contractor by his own arrangements without any financial benefits complete all as specified by Engineer in Charge and GE.
200
-
-
Note:- The contractor shall deposited the old material retrived from item no 01 to 50 to AGE E/M Electric Supply store yard and shall maintain the record for the same.
-
-
-