Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 40,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677910_2Tender No
8042/GE/E/FZR/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and spreading clean dry sand in trenches for cushioning all as specified for cable protection complete all as directed.
25.15
-
-
Supply and lay bricks of sub class 'B' type for protection of U/G cable in trenches all as specified and directed.
2.11
-
-
Supply and Fix XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 400 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified.
90
-
-
Supply and Fix XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 240 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified.
90
-
-
Supply and Fix XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 120 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified.
90
-
-
M&L for painting of LT Panel complete with two coats of synthetic Enamel paints over a coat of red oxide and other necessary fabrication work like replacement of hinges ,locking Knobs, bending and welding work required for hinges etc as per required at site complete all as Specified and directed by Engr -in- Charge
11
-
-
Supply and fixing in replacement Digital Ammeter class 0.5, 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A complete all as Specified and directed
6
-
-
Supply and fixing in replacement Digital Volmeter class 0.5 , 0 - 500 Volts digital type square shape flush mounted with selector switch complete all as specified and directed.
6
-
-
Supply and fixing in replacement Aluminium Bus Bar/extended strips of MCCBs, of suitable rating as per required size at site complete all as Specified and directed
50
-
-
Supply and fixing in replacement single run PVC insulated multicore standard shealthed copper conductor cable of 50 Sqmm single core for internal wiring inside the LT Panel as per standered color coding for three phase and neutral including Copper thimbles of suitable size with nut bolts and insulated from common bus bar to outgoing MCCB complete all as specified.
60
-
-
Supply and fixing in replacement single run PVC insulated multicore standard sheathed copper conductor cable of 70 Sqmm single core for internal wiring inside the LT Panel as per standered color coding for three phase and neutral including Copper thimbles of suitable size with nut bolts and insulated from common bus bar to outgoing MCCB complete all as specified.
60
-
-
Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 2.0 m x 1.6 m x 0.8 m ) with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed.Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:- LOC:- SBS Enclave & Pump No. 19,197 fd Regt, 5 Madras & 99 Jhoke Road, Church Road.
(i) Panel having common aluminium bus bar of capacity 1000 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.
(ii) Incoming:-
(a) ACB 4 Pole, 415 V, Microprocessor release type (Manual Draw out type) of capacity 630 Amps.(Incoming)
(iii) Outgoing:-
(a) MCCB Thermal release based adjustable type with suitable size and capacity,250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(outgoing)
(b) Same as above but of Capacity 200 Amps, 4 Pole 36 KA -01 Nos .(outgoing)
(c) Same as above but of Capacity 160 Amps, 4 Pole 36 KA -02 Nos .(outgoing) (d) Same as above but of Capacity 100 Amps, 4 Pole 25 KA -01 Nos .(outgoing)
(e) Same as above but of Capacity 63 Amps, 4 Pole 25 KA -02 Nos .(outgoing)
(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Set
(v) Ammeter 0 - 630 Amps digital type square shape 96mm flush mounted with selector switch and CT's 630/5 A - 1 Nos Set.
(vi) Indicator lamp RYB :01 Set. with CT Coil complete.
2
-
-
Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.8 m x 1.45 m x 0.8 m ) with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed.Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:-
(i) Panel having common aluminium bus bar of capacity 800 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.
(ii) Incoming:-
(a) MCCB Microprocesor based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 400 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.( Incoming)
(iii) Outgoing:-
(a) MCCB thermal released based Adjustable type with suitable size and capacity, 250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(outgoing)
(b) Same as above but of Capacity 160 Amps, 4 Pole 36 KA -01 Nos.(outgoing) (c) Same as above but of Capacity 100 Amps, 4 Pole 25 KA -01 Nos.(outgoing) (d) Same as above but of Capacity 63 Amps, 4 Pole 25 KA -02 Nos.(outgoing)
(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos ser.
(v) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos set.
(vi) Indicator lamp RYB :01 Set. with CT Coil complete.
2
-
-
Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts, Front & Rear openable double door with locking arrangement. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m ) with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm , thimbles including cable entry glands, all as directed. Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:-
(i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB's,including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii)(ii) Incoming:-
(a) MCCB microprocessor based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(Incoming)
(iii) Outgoing:-
(a) MCCB thermal released based adjustable type with suitable size and capacity, 160 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% - 01 Nos.(outgoing)
(b) Same as above but of Capacity 100 Amps, 4 Pole 25 KA -01 Nos .(outgoing)
(c) Same as above but of Capacity 40 Amps, 4 Pole 16 KA -04 Nos .(outgoing)
(iv) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos set
(v) Ammeter 0 - 250 Amps digital type square shape 96mm flush mounted with selector switch and CT's 250/5 A - 1 Nos set.
(vi) Indicator lamp RYB :01 Set. with CT Coil complete.
Note for item 15 to 17
1. All the Existing cables shall be fixed with glands,lugs etc at requisite site.
2. If size of LT panel exceeds than min size no extra payment shall be paid to the contractor.
2
-
-
S&F of MCCB Microprocesor based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 400 Amp 4 Pole ICU = ICS = 36 KA with overload variation 40-100% fixed in repairs, complete all as specified & directed.
3
-
-
S&F of MCCB of capacity 250 Amps, Adjustable Type 4 pole, 415volt, 50Hz, rupturing capacity 36 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed.
8
-
-
All as per Item No 19 but 200 A 36 KA.
10
-
-
All as per Item No 19 but160 A 36 KA.
10
-
-
S&F of MCCB of capacity 100 Amps, Adjustable Type 4 pole, 415volt, 50Hz, rupturing capacity 25 KA (minimum) or higher, AC, 50 C/S, fixed in repairs, complete all as specified & directed.
10
-
-
Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts.The panel board shall be made of 3.15 thick CRCA sheet (Min size 0.6 m x 0.5 m x 0.35 m ) with Synthetic enemal Paint both side. Base frame of the panel shall be made of angle iron of size 50 x50 x 6mm of upto 1/2 mtr hight from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregates comprising of following:- The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following:- (i) Epoxy insulated common aluminium bus bar of capacity 315 Amp TPN each with Color Coding , including aluminium lugs to connect the cable. (ii) Volt Meter 0 - 500 Volts digital type square shape flush mounted with selector switch - 1 Nos
(iii) Ammeter 0 - 400 Amps digital type square shape 96mm flush mounted with selector switch and CT's 400/5 A - 1 Nos.
(iv) Indicator lamp RYB :01 Set complete
5
-
-
Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate not less 1.5 metre (BGL) connected to galvanized iron earth strip 32 x6 mm by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 50 mm bore “light grade” galvanized iron protection pipe for earth strip 32 x6 mm upto 5m length, charcoal, common salt, complete all as shown in EP No 1 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion, complete all as specified and directed.
14
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%