Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Sep 2024
Closing Date2 Nov 2024
Tender Amount₹ 49,65,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT/REPLACEMENT OF LT NETWORK PANEL AND CONNECTED ACCESSORIES AT SOUTH MD ACCN UNDER GE(U) BATAINDA MIL STN.
REPAIR/MAINT/REPLACEMENT OF LT NETWORK PANEL AND CONNECTED ACCESSORIES AT SOUTH MD ACCN UNDER GE(U) BATAINDA MIL STN.
REPAIR/MAINT/REPLACEMENT OF LT NETWORK PANEL AND CONNECTED ACCESSORIES AT SOUTH MD ACCN UNDER GE(U) BATAINDA MIL STN.
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing of surplus excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified.

291.19

-

-

... More
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)

259.2

-

-

... More
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified. Make :- Topaz / Mehtab

21333

-

-

... More
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as specified and as directed by Engineer-in-Charge.

3100

-

-

... More
Supply and fixing XLPE, LT Cable of size 300 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
All as per serial item No. 08 above but for cable of size 185 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and directed by Engineer-in-charge.

300

-

-

... More
All as per serial item No. 08 above but for Cable of size 120 Sqmm, 3.5 core,

300

-

-

... More
All as per serial item No. 08 above but for Cable of size 70 Sqmm, 3.5 core,

500

-

-

... More
All as per serial item No. 08 above but for Cable of size 25 Sqmm, 4 core,

500

-

-

... More
All as per serial item No. 08 above but for Cable of size 16 Sqmm, 4 core,

700

-

-

... More
All as per serial item No. 08 above but for Cable of size 10 Sqmm, 4 core,

500

-

-

... More
Un binding from old insulators and taking down old unservicable insulators and re–stretching only existing ACSR of any size on LT poles including binding the ACSR with new insulators with and including aluminium binding wire 2mm dia complete all as specified and as directed by Engineer-in-charge. Note :- The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account.2 New insulators shall be measured and paid seperately under respective item of this scheule of works

200

-

-

... More
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed by Engineer-in-charge. Note :-For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00mtr measurment and payment shall be considered proportionally.

500

-

-

... More
Supply and fixing in replacement for shackle type porcelain, vitreous, white, brown or green insulator of size 75mm height, 90mm dia for working pressure 1100 volts including galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm complete all as specified and as directed by Engineer-in-charge.Note:- The rate of galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm is included in this item and nothing shall be paid extra.

40

-

-

... More
Supply and erecting pre-stressed concrete poles 9 mtr long of cross section (102mmx172mm) at top and (102mmx279mm) at bottom, class-10 complying with requirements of IS-1678-1978, zebra painting with two coats of synthetic enamel paint and making alternative black and white strips 30 cm each up to 1.5 mtr height from top of PCC foundation block, numbering of poles including necessary excavation & earthwork in any type of soil, PCC (1:4:8) in foundation , PCC (1:3:6) in coping , and dismantling the old pole and removal all the debris complete all as directed by the Engineer-in-Charge. Note:The T&P vehicles will be arranged by the contractor for transporting the pole from AGE (E/M) Elect store yard to site of work and the cost deemed to be included in the quoted rates.

20

-

-

... More
Material and Labour in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item.The payment shall be made as per actual weight of material. During weighting the weight of paint and primer shall not be considered for payment purpose.nothing shall be extra paid on this account.

1

-

-

... More
Material and Labour for in replacement of stay assembly comprising of GI stay bow 14 mm dia, 40 cm long complete with accessories as shown in Electrical plate No 1 of SSR Part - I using galvanised stay rod 20 mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick ,2 Nosf thimbles, MS clamps made out of 50mm x 6 mm flat iron, loop stay insulator, stay wire 7/8 SWG complete including painting all exposed surfaces of MS work including two coats of aluminium paint over a coat of red oxide zinc chromate primer complete all as specified and as directed by Engineer-in-Charge. Note : Loop type insulators, Earth work and concrete work shall be measured and paid for separately under the respective item of schedule.

2

-

-

... More
Supply , fixing and stretching in replacement ACSR of any size as per site requirement on existing HT/LT poles including binding on existing insulator with aluminium binding wire 2mm dia complete all as specified and directed by Engineer-in-charge. Note :- 1. For measurement and payment purpose only the weight of ACSR shall be considered .The weight of aluminium binding wire 2.00mm shall not be considered.2. The rate of aluminium binding wire 2.00mm is included in this item and nothing shall be paid extra on this account.

3

-

-

... More
Supply , fixing and Stretching in replacement 4mm dia GI earth wire / guard cradles on existing HT / LT poles binding with and including GI binding wire 1.63 mm complete all as specified and as directed. Note :- 1. For measurement and payment purpose only the weight of 4mm dia GI earth wire / guard cradles shall be considered .The weight of GI binding wire 1.63 mm shall not be considered.2. The rate of GI binding wire 1.63 mm is included in this item and nothing shall be paid extra on this account.

0.5

-

-

... More
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20cm x 15cm size complete all as directed by Engineer-in-Charge.

50

-

-

... More
Cleaning and preparation of old painted surface of LT PCC Pole / street light Pole up to 1.50 mtr height from top of PCC foundation block, making alternative black and white strips VE waterproof high density reflective self adhesive strips on pole ( each strip 30cm hight ) and writing pole nos. including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and as directed by Engineer-in-Charge.

100

-

-

... More
Supply and fixing in repair PVC separator suitable for 3/4 way conductor complete all as directed by Engineer-in-Charge.

150

-

-

... More
Supply and fixing in repair PVC separator suitable for 5/6 way conductor complete all as directed by Engineer-in-Charge.

150

-

-

... More
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe upto 100 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed by Engineer-in-Charge.Note : The rate of Galvanised steel light grade pipe upto 100 mm dia is paid seprately under appropriate item of schedule of works

24

-

-

... More
Supply and laying or fixing in replacement GI tubing light grade 40 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers complete fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench all as specified and directed by Engineer-in charge .

40

-

-

... More
All as per sreial item No. 22 above but for GI pipe of 50 mm bore light grade.

30

-

-

... More
All as per sreial item No. 22 above but for GI pipe of 80 mm bore light grade.

30

-

-

... More
All as per sreial item No. 22 above but for GI pipe of 100 mm bore light grade.

30

-

-

... More
Demolitiong of old earth pit and Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 25mm X 4 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI medium grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.

20

-

-

... More
Material & labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using 25mm x 4mm GI strip complete all as specified and as directed by Engineer-in-charge.

100

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 630 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 35/36 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

4

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 400 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 35/36 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

6

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 250 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 25 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

10

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 200 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 25 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

12

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 100 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 25 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

20

-

-

... More
Supply and fixing in replacement MCCB, 3 phase, 4 pole, 415 volt of capacity 63 Amp, short circuit, shunt trip coil with contactor, breaking capacity not less than 25 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and as directed by Engineer-in-charge .

15

-

-

... More
Supply and fixing in replacement MCB suitable for 415 volts AC supply, 63 Amps, Four Pole 'C' series with over load and short circuit protection and rupturing capacity not less than 9/10 KA. Complete all as specified and as directed by Engineer-in-Charge.

35

-

-

... More
Note:- The contractor shall deposited the old material retrived from item no 01 to 40 to AGE E/M Electric Supply store yard and shall maintain the record for the same.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.