Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Electrical Works
Eprocure
Opening Date10 Dec 2024
Closing Soon30 Dec 2024
Tender Amount₹ 49,93,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removal of excavated surplus spoil to a distance n. exc. 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.

215

-

-

... More
M&L for Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified and directed. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.

150

-

-

... More
Brick protection with pulverized fuel ash lime bricks laid flat across the route of underground cable all as specified.

16000

-

-

... More
M&L for Boring holes under road pavement / hardstanding by trenchless technology using ultrasound technique and necessary machine for inserting & including 75-100mm bore HDPE pipe complete all as specified and directed.

225

-

-

... More
GI pipe light grade with all fittings fixed as termination postal ,fixed to poles/ walls/ under floors/ under road etc including taking down existing pipe complete all as specified of following size: -

-

-

-

... More
50 mm bore

25

-

-

... More
80mm bore

45

-

-

... More
150mm bore

15

-

-

... More
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable complete all as specified, of following description: -

-

-

-

... More
35 Sq.mm, 3.5 core

125

-

-

... More
50Sq.mm, 4 core

225

-

-

... More
70 Sq.mm, 4 core

550

-

-

... More
95 Sq.mm, 4 core

750

-

-

... More
120 Sq.mm, 3.5 core

225

-

-

... More
NOTE:- Excavation and earth work, brick protection and sand cushning will be measured & paid separatly under respective item of BoQ)

-

-

-

... More
S&F, MCCB 4 Pole 100 Amps, 415 Volts , 50 Hz , 16 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed.

17

-

-

... More
S&F, MCCB 4 Pole 160 Amp, 415 Volts ,50 Hz , 36 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed

7

-

-

... More
S&F, MCCB 4 Pole 200 Amp, 415 Volts ,50 Hz , 36 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed

7

-

-

... More
S&F, MCCB 4 Pole 250 Amp, 415 Volts ,50 Hz , 36 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed

4

-

-

... More
S&F, MCCB 4 Pole 400 Amp, 415 Volts ,50 Hz , 36 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed

5

-

-

... More
S&F, MCCB 4 Pole 630 Amp, 415 Volts ,50 Hz , 50 KA adjustable thermal release range including all connections and testing IN REPAIRS, complate all as specified and directed

2

-

-

... More
Dismantling and Removing of old un used 11 KV OH line PCC/RCC/ poles 11 Meter long from existing place and throw the same within 5 km radius complete all as specified and directed .

25

-

-

... More
Dismantling and Removing of old un used 11 KV OH line steel tubular poles 11 Meter long from existing place and throw the same within 5 km radius complete all as specified and directed .

20

-

-

... More
REPAIR TO SOLAR LIGHTS UPS SPs APFC PANEL, VOLTAGE STABLIZER

-

-

-

... More
Servicing, cleaning and repairing by dismantling and taking out Air Circuit Breaker of capacity 400/630/800 amps, 3 pole 415 volts 50 Hz of any make and removing mechanical assembly fixed and moving contact set and replacing unserviceable mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed by Engineer in charge NOTE :- Replacement of unserviceable items/parts shall be measured & Paid for separately under respective items of BOQ.

20

-

-

... More
Replacement of unserviceable spare parts with new parts as per existing sample/size/make for ACU complete for the following :-

-

-

-

... More
S&F, Contact Assembly for 400 Amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

4

-

-

... More
S&F, Contact Assembly for 630/800 Amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

5

-

-

... More
S&F, Moving Contact Assembly for 400 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

4

-

-

... More
S&F, Moving Contact Assembly for 630/800 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

5

-

-

... More
S&F, Pole Assembly for 400 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

4

-

-

... More
S&F, Pole Assembly for 630/800 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

6

-

-

... More
S&F, Arc chute for 400 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

3

-

-

... More
S&F, Arc chute for 630/800 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

5

-

-

... More
S&F, Spring Charging Motor for 400 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

4

-

-

... More
S&F, Spring Charging Motor for 630/800 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

4

-

-

... More
S&F Control Relay for spring charging motor for 400 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed..

4

-

-

... More
S&F, Control Relay for spring charging motor for 630/800 amps 3 pole 415 volts ACB of exisiting make IN REPAIRS all as specified and as directed.

6

-

-

... More
M&L for Online Centrifuging (filteration/dehydration) of transformer oil including checking initial and after filteration Dielectric Strength of oil for transformers, Isolation transformers and voltage stabilizers located in various places of technical and domestic area with suitable machine having filteration, heating and pumping facility to improve the dielectric strength/insulation value of oil. Note :- (i) Di electric strength of oil after filteration/dehydration shall not be less than 60 KV at 2.5 mm gap. (ii) Oil for toping up shall be measured and paid separately under relevant item of this schedule (iii) The contractor will take shut down orders in writing atleast two days before from Engr-in-charge before commencement of work. (iv) The dielectric strength of oil shall be tested before and after filtration and necessary test certificates shall be submitted to the Engr-in-chaerge.. (v) Oil filteration machine with all T&P & testing equipment required for filtration to be arranged by contractor without any extra cost to the department.

5000

-

-

... More
Supply & topping up of new transformer oil conforming to IS-335/1983 for transformer/VL unit/Isolation transformer/Servo Voltage Stabilizer, up to the marked level all as specified & as directed by Engr-in-charge Note: (i) Mineral oil grade shall be used. (ii) The transformer oil should have a IR value of the oil should not less than 60KV/Min (iii) The quoted rate shall be deemed to cost of filtration and testing etc

200

-

-

... More
Supply and fix the silica Gel container (breather) including silica Gel suitable for the isolation transformers/servo controlled voltage stabilizer of capacity 50 KVA to 200 KVA after dismantling the old U/S breather complete all as specified and directed.

15

-

-

... More
Repair and maintenance of Solar street light LED fittings of any type and capacity including cleaning of perplex cover where ever required and tightening of loose connection or brought it down for repair and fix it back after repair on the pole/Building all complete all as specified and as directed by Engr-in-Charge.

20

-

-

... More
Cleaning and washing of each solar street light panel once in a month to remove layer of dust and dirt from panels by simply wash the panel with water and rub the panel surface with a sponge. Note : (a) Do not use a metal grush or detergent to clean the solar panel surface. (b) The contract period is six months, hence each panel will be cleaned and washed six time and will be measured as one job. (c) Rates deemed to be inculded labour, water and sponge charges.

50

-

-

... More
Supply and pour Battery Electrolyte (Distilled water with acid) once during contract period for solar batteries including checking the batteries all as specified and as directed.

25

-

-

... More
Supply & fix lead coated battery bolts & nuts suitable for solar batteries all as specified and directed.

10

-

-

... More
Dismantling the existing solar battery taking to the workshop for recharging the battery as per manufacturer instructions and bringing to the site and re-fixing the same as directed including testing of batteries for proper function with existing system complete all as specified and directed.

5

-

-

... More
S&F maintenance free sealed batteries of size 120 AH 12V including taking out old unservicealbe batteries all as specified and directed.

15

-

-

... More
Supply and fix in repair LED Street light fitting 10/12W, DC suitable for solar street light with pressure die cast aluminium housing with heat reristant glass & IP 65 Protection better option for uniform distribution of light & including with all accessories fixing on pole/wall complete with necessary connection and all as specified and directed.

10

-

-

... More
M&L for fabrication of Rectangular box of size 59cmx26cmx45cm made from 3 mm thick GI sheet suitable to accommodate solar battery including locking arrangements, providing support at the bottom and necessary fixing arrangements to fix the box on the pole and applying two coats synthetic enamel paint over a coat of red oxide primer including write pole No as per existing all as specified and directed.

10

-

-

... More
Dismantling, shifting and refixing of solar street light pole incl fixture i.e solar street light fitting, battery including box from original place to other place within 5 km distance complete all as specified and directed by Engr-in-charge. Note : PCC and excavation for re-fixing shall be measured and paid separately.

10

-

-

... More
M&L for PVC insulated & sheathed stranded FRLSH copper conductor three core cable 1100 Volts of size 2.5 sq. mm ( nominal area) conforming to IS 694 for making connection from junction box to light fittings IN REPLACEMENT complete all as specified.

90

-

-

... More
S&F Aviation obstruction light LED comprising aluminium housing with poly carbonate enclosure, 302 members LED are provided IN REPLACEMENT complete all as specified and as directed by Engr-in-Charge.

10

-

-

... More
M&L for repairing and testing of Servo Controlled Stabilizer capacity 10/20 KVA at reputed workshop including disconnecting the LT cables complete and taking out the core and checking the continuity and insulation value of coils for all three phases, inspecting and reinsulating coils if required, repair and, replacing the wornout parts if any, all as specified and as direcrted. Note : The rate shall also deemed to be included the rate for : (i) Technician, Electrician,and labours. (ii) Rewing of coils (iii) Minor spares/parts. (iv) Transportaion charges upto workshop and back.

5

-

-

... More
M & L for servicing of servo controlled volatge stabilizer of any make/type by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation values of all three phases, reinsulating if required and inspecting and replacing the PCB in case of repair, repair and servicing of breaker, removing and cleaning the sludge from the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 60 KV at 2.5 mm gap including testing of volatge stabilizer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted. (Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule) of following capacity:- Note : The rate shall also deemed to be included the rate for Technician, Electrician,and labours.

-

-

-

... More
30 to 75 KVA

4

-

-

... More
100 to 150 KVA

5

-

-

... More
M & L for servicing of Isolation transforners of of any make/type by disconnecting the LT cables and draining out oil complete and taking out the core and checking the continuity and insulation value of coils for all three phases, inspecting and reinsulating coils if required, repair and servicing of breaker, replacing the wornout parts if any, removing and cleaning the tank, refilling the oil after filtering by using online centrifuge machine and obtain the dielectric strength of oil not below 60KV incliuding testing of isolation transformer by reconnecting the disconnected cables and calibrating complete all as specified and as direcrted of following capacity. (Filtration of oil by using online centrifuge machine and top up of oil will be measured and paid separately under relevant items of the schedule) Note : The rate shall also deemed to be included the rate for Technician, Electrician,and labours.

-

-

-

... More
30 to 75 KVA

4

-

-

... More
100 to 150 KVA

5

-

-

... More
160 KVA

1

-

-

... More
750 KVA

1

-

-

... More
S&F in repair danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT, 25x20 cm size including taking down old unserviceable one. Note : The letters should be in English/Hindi and Punjabi language)

25

-

-

... More
M&L for Earthing IN REPLACEMENT complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32x6 mm (upto the cross arms) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.

5

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified, IN REPLACEMENT, with & including the following: -

-

-

-

... More
GI strip of size 32mm x6mm.

80

-

-

... More
NOTES: (a) Strips to be fixed with porcelain/polymer insulators at the intervals of 0.6 metre so as not to be in electrical contact with building structure. (b) Brazing shall be done on both sides (overlapping) at all joints except test point.

-

-

-

... More
M & L for PCC 1:4:8 type D2, 40mm graded aggregate as in foundation complete all as specified and as directed.

2

-

-

... More
M & L for PCC 1:3:6 type C1, 20mm graded aggregate for coping of poles etc incl dismantling of old coping all as specified and as directed.

20

-

-

... More
M & L for PCC 1:2:4 type B2, 40mm graded aggregate in foundaion complete all as specified and as directed.

1.25

-

-

... More
Fabricate, supply, installation, testing and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 100 KVAR (04 x 25 KVAR) with incoming MCCBs 250 Amps, 415 V, 50 Hz with breaking capacity 36 KA, heavy, duty capacitors with automatic monitoring of capacitor ON and OFF, ON & OFF push bottons, Selector switches. 400 Amps Copper busbar for long life and stability of the capacitors, made out of 2 mm thick CRCA Sheet, IP-56 protection, floor mounted, totaly enlosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands, with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1 foundation block, padestal of 30cm height from ground level with suitable nuts,bolts and washers etc. detachable plate shall be provided at the bottom of the panel with necessary holes suitable for termination of various sizes of cables with glands, suitable size copper wire for internal power and control wiring, hindged door at front with suitable locking arrangement, provision of air vent at both sides, both side openable CPRI approved, dust and vermin proof, powder coated complete. Make : Havells/L&T/Scheneider

2

-

-

... More
S&F, all in one Solar Street Light outdoor type with LED Street light 30 Watt, Solar panel of capacity not less than 50Wp, input Voltage 9V, IP-66 rating, cool white colour, 25 Hz, not less than 3900 lumens, CCT not less than 6000K, input current less than 2ma, efficiency not less than 90%, Battery 12 V and 18 Ah lithium ion, with 5 mtr long pole height IN REPAIRS compete all as specified and directed.

25

-

-

... More
S&F, Slow speed high torque synchronizing motor suitable for 25 KVA to 60 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed.

5

-

-

... More
S&F, Slow speed high torque synchronizing motor suitable for 75 KVA to 200 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed.

4

-

-

... More
S&F, Dimmer State complete with carbon brush and holder suitable for 25 KVA to 60 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed.

5

-

-

... More
S&F, Dimmer State complete with carbon brush and holder suitable for 75 KVA to 200 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed.

3

-

-

... More
S&F, PCB (Printed circuit board) plate electronic circuit 12 Pin suitable for 25 KVA to 60 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed.

5

-

-

... More
S&F, PCB (Printed circuit board) plate electronic circuit 12 Pin suitable for 75 KVA to 200 KVA capacity servo controlled voltage stabilizer IN REPAIRS complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Note : Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.