Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 99,700Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695879_1Tender No
8865/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR/MAINT UPS/SVRS AND APFC PANEL AND CONNECTED ACCESSORIES UNDER GE UTILITY BATHINDA
REPAIR/MAINT UPS/SVRS AND APFC PANEL AND CONNECTED ACCESSORIES UNDER GE UTILITY BATHINDA
REPAIR/MAINT UPS/SVRS AND APFC PANEL AND CONNECTED ACCESSORIES UNDER GE UTILITY BATHINDA
BOQ Items
... More
Supply only in replacement of Transformer suitable for 10 to 30 KVA UPS all as specified & directed by Engr-in- charge
10
-
-
... More
Supply only in replacement of IGBT suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in- charge
12
-
-
... More
Supply only in replacement of capacitor suitable for 2 to 30 KVA UPS all as specified & directed by Engr-in- charge
10
-
-
... More
Supply only in replacement of lead acid battery 12volt 42AH all as specified and directed by Engr-in charge
70
-
-
... More
Repair and Maintenance of APFC panel upto 300 KVAR rating by replacing defective parts i.e contactors, MCB, MCCBs, capacitors, relay, indication lamps, auto manual switch, push button, cooling fan, SMPS, CTs, relay junction point/ connector etc. and blowing of dust by air blower, repair of panel doors by providing hinges, locking arrangement or fixing of new door of existing size including checking the wiring of panel and connection of capacitor if found faulty replace with existing size of copper wire with complete testing of APFC relay including necessary setting with CTs load adjustment to match the power factor in range between 0.96 to 0.99.complete all as directed as specified by Engr in Charge.Note:- All unserveciable Items replaced under repair and servicing of APFC panel shall be measured and paid separately as "supply only" as described hereinafter in respective items
15
-
-
... More
Supply only of capacitor duty contactor heavy duty type 3 pole AC of capcity of 10 KVAR along with 1 No + 1 NC auxilary contact as directed
10
-
-
... More
Supply only of capacitor duty contactor heavy duty type AC of capcity of 15KVAR along with 1 No + 1 NC auxilary contact as directed
10
-
-
... More
Supply only capacitor duty contactor heavy duty type AC of capcity of 20 KVAR along with 1 No + 1 NC auxilary contact as directed
10
-
-
... More
Supply only of capacitor duty contactor heavy duty type AC of capcity of 25KVAR along with 1 No + 1 NC auxilary contact as directed
5
-
-
... More
Supply only of capacitor duty contactor heavy duty type AC of capcity of 5 KVAR along with 1 No + 1 NC auxilary contact as directed
5
-
-
... More
Supply only APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage for contactor type APFC panel and thyristor based APFC panel with 3 CT input all as specified and directed by engr-in charge
5
-
-
... More
Supply only cast resin type CT coil suitable for amp meter 200/5 amp ratio complete all as directed
3
-
-
... More
Supply only cast resin type CT coil suitable for amp meter 800/5 amp ratio complete all as directed
4
-
-
... More
Supply only cast resin type CT coil suitable for amp meter 400/5 amp ratio complete all as directed
4
-
-
... More
Supply only of MPP capacitor 440 volts 50 HZ electric complete of capacity 10 KVAR cyllindrical type gas filled as directed
10
-
-
... More
As per item no. 18 above but for rating 15KVAR.
5
-
-
... More
As per item no. 18 above but for rating 20KVAR.
5
-
-
... More
As per item no. 18 above but for rating 25KVAR.
5
-
-
... More
As per item no. 18 above but for rating 5KVAR.
7
-
-
... More
Supply only of indicating lamp RYB including connection for capacitors as directed
50
-
-
... More
Supply onlyof Auto manual switch for APFC panel as directed
10
-
-
... More
Supply only in replacement of MCCB 63Amp 3Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
10
-
-
... More
Supply only in replacement of MCCB 100Amp 3Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
10
-
-
... More
Supply only in replacement of MCCB 400Amp 4Pole, 415volt, 50 Hz 36ka adjustable type complete all as specified and directed by Engr-in charge
4
-
-
... More
Material and Labour for repairing the LT panel board body by replacing with new CRCA sheet of existing gauge size and shape for door / body of Pane/feeder pillar box, with hinjes and door lock should be well welded complete all as specified and as directed.
2
-
-
... More
Material and Labour for Preparation of old painted surfaces of feeder piller box / panel of any size any description and in any position including removel of faded & deteriorated paint either by hand scrubbing or by blow lamps , applying necessary filler coat and scrapping as required and applying two coats of synthetic enamelled paint (grey in colour) inside and outside of panel with using spray machine over a coat of primer complete all as specified and as directed.
15
-
-
... More
Supply, fixing, connecting and testing in replacement of APFC Panel of capacity 125 KVAR (Output) @ 440Vac. The stage ratings shall be 1x2 KVAR + 1x3 KVAR + 2X 5KVAR + 1X 10KVAR+ 2x25kvar + 1 x50 KVAR .The degree of protection of enclosures system of the APFC Panel shall be min. IP54. The APFC Panel shall be OEM made , machine pressed , dust and vermin proof , indoor type , Panel internally and externally shall be painted with expoxy powder coating paint & two coats primer, before being given the stove epoxy finish , both side opening in two halves with rubber beading.The panel mounted on angle iron frame and legs made from angle iron of size 40mm x 40mm x 5mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer , As equipment shall be comprising of the following:- Make:- Havells, Legrand, L&T
2
-
-
... More
Insulated bus bar pan assembly made from Copper suitably rated capacity.
-
-
-
... More
The incomer of the APFC Panel shall be a suitable rated, MCCB.
-
-
-
... More
Capacitor Units: The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In, operating losses less than 0.5W/KVAR and peak inrush current shall be 200x In.
-
-
-
... More
Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics= 36kA.
-
-
-
... More
PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 12 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port.
-
-
-
... More
Stage Contactor: The capacitor duty contactors shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks.
-
-
-
... More
Ventilating fans of required size shall be sued to dissipate the heat produced by the capacitor bank components like the capacitor units, contactors, breakers etc.
-
-
-
... More
Indication Lamp, Push button (Start and Stop) and Auto/Manual switch to be install for each stage of capacitor on Panel.
-
-
-
... More
As per item no. 30 above but for rating 100KVAR of stage 1x2 KVAR + 1x3 KVAR + 1X 5KVAR + 1X 10KVAR+ 4x20kvar
3
-
-
... More
As per item no. 30 above but for rating 75KVAR of stage 1x2 KVAR + 1x3 KVAR + 2X 5KVAR + 2X 10KVAR+ 2x20kvar
4
-
-
... More
As per item no. 30 above but for rating 50KVAR of stage 1x2 KVAR + 1x3 KVAR + 1X 7.5KVAR + 3X 12.5KVAR
4
-
-
... More
As per item no. 30 above but for rating 30KVAR of stage 1x2 KVAR + 1x3 KVAR + 3X 5KVAR + 1X 10KVAR
3
-
-
... More
Supply,Laying and testing in replacement of XLPE LT Cable of size 240 Sqmm, 3.5 core, 1100 Volt grade heavy duty with XLPE insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
40
-
-
... More
As per item no 35 but for cable size 185 Sqmm 3.5 core.
90
-
-
... More
Note: The contractor shall deposited the old material retrieved to AGE EM store yard by his own arrangement without any financial benefit and shall maintain the record for the same as specified by Engr-In-Charge and GE.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%