Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Nov 2024
Closing Date21 Feb 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Summary

Repair/ Replacement Of Security Lights/ Street Lights, Junction Boxes Including Connected E/m Items At East Of Mall Road Under Ge (east) Jalandhar Cantt

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 1 but here-in-before for 12.5 Mtr high mast lights/16 Mtr height mast light incl bringing down of high mast light bracket down to ground level by suitable means motor/manual,(as available at site) dismantling/repair the lights after replacement of parts, assembling/ re- fixing the lights and taking up the light bracket complete with the help of motor or any type of manual labour work incl any disconnection/ connection of of cables involved. Note: 1. The taking down of high mast light down, repair of one or more lights and taking up and fixing the bracket on top at one time will be measured as one unit for payment. 2. In case, lamp carriage cant't be taken/moved down due to problem in up/down movement mechanism, Contractor have to arrange suitable Hydra or any other arrangement to repair lights. Nothing extra shall be payable on this account. 3. The quoted rate includes cost of cutting/ pruning of shrub around high mast for easy repair of High Mast.

40

-

-

... More
S & F LED street light fitting 45 watts,made up of pressure die-cast aluminium housing with toughened glass/PC embedded lens with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy 100Lm/W min, overall 4500 lumens min, CCT 5700K ANSI, CRI70, THD10%, PF 0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off 300 V and with separate external Surge protection device 10 KV, suitable for fitting on 40 mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified. Note - The contractor shall ensure the light fitting dia should be suitable for 40 mm dia bore pipe. contractor shall quote his rate accordiangly.

80

-

-

... More
S & F LED street light fitting 60 watts,made up of pressure die-cast aluminium housing with toughened glass/PC embedded lens with Pressure Die Cast Aluminium Housing with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 100 Lm/W min, CCT 5700K ANSI, CRI70, THD10%, PF 0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off 300 V and with separate external Surge protection device 10 KV suitable for fitting on 40 mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified.

60

-

-

... More
Ditto as per item No 04 here-in-before but of capacity 70 W complete.

20

-

-

... More
Ditto as per item No 04 here-in-before but of capacity 90 W complete.

10

-

-

... More
S & F LED Flood light fitting 150 watts,made up of pressure die-cast aluminium housing with toughened glass with mandatory secondary optics lenses, with SS screws, IP-66, luminaire efficacy more than 100 Lm/W, CCT 5700K ANSI, CRI70, THD10%, PF 0.95, LED source : Hi power LED 3 to 5W High power type .Fitting should be double driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off 300 V and separte Surge protection device 10 KV complete having fixing bracket clamp.

25

-

-

... More
Ditto as per item No 7 above but of capacity LED light Fitting 70 Watt. Note :- (i) The old unserviceable LED fitting shall be issued by JE incharge after deducting amount as per Sch of credit at the time of RAR. (ii) The old unserviceable light fitting may be of lower wattage/ old specification, no claim will be entertained on this account.

12

-

-

... More
S&F in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit , voltage band 150 volts to 270 volt (min), Efficacy 100 lm/W power factor 0.90 suitable for compartment of existing LED street light of capacity 42W to 45 W complete all as specified and directed. Note: i) Make for item S No 9 to 14 : OSRAM/PHILIPS/POLYCAB/CROMPTON/ SURYA /BAJAJ/ ORIENT/ HAVELLS/KCSAD/ GE or equivallent as approved by GE. (ii) The contractor shall have to procure the suitable driver of compact size to ensure easily fit for exising LED light fittings,No claim of contractor will be entertaint on this account.

200

-

-

... More
Ditto as per item No 09 above but of capacity 30 W.

9

-

-

... More
Ditto as per item No 09 above but of capacity 60 W.

100

-

-

... More
Ditto as per item No 09 above but of capacity 70/72 W.

80

-

-

... More
Ditto as per item No 09 above but of capacity 90/100 W.

80

-

-

... More
Ditto as per item No 09 above but of capacity 120/150 W.

40

-

-

... More
S & F SPD 10 KV min (surge Protection Device) suitable for street light / Flood light fitting for avoid surge protection voltage upto all as specified and directed by Engineer -in -Charge.

450

-

-

... More
Supply and fixing in replacement 3 pole contactors 40 Amps with coil voltage 240 Volts suitable for timer panels. Make BCH or equivalent in ABB/L&T/ Siemens/Schneider

8

-

-

... More
M&L for Astro timer of rating 20 Amp to replace existing unserviceable timer incl necessary connections complete all as specified and directed. Make- Siemens/ L&T/ Legrand/Havells/ABB

8

-

-

... More
Supply & Fix Astronomical Digital timer switch for switching on/off lights according to rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed preset time, current capacity 16A, weekly program with 1 changeover (1 CO), Total 28 programs min complete in powder coated CRCA sheet enclosure of suitable thickness with MCB TPN 32 Amp min, 3 pole contactor 32 Amp and MCB for manual switching of lights, fixing arrangement i.e. DIN rail complete with necessary porcelain insulator for incoming and outgoing cable connections with reqd clamp duly painted to fix on pole complete all as specified and directed. Make of timer switch : Indoasian / Siemens /Schneider/ L&T/ Legrand/Havells/GIC

2

-

-

... More
S&F junction box complete with fixing accessories. The Junction Box shall be insulated and made out of Polycarbonate/Thermoplastic with glass fiber reinforced. The Polycarbonate J. Box shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The Junction Box Minimum Size 160 x 200 x 98mm minimum. The Junction Box with Knock out on four side wall. The Junction Box shall be rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998-1& IEC 60998-2-1, with one number 10 Amp MCB SP 10KA. Make :- Cat Part No. KM 9250 Hensel,/ Schneider/GE Power/ABB or euivallent as approved by GE.

60

-

-

... More
Supply and fixing in replacement bracket made out of 40 mm dia bore GI pipe light grade tubing 1.2 metre long, and bent to shape at 120 degree angle with reqd holes for passing connection cable, fixed with clamps nuts and bolts, washer complete all as specified . (Clamps, nut, bolts and washers will be measured and paid separately).

30

-

-

... More
Supply and fixing in replacement MCB C-Curve, 10 KA, SP 10 to 32 Amp, 240 volts including taking down the exiting unsserviciable MCB and all the necessary electrical connections, all as specified and directed .

40

-

-

... More
Supply and fixing in replacement MCB 10 KA, SPN 40 Amp, 240 volts including taking down the exiting unsserviciable MCB and all the necessary electrical connections, all as specified and directed .

25

-

-

... More
S & F in replacement MCCB 63 Amps, 4 pole, 16 kA with fixed thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand /Siemens/schneider/ABB

3

-

-

... More
S & F in replacement MCCB 100 Amps, 4 pole, 16 kA with fixed thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand /Siemens/schneider/ABB

3

-

-

... More
S & F in replacement MCCB 160 Amps, 4 pole, 25 kA with Adjustable thermal fixed magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand /Siemens/schneider/ABB

3

-

-

... More
S & F in replacement MCCB 200 Amps, 4 pole, 25 kA with Thermal magnetic release, Ics = 100% Icu , 415 volts, 50 Hz with phase barrier/phase seperator/spacer with copper spreader links and required nut, bolts or other fixing accessories complete. Make: Legrand /Siemens/schneider/ABB

3

-

-

... More
Material and labour for locating fault of LT underground cables of size 10 Sqmm to 35 Sqmm 3.5 core/4 core laid in trenches by excavating (upto 10 mtr of length) the faulty portion of cable, taking out protection bricks or cover, sand and faulty cable for repair to cable, making of joints or repair to existing joint including all jointing material such as LT joint, ferrule and relaying after repair including refiling of sand and relaying of brick protection cover complete all as specified and directed. Notes : New LT joint will be measured and paid separately. The rates quoted includes cost of earth work i.e. excavation, returning, filling, renoving etc.

50

-

-

... More
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 25 -35 sqmm 3.5 core.

5

-

-

... More
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 50-70 sqmm 3.5 core.

10

-

-

... More
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 95-120 sqmm 3.5 core.

5

-

-

... More
Supply and fix heat shrinkable straight through joint suitable for 1100 V XLPE/ PVC cable of size 150-185 sqmm 3.5 core.

1

-

-

... More
M & L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI Pipe up to 100mm mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. (Note: The GI pipe shall be measured and paid separately.)

30

-

-

... More
S & F 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed .

12

-

-

... More
Supply and fixing galvanised pipe light grade (IS-1239) 80 mm bore for passing of cable fixed to poles/walls/laid under floor/ road/ hardstanding complete with and including fittings as required compete all as specified and directed Engr-in-charge.

12

-

-

... More
Supply and fixing galvanised pipe light grade (IS-1239) 100 mm bore for passing of cable fixed to poles/walls/laid under floor/ road/ hardstanding complete with and including fittings as required compete all as specified and directed Engr-in-charge.

10

-

-

... More
M & L for preperation of old painted surface of PCC LT poles and applying two coats of synthetic enamel paint in alternate black & white strips of 30 cm width up to 1.5 mtr height from top of PCC coping and numbering of poles in min 10cm height with black colour paint complete all as specified & directed by Engineer-in-charge

200

-

-

... More
M & L for preparation of old painted surface of street Light bracket, clamp and nut bolt etc with one coat of aluminium oxide paint complete all as specified & directed by Engineer-in-charge.

200

-

-

... More
M & L only for cutting / Pruning of trees branches upto 2 mtr all around the LT overhead lines of span not exceeding 50 mtr and around the pole obstructing the overhead line & removing/ disposing the branches to a distance not exceeding 200 mtrs to the entire satisfaction of Engineer-in-Charge. Note – The rate quoted include any type of T & P i.e. ladder,cutting machine,cutting axe/ Tools etc required at site.

280

-

-

... More
Restretching of existing loose OH, LT ACSR conductor wire span any type/ any supply including GI wire along the span of pole having 2 to 6 wire for sagging within the permissible limit, including disconnecting cable connections, opening of binding wire, winding/ rewinding/joining with aluminium winding wire in case of breakage of conductor and restringing at same place as same phase or changing the location to use as neutral or other phase complete as directed and again fixing to insulators with binding wire and making outgoing electric cable connections. The Size of binding wire of same size as made up of conductor complete all as specified and directed by Engr in charge. Note : (i) Nothing extra is admissible on account of jointing material and labour in case the conductor breaks during stretching. (ii) Cutting trimming of hanging/extended branches of trees upto a distrance 2 mtr from/ over the overhead HT/LT line and making the line clear upto the entire length of the restretched ACSR feeder including removal and disposing of the cut tree/branches 200 mtr away for the site as directed is deemed to be included in the quoted rate. (iii) Piece of conductor of suitable size required for connecting the broken conductor to make joint shall deemed to be included in the rates quoted by the contractor. (iv) All number Qty of ACSR conductor incl earth wire in a span shall be measured as a one unit only for measurement and payment purpose.

300

-

-

... More
M & L for preperation of old painted surface of steel tubular poles 9/11 meter long with one coat of aluminium oxide paint complete & numbering of poles in black colur all as specified & directed by Engineer-in-charge.

150

-

-

... More
S & Fixing in replacement Aluminium thimbles suitable for 35 to 50 Sqmm UG cable, crimping and connecting with MCCB/ ACSR complete incl disconnecting cables and making necessary connections after fixing thimble all as specified and directed.

100

-

-

... More
S & Fixing in replacement Aluminium thimbles suitable for 70 to 95 Sqmm UG cable, crimping and connecting with MCCB/ ACSR complete incl disconnecting cables and making necessary connections after fixing thimble all as specified and directed.

100

-

-

... More
S & Fixing in replacement Aluminium thimbles suitable for 120 to 150 Sqmm UG cable, crimping and connecting with MCCB/ ACSR complete incl disconnecting cables and making necessary connections after fixing thimble all as specified and directed.

80

-

-

... More
Disconnecting LT cable of size 35 Sqmm to 95 Sqmm any type from Panel/Pole/ Junction box by disconnecting cable and taking out loop and refixing and making cable connections with fixing of thimbles/ lugs of proper size incl any type of excavation work involved as directed by Engr-in Charge. Note: The thimbles shall be measured under relevant items separately.

50

-

-

... More
M&L for painting of cross arms 0.60 mtr long with clamps in position on 9/11 Mtr long pole with two coat of aluminium oxide incl preperation of old painted surface complete all as specified & directed.

120

-

-

... More
Disconnecting XLPE/PVC insulated armoured aluminium conductor cable connection fom ACSR, removing from the pole and S&F end termination outdoor heat shrinkable joint suitable for 35 to 50 Sqmm,3.5/ 4 core PVC/XLPE cable and refixing the cable along with pole and making the connection with ACSR conductor complete all as specified & directed. Note: The rate also include the cost for removing of loop from ground after necessary excavation and stretching out the loop and necessary earth work to take out and burry the loop of cable.

22

-

-

... More
M&L Replacement of PVC insulated PVC sheathed copper conductor cabe of 0.75 Sqmm, 3 core complete for street light and making connections all as specified and directed.

500

-

-

... More
Takign down ACSR of any type and any size by opening binding wires, removing outgoing electric connections by opening cable connections, removing spacers as directed by Engr-in-Charge. Note: The decision of Engr-in-charge will be final and binding regarding the no of spans/ length and no. of phase or neutral conductors to be removed/ taken down from site.

3

-

-

... More
Supply and fixing aluminium conductor steel reinforced of size ferret/ mink or other size required at site in required length/ span for overhead lines on poles stretching/ stringing without kinks and bends, including fixing with insulators using aluminium binding wire (rates inclusive), jumpers, line tapes etc and making necessary outgoing cable connection etc complete all as specified and directed.

3

-

-

... More
Dismantling insulators any type, any size complete with opening of ACSR binding wire complete all as specified and directed

90

-

-

... More
Supply and fixing pin type insulator 100mm height, 65mm dia for 1100 volts grade porcelain vitreous white, brown or green including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nuts complete all as specified

20

-

-

... More
Supply and fixing in replacement shackle type insulator pressure porcelain vitreous white, brown or green insulator for 1100 volts grade complete all as specified and directed.

60

-

-

... More
Supply and fixing in replacement loop type insulator porcelain vitreous white or brown, for LT stay large size with overall dissensions 65x140 mm, clearance hole 20mm for 1100 volts grade complete all as specified.

10

-

-

... More
Supply and fixing in replacement MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer including dismantling/ taking down existing MS work complete all as specified and directed. Note: Unexposed surface shall be given one coat of primer only.

1.5

-

-

... More
Dismantling damaged concrete poles/ struts/ steel poles upto 11m height complete with necessary excavation work, dismantling/ demolition of RCC foundation/ coping and removing complete of any size, height and shifting for taking credit all as specified and directed.

15

-

-

... More
Supplying, erecting and fixing Pressed concrete poles 09 meter long 102 x 172 at top and 102 x 279 mm at bottom class 10 complete as specified including painting of poles upto 1.5 mtr height from coping with two coats of synthetic enamel paint black & white strips and numbering of poles as directed complete all as specified and directed. (PCC and earth work shall be measured & paid for separately).

15

-

-

... More
Material & Labour for PCC work (1:3:6) type C-2 using 40 mm graded aggregate in foundation of electric stay, etc. including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified.

5

-

-

... More
Material & Labour for PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric pole, etc. including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified.

11

-

-

... More
M&L for Stay assembly complete with accessories as shown in electrical plate No. 1 including loop type insulator large size, stay clamps, stay plate 230x230x6mm complete. Note- Excavation and Concrete shall be measured and paid separately.

8

-

-

... More
M&L for Galvanised steel wire stranded 7/2.24 mm or 7/1.6mm incl fixing complete.

0.4

-

-

... More
Supply & fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 6 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed.

600

-

-

... More
Supply & fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 10 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed.

600

-

-

... More
Supply & fixing 1100 volts grade heavy duty PVC insulated & PVC sheathed stranded aluminium conductor of size 16 sqmm twin core flat cable in service incl Taking down/ out unserviceable conductor connection all as directed.

400

-

-

... More
Supply and fixing wall/ Pole mounted bus bar chamber with copper bus bar current rating 250 Amp - 4 Nos (rating based on 1.5 Amp/ Sqmm) suitable for 415 volt 50 Hz AC supply complete making all incoming and outgoing connections in CRCA powder coated steel enclosure of made of 3mm thick sheet size 600mm x 400mm x 300 mm complete incl one MCCB 4 Pole,200 Amp with phase barrier, phase extenders/spreader links with fixing clamp all as directed by Engr- in - charge.

1

-

-

... More
Supply and fixing wall/ Pole mounted bus bar chamber with copper bus bar current rating 160 Amp - 4 Nos (rating based on 1.5 Amp/ Sqmm) suitable for 415 volt 50 Hz AC supply complete making all incoming and outgoing connections in CRCA powder coated steel enclosure of made of 3mm thick sheet size 600mm x 400mm x300 mm complete incl one MCCB 4 Pole,100 Amp with phase extenders/spreader with fixing clamp all as directed by Engr- in - charge.

2

-

-

... More
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth strip 32x6 mm as earthing strip by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth strip protected by 40mm dia GI light grade pipe (IS-1239), PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. (Note: The rate quoted include the cost of GI strip & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner . (2) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.

3

-

-

... More
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thickness buried directly in ground (earth pit not less than 2.25meters deep below ground level) with top edge of the plate not less than 1.5meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of GI bolts, nuts, check nuts and washers incl surrounded on all sides by 15cm thick layer of charcoal dust, salt, incl earth wire protected by 15 mm dia GI light grade pipe (IS-1239), PCC pit of 1:2:4 & reinforced PCC top cover 50mm thick, earth pit angle frame of size 25mmx25mmx3mm with excavation and earth work in any type of soil, light grade GI watering pipe 20mm dia with funnel and wire-mesh complete all to as shown in electrical plate no 3 of SSR Part I 2009 connected main switch board or as reqd at site all as specified and testing on completion. Note: The rate quoted include the cost of wire & GI protection pipe light 40mm dia bore light grade upto 7.5 metres. PCC Chamber shall be constructed at least 0.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner . (2) If the results are not found satisfactory, then 2nd earthing will be re-done without any cost payable to Contractor.

2

-

-

... More
M&L for Jointing of snapped/broken ACSR any type by opening disconnecting of outgoing cable connections complete incl opening of binding wires, jointing of snapped ACSR by using new Aluminium conductor of same type, re-stretching/re- stringing of ACSR from one side dead end point (any length) for permissible sag and fixing to insulators with binding wire and incl making connection of outgoing cables complete. Note -(i) The jointing & restretching/re-stringingof one ACSR wire shall be measured as one unit only. (ii) Cutting trimming of hanging/extended branches of trees upto a distrance 2 mtr from the orver head LT line and making the line clear upto the entire length of the restretched ACSR including removal and disposing of the cut tree/branches 200 mtr away for the site as directed is deemed to be included in the quoted rate. (iii) Piece of conductor of suitable size required for connecting the broken conductor deemed to be included in the rates quoted by the contractor.

70

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge. Note:- The quoted rate include any type of cost for removing shrubs to clear site to start excavation

395.12

-

-

... More
Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge.

203

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.

192.12

-

-

... More
Material and labour for sand cushioning with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable and trenches punned down to thickness of 18 cm complete all as specified and directed.(Note: Punned thickness of 18 cm will be measured and paid)

140

-

-

... More
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.

13.12

-

-

... More
Taking down/ out unserviceable UG cables of any cross sectional area, any type, any make from trench/ from wall/pole/pulling through pipe by opening connections and joints including removing pipe, bricks etc of any description from trenches or fixed with walls/ poles, segregating serviceable bricks/ cable cover, cables etc and keep in safe custody for reuse, complete all as specified and directed. Note : Earthwork shall be measured and paid under appropriate items of BOQ.

3790

-

-

... More
Supply, laying, jointing and testing XLPE insulated, PVC sheathed , steel strip or wire armoured electric cable 1100 volt grade (heavy duty) with stranded aluminium conductor of size 10 Sqmm, 2 core laid in trenches, in floor, in duct, through pipes/ culvert or along the pole/wall under roads complete all as specified and directed

700

-

-

... More
All as per item No. 75.00 here-in-before but of size 6 Sqmm 2 core

700

-

-

... More
All as per item No. 75.00 here-in-before but of size 10 Sqmm 4 core

800

-

-

... More
All as per item No. 75.00 here-in-before but of size 25 Sqmm 3½ core

400

-

-

... More
All as per item No. 75.00 here-in-before but of size 50 Sqmm 3½ core

340

-

-

... More
All as per item No. 75.00 here-in-before but of size 95 Sqmm 3½ core

300

-

-

... More
All as per item No. 75.00 here-in-before but of size 150 Sqmm 3½ core

350

-

-

... More
All as per item No. 75.00 here-in-before but of size 185 Sqmm 3½ core

200

-

-

... More
M&L for load balancing & current leakage problem on LT feeder complete for One No transformer rating upto 315 kVA compete by deploying Electrician and helpers team with necessary team to check existing load on all three phase, leakage current voltage and balancing the load all three phase incl detecting and removing phase earth, current leakage, short circuit problem due to ACSR on MS D clamp, cable short, short ACSR or any other reason complete. Note: The parts replaced to remove any short circuit shall be measured & paid separately under relevant item of Sch.

10

-

-

... More
M& L for Cutting chases in road/ hardstanding upto depth of 100mm to 150 mm min holes in or through walls /earth surface for inserting GI/HDPE Pipe up to 100mm bore mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge. (Note: The GI/HDPE pipe shall be measured and paid separately.)

10

-

-

... More
M & L for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE LT underground power cables of the rating 11 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of faut location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar cantt all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed by Engr-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly.NOTE: Fault should be detected and rectified within 24 hrs from intimation to contractor. If contractor fails to rectify fault withing 24 hurs thean after 24 hours a penalty should be levied to contractor at the rate of Rs 2000 per hour in case of dealy.

8

-

-

... More
Re-laying old size sub class 'B' bricks retrieved during taking out old cable, which shall be laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
M&L numbering of poles complete with neat & clean way with stencil & paint of approved colour as directed by deptt complete. The height of numbers, alphabet shall be min 120 mm.

400

-

-

... More
M&L for DWC (double wall corrugated) pipe IS 16205 in suitable colour of size 40 mm OD SN8 class complete all as specified & directed.

40

-

-

... More
M&L for DWC (double wall corrugated) pipe IS 16205 in suitable colour of size 63 mm Min OD SN8 class complete all as specified & directed.

20

-

-

... More
Supply and fixing butt hinges, heavyweight, cold rolled mild steel of size 125 mm and fixed properly on MS sheet of thickness 2 to 3.15 mm after dismantling old one from panel and fixing panel door on other side and necessary painting to disturbed surface complete all as directed. (Note: panel door shall be measured and paint separately)

12

-

-

... More
Material and labour for stainless steel sliding door bolts, plate type, stainless steel finish, with bright bolt not less than 12mm dia, length 250mm with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete to LT panel door with welding or suitable means all as directed.

6

-

-

... More
Material and labour for fixing of MS CRCA sheet powder coated of 2 to 3.15mm thickness , cut to shape and size required as per LT panel located at site including welding of hinge joint to sheet for fixing incl making good distributed surfaces spray by a painting complete all as per directed by Engineer-in-Charge Note:- Hinge shall be measured and paid separetely.

160

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.