Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 3,74,500Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688824_1Tender No
81016/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(v) Pump House No.26 :-
(a) Submersible pumpset 15 HP - 01 No
(b) Over head tank Reservoir 50000 Gallon,21.3 Mtr (Staging) - 01 No
(c) Rising and distribution pipe line- 100 mm(Rising) and 100mm (Delivery)
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No (vi) Pump House No.30 :-
(a) Submersible pumpset 15 HP - 01 No
(b) Over head tank Reservoir 25000 Gallon,21.3 Mtr (Staging) - 01 No
(c) Rising and distribution pipe line- 150 mm(Rising) and 100mm (Delivery) (d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(vii) Pump House No.01 :-
(a) Submersible pumpset 45 HP - 01 No and submerssible pump set 15 HP-01 No
(b) Over head tank Reservoir 50000 Gallon,18 Mtr (Staging) - 01 No and under ground sump 25000 Gallon - 01 No
(c) Rising and distribution pipe line- 150 mm (Rising), 150mm (Delivery of OHT) and 100mm (Delivery of UG sump) (d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
-
-
-
... More
(viii) Pump House No 38 :- (a) Submersible pumpset 30 HP - 01 No (b) Over head tank Reservoir 50000 Gallon,21.3 Mtr (Staging) - 01 No (c) Rising and distribution pipe line- 150 mm(Rising) and 150mm (Delivery) (d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(ix) Pump House No.23:-
(a) Submersible pumpset 25 HP - 01 No
(b) Over head tank Reservoir 50000 Gallon,21.3 Mtr (Staging) - 01 No
(c) Rising and distribution pipe line- 150 mm(Rising) and 150mm (Delivery)
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(x) Pump House No.24 :-
(a) Submersible pumpset 30 HP - 01 No
(b) Over head tank Reservoir 100000 Gallon,21.3 Mtr (Staging) - 01 No
(c) Rising and distribution pipe line- 150 mm(Rising) and 150mm (Delivery) (d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(xi) Pump House No.31 :- (a) Submersible pumpset 25 HP - 01 No
(b) Over head tank Reservoir 100000 Gallon,21.3 Mtr (Staging) - 01 No
(c) Rising and distribution pipe line- 150 mm(Rising) and 150mm (Delivery)
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(xii) Pump House No.02 :-
(a) Submersible pumpset 45 HP - 01 No
(b) Over head tank Reservoir 50000 Gallon,18 Mtr & 12 Mtr (Staging) - 02 Nos
(c) Rising and distribution pipe line- 150 mm(Rising) - 02 Nos and 150mm (Delivery) - 02 Nos
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
-
-
-
... More
(xiii) Pump House No.04 :-
(a) Submersible pumpset 45 HP - 01 No
(b) Over head tank Reservoir 50000 Gallon,15 Mtr & 21.3 Mtr (Staging) - 02 Nos
(c) Rising and distribution pipe line- 150 mm(Rising) - 02 Nos and 150mm (Delivery) - 02 Nos
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(xiv) Pump House No.05 :-
(a) Submersible pumpset 45 HP - 01 No
(b) Over head tank Reservoir 100000 Gallon, 12 Mtr (Staging) - 02 Nos
(c) Rising and distribution pipe line- 150 mm(Rising) - 02 Nos and 150mm (Delivery) - 02 Nos
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
(xv) Pump House No.19:-
(a) Submersible pumpset 30 HP - 01 No
(b) Over head tank Reservoir 70000 Gallon, 21.3 Mtr (Staging) - 02 Nos
(c) Rising and distribution pipe line- 150 mm(Rising) - 02 Nos and 150mm (Delivery) - 02 Nos
(d) Chemical dosing system Pressure 4 Kg/Sqcm, 35 LPH - 01 No
-
-
-
... More
Taking down carefully old sluice valves of size 100/150 mm all as specified and directed.
40
-
-
... More
Operate SCADA system during defect liability period of two years (contractor to provide month-wise breakdown details of same, No manning or deployment of manpower required).
24
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for first year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for second year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for third year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for fourth year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for fifth year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for sixth year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for seventh year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
... More
Operation and comprehensive maintenance of SCADA system including cost of upgradation cost of spares for eighth year post defect liability period, operation including payment of bills by telecom service provider (contractor to provide month-wise breakdown details of same)
12
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%