Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date23 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 49,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
COMPREHENSIVE MAINT/DAY TO DAY COMPLAINTS OF DESERT COOLER, REFRIGERATOR, DEEP FRIDGER AND VOLTAGE STABILIZER OF ZONE A AT BATHINDA UNDER GE UTILITY BATHINDA
Comprehensive maint/day to day complaints of desert cooler, refrigerator, deep fridger and voltage stabilizer of zone A at Bathinda under GE Utility Bathinda
Comprehensive maint/day to day complaints of desert cooler, refrigerator, deep fridger and voltage stabilizer of zone A at Bathinda under GE Utility Bathinda
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type of capacity 2 Ton, any make & type including Supply and Fixing New Rotary Compressor of air conditioner of window Type / Split type of cap 2 Ton along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed. Make : Hitachi / Tecumseh / GMCC.

10

-

-

... More
All as per srl item No 04 above but for Window Type / Split type AC of capacity 1.5 Ton. Make : Hitachi / Tecumseh / GMCC.

20

-

-

... More
All as per srl item No 04 above but for Reciprocatory Compressor window Type / Split type of 1.50 Ton Make : Hitachi / Tecumseh / GMCC.

5

-

-

... More
All as per srl item No 04 above but for Reciprocatory Compressor AC Window Type / Split type of cap 2.00 Ton Make : Hitachi / Tecumseh / GMCC.

3

-

-

... More
All as per srl item No 04 above but for Rotary Compressor from Cassate Type Air Conditioner of cap 4.00 Ton Make :Daikin/Blue Star/ Voltas. Note for serial item No. 04 to 08 :- (i)The cost of new foundation rubber pads, nut and bolts are included in this item and nothing shall be paid extra on this account. (ii)The cost of gas and charging the gas is also included in this item and nothing shall be paid extra on this account.

1

-

-

... More
Supply and fixing in repair Fan motor of existing size and make for cassate type Air Conditioner complete all as directed.

1

-

-

... More
Supply and Fixing in repair Drain motor of existing size and make for cassate type Air Conditioner complete all as directed.

1

-

-

... More
Supply and Fixing in repair Fan motor of make existing suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.

25

-

-

... More
Supply and Fixing in repair Fan Blade Metalic (aluminium) suitable for Window Type / Split Type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.

25

-

-

... More
Supply and Fixing in repair Running Capacitor 55 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS

100

-

-

... More
Supply and Fixing in repair Running Capacitor 45 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS

50

-

-

... More
Supply and Fixing in repair Running Capacitor 80-100 mfd in Air Conditioner of any make and model complete all as directed. Make : EPCOS / ASIAN / SIEMENS

10

-

-

... More
Supply and Fixing in repair Running capacitor of 6 mfd for fan motor of Air Conditioneer all as directed. Make : EPCOS / ASIAN / SIEMENS

30

-

-

... More
Supply and Fixing in repair Running capacitor of 2.5 mfd for fan motor of Air Conditioneer all as directed. Make : EPCOS / ASIAN / SIEMENS

30

-

-

... More
Supply and Fixing in repair Thermostat Switch with knob suitable for Window Type Air Conditioner of any type and capacity complete all as directed.

25

-

-

... More
Supply and Fixing in repair Plastic Front Grill assembly complete suitable for any make window type 1.5 / 2.0 tone Air Conditioner complete all as directed. Make : LG/Voltas/Carrier/Vediocon

50

-

-

... More
Supply and Fixing in repair Evaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner capacity of 1.5 Ton /2.0 Ton including brazing/welding etc. complete all as directed.

10

-

-

... More
Supply and Fixing in repair Condenser coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split Type Air Conditioner 1.5 ton/2.0 ton including brazing / welding etc. complete all as directed.

20

-

-

... More
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split Type Air Conditioner complete all as directed. Note :- The cost of Material and Labour for charging of gas R-22 is included in this item and nothing shall be paid extra on this account.

80

-

-

... More
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-410 upto the required pressure for 2.00 Ton /1.5 Ton Split Type / Cassate Type Air Conditioner complete all as directed. Note :- The cost of Material and Labour for charging of gas R-410 is included in this item and nothing shall be paid extra on this account.

40

-

-

... More
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-32 upto the required pressure for 1.5 Ton / 2 .00 Ton Window / Split Type Air Conditioner complete all as directed. Make for Ser No 21 to 23. Nafron/Honeywell international/Arkema Group/Mexichem/ Linde plc Note :- The cost of Material and Labour for charging R-32 is included in this item and nothing shall be paid extra on this account.

100

-

-

... More
Supply and Fixing in repair Reverse valve (gun metal) for Window Type / Split Type Air Conditioner of 1.5 Ton / 2.0 Ton including copper pipe and including gas charging as required complete all as directed. Note :- The cost of material and labour for charging gas in Reverse valve is included in this item and nothing shall be paid extra on this account.

20

-

-

... More
Supply and Fixing in repair PCB including Remote Control for remote sensing and operation suitable for Window Type / Split Type Air Conditioner 1.5 Ton / 2.0 Ton complete all as directed. Make :LG / Voltas / Blue Star / Hitachi

30

-

-

... More
Supply and Fixing in repair PCB including remote control for remote sensing and operation suitable for Cassate Type Air Conditioner 2.00 Ton / 4.00 Ton complete all as directed. Make :Voltas / Daikin / Blue Star

2

-

-

... More
Supply and fixing in repair invertor PCB including remote control for remote sensing and operation suitable for window / split type (indoor and outdoor complete)air conditioner1.5/2.0 ton complete all as directed. Make : Daikin/Blue Star/Hitachi/voltas/diakin

10

-

-

... More
Supply and Fixing in repair indoor unit complete suitable for 1.5 Ton Split Type Air conditioner complete all as per manufacturer's instructions complete all as directed. Make :Hitachi(ryoku)/whirlpool/ carrier (Total line)

15

-

-

... More
Supply and Fixing in repair out door unit with compressor complete set suitable for 1.5 Ton split Type Air Conditioner complete all as per manufacturer's instructions and as directed. Make :Hitachi (ryoku)/whirlpool/carrier(total line)

20

-

-

... More
Supply and Fixing in repair indoor unit complete suitable for 2.0 Ton Split Type Air conditioner complete all as per manufacturer's instructions complete all as directed. Make :Hitachi(ryoku)/whirlpool/ carrier (Total line)

7

-

-

... More
Supply and Fixing in repair out door unit with compressor complete set suitable for 2.0 Ton split Type Air Conditioner complete all as per manufacturer's instructions and as directed. Make :Hitachi (ryoku)/whirlpool/carrier(total line)

8

-

-

... More
Supply and Fixing in repair Metal clad Earth plug / socket 32 A 3 Pole, 230V AC complete all as directed. Make : LEGRAND / SCHNIDER / ABB / SIEMENS / HAVELLS

30

-

-

... More
Supply, fixing in repair 3 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete all as directed. Make. Blueline/Microtek/V-Guard

10

-

-

... More
Supply, fixing in repair 4 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete all as directed. Make. Blueline/Microtek/V-Guard

15

-

-

... More
Supply, fixing in repair 5 KVA capacity Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type and designed for input variation between 150V - 250V with output voltage stabilized at 230V with accuracy of (+) or (-) 2.5% complete all as directed. Make. Blueline/Microtek/V-Guard

20

-

-

... More
Taking out unserviceable Blower motor from the indoor unit split Type Air Conditioner of any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed.

10

-

-

... More
M&L for submain wiring with two run of 6 Sqmm, single core, PVC insulated and unsheathed cable conforming to IS 694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metalic PVC grey conduit with all accessories such as Tees, elbows, junction box, reducers etc as required alongwith one run of 6 Sqmm single core PVC insulated and unsheathed cable conforming to IS 694, 1100 volts with copper conductor multi stranded as continous eart wire and connecting to existing main switch board/ distribution board of each building / Qtr as ordered and testing including taking down existing unserviceable submain wiring of any description and size complete all as directed. Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD

180

-

-

... More
M & L for Copper tube, 9 mm / 6 mm dia, superior quality suitable for suction lines of split ACs of any make and capacity drawn trough pipes / fixed to walls / laid on floor or roof complete all as directed. Note : The cost of nut, bolts, screws etc for connecting of copper pipe from indoor to out door unit are included in this item and nothing shall be paid extra on this account.

180

-

-

... More
Supply and Fixing inrepair MCB SP 32 A 'C' curve complete all as directed . Make : LARSEN & TUBRO/ SIEMENS/LEGRAND/SCHNEIDER/HAVELLS INDIA LTD/C & S ELECTRIC LIMITED (C & S)/ABB

30

-

-

... More
Supply and Fixing in replacement old unservicable chassis unit made out of MS sheet suitable for 1.5 Ton Window Type Air Conditinor with remote sensing system complete , duly spray painted with two coats of synthietic enamel paint colour (shade of colour as approved by Engineer-in- Charge) , including heavy duty copper tubing and copper fins evaporator coil, condenser coil ,copper wounded fan motor and suitable front grill etc. complete all as directed.

5

-

-

... More
Supply & fix in repair Sheet metal enclosure having provision for a two pin and earth plug and socket complete with one single pole MCB up to 32 Amps, 240 volt capacity and tested on completion complete all as directed. Note: MCB and Two pin earth plug and socket will be measured and paid separately under appropriate item of BOQ. Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDU

50

-

-

... More
Supply and fix in repair TK foam heat insulation tube of size 1/2inch x3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as directed.

150

-

-

... More
Supply and fix in repair TK foam heat insulation tube of size 5/8 inch x3/8 inch (inner dia x thickness) for AC piping hot and cold duly covered with EBP heavy duty high bond insulation tape heat resistant type complete all as directed.

150

-

-

... More
Supply and fix in repair swing motor for indoor split AC/window AC of any make and capacity complete all as directed.

20

-

-

... More
Supply and fix in repair blower for indoor split AC of any make and any capacity complete all as directed.

15

-

-

... More
Supply and fix in repair indoor Split AC flexible drain pipe made of PVC of length not less than 5 meter and dia not less than 15mm complete all as directed.

30

-

-

... More
Supply and fix in repair AC stand for outdoor unit including with nuts,bolts,rubber pads etc complete for mounting outdoor unit of split AC of any make and any capacity complete all as directed.

60

-

-

... More
M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dian no metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing including taking down existing one complete all as directed. (Note : 2 runs of 4 sqmm cable, 1 run of 2.5 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run). Make : Polycab/Havells/HPL/Finolex/Anchor

250

-

-

... More
Supply and fix in repair dust proof/water proof protection cover of polyster material for indoor and outdoor unit complete all as directed.

50

-

-

... More
Dismantling of existing unservicebale voltage stablizer for repairs with replacement of relays electronic voltage sensor circut and meter, micro switch, indication light RC filters and other connected items for making functional and rewinding of unserviceable transformer with super enameled copper wire of appropriate size, varnishing assembling and testing completeof capacity 2 KVA to 5 KVA upto satisfactory function of any capacity all as directed by Engr- in-Charge.

50

-

-

... More
M&L for replacement of overload protection relay for window AC, water cooler and refrigaretor of make and model as per existing.

50

-

-

... More
S & F in replacement of capillary tubing of any size not less than 0.5 mtr for AC/Water cooler/refrigerator.

35

-

-

... More
S & F in replacement 3 pin plug top of capacity 15 Amp.

30

-

-

... More
Material and Labour for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and charging R-134 gas upto the required pressure complete all as approved and directed.

60

-

-

... More
Taking out the unserviceable compressor (Sealed unit) from water cooler 40 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 444, AE 4440 YGS including suitable relay, over load and starting/running capacitor, flushing out the old bunt condensite from the gas system by vacuumisation, cleaning the system by CTC solution, pressure testing of the system, gas charging with R-134 gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.

15

-

-

... More
Taking out the unserviceable compressor (Sealed unit) from water cooler 60/120 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG model KCE 443, AKR 4460 including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a gas upto the desired pressure, testing & commissioning the water cooler complete all as directed.

10

-

-

... More
Taking out the unserviceable compressor (Sealed unit) from water cooler 150 liters capacity of any make and type and repalacement of new compressor obtained from the factory out let make Copeland/Tecumseh/Whirlpool/LG, model ACJ 513, AW 1000, including suitable relay, over load and starting/running capacitor flushing out the old burnt condensafe from the gas system by vacuumisation, cleaning the system by CTC solution , pressure testing of the system, gas charging with R-134a/22 gas upto the desired pressure, testing & commissioning the water cooler complete all as directed. Make for Ser No 55 to 57 : LG/GMCC/Daikin/Blue Star/ Voltas.

5

-

-

... More
S&F in repair blower fan motor 1/10 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.

15

-

-

... More
S&F in repair blower fan motor 1/35 HP suitable for water cooler, single phase 230 Volts including mounting ring/washer complete all as directed.

15

-

-

... More
S&F in repair Fan blade plastic suitable for 1/35 HP motor complete all as directed.

15

-

-

... More
S&F in repair Fan blade plastic suitable for 1/10 HP motor complete all as directed.

10

-

-

... More
S&F in repair stainless steel taps push button type, 15mm dia for water cooler of any capacity suitable for Usha/Blue Star water coolers complete all as directed.

50

-

-

... More
S&F in repair Relay & overload set suitable for water cooler complete all as directed. Make : Annapurna/Reneutral/Denfoss

20

-

-

... More
S&F in repair Running capacitor of 15 mfd complete all as directed.

20

-

-

... More
S&F in repair Running capacitor of 40/60 mfd complete all as directed.

15

-

-

... More
Material and labour for cutting the base of water cooler of any capacity and fabrication of new base made from MS sheet 16 SWG and angle iron as per original size and shape including painting the coolers with two coats of synthetic enamelled paint of selected shade and colour over a coat of red oxide primer complete all as directed. Note:- The quoted rate shall deem to be included for thimbles, nuts, bolts, washers or any other hardware needed to fix the item and shall be provided by the contractor when and whenever required.

2

-

-

... More
S&F in repair Thermostate valve complete all as directed.

20

-

-

... More
Material and labour for taking out the inner water tank of water cooler of any size and brazing/welding including applying compounds as required to stop leakage from the water tank, replacement of glass wool/toffed sheet, chicken wire mesh of appropiate thicness and spacing and stoppage of leakage in tubing (if any) around the tank and refixing as per oringinal pattern complete all as directed.

2

-

-

... More
S&F in repair copper condesor for 40/80 ltr capacity water cooler complete all as directed.

11

-

-

... More
S&F in repair copper condesor for 60/120 ltr capacity water cooler complete all as directed.

10

-

-

... More
S&F in repair drain hose pipe not less than 1.5 metre length and as per existing dia (30mm/40mm) with clamping arrangment complete all as directed.

30

-

-

... More
S&F in repair Water Cooler Stainless Steel body unit with Condenser Coil, Copper Wound Fan Motor and tank including heavy duty copper tubing, stainless steel taps push button type 15 mm dia of 40/80 ltr capacity complete all as directed.

9

-

-

... More
S&F in repair Water Cooler Stainless Steel body unit with Condenser Coil, Copper Wound Fan Motor and tank including heavy duty copper tubing, stainless steel taps push button type 15 mm dia of 60/120 ltr capacity complete all as directed. Mek for ser No 73 & 74. Voltas/Blue Star/Usha

5

-

-

... More
Note:- The contractor shall deposited the old material retrived from item no 01 to 74 to AGE E/M Refg store yard by his own arrangements without any financial benefits and shall maintain the record for the same as specified by Engr-In-Charge and GE.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.