If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696470_1Tender No
CE BTZ/FDK/TOKEN-26 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)
1
425773
-
... More
Lump sum price worked out by the tenderer for ROAD, PATH, CULVERT AND HARD STANDING WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)
1
23031482
-
... More
Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)
1
2765297
-
... More
Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)
1
108209
-
... More
Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)
1
2088610
-
... More
Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)
1
259933
-
... More
Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)
1
3810074
-
... More
Lump sum price worked out by the tenderer for HOT WATER SUPPLY, SUMMER APPLIANCES AND AIR CONDITIONING WORKS as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately)
1
820316
-
... More
Lump sum price worked out by the tenderer for SITE CLEARANCE, EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately)
1
6288293
-
... More
Lump sum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately)
1
5068692
-
... More
Schedule 'A' Part-XIII(ARBORICULTURE)
-
-
-
... More
Supply and stacking of good earth at site brought from outside MD land including royalty and carriage for all leads and lifts all as specified and directed by Engineer-in-Charge. Note :- For the purpose of payment the stack measurement shall be reduced by 20% for voids complete all as specified and directed
105
-
-
... More
Supply and stacking of well decomposed Cow dung/ meegni manure including royalty, loading, unloading, transportation and stacking etc. at site. Note:- For the purpose of payment the stack measurement shall be reduced by 10% for voids.( 338 Cum for Lawns and 49 Cum for trees and shrubs)
200
-
-
... More
Supply only liquid form chlorophyriphos 20 % EC conforming to IS: 8944 complete all as specified and directed.
25
-
-
... More
Supply and stacking of Regent/ DCM agronil to improve the soil quality complete all as specified and directed.
550
-
-
... More
Supply and stacking of gypsum 50 kg bag complete all as specified and directed.
100
-
-
... More
LAWN: Excavation to a depth of 0.30 m removing all foreign bodies over 50 mm dia, filling in the same with the excavated earth (after removal of rubbish) mixed with manure in the ratio of 3:1 by volume (3 part of stacked volume of earth after reduction by 20% and 1 part of stacked volume of manure after reduction by 10%), as indicated on grading plans. All finished areas shall slope to drain. Where no grades are shown, the areas shall have a smooth a continual grade between existing or fixed controls (such as walsk, curbs catch basins, elevations at steps or buildings) and levels shown on plans, roll scarify, rake and level as necessary to obtain true, even grassing surfaces. All finished grades shall meet approval of the GE before grassing is done. Dribbling of doob grass according to site at a spacing of 5 cm apart grassing with specified grass including watering and maintenance of lawn till the grass forms properly. The grass shall be free of weeds and fit for moving including mandatory maintenance of lawn for 6(Six) months complete all as specified and directed by Engineer-in-Charge. Note: - (i) Cost of dhub/doob grass is included in unit rate of this item. However, manure etc. as required shall be measured & paid for separately. (ii) Manure & pesticide required for maintenance of plants during maintenance period shall be arranged by the contractor at his own cost and rates of the same shall be deemed to be included in the quoted rates.
2200
-
-
... More
PITS FOR TREES :Preparation of pit for trees by excavating in ordinary soft/ loose soil of size 60 cm X 60 cm X 60 cm deep, getting out, returning , filling in the same with the excavated earth (after removal of rubbish) mixed with manure in the ratio of 2:1 by volume (2 part of stacked volume of earth after reduction by 20% and 1 part of stacked volume of manure after reduction by 10%) flooding with water, dressing and removing surplus soil to a distance not exceeding 50 m including spreading & levelling complete all as specified and directed. Note- (i) Cost of manure, Pesticide or extra good earth if needed to be paid for separately.
530
-
-
... More
Supplying & Planting of "Neem" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
50
-
-
... More
Supplying & Planting of "Drum Stick" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
50
-
-
... More
Supplying & Planting of "Mango" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
50
-
-
... More
Supplying & Planting of "Lemon" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Sheesham" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Amla" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Guava" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Pomegranate" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified.
30
-
-
... More
Supplying & Planting of "Bel" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
25
-
-
... More
Supplying & Planting of "Keenu" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
40
-
-
... More
Supplying & Planting of "Dek" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed.
30
-
-
... More
Supplying & Planting of "Gulmohar" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Jamun" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Amaltas" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
Supplying & Planting of "Pipal" trees as approved by GE of 2 to 3 feet height in 10" to 12" poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
30
-
-
... More
PITS FOR SHRUBS : Preparation of pit for shrubs by excavating in ordinary soft/ loose soil of size 30 cm X 30 cm X 45 cm deep, getting out, returning , filling in the same with the excavated earth (after removal of rubbish) mixed with manure in the ratio of 3:1 by volume (3 part of stacked volume of earth after reduction by 20% and 1 part of stacked volume of manure after reduction by 10%) flooding with water, dressing and removing surplus soil to a distance not exceeding 50 m including spreading & levelling complete all as specified and directed Note- (i) Cost of manure, Pesticide or extra good earth if needed to be paid for separately.
300
-
-
... More
Supplying & Planting of "Ashoka Regional" shrubs as approved by GE of 1 to 1.50 feet height in poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
15
-
-
... More
Supplying & Planting of "Bougen Villa" shrubs as approved by GE of 1 to 1.50 feet height in poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
120
-
-
... More
Supplying & Planting of "Benjamin" shrubs as approved by GE of 1 to 1.50 feet height in poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed.
30
-
-
... More
Supplying & Planting of "More Pankh" shrubs as approved by GE of 1 to 1.50 feet height in poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
25
-
-
... More
Supplying & Planting of "Hedge" shrubs as approved by GE of 1 to 1.50 feet height in poly bag in pits (Holes) as prepared here-in -before and complete maintenance of trees during currency of contract including mortality replacement with same height of plant complete all as specified and directed
105
-
-
... More
TREE GUARDS :Supplying & fixing of tree guards 60 CM in plan and 1.5 meters high from ground level made of 30 mm X 30 mm X 3 mm angel iron frame and 30 mm X 3 mm flat iron welded wire mesh of size 32 mm X 32 mm X 3 mm and vertical angle with shoe shall be embedded in the round firmly tree guard as shown in drawing (Drawing No : CWE/SGNR/SD/158/15 Sheet-1/1 revised dated 13 Sep 2019) with number plate and writing name of tree complete all as specified and directed Note: Tree guard shall be painted two coat of synthetic enamel paint over of red oxide primer complete in all respect.
140
-
-
... More
Complete maintenance of 500 trees and 280 shrubs by weeding, watering, saucer making once in every monthly for plants insect pest management (as and when required) pruning dried branches once in a week, depositing the materials at place as directed by Engineer-in-Charge, planting new plants in place of dead plants of same species and height tuning without any extra cost to the department and enrichment with manure @ 0.003 cum per pit as directed. Note : Manure & pesticide required for maintenance of plants under this item shall be arranged by the contractor at his own cost and rates of the same shall be deemed to be included in the quoted rates.
12
-
-
... More
Schedule 'A' Part-XIV(EOT CRANE)
-
-
-
... More
Design, supply, installation, testing & commissioning of double girder type, electric operated 2 Nos of cranes situated on two separate cross travel girders having working capacity of 2 Tons and 5 Tons, cross span of 11 meters, 7 meters lift, designing for the parameters as specified and complete with all accessories as specified and as directed. Note: (a) The crane shall be designed taking the combination of all parameters of both cranes. (b) Two separate cross travel and one long travel mechanism shall be considered.
1
-
-
... More
Design, supply, installation, testing & commissioning of double girder type, electric operated 2 Nos of cranes situated on two separate cross travel girders having working capacity of 2 Tons and 5 Tons, cross span of 18 meters, 7 meters lift, designing for the parameters as specified and complete with all accessories as specified and as directed. Note: (a) The crane shall be designed taking the combination of all parameters of both cranes. (b) Two separate cross travel and one long travel mechanism shall be considered.
1
-
-
... More
Schedule 'A' Part-XV(MISCELLANEOUS PARTS)
-
-
-
... More
S & F factory made precast cover slab made of steel fibre reinforced concrete (SFRC), medium duty, 100 kN breaking load in any shape and size (square/ rectangular/circular), 75 mm thickness, minimum M30 grade of concrete, conforming to IS 12592: 2002 complete all as specified and as directed.
600
-
-
... More
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
90
-
-
... More
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
110
-
-
... More
Dismantling of rolling shutter complete all as specified and as directed.
22.08
-
-
... More
Taking down stop cock, bib tap, stop valve etc. complete all as specified and as directed.
12
-
-
... More
M & L for forming 12 mm thick expansion joints in 75 mm thick slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified and as directed.
87.53
-
-
... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
10
-
-
... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
31
-
-
... More
S & F hot pressed moulded SMC (sheet moulding compound) junction box of inside dimension 250 mm X 200 mm X 100 mm including 2 Nos aluminium stud terminal of suitable size and 1 No MCB SP 6 amp and fixed on pole with clamps, bolts and nuts complete all as specified and as directed.
60
-
-
... More
S & F LED street light fitting of 45 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and as directed. (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range: 140 to 270 volts © Temp operating range: Minus 10°C to Plus 45°C (d) Power factor: Minimum 0.95 (e) THD: Max10%. (f) IP rating: Minimum IP66. (g) IK rating: Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz. open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT: 5000 K. (m) CRI: More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time: 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
60
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 600 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 600 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 400 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 250 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 200 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCCB rated current (In): 100 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (d) MCCB rated current (In): 20 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (e) MCCB rated current (In): 16 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (f) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: - 7 Nos (g) Spare compartments for 100 Amps, 4 pole MCCB – 1 No and 32 Amps, 4 Pole MCCB – 1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-400 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
1
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 400 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 250 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 160 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 40 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (c) MCCB rated current (In): 16 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -4 Nos (d) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: - 10 Nos (e) Spare compartments for 63 Amps, 4 pole MCCB – 1 No (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-400 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
1
-
-
... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 300 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 300 Amps rated aluminium busbar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 100 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCCB rated current (In): 40 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (c) MCCB rated current (In): 32 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (d) MCCB rated current (In): 16 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (e) MCB, SPN, 10 kA, C-type, rated current 6 to 32 A: - 4 Nos (f) Spare compartments for 40 Amps, 4 pole MCCB – 2 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-100 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Danger Notice Plate for LT (F) 3 Phase, 5 kW automatic street light control switch using infrared sensor based twilight/ nature switch for automatic switching of streetlights, consisting of weatherproof powder coated metal box of suitable size, 1 No of twilight/ nature switch dusk to dawn, 25 Amps 3 pole contactor- 1 No, 20 Amps MCB- 6 Nos (3 Nos input and 3 Nos output) including wiring with 10 sqmm copper wiring, IP54 protection grade- 1 No (G) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)
1
-
-
... More
S & F two core flat, FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.
600
-
-
... More
M & L for auguring under road, pavement, hard standing, railway lines by trenchless technology using latest boring technique and necessary machine for insertion of GI/CI/PP-R/PVC pipe of any dia/ bore/size complete all as specified and as directed.
20
-
-
... More
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
1
-
-
... More
M & L for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.0) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.
1
-
-
... More
Supplying, laying, connecting, jointing and testing in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.
200
-
-
... More
Supplying, laying, connecting, jointing and testing in trenches 80 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.
300
-
-
... More
M & L for construction of new valve pit/chamber of size 1050 mm (Length) X 1050 mm (Breadth) X 1050 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.
2
-
-
... More
M & L for construction of new valve pit/chamber of size 450 mm (Length) X 450 mm (Breadth) X 450 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.
3
-
-
... More
Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 250 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed.
150
-
-
... More
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
891
-
-
... More
M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
170
-
-
... More
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
34
-
-
... More
M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
4
-
-
... More
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
83
-
-
... More
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
4
-
-
... More
S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately.
6
-
-
... More
S & F modular blanking plate 1 module complete all as specified and as directed.
30
-
-
... More
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
300
-
-
... More
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
600
-
-
... More
Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
150
-
-
... More
Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
100
-
-
... More
S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.
98
-
-
... More
S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.
4
-
-
... More
S & F including testing LED high bay 50 watt luminaire with aluminium die cast housing with mechanical mechanism for mounting, with driver complete suitable for fixation on wall/roof/railings with robust body, corrosion resistant, superior finish. The system wattage of fitting should not be more than 50 watt ± 10%, having surge protection of minimum 4kV internal, power factor more than 0.95, corelated colour temperature should 5700⁰-6500⁰ Kelvin, total hormonic distortion (THD) should not be more than 10%, lumen efficacy should not be less than 130 lumens per watt, total input voltage range 140-270V AC, colour rendering Index should not be less than 70, IP65 protection level complete all as specified and directed. Note: - (i) Cost of mechanical mountings and holders for lights, nut & bolts are inclusive in this item.
1
-
-
... More
S & F including testing LED high bay 150 watt luminaire with aluminium die cast housing with mechanical mechanism for mounting, with driver complete suitable for fixation on wall/roof/railings with robust body, corrosion resistant, superior finish. The system wattage of fitting should not be more than 150 watt ± 10%, having surge protection of minimum 4kV internal, power factor more than 0.95, corelated colour temperature should 5700⁰-6500⁰ Kelvin, total hormonic distortion (THD) should not be more than 10%, lumen efficacy should not be less than 130 lumens per watt, total input voltage range 140-270V AC, colour rendering Index should not be less than 70, IP65 protection level complete all as specified and directed. Note: - (i) Cost of mechanical mountings and holders for lights, nut & bolts are inclusive in this item.
59
-
-
... More
S & F telephone socket outlet complete all as specified and as directed.
20
-
-
... More
S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.
80
-
-
... More
S & F television antenna socket outlet complete all as specified and as directed.
4
-
-
... More
S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.
40
-
-
... More
S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
34
-
-
... More
S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed.
27
-
-
... More
S & F central hole basin mixer with regular spout with popup waste system with braided boses as per catalogue No. SKU: QQT-CHR-7169B of Jaquar or equivalent of Make as mentioned under Appendix “B” of Particular Specifications complete all as specified and as directed.
8
-
-
... More
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed.
40
-
-
... More
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 1 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.
5
-
-
... More
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.
7
-
-
... More
S & F evaporative air coolers (desert coolers) as per IS 3315: 2019, minimum air capacities 6000 cum per hour, sump tank capacity 120 litres, cooling efficiency not less than 65%, maximum power consumption 400 watts, plastic body, noise level not more than 65 dBA at 1 m distance complete all as specified and as directed.
40
-
-
... More
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 2.0 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.
7
-
-
... More
Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 360 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.
1
-
-
... More
Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.
1
-
-
... More
Supply, installation, testing & commissioning of double cylinder air compressor capacity 3 HP, 3 Phase, air displacement 250 LPM, compressor speed 925 rmp complete all as specified and as directed.
2
-
-
... More
Supply, installation, testing & commissioning of 5 HP, 3 Phase, vehicle washing motor, compressor with all accessories complete all as specified and as directed.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%