Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_669975_1Bid Award Id
ViewTender No
CWE(BHI)/HAL-34/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fixing in replacement of IDMTL Relay CGI14N of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of Aegis Relay Low setting & High set of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of Jaw Contacts of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of Male fixed contact of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of VCB Bottles of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of VCB mechanism complete with motor of make & specifications as existing at site/ latest available and capatible after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of Epoxy Spout Bushings of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
1
-
-
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 3 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 3 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices.to make it functional including tesing on existing load complete all as specified and as directed.
8
-
-
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 4 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 4 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices to make it functional including tesing on existing load complete all as specified and as directed.
8
-
-
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 5 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 5 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices to make it functional including tesing on existing load complete all as specified and as directed.
2
-
-
Disconnecting of HT and DC connections from existing bus bar and disconneting trolly including servicing of complete parts of RMU 6 way, cleaning with carbon tetra chloride, lubrication of mechanical parts, adjustment and calibration of complete relays etc including checking parts, repairs to control wiring with single core copper conductor of existing size as required at site for RMU 6 way, of any type, any make for satisfactory running including replacement of defective spare parts/items and applying one coat of 11 KV insulation paint on bus bar, spouts and other connected parts/items, re-assembling the same, re-connecting all HT & AC/ DC connections reconnecting/replacing all the ABB boot from the cable & reconnecting with the terminal after installing new boot on the cable terminal. Cost of boots deemed to be included in the quoted prices to make it functional including tesing on existing load complete all as specified and as directed. Notes for BOQ item No. 11.00 to 14.00 : (i) Taking down of old defective spare parts is deemed to be included in quoted rates and Supply and fixing of new spare parts shall be measured and paid separately.
(ii) Parts replaced shall be identical to those specified by original manufacturer as existing at site.
(iii) Parts of minor nature such as nuts, bolts, screws & washers required at site are deemed to be included in quoted rates.
(iv) Servicing of complete parts shall be carried out through OEM/authorized rep of OEM.
(v) A Board of Officers shall be appointed by the Accepting Officer for ascertaining the repair work required in E&M installations and all inventory shall be prepared in presence of Engineer-in-charge & Contractor.
2
-
-
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out complete all as specified and directed.
56.7
-
-
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
39.46
-
-
Removing surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
12.85
-
-
Material and labour for sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specified and directed.
Note : Punned thickness shall be considered for payment.
11.34
-
-
Material and labour for precast concrete cable cover class HV type 1 flat size 300mmx 180mm and thickness 40mm ISI marked laid flat, dry and adjacent to each other, perpendicular to the central axis of the cable in trenches, complete all as specified and directed.
700
-
-
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary T&P for passing of LT/HT cables complete all as specified and as directed.
20
-
-
Supply and fixing of Control Wiring with 1.5 sqmm FRLS copper conductor for control circuits and 2.5 sqmm FRLS copper conductor for CT circuits as per existing diagram including provided cable ties, beading etc of VCB or RMU complete all as specified and directed.
2
-
-
Material and labour for feeder pillars box out door type made out of MS sheet (CRCA) of thickness not less than 3.15 mm, of size 150 x 65 x 90 cm with copper bus bar strip 3 Nos of size 100 cm in length, 4 cm in width and 6 mm in thickness suitable for 11000 volt grade mounted on HT porcelain insulator, front opening door having two leaf braced with hinged, mounted on 4 Nos angle iron 100 x 100 mm x 8 mm, 90 cm long duly welded with box and grouted in PCC 1:3:6 type C-1 using 20 mm graded mechnically crushed stone aggregates block of size 30 cm x 30 cm x 15 cm, top of box shall be of MS sheet duly bent in slope, tapper with projection of 20 mm on all side, weather / vermin proof with high quality of rubber beeding on panel door, cable entry arrangements at bottom includes earthing terminals 2 Nos at both side duly painted with red stove enamelled paint 2 coat over a primer coat after taking down/out feeder box as existing at site complete all as specified and as directed.
2
-
-
Material and labour for GI pipe 80 mm bore, light grade as in trenches, under road, floor, fixed to wall with fixing arrangement with suitable size of MS clamps made from 40x3 mm size flat iron including nuts,bolts & washers or along the pole with fixing arrangement etc for cable protection complete all as specified and as directed .
20
-
-
Material and labour for heat shrinkable straight through cable joint suitable for 11000 volts XLPE cable aluminium conductor of size 3 core 240 sqmm complete all as specified and as directed.
2
-
-
Material and labour for heat shrinkable straight through cable joint suitable for 11000 volts XLPE cable aluminium conductor of size 3 core 120 sqmm complete all as specified and as directed.
2
-
-
Material and labour for jointing and testing HT indoor type (heat shrinkable) cable end joint suitable for HT cable 11000 volts grade 240 Sqmm 3 core complete all as specified and as directed.
3
-
-
Material and labour for jointing and testing HT indoor type (heat shrinkable) cable end joint suitable for HT cable 11000 volts grade 120 Sqmm 3 core complete all as specified and as directed.
2
-
-
Material and labour for jointing and testing HT indoor type (heat shrinkable) cable end joint suitable for HT cable 11000 volts grade 95 Sqmm 3 core complete all as specified and as directed.
2
-
-
Supply and fixing of Spring charging motor AC / DC of VCB trolley as per existing sample complete all as specified and directed.
2
-
-
Supply and fixing in replacement of spring charging gear assembly for VCB trolly of make & specifications as exist at site complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of motor cut off for spring charging motor of VCB trolly of make & specifications as exist at site complete all as specified and as directed.
3
-
-
Supply and fixing of power pack with input 220-110V, AC and output 24V, DC for VCB trolly of make & specifications as existing at site after taking down power pack as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of closing coil 24 V, DC for VCB trolly of make & specifications as existing at site after taking down coil as exists at sitecomplete all as specified and as directed.
3
-
-
Supply and fixing of shunt tripping coil 24 V, DC for VCB trolly of make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
3
-
-
Supply and fixing of plug & socket assembly for VCB trolly of make & specifications as existing at site after taking down plug as exists at site complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of CT mounted in epoxy compound with dual ratio 100/50/5 Amps or 200/100/5 Amps with & including making connections with copper wire 2.5 Sqmm and beading, of make & specifications as exist at site for VCB complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of electronic hooter of VCB complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of HRC fuse base with HRC fuse 20A,415V,80 kA complete all as specified and as directed.
2
-
-
Supply and fixing of multifunctional meter for 11 KV VCB of make & specifications as existing at site complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of selector switch suitable for amp meter/volt meter for 11 KV VCB/RMU of make & specifications as existing at site complete all as specified and as directed.
4
-
-
Supply and fixing in replacement indicator lamp as per existing colour code for 11 KV VCB/RMU complete all as specified and as directed.
10
-
-
Supply and fixing in replacement of ZZ switch, trip circuit healthy of VCB complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of air breaker contactor relay of VCB complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of common alarm relay voltage range 24-30V, DC of VCB as existing at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of microprocessor numerical relay of VCB as per latest specification available and of authorised OEM as existing at site complete all as specified and as directed by Engr-in-Charge.
2
-
-
Supply and fixing in replacement of resin encapsulated vacuum interrupter bottle for circuit breaker trolly of 11 KV VCB as existing at site complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of self powered protection relay of RMU complete all as specified and directed .
1
-
-
Supply and fixing in replacement of resin cast ring core protection Current Transformer of ratio 14.4/0.075A, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of resin cast ring core metering current transformer of ratio 80/1A, Class 1.0, VA-2.5, 50C/S of RMU complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of digital multifunction meter for 11 KV RMU complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of shunt tripping coil as existing of RMU complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of live cable LED indicators thru capacitor volage dividers mounted on the bushings assembly complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of load break switch mechanism assembly (2PA Mechanisum w/o hex rod) having two position spring assisted, Inegrated line earthing switch making capacity complete all as specified and as directed. Make : ABB Cat Part No. NHP101985R002 or equivalent as approved by GE.
2
-
-
Supply and fixing in replacement of isolator switch mechanism assembly having two position spring assisted, Integrated line earthing switch making capacity complete as per existing sample all as specified and as directed.
Make : ABB Cat Part No. NHP101935R2 or equivalent as approved by GE.
2
-
-
Supply and fixing in replacement of master trip relay as existing complete all as specified and as directed.
2
-
-
Supply and filling of SF6 Gas of VCB cylinder (9 KG/Cyl) complete all as specified and as directed. Make : ABB Cat Part No. S194-5600-103-17 or equivalent as approved by GE.
1
-
-
Suppy and fixing in replacement of Wave washers M12 complete all as specified and as directed.
Make : ABB Cat Part no. NB336174P567 or equivalent as approved by GE.
11
-
-
Suppy and fixing in replacement of Spacer 13*16*20mm complete all as specified and as directed. Make : ABB Cat Part no. NHP403206P1 or equivalent as approved by GE.
15
-
-
Suppy and fixing in replacement of Clamping nut M8 *21 complete all as specified and as directed. Make : ABB Cat Part no. NHP402158P2 or equivalent as approved by GE.
12
-
-
Suppy and fixing in replacement of Cable Bushing Plate complete all as specified and as directed. Make : ABB Cat Part no. 1SNHP304737P1S1 or equivalent as approved by GE.
2
-
-
Suppy and fixing in replacement of Bushing 400 Series bolted type complete all as specified and as directed. Make : ABB Cat Part no. 1NNHP201699R1N1 or equivalent as approved by GE.
2
-
-
Suppy and fixing in replacement of 'O' ring 72*6 Bushing 400 Series bolt complete all as specified and as directed. Make : ABB Cat Part no. NHP402076P15 or equivalent as approved by GE.
6
-
-
Suppy and fixing in replacement of Rishab complete all as specified and as directed. Make : ABB Cat Part no. Master 3430 or equivalent as approved by GE.
1
-
-
Supplying, laying, jointing, testing and commissioning HT XLPE cable, 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 120 Sqmm, 3 core, laid in trenches /pipes /ducts /along poles/ walls/ equipment etc including taking down of old cables complete all as specified and directed. Notes : (i) Payment for excavation & earth work, sand cushioning, protection pipes, end termination cable joints & protection covers shall be made for separately.
150
-
-
Material and labour in replacement for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcol dust and common salt filling in alternate layers and electrode connected by GI strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of GI connected to test termination point protected by 15mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 including exluvation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No 3 of SSR Part - I complete all as specified and directed. Notes : (i) The unit rate shall include for GI water pipe, protection pipe, wire mesh, funnel, excavation, RCC pit cover, PCC, test point, G I wire 4 mm dia from top of earth plate upto 5 mtr ground level.
(ii) PCC pit shall be provided at least 1.5 mtr away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fixing junction, elbows etc. shall deemed to be included in the unit rate. (iii) RCC pit cover shall be percast of RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4kg/Sqm in lieu of cast iron cover.
3
-
-
Material and labour in replacement for earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcol dust and common salt filling in alternate layers and electrode connected by galvanised iron strip 32 mm x 6 mm by means of bolts, nuts, check nuts and washers connected to test termination point protected by 40mm bore GI pipe light grade and GI pipe light grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 type B1 including exluvation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in electrical plate No 3 of SSR Part - I complete all as specified and directed. Notes : (i) The unit rate shall include for GI water pipe, protection pipe wire mesh, funnel, excavation, RCC pit cover, PCC, test point, GI strip 32 X 6 mm from top of earth plate upto 5 mtr.
(ii) PCC pit shall be provided at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction, elbows etc. shall deemed to be included in the unit rate. (iii) RCC pit cover shall be percast of RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4kg/Sqm in lieu of cast iron cover.
3
-
-
Taking out of burnt HT/LT primary/secondary winding from the unserviceable transformer of any capacity, cleaning all the limbs, rewinding with supper enamelled wire of same weight, gauge etc of HT/LT winding with suitable gauge by calculating number of turns as per voltage of transformer or voltage stablizer varnishing and drying by vaccum impregnating, replacing insulating material, nuts, bolt etc including testing as per latest IS/BS specification to make it functional compete all as specified and as directed.
400
-
-
Dehydration and filteration of transformer oil by using dehyderation and filteration plant, heating and filteration of oil to be carried out till the di-electric strength reaches not less than 45 KV withstand for one minute is achieved, for any capacity of transformer including testing of strength including draining out of oil and refilling of oil in the transformer complete all as specified and as directed.
Notes :- The contractor is required to submit the di-electric report after dehydration and filtration of each transformer before claiming payment.
7500
-
-
Opening of all electrical connections HT/LT from the bushings/terminal box of the unserviceable distribution transformer, indoor/outdoor type from existing position/location, of any make & specifications, of capacity upto 315 KVA & transporting the transformer to authorised dealer workshop for repairs with opening of top cover including conservator, dehyderating breather and allied items, inspecting the same to assess the repairs required, making the joint inventories of unserviceable items/parts to carryout the repair works, cleaning, greasing and overhauling complete including taking out & replacement of unserviceable /worm out parts with new parts, fixing parts by draining out of transformer oil to make the transformer serviceable, refilling the transformer oil after repairing/dehyderation of oil to get the di-electric strength of oil upto 45 KV(rms), re-assembling after repairing and transporting the repaired transformer back to the work site, connecting all eletrical/ mechanical connections, commissioning of transformer on load after testing complete all as specified and as directed.
3
-
-
Opening of all electrical connections HT/LT from the bushings/terminal box of the unserviceable distribution transformer, indoor/outdoor type from existing position/location, of any make & specifications, of capacity from 400 KVA to 630 KVA & transporting the transformer to authorised dealer workshop for repairs with opening of top cover including conservator, dehyderating breather and allied items, inspecting the same to assess the repairs required, making the joint inventories of unserviceable items/parts to carryout the repair works, cleaning, greasing and overhauling complete including taking out & replacement of unserviceable /worm out parts with new parts, fixing parts by draining out of transformer oil to make the transformer serviceable, refilling the transformer oil after repairing/dehyderation of oil to get the di-electric strength of oil upto 45 KV(rms), re-assembling after repairing and transporting the repaired transformer back to the work site, connecting all eletrical/ mechanical connections, commissioning of transformer on load after testing complete all as specified and as directed.
Notes for Ser No 69 & 70:- (i) Spare parts shall be measured and paid for separately under respective items as supply only in replacement. (ii) All parts/components replaced shall be identical to those specified by original manufacturer (iii) A Board of Officers shall be appointed by the Accepting Officer for the transformers required repair works and all inventory shall be prepared in presence of contractor/accrediated reps. (iv) Transformer oil required for certifiying/de-hydration shall be measured and paid seperately.
(v) Additional Transformer oil required for topping up shall be measured and paid seperately.
2
-
-
Material and labour for PCC 1:3:6 type C-2 (using with 40 mm graded stone aggregate) for foundation and mass filling complete all as specified and as directed.
2
-
-
Material and labour for PCC 1:2:4 type B-1 (using 20 mm graded machanically crushed stone aggregate) for foundation and copping of poles including necessary form work complete all as specified and as directed.
1.5
-
-
Supply and fixing in replacement of HT 11 KV outdoor type, triple pole, gang operated air break switch suitable for vertical mounting fixed type complete mounted on insulators and steel frame, with operating mechanism worked from ground level for current rating upto 400 Amps complete all as specified and directed.
2
-
-
Material and labour in replacement for cross arm bracing, support, clamps and back plates fabricated from structural steel sections including nut bolts washers welding, bending cold or hot, drilled holes for bolts in any shape or size as indicated or directed and inclusive of one coat of primer, one undercoat and one finishing coat of paint complete all as specified and directed.
1
-
-
Supplying, filling and pouring transformer oil, ISI marked, in sealed containers for Voltage stablizers and transformer, conforming to IS-335 with di-electric strength not less than 50 KV and testing for strength including recording results complete all as specified and as directed. Notes:- (i) Empty sealed container shall become Govt property & shall be taken on charge through RV. (ii) Transformer oil shall be as per IS.
(iii) Purchase vouchers alongwith manufacturer's test certificate shall be produced at the time of payment.
1000
-
-
Cleaning and preparation surfaces of existing feeder pillar box and applying two coats of synthetic enamel paint over a coat of red oxide primer including removal of old paint by scratching complete all as specified and as directed.
7
-
-
Disconnecting the electrical connections, cleaning and preparation the surfaces after removing of old paint by scratching from existing transformer of capacity 60 to 100 KVA and applying two coats of synthetic enamel paint over one coat of red oxide primer to entire exposed surfaces complete all as specified and as directed.
5
-
-
Disconnecting the electrical connections, cleaning and preparation the surfaces after removing of old paint by scratching from existing transformer of capacity 160 to 250 KVA and applying two coats of synthetic enamel paint over one coat of red oxide primer to entire exposed surfaces complete all as specified and as directed.
3
-
-
Disconnecting the electrical connections, cleaning and preparation the surfaces after removing of old paint by scratching from existing transformer of capacity 315 to 400 KVA and applying two coats of synthetic enamel paint over one coat of red oxide primer to entire exposed surfaces complete all as specified and as directed.
3
-
-
Disconnecting the electrical connections, cleaning and preparation the surfaces after removing of old paint by scratching from existing transformer of capacity 500 to 630 KVA and applying two coats of synthetic enamel paint over one coat of red oxide primer to entire exposed surfaces complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of 1100 volts, porcelain vitreous brown body bushing, LT, 415 volts grade as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of 1100 volts, porcelain viterous brown body bushing, LT, 415 volts grade as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of 1100 volts, threaded brass bushing rod with nuts, check nuts & washers, LT, 415 volts grade as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and as directed.
4
-
-
Supply and fixing in replacement of 1100 volts, threaded brass bushing rod with nuts, check nuts & washers, LT, 415 volts grade as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of 11 KV porcelain vitreous brown body bushing insulators for HT side, as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of 11 KV porcelain vitreous brown body bushing insulators for HT side, as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of 11000 volts, threaded brass bushing rod with nuts, check nuts & washers as per IS 3347 for transformer of capacity upto 315 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of 11000 volts, threaded brass bushing rod with nuts, check nuts & washers as per IS 3347 for transformer of capacity from 400 KVA to 630 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of cork sheet for top cover suitable for 50 to 315 KVA capacity transformers complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of cork sheet for top cover suitable for 400 to 630 KVA capacity transformers complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of breather asembly ISI marked in sealed container suitable upto 315 KVA capacity transformers complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of breather asembly ISI marked in sealed container suitable for 400 to 630 KVA capacity transformers complete all as specified and as directed.
2
-
-
Supply and fixing of Ampere meter digital type, 96 x 96 mm, 0 - 200 Amps with built in selector switch complete for VCB 11 KV complete all as specified and directed.
2
-
-
Supply and fixing of volt meter 96 x 96 mm, digital type, 0- 12KV with built in selector switch complete for VCB 11 KV & RMU's complete all as specified and directed.
2
-
-
Supply and fixing on wall First Aid Kit box of size 360 mm x 150 mm x 80 mm containing of following items complete all as specified and as directed.
(a) Dettol bottle100 ml Each- 02 Nos
(b) Antiseptic Ointment 15 gm-01 No
(c) Crocin tablets strip containing 10 Tablets -01 strip
(d) Hydrogen peroxide 50 ml -01 bottle (e) Cotten small rolls- 2 Nos
(f) Cotten strip small roll -04 Nos
(g) Moove tube- 01 No
(h) Betadine Tube 15 gm -01 no
3
-
-
Supplying and fixing of shock treatment chart of flex printing for ready reference as a precaution to be used at the time of electric shock for the person working in the sub station for their safety as a first aid including with clear glass cover & wooden frame and fixing on wall complete all as specified and as directed.
3
-
-
Supply and fixing in replacement of Battery 12 volt 150 Ah maintenance free type with two year warranty for battery bank complete all as specified.
6
-
-
Material and labour for inspecting and servicing of SMPS (15 KVA) along with battery bank, three phase installed at various locations within Air Force Station Halwara by cleaning the complete unit with suitable cleaning agent and checking the serviceability state of all the Main card/mechanisms/all components/fans/control PCB etc complete and replacing the defective spare parts and testing for proper fuctioning complete all as specified and directed by Engineer-in-Charge.
Note : The cost of components / suitable spare parts, suitable wires, lugs, nuts, bolts and washers required for control wiring shall be included in quoted rate.
2
-
-
Supply and fixing in replacement of control PCB card complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of exhaust fan suitable for SMPS 15 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of IGBT suitable for SMPS 15 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of Relay suitable for SMPS 15 KVA complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of DC fuse holder suitable for SMPS 15 KVA complete all as specified and as directed.
2
-
-
Tracing out fault in 11 KV under ground cable with the help of tracing machine and rectifying the same with joints to restore the supply complete all as specified and directed.
Notes :
(i) Cable Joint kit shall be measured and paid seperately under relavent item.
(ii) Necessary earth work is included in quoted rates.
(iii) All other necessary arrengements suitable for locating the faults is deemed to be included in quoated rates.
(iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissiable on this account.
15
-
-
Opening of all electrical connections HT/LT from the bushings/terminal box of the serviceable distribution transformer, indoor/outdoor type from existing position/location, of any make & specifications, of capacity upto 315 KVA & loading the transformer with suitable crane and transporting the transformer to desired location given by Engr-in-Charge and re-assembling after shifting, connecting all eletrical/meachnical connections, commissioning of transformer on load after testing complete all as specified and as directed.
2
-
-
Opening of all electrical connections HT/LT from the bushings/ terminal box of the serviceable distribution transformer, indoor/outdoor type from existing position/location, of any make & specifications, of capacity upto 630 KVA & loading the transformer with suitable crane and transporting the transformer to desired location given by Engr-in-Charge and re-assembling after shifting, connecting all eletrical/meachnical connections, commissioning of transformer on load after testing complete all as specified and as directed.
2
-
-
Supply and fixing of HT Tape roll of size 100 mtr long complete all as specified and directed.
50
-
-
Supply, fixing commissioning and testing of Three Phase Over current Earth fault relay (Numerical) ADR 241A-18-250 vdc for outgoing 11KV VCBs complete all as specified and directed.
2
-
-
Supply and fixing of Spout suitable for existing VCB make & specifications as existing at site after taking down spout as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of Busbar 50cm x 10mm suitable for existing VCB make & specifications as existing at site after taking down busbar as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of Space heater suitable for existing VCB make & specifications as existing at site after taking down space heater as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of Thermostat suitable for existing VCB make & specifications as existing at site after taking down thermostat as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of PT suitable for existing VCB make & specifications as existing at site after taking down PT as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing of Boot suitable for existing RMU make & specifications as existing at site after taking down coil as exists at site complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of resin cast ring core protection Current Transformer of ratio 50/5A, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of resin cast ring core protection Current Transformer of ratio 40/1A, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU complete all as specified and as directed.
2
-
-
Supply and fixing in replacement of resin cast ring core protection Current Transformer of ratio 80/1A, Class 10P80, VA 0.1 or suitable for relay type W1C1, 50 C/S of RMU complete all as specified and as directed.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements