Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 50,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675155_2Tender No
8822/2024-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
COMPREHENSIVE MAINT OF DG SET ,AMF PANEL CONNECTED TO WATER SUPPLY OF VARIOUS LOCATION UNDER GE(U) BATHINDA
BOQ Items
Outgoing
(i) MCCB 200 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 200 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (vii) Hooter - 01 No
(viii) PROCOM UNIT (DGC6D) FOR control - 01 No
(ix)Extended Rotary handle - 01 No (x) engine start relay 12 V DC
-
-
-
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of AMF Panel outdoor type, 100KVA DG Set with alluminium busbar of capacity 250 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of four pole 200 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
1
-
-
INCOMING from 100 KVA
(i) MCCB 160 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders Link - 01 Set
(iii) Extended Rotary handle - 01 No
(iv) Power Contactor 160 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 200/5A CL-1.0 10 VA - 06 Nos
(vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch four pole 200A for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 160 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 160 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle - 01 No (x) engine start relay 12 V DC
-
-
-
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of Automatic transfer switch with AMF controller Procom DGC6D and Inbuilt battery charger 12 V 10 A of capacity 40 A four pole type with sheet metal enclusure for DG set of 25KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .HAVEELS CAT PART NO IHRFBAE040
6
-
-
S&F in replacement of Automatic transfer switch with AMF controller Procom DGC6D and Inbuilt battery charger 12 V 10 A of capacity 63 A four pole type with sheet metal enclusure for DG set of 40KVA .The automatic transfer switch shall transfer the load to DG set in case of mains supply failure and changeover back the mains when commercial suppply restored automatically as directed .HAVEELS CAT PART NO IHRFBAE063
5
-
-
S&F in replacement of AMF Panel outdoor type, 200KVA DG Set with alluminium busbar of capacity 500 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of Four pole 400 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
1
-
-
INCOMING from 200 KVA
(i) MCCB 400 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders link- 01 Set
(iii) Extended Rotary handle - 01 No
(iv) Power Contactor 300 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 400/5A CL-1.0 10 VA - 06 Nos
(vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch 400A four pole for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 400 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 300 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 24V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle - 01 No
(xii) Engine start Relay=01 NOs
-
-
-
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
S&F in replacement of AMF Panel outdoor type, 62.5KVA DG Set with alluminium busbar of capacity 200 Amps, TPN powder coated (coloured ) heat shrinkable sleeves, 3mm CRCA sheet steel enclosure duly powder coated and inbuilt on load change over switch of four pole 125 Amps.The amf panel should mount on angle iron of 3Ft height of size 50x50x6mm includiing PCC and necessary excavation consisting the following:-
3
-
-
INCOMING from 62.5 KVA
(i) MCCB 100 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Spreaders Link - 01 Set
(iii) Extended Rotary handle - 01 No
(iv) Power Contactor 125 Amp FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 Volts AC - 01 No
(vi) C.T. 100/5A CL-1.0 10 VA - 06 Nos
(vii) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Indicating lights (Red-2, Yellow-2. Green-2) (ix) Control MCB 6A SP 10 KA C curve (x) VMR - 01 No
(xi) In built on load change over switch four pole 125A for bypassing of AMF panel - 01 No
-
-
-
Outgoing
(i) MCCB 100 Amp microprocessor release type Four Pole ,Breaking capacity 36 KA,ICS=100% of ICU,adustable overload setting from 0.4 to 1.0 x In,Adustable short circuit setting from 1.5 to 8xIr - 01 No (ii) Power Contactor 125 Amps FP AC1 Duty with 2 NO and 2 NC Aux block coil voltage 220 V AC - 01 No
(iiI) AMF RELAY CARD 01 Nos (iv) BATTERY CHARGER 12V, DC, 10A - 01 No
(v) Emergency stop P.B - 01 No
(vi) Digital MF meter with 485 Port - 01 No for parameters VLL,VLN,A,PF,F,HOURS,A PEAK ACCURACY CLASS 0.5 (viii) Control MCB 6A SP 10 KA C Curve (ix) Hooter - 01 No
(x) PROCOM UNIT (DGC6D) FOR control - 01 No
(xi)Extended Rotary handle - 01 No
(xii) Engine start Relay -01 Nos
-
-
-
Note:- The four pole Changeover switch connection as given below 1) The 1st incomer of changeover will connected to common output of AMF panel from suitable size of bus baar.2) The 2nd incomer of change over switch will common to commercial supply to incomer of AMF with MCCB with suitable size of bus baar.
-
-
-
M&L for Earthing complete with slotted galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion.
30
-
-
Labour only for laying of LT cable of any size which issued by MES under Sch B as directed by Engineer in charge .Note :- The LT cable will be issued to contractor under Sch B.
910
-
-
Taking out of old LT cable of any size as directed
910
-
-
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts/stays etc not exceeding 10 sqm on plan and getting out in soft / loose soil.
54
-
-
Returning, filling in,including spreding ,levelling ,watering and well ramming in layers not exceeding 25 cm thick complte all as specified and as directed by Engineer-in-charge
31
-
-
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all specified and as directed.
22
-
-
M&L for Sand cusioning of river sand for XLPE cable with screened & washed sand & punning to provide a required cover.
16
-
-
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250
mm x 150mm x 40mm as directed
1300
-
-
Repair/overhauling of self starter i/c replacement of carbon brusses, bearing, bushes, rewinding of armature and field etc. and warnishing complete all as directed for the following capacity :-
-
-
-
12 Volts
6
-
-
24 Volts
4
-
-
Supply & Fixing in repair of DC 12V Solenoid Coil left/right suitable for DG Set
2
-
-
Supply & Fixing in repair of DC 24V Solenoid Coil left/right suitable for DG Set
2
-
-
Labour only for fixing of material issued to contractor Under Sch B as directed by engineer in charge as under :-
-
-
-
Dynamo 12V/24V
3
-
-
Fan Belt
5
-
-
Contactor 4 pole of various capacity
22
-
-
Contractor coil of various capacity
14
-
-
Autocut Electrical Battery Charger Unit DC 12V/24 V 10 A SMPS
25
-
-
Voltage Monitor Relay
3
-
-
Timer AC/DC on Delay
5
-
-
Indicating lamp set RYB
75
-
-
Engine Start Relay, 12 /24 VDC,
3
-
-
Annunciator Units, For Fault
5
-
-
DC ammeter and Voltmeter
11
-
-
6x1.5 Sqmm Multistrand Copper Conductor Control Cable for DG Set to AMF Panel
300
-
-
Single Phase Preventer ,3 Way Selector Switch,DG Set Starting Current Coil 4 ST SWITCH 12/24 V,Oil Pressure sensor For DG set ,Emergency Stop Swith,CT 200/5
49
-
-
AMF Controller(PROCOM UNIT)
15
-
-
AVRs of various capacity
10
-
-
Fuel Pipe
20
-
-
Coolent
450
-
-
Engine oil
420
-
-
DG set canopy Hinjes
60
-
-
Battery Terminal of Dg set
50
-
-
Relay card for amf panel
10
-
-
Battery Distilled Water
200
-
-
DG set controller cummins PSO600
2
-
-
MCCBs of vaious sizes
20
-
-
Note: The contractor shall deposited the old material retrieved from item no 01 to 19.24 to AGE EM store yard by his own arrangement without any financial benefit and shall maintain the record for the same as specified by Engr-In-Charge and GE.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%