Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_658144_2Bid Award Id
ViewTender No
TOKEN NO GE ABH-18/24-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplyand fix , in repair Constant Current LED Driver , power 45W ,Cat Ref SODRVIL-45/1400, IS 15885(Part2/sec 13) ,IP 66 SELV Out put operating Voltage 16-30Vdc, model :SO3011400PPB,LIEP1UC26 all as specified and directed ,Make : Crompton or equivalent.
25
-
-
Supply and fix , in repair surge protection device (SPD) of capacity SP10 KV, 5 KA, IB1 12140430 complete all as specified and directed. Make: Crompton or equivalent.
32
-
-
Supply and fix , in repair, surge protection device (SPD) of capacity 8 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. Make: Havells/Philips/CG/syska/Bajaj/
100
-
-
Supply and fix , in repair surge protection device (SPD) of capacity 5 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. Make: Havells/Philips/CG/syska/Bajaj/
150
-
-
Supply and fix , in repairLED driver 20/25 W LED street light fitting complete all as specified and directed by engr-in-charge.
150
-
-
Supply and fix , in repair LED driver 30 W LED street light fitting complete all as specified and directed by engr-in-charge.
150
-
-
Supplyand fix , in repair LED driver 60/90W W LED street light fitting complete all as specified and directed by engr-in-charge.
320
-
-
Supply and fix , in repair LED driver 120 W LED street light fitting complete all as specified and directed by engr-in-charge.
20
-
-
Supply and fix , in repair LED Strip for 20/25W LED street light luminaries complete all as specified and directed by engr-in-charge.
20
-
-
Supply and fix , in repair LED Strip for 30W LED street light luminaries complete all as specified and directed by engr-in-charge.
20
-
-
Supply and fix , in repair LED Strip for 60/90W LED street light luminaries complete all as specified and directed by engr-in-charge.
100
-
-
Supply and fix , in repair LED Strip for 120W LED street light luminaries complete all as specified and directed by engr-in-charge.
20
-
-
Taking out faulty underground 1100 volt grade LT cable of different sizes from 6 sqmm to 330 sqmm 3.5 core/4/2 core by excavation and removing bricks of any size and relaying in the same trenches or rerouting after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed.
Note:1. New LT cable replace with fault portion ,joints shall be measured and paid separately under respective items of the schdule.
2. Retrived old serviceable bricks will be laid in trenches for cable protection. if extra bricks and sand required at site shall be measured and paid separately under respective items of the schdule.
3. Earth work and excavation will be measured and paid separately under respective items of the schdule.
220
-
-
M&L for cutting/trimming of branches of tree tuching/aproaching LT/HT over lines/street light of various spans(having 40 to 45 mtr) up to 3 mtr width on each side from difrent site of grith up to 10 cm with cutting equipments hacksaw,axe,ladders,rope and safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the ares complete all as specified and directed by Engineer-in-charge.
350
-
-
M&L for re-streaching of loose LT/HT over head line,aluminium conductor,GI guard wires and credals etc complete at various location and diffrent span of 2 to 7 conductors with the help of rope and pullar including provision of short length of conductors as jumpers and duly binding with existing insulators etc complete all as specified and directed by Engineer-in-charge.
50
-
-
M&L for preparation old painted surfaces with synthetic enemel paint to LT steel tubbular pole 8.5/9/8.0 mtr long including clamps,brackets,chanel,cross arms,bracing support,pipe of support for cable and swan neck etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and as directed.
Note: Pole number shall be marked with white enamel paint over a base of size 20cmx20cm on prepared with two coats of black enamel paint on pole surfaces.
290
-
-
Supply, fixing and streching of Aluminium conductor steel rainforced (ACSR) of required size or guage on LT/HT poles fixed on insulators and binding with & including binding wire complete all as specified and directed by Engineer-in-charge.
1
-
-
S&F in replacement of pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100 mm height,65 mm dia for 1100 volts grade complete all as sprcified and as directed.
20
-
-
S&F in replacement of shackle type,porcelain,vitreous,white,brown or green insulator 1100 Volts LT of size 100 mm high and 115 mm dia including galvanised mild steel straps of size 31x5 mm,washers,insulator bolts 14 mm dia,washers and nuts etc complete all as sprcified and as directed.
12
-
-
S&F in repair loop type insulator, vitrous porcelain, white brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete all as specified and directed by Engineer-in-charge.
8
-
-
S&F in replacement of galvanised stay wire with stay strand 7/4mm complete all as specified.
0.25
-
-
Supply and fix stay assembly complete with accessories as shown electrical plate No. 1 of SSR Part I for LT poles with 16 mm dia stay rod including excavation,PCC work and connected stay assembly accessories such as stay rod,insulator,clamps etc.,complete all as specifed and directed.
10
-
-
Supply and fix inreplacement of cradles,hexagonal/rectangular,fabricated with Galvanised steel wire 3.15 mm or 4 mm dia, for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge.
0.25
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 4 core and including provision of gland plates, gland and aluminium lugs to bothe ends of cable connections complete all as specified
100
-
-
All as per item No 27 above herein before but the size cross-sectional area 10 sq. mm 4 core
150
-
-
All as per item No 27 above herein before but the size cross-sectional area 16 sq. mm 4 core
160
-
-
All as per item No 27 above herein before but the size 25 sqmm 4 core
170
-
-
All as per item No 27 above herein before but the size 35 sqmm 4 core
160
-
-
All as per item No 27 above herein before but the size 50 sqmm 4 core
170
-
-
All as per item No 27 above herein before but the size 70 sqmm 4 core
140
-
-
All as per item No 27 above herein before but the size 95 sqmm 4 core
160
-
-
All as per item No 27 above herein before but the size 120 sqmm 4 core
170
-
-
All as per item No 27 above herein before but the size 150 sqmm 4 core
120
-
-
All as per item No 27 above herein before but the size 185 sqmm 4 core
90
-
-
All as per item No 27 above herein before but the size 240 sqmm 4 core
80
-
-
All as per item No 27 above herein before but the size 300 sqmm 4 core
80
-
-
Supply and fix in replacement steel tubular swaged poles complete with cast iron base plate, taper plug, bolts,nuts & screws as specified type 410 SP-31, 9.0 meters long, complete all as specified.
3
-
-
Supply and fix in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long)
1
-
-
Supply and fix in replacement Steel tubular swaged poles with double sided provision of streetlight brackets with Pipe made of GI medium grade , length up to 1.5 mtr, complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 (7.0 miters long) complete all as specified.
3
-
-
M&L for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggrigate for foundation of pole etc complete all as specified.
6
-
-
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggrigate in foundation, roof,kerb or mud stops, rounded or chamfered on edges and coping to pole complete all as specified.
1.5
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core and including provision of gland plates, gland and aluminium lugs to bothe ends of cable connections complete all as specified
50
-
-
All as per item No 45 above herein before but the size cross-sectional area 16 sq. mm 2 core
100
-
-
All as per item No 45 above herein before but the size 25 sqmm 2 core
100
-
-
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil.
354.38
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.
170.1
-
-
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
42.53
-
-
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover.
141.75
-
-
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
2
-
-
M&L for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed.
12
-
-
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed.
12
-
-
S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
6
-
-
S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
6
-
-
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat.
14
-
-
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
10
-
-
Supply and fixing MCCB TPN/TP 350 Amps 415 Volts of braking capacity 36 KA of 3 pole confirming to complete taking down old unserviceable one and making necessary connections including all provisions for fixing in panel compartments as existing using necessary links of suitable metals and cleaning the terminals with CTC solutions complete all as specified and directed. Make : Havells/Legrand/IndoAsian (optimum 2.0)/Schneider/HPL/Standard
1
-
-
All as per Ser Item No 59 but 250 Amps with braking capacity 25 KA.
1
-
-
All as per Ser Item No 59 but 200 Amps with braking capacity 25 KA.
1
-
-
All as per Ser Item No 59 but 125 Amps with braking capacity 25 KA.
1
-
-
All as per Ser Item No 59 but 630 Amps with braking capacity 50 KA.
1
-
-
All as per Ser Item No 59 but 400 Amps with braking capacity 36 KA.
1
-
-
All as per Ser Item No 59 but 500 Amps with braking capacity 50 KA.
1
-
-
All as per Ser Item No 59 but 160 Amps with braking capacity 25 KA.
1
-
-
All as per Ser Item No 59 but 100 Amps with braking capacity 25 KA.
1
-
-
All as per Ser Item No 59 but 63 Amps with braking capacity 25 KA.
1
-
-
Supply and fixing MCB TPN 100 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand
1
-
-
Supply and fixing MCB TPN 63 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand
1
-
-
Disconnecting of LT supply and opening bus bar chamber/ cable box chamber of outdoor/indoor LT panel, removing of burnt out lugs,Lt switch gears/MCCB/MCB of any capacity and size and cleaning of bus bar and contact terminals with CTC solutions, insulating the bus bar by taping color codes and making connections complete with necessary nut,bolt,washeres,timbles and links of existing size and refixing all switchgears after repair/maint/servicing complete all as specified and directed.
8
-
-
Supply and fixing aluminium lugs suitable for cable of size 10 to 16 sqmm complete all as specified and directed.
84
-
-
Supply and fixing aluminium lugs suitable for cable of size 25 sqmm complete all as specified and directed.
80
-
-
Supply and fixing aluminium lugs suitable for cable of size 35 sqmm complete all as specified and directed.
87
-
-
Supply and fixing aluminium lugs suitable for cable of size 50 sqmm complete all as specified and directed.
85
-
-
Supply and fixing aluminium lugs suitable for cable of size 70 sqmm complete all as specified and directed.
78
-
-
Supply and fixing aluminium lugs suitable for cable of size 95 sqmm complete all as specified and directed.
74
-
-
Supply and fixing aluminium lugs suitable for cable of size 120 sqmm complete all as specified and directed.
57
-
-
Supply and fixing aluminium lugs suitable for cable of size 150 sqmm complete all as specified and directed.
14
-
-
Supply and fixing aluminium lugs suitable for cable of size 185 to 300 sqmm complete all as specified and directed.
12
-
-
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
2
-
-
M&L for test point terminal box made of gunmetal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw for lighting conductors complete all as specified and directed.
2
-
-
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI earth strip of size 32 x 6 mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI strip upto 7.5m including testing consider in this item).
2
-
-
Re-fixing the GI/copper strip of any size with new nut, bolts, washer, replace broken shuddles for lightning protection for hanger's/buildings and brazing work on joints all as required and direceted.
40
-
-
Supply and fix street light timer enclosed out door box 3 phase,40 Amps, 3 pole , 415 volt Astronomical time switch complete with all accessories i.e MCB 40 Amps TPN, Astronomical time switch 24 Hrs, contactor,fuse unit,indicator lamp,rotary switch and in coming and out going connector etc including prewired complete all as specified. Make: IndoAsian Cat: TL040ASO and equivalent in make Havells/ L&T/CG/Standard/Siemens
1
-
-
M&L for cutting the bushes, M&L for cutting,trimming bushes,weed/tidy plants to bring in a cleaned position and level the area around/inside near E/M installation and making good of LT panel/two f,four pole structure/substation/transformer yard without disturbing installed accessories/equipments by using cutting equipments hacksaw,axe,ladders,sword,trimmer for well groomed with safety measures etc including disposal of trimmed branches 100 mtr away inside the cantonment area and cleaning the areas complete all as specified and directed by Engineer-in-charge.
250
-
-
Demolishing the broken earth pit chamber and constructing new earth pit chamber and PCC chamber cover only complete as per SSR Pt -I of 1996 including new wire mesh funnel all as directed.
15
-
-
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 160 amps complete all as specified and directed Make: Make-Indoasian or equvalent of Legrand/L&T/Standard/Havells/ Schneider)
1
-
-
All as per Ser Item No 88 but 250 Amps rating
1
-
-
All as per Ser Item No 88 but 200 Amps rating
1
-
-
All as per Ser Item No 88 but 400 Amps rating
1
-
-
Supply and fix in repair hot moulded FRP looping /Junction box size 280 mmx200 mm for street light poles with locking arrangement and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting incl controlled MCB SP-10 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe IP-65, weather,vermin proof,dust and water proof complete with two nos cables entry incl gland of standard size with suitable size mild steel clamps to fixed on pole complete all as specified. Make-Neptune/Hensel/Sintex
80
-
-
M&L for fabrication of cross arms bracings supports,clamps and back plates,iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge.
Note: Exosed steel surface shall be treated with two coats of aluminium paint over a coat of redoxide primer and unexposed surface of steel sectioons shall be appied one coat of redoxide primer, the quoted rate shal be deemed inclusive of the above provn.
0.65
-
-
M & L for removing old unserviceable LT OH line jumpers/connectoers/taps/sleeves and insulators of any type and size rejumpering the same by supply and fixing suitable size of ACSR conductor as jumpers replacing obtained serviceable insulators and testing the OH lines after reapir/replacement and maint of jumpers all as specified and directed.
Note: Jumpers set of two to Six to be replaced in one job at one pole point including in this item. Insulators shall be measured and paid separately under relevent item of the schedule.
50
-
-
M&L for removing connections of faulty cable from both ends of LT terminaton from panel/transformer after meggaring and confirm the faulty cable all as specified and directed and finding the spot of the cable faulty position with any other mechanism like cable fault locator or manual with necessary earth work made and remove the cable from the trench and jointing the cable to serviceable condition after necessary meggaring values obtain and shifting or relaying the cable against relavent items of the schedule all as specified and directed by Engr-InCharge.
Note: 1. Earth work for the cable removing. laying and necessary joint material measured and paid separately under relevent items of the schedule.
2. skilled operator/instruments involved for positioning the cable fault location is deemed to be included in the rates quoted.
4
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable of size 2 core 10 sqmm nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed by Engr-In-charge.make- Havells/Plaza/Finolex/Kalinga/Kei/Anchor.
90
-
-
All as per Item No 96 above here-in-before but 2 core 6 sqmm complete all as specified and directed.
90
-
-
Supply and fix LED type street light fitting 60 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 including GI pipe medium grade 40 mm dia bracket bend in 120 degree and clamps,nuts,bolts etc with all acessories complete all as specified and as directed. Make; Bajaj Cat No; BRTFG60W LED or equivalent in Philips/CG/Havells
18
-
-
Supply and fix LED type street light fitting 70 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 including GI pipe medium grade 40 mm dia bracket bend in 120 degree and clamps,nuts,bolts etc with all acessories complete all as specified and as directed. Make; Bajaj Cat No; BRTFG60W LED or equivalent in Philips/CG/Havells
20
-
-
Supply and fix LED type street light fitting 35 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 including GI pipe medium grade 20 mm dia bracket bend in 120 degree and clamps,nuts,bolts etc with all acessories complete all as specified and as directed. Make; Bajaj LED or equivalent in Philips/CG/Havells
11
-
-
Supply and fix LED type Flood light fitting 70 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 including GI pipe/channel and clamps,nuts,bolts etc with all acessories complete all as specified and as directed. Make; Syska or equivalent in Philips/CG/Havells/Bajaj.
11
-
-
All as per Item No 101 above here in before but Flood light fitting 100 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 complete all as specified
15
-
-
All as per Item No 101 above here in before but Flood light fitting 120 watt pressure dia cast aluminium housing LED street light luminaries with IP 66 complete all as specified
20
-
-
S&F cable end jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 50 sqmm with provision of lugs/thimbles/aluminium jumpers for OH/UG connections. Make: Dension/3M
10
-
-
All as per item No 104 above here in before but joint of size 70 sqmm to 95 sqmm
3
-
-
All as per item No 104 above here in before but joint of size 120 sqmm to 150 sqmm
3
-
-
All as per item No 104 above here in before but joint of size 185 sqmm to 240 sqmm
3
-
-
All as per item No 104 above here in before but joint of size 300 sqmm
2
-
-
M&L for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 6 to 25 Sqmm 2 Core in repair. Make : Dension/Raychem.
2
-
-
M&L for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 10 to 50 Sqmm 3.5 Core in repair. Make : Dension/Raychem.
3
-
-
M&L for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 70 to 150 Sqmm 3.5 Core in repair. Make : Dension/Raychem.
3
-
-
M&L for Straight through cold shrink type joint 1100 Volt complete with jointing material and accessories suitable for 185 to 300 Sqmm 3.5 Core in repair. Make : Dension/Raychem.
2
-
-
M&L for Servicing ACB by taking out Air circuit breaker of capacity 400-1250 Amps from LT panels cleaning all parts internally and externally checking of the proper tenstion of mechanical springs and switching mechanisim, tightning of connections of moving ,fxing contacts, floating contracts, servicing of motors and charging system and refixing it on its original position and testing of control wiring to operational complete all as specified and directed.
2
-
-
S&F in repairs of shutter assembly suitable for 3/4 pole ACB up to 630/800 Amps capacity complete all as specified and directed
2
-
-
S&F in repairs of arc chute (set of 3) suitable for 3/4 pole ACB up to 630/800 Amps capacity complete all as specified and directed
2
-
-
S&F in repairs of floating isolating contact (set of 3) suitable for 3/4 pole ACB up to 630/800 Amps capacity complete all as specified and directed
2
-
-
S & F Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete all as specified and directed Make; Bajaj BGAV 302 LED
1
-
-
Repair/maint and servicing of High mast light motor and pully with gearing system and repalcement of oil for lubrication of pulley and replacement of minor repairs like nut,bolts and washers,belt and provision of suitable handle for manual operation of High mast light fitting complete all as specified. Note: Winding of motor measured and paid separately
1
-
-
M&L for copper winding to high mast light pulley motor 1 HP and insulating the winding with good quality material by taking unserviceable winding and repalcement of minor spares like coupling,PVC blower fan blades complete all as specified and directed
1
-
-
S&F in repairs to SWG rope wire for high mast light frame up and down and replacement of rope/wire suitable size as existing or not less than SWG 4 gauge size complete all as specified and directed.
6
-
-
Supply and fixing LED Post top lantern fittings 50 Watt decorative indirect post top for 360 degree garden & landscape lighting with IP-65 resistant to impact and corrosion anti glare and uniform distibution Make; Crompton or equavalent in Bajaj/Philips/Syska/Havells/Halonix
10
-
-
M & L for preparation of old painted surfaces of LT panel size (moe than 1.0m,x1.0mx0.5m to 2.0x1.5mx0.8m) and applying spray painting with two coats of synethetic enamel paint over a coat of red oxide primer of existing color for outdoor/indoor panel board, outer & inner side and scraping out the old paint surfaces of existing panel boards complete all as directed by Engineer-in-charge including white wash to panel foundation/PCC base complete all as specified and directed.
10
-
-
Supply and fix in replacement digital voltmeter 0 - 500 Volts
3
-
-
Supply and fix in replacement digital ammeter 0 - 500 Volts
3
-
-
Supply and fix in replacement neon indicating lamp (Red, Yellow, Blue)
10
-
-
Material and labour in repair to Timer switch throughly check contractor and connections of time switch along with protection relays repair for check seriviceability by replacing minor spares like connectors,internal wiring and relays deemed to be include. Note: Spares like power contactor,time switch measured and paid separately.
3
-
-
Supply and fixing analog time switch with battery backup 3P module, 24 Hours program programmable every 15 Min backup of 100 hours current capacity 16 A with changeover
1
-
-
Digital time switch programmable every 1 min with backup of 6 years 28 memory locations current capacity 16 A weekly program with 1 changeover total 28 programs
1
-
-
Astronomical programmable every 1 min backup of 6 years, 28 memmory locations, current capacity 16A with 1 change over total 28 programs
1
-
-
Power contactors 3 phase current rating 40 Amps coil voltage 24 V AC 1 NO + 1 NC
1
-
-
S&F PVC line separator suitable for 3 phase 4 wire and 02 wire of street light of LT line all as directed.
20
-
-
Taking down care fully existing out door/indoor type Old PCC floor mounted LT panel board of size (moe than 1.0m,x1.0mx0.5m to 2.0x1.5mx0.8m) after disconnecting all type of incoming and out going cables, removing carefully switch gears and measuring instruments for reuse/refixing of serviceable items and repair/maint and servicing of existing panel by replacing hinges,switch gear compartments with rubber sheal,locks, nuts,bolts and washers and provn of danger notice boards, indicators of three nos with colour coding and three phase digital voltmeter 0-500V, Ammeter 0-800A with suitable CT,s and selector switch and tape insulation sleeves the three phases and neautral with colour coading and painted with two coats powder coating primer and also reconnecting all cables in same position with suitable glands,gland plates,aluminium lugs, nut bolts and washers. Refixing serviciable switchgears obtained from the panel. Note: Supply and fix Switch gears against unserviceable measured and paid separately with relevent items of this schedule.
3
-
-
M&L for street light bracket made to shape from 40mm dia length 1.5m GI Pipe medium grade incl two number of clamps made from 50 x 6 Flat iron nut bolts complete all as directed
3
-
-
Materla and labour for disconnecting faulty/burnt end portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at panel boards and preparing fresh terminals with suitable size of thimbles,lugs and glands or gland plates as suitable of any size and number of cables incoming out going to panel board`
6
-
-
M&L for emergency maintenance work of HT/LT over head line/UG cable line during breakdown by deploying skilled labour and electricians at faulty site having gang of mimimum 04 persons including transportation and other tools and plant required at site for fault rectification.
Note: Contractor or his rep shall come to the site of breakdown within two hours of notification of breakdown. Incase the contractor or his rep shall not come to the site of breakdown and start attending breakdown with in two hours of notification a penalty of Rs 500/- per fault per hour shall be imposed over contractor and same deduct from his dues
4
-
-
Supply and laying in replacment of synthatic rubber insulating mat of size 2mx1mx2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS-15652-2006(superseding IS-5424) suitable for shock safety complete all as specified and directed.
2
-
-
Supplied and fixed Miniature circuit breaker (MCB), single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as directed by Engr-in-charge.
28
-
-
Supply, install, testing and commissioning of CPRI approved, factory made, LT panel board cubical, outdoor, type, floor mounted double door, 3 phase, 4 wire 50 Hz, 415 volts . The panel board size 1.2 X 1.2 X 0.6 mtr shall be made 3.15 mm thick CRCA sheet load bearing members and 16 SWG (1.6 mm thick) for door covers and internal portions shall be powder coted both sides. Base frame of the panel shall be made of ICMC channel of size 50X50X6 mm, duly grouted on plateform made of brick work in CM (1:2:4), 15 mm thick plastering in CM (1:6) having minimum height 600 mm. The panel shall be provided with separate compartment of each switch gears with hinged door, including inter locking with switch gears. The panle board shall be suitable for AC, 415 volts, 50Hz, 3 Phase, 4 Wire supply completed with epoxy coated (400 Amp) rated high conductivity Aluminium bus bar supported with DMC/ AMC barriers and colour cotted heat shirnkable sleve and F class insulator pre-wired with copper cable, 1100 volts of danger notice board on front of the panel and degree of protection is IP 54. The panel shall be complete with illustraction such as LED phase indicating lamps and CTs including external aluminium strip of rating of incommer (200 AMP,incl 02 Nos change over switch each 250A ) and outgoing as per rating of MCCBs including aluminium legs to connected the cable etc. Note:- 1. Design/ drawing / bom of the panel board showing the dimension incl accessories is to be obtained from panel board manufacturer / supplied an is to be got approved from GE before placing fianl order to the manufacturer / suppliers. 2. Anything missing out in the technical specification but technically required for efficient working is deemed to be included in qouted rates. i). INCOMING:
(a) Change over switch 250A,415 Volts 4 pole, L & T (02 Nos)
a) MCCB 200 A,415 Volts 4 pole, 36 KA-(Adj Thermal Mag sett)
b) Indicator lamp LED type (set of three Red,Yellow,Blue)
ii) OUTGOING
a) MCCB-100A (04 Nos)
b) MCCB-3P-63A (03 Nos)
g) MCB-DP-40A
j) MCCB-100A (Spare)
k) Aluminum bus bar 400 Amp, reqd length-04 nos
l) Digital Volt meter & Ammeter with suitable CT's each
1
-
-
Supply installation, commissioning and testing including providing all necessary electrical connection, LT Junction/Bus bar Chamber box, outdoor type CPRI approved (IP-54), factory made out of 2.5 mm thick MS sheet of size 0.80mx 0.60 mx 0.60 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc complete all as directed by the Engr-in-Charge and comprising of the following accessories including taking down unserviceable box:-
(a) Aluminium bus bar suitable for 400 Amp 0.5 mtr long fixing on suitable capacity and size insulators ---04 nos
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements