Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date20 Feb 2025
Closing Date14 Mar 2025
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Swing motor for window type AC / split type AC of capacity upto 2.0 ton as per existing make LG/Voltas/whirlpool/Carrier complete all as specified and directed.

4

-

-

... More
S&F Running capacitor 50+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon/Havells

10

-

-

... More
S&F Running capacitor 45+2 to 6 MFD (ISI Marked) 440VAC for window AC/ split AC 1.5/2 Ton fixed in repair all as specified and directed.. Make: Epcos/Tibcon.

6

-

-

... More
S&F Running capacitor 36+2, to 6 MFD (ISI Marked) 440VAC for window AC 1.5/2 Ton fixed in repair all as specified and directed. Make: Epcos/Tibcon.

5

-

-

... More
S&F Front grill of window AC, capacity 1.5/2 ton suitable for make LG/ Carrier/ Sidwal/ Whirlpool as per existing fixed in repair complete all as specified and directed.

3

-

-

... More
S&F Condensing fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed. MAKE -LG/VOLTAS/CARRIER

5

-

-

... More
S&F Blower fan of window type AC of capacity 1.5/2 ton as per existing fixed in repair complete all as specified and directed.

3

-

-

... More
S&F in replacement single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps with breaking cap 10kA complete all as specified and directed. Make: L&T, Havells, standard, Indoasian

10

-

-

... More
Servicing of window type AC/split type AC of capacity 1.5/2 ton of any make at site with complete washing/ removing of dust from blower fan and necessary oiling the blower motor complete all as specified and directed.

81

-

-

... More
S&F in replacement of unsv Blower Motor (ISI marked) as per existing capacity for window type AC complete all as specified and directed. Make: Air master /AUE/AE

4

-

-

... More
S&F in replacement of unsv 4way reversing valve kit to maintain the desired temperature of cooling system of window type AC /split type AC of capacity 1.5/2 Ton as per site requirement including gas charging complete all as specified and directed.

4

-

-

... More
S&F in replacement of unsv PCB circuit Hot & cold for window type AC complete all as specified and directed. Make- LG /Voltas

3

-

-

... More
S&F in replacement of unsv condensing coil for window type AC of capacity upto 2 Ton including gas charging complete all as specified and directed.

2

-

-

... More
S&F Copper pipe of dia 1/4 inch fixed in repair complete all as specified and directed.

30

-

-

... More
S&F Copper pipe of dia 3/8 inch fixed in repair complete all as specified and directed.

20

-

-

... More
S&F Copper pipe of dia 1/2 inch fixed in repair complete all as specified and directed.

30

-

-

... More
Taking down defective split type AC of any capacity/make after disconnecting electric connections and transporting to workshop from site ,dismantling the AC and taking out burnt rotary / reciprocating compressor unit from AC and replacing the same with new compressor of existing make including gas charging and testing complete all as specified and directed.

5

-

-

... More
All as per ser item No 31 here in before but for split type INVERTER AC any capacity.

2

-

-

... More
Taking down defective indoor Unit for Split AC 1.5 / 2Ton and replacing the same with new for existing make of AC complete all as specified and directed.

2

-

-

... More
S&F in replacement of PCB circuit hot and cold to split type AC 1.5 /2 ton for existing makes of AC complete all as specified and directed.

6

-

-

... More
S&F in replacement of PCB circuit for INVERTER AC hot and cold for split type AC of capacity upto 2 Ton of existing makes of AC complete all as specified and directed.

4

-

-

... More
S&F in replacement Blower Motor (ISI marked ) of split type AC upto 2 Ton capacity as per exisitng specification complete all as specified and directed.

4

-

-

... More
S&F in replacement condensor fan Motor (ISI marked ) of split type AC upto 2 Ton capacity as per exisitng specification complete all as specified and directed.

7

-

-

... More
S&F in replacement of UNSV Remote control with two AAA battery for split type AC of capacity 1.5 ton /2 ton suitable for make of LG/ Carrier/ Sidwal/ Whirlpool as per existing complete all as specified and directed.

3

-

-

... More
S&F Insulation material for copper pipe outer covering 25mm thick fixed in repair complete all as specified and directed.

90

-

-

... More
S&F in replacement condensing fan blade for split type AC of capacity upto 2 Ton as per exisitng size complete all as specified and directed.

6

-

-

... More
S&F in replacement Blower for split type AC of capacity capacity upto 2 Ton complete all as specified and directed.

4

-

-

... More
S&F PVC round sheathed copper conductor cable of size 2.5 Sqmm 3 core fixed in repair complete all as specified and directed. Make - Havells/ Plaza/ Polycab

90

-

-

... More
Supply & Charging Refrigerant R -134A complete one time for top up or making full qty as per pressure requirment of plant and testing for any leakage and rectifying the same all as specified and directed.

55

-

-

... More
Supply & charging Refrigerant R-22 to Air conditioner (window type /split type) of any capacity and make all as specified and directed. Make - Mafron

45

-

-

... More
Supply & charging Refrigerant R-32 to Air conditioner (window type /split type) of any capacity and make all as specified and directed.

8

-

-

... More
Supply & Charging Refrigerant R - 410 to Air conditioner (window type /split type )of any capacity and make complete all as specified and directed. Make :- Mafron

8

-

-

... More
Supply, install & testing of voltage stabilizer of capacity 4 KVA naturally air cooled copper wounded after disconnecting the unsv voltage stabilizer from machine for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170V to 270 V with stabized output of 230V accuracy +/-2.5% all as specified and directed, complete all as specified and directed. Make:-V Gaurd, Voltas, Bluebird, Microtek

13

-

-

... More
S&F submersible water lifting pump single phase 18W, 230 V ,50 Hz with connection lead for desert cooler including taking down old unsv lifting pump complete all as specified and directed. Make : Khaitan/ Cool Home/Orison.

270

-

-

... More
S&F in replacement of unsv Fan motor of desert cooler 1/7 HP with fan blade & frame legs single phase 230 V, 50 Hz incl fixing on desert coller with nuts bolts complete all as specified and directed. Make : Khaitan/ Cool Home/ AUE

158

-

-

... More
S&F in replacement Rubber pipe 15mm dia (ISI marked) heavy grade for desert cooler complete all as specified and directed.

120

-

-

... More
S&F in replacement unsv Wood wool pad of size 24" x 18" (set of 3) for desert cooler complete all as specified and directed.

310

-

-

... More
S&F in replacement unsv 3way PVC water distributor with suitable size nuts bolts and PVC elbow for water connection of desert cooler complete all as specified and directed.

76

-

-

... More
S&F in replacement unsv selector switch for desert cooler for three speed motor ISI Marked all as specified and directed.

60

-

-

... More
S&F in replacement unsv GI front show grill complete with selector switch, piano type switch etc. for desert cooler size as per site requirement complete all as specified and directed.

15

-

-

... More
S&F in replacement Plug top three pin 16 Amps 3Pin complete all as specified and directed .Make :-Anchor/Havells/Plaza .

30

-

-

... More
S&F in replacement Plug top three pin 6 Amps 3Pin complete all as specified and directed. Make : Anchor/PLAZA/Havells .

75

-

-

... More
S&F in replacement Ball valve of size 15mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed. Make: Prayag/ Seiko/ Jainko

13

-

-

... More
S&F in replacement PVC connection of size 15mm x 450 mm superier quality fixed in repair complete all as specified and directed. Make: Prayag/ Jainko/ Pearl

30

-

-

... More
S&F in replacement Stop valve of PTMT of size 15mm, any colour screwed for iron pipe (ISI marked) fixed in repair complete all as specified and directed. Make: Prayag/ Jainko/ Shakti

15

-

-

... More
Removing of desert cooler from site after disconnecting the electric connection and water connection, transporting to workshop, taking out rusted bottom and replacing with new bottom as per existing size of PGI sheet and transporting back to site, installing at site including electric and water connections and testing complete all as specified and directed.

10

-

-

... More
S&F in replacement unsv Side shutter of Desert cooler as per existing size of PGI sheet of desert cooler complete all as specified and directed.

15

-

-

... More
S&F in replacement Capacitor 4 MFD, 440V (ISI Marked) fixed in repair all as specified and directed. Make-Epcos/Tibcon / Havells

40

-

-

... More
S & Charging Refrigerant R 134 a/R-32 to Refrigerators of any capacity incl replacement of old filter and capillary copper tube as per existing size any length and make complete all as specified and directed.

15

-

-

... More
S&F in replacement unsv Starting relay for water cooler No CAJ -2612 / CAJ -34 / AHR 13 complete all as specified and directed. Make: Hi-Tech/Sriram /Ranutrial

25

-

-

... More
S&F in replacement unsv Starting capacitor of capacity 60/80 MFD, 80 / 100 MFD ,100/120 MFD (ISI Marked) 440V AC for water cooler complete all as specified and directed. Make-Epcos/Tibcon / Asian/ Havells

30

-

-

... More
S&F in replacement unsv Over load protector of any size and capacity for water cooler as per existing size complete all as specified and directed. Make: Hi-Tech/Sri Ram./ Ranutrial

23

-

-

... More
S&F in replacement unsv Thermostat switch of any size for water cooler complete all as specified and directed . Make: Denfos/Indofos/ Ranutrial

20

-

-

... More
S&F in replacement unsv Condensing fan blade for water cooler of any size any capacity complete all as specified and directed. (As per sample) .

10

-

-

... More
S&F in replacement unsv self closing push bib cock with wall flange heavy duty polished bright cast copper alloy chromium plated for water cooler of any size complte all as specified and directed. Make : Prayag .

30

-

-

... More
S&F in replacement unsv Rubber pipe 1.25 inch dia for waste water of water cooler complete all as specified and directed. .

50

-

-

... More
Removing of water cooler of capacity 60/120Ltrs from site after disconnecting electric & water connections and transporting to workshop, taking out burnt compressor and replacing with new compressor suitable for refrigerent gas R134a of the same make/ company of existing water cooler including gas charging and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed. Make - COPELAND/ VOLTAS / SHRI RAM/ SIDWAL

3

-

-

... More
All as per Ser item No 71 here in before but for water cooler of capacity 40/80Ltrs.

5

-

-

... More
All as per Ser item No 71 here in before but for water cooler of capacity 150/150 Ltrs.

2

-

-

... More
S&F in replacement unsv Blower motor of capacity 1/35 HP for water cooler of capacity 40/80, 60/120 Ltrs complete all as specified and directed. Make : Air master / AUE

15

-

-

... More
S&F in replacement unsv Blower motor of capacity 1/10 HP for water cooler of capacity 150 Ltrs complete all as specified and directed. Make :Air Master/AUE

10

-

-

... More
Supply & Charging Refrigerant R 134 a/ R 22 /R-32 to Water Cooler of any capaciy including replacement old filter and capillary copper tube as per existing size any length and make complete all as specified and directed.

23

-

-

... More
Removing refrigerator of capacity upto 195 ltrs from site after disconnecting electric connection and transporting to workshop , taking out burnt compressor and replacing with new suitable comperessor of the same make/ company of refrigerator, gas charging with R-134a/R-32 and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed. Make - LG/ VOLTAS / GODREJ

3

-

-

... More
All as per Ser item No 77 here in before but for refrigerator of capacity from 200Ltrs to 320 Ltrs.

5

-

-

... More
S&F in replacement unsv fan motor with fan suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.

4

-

-

... More
S&F in replacement unsv PCB Circuit suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.

2

-

-

... More
S&F in replacement unsv Bio Metal suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.

5

-

-

... More
S&F in replacement unsv heater suitable for Double door Refrigerator of make Whirlpool/ LG /VOLTAS/ Haier any capacity complete all as specified and directed.

5

-

-

... More
S&F in replacement unsv Thermostat switch for refrigerator complete all as specified and directed .Make:- Danfos/Indofos/Ranutrial

13

-

-

... More
S&F in replacement Starting relay of refrigarator of any capacity complete all as specified and directed.

14

-

-

... More
S&F Over load protector of refrigarator of any capacity fixed in repair complete all as specified and directed. Make:LG/Godrej/Hi-Tech

15

-

-

... More
S&F in replacement of cooling coil of refrigerator as per existing size with gas refilling complete all as specified and directed. Make of refrigerator: Godrej/Voltas/LG/ Whirlpool.

3

-

-

... More
S&F in replacement of condensing coil of refrigerator as per existing size with gas refilling complete all as specified and directed. Make of refrigerator: Godrej/Voltas/LG/ Whirlpool.

3

-

-

... More
S&F in replacement PVC round sheathed copper conductor cable of size 1.5 Sqmm 3 core complete all as specified and directed. Make : PLAZA/Shalimar/Havells

90

-

-

... More
S&F Thermostate switch for deep freezers of any capacity fixed in repair all as specified and directed.

5

-

-

... More
Removing Deep Freezer of capacity upto 400 ltrs of make Voltas/Bluestar from site after disconnecting electric connection and transporting to workshop, taking out burnt compressor and replacing with new suitable comperessor of the same make/ company of deep freezer, gas charging with R-134a/R-32 and testing for leakage and rectify the same if any including transporting back from workshop and installing at site complete all as specified and directed.

3

-

-

... More
S&F in replacement unsv Condensor fan motor for deep freezer of any capacity as per exiting size & make complete all as specified and directed . Make of deep freezer: voltas /blue star

3

-

-

... More
S&F in replacement vegitable tray for Refrigerator as per suitable size complete all as specified and directed.

3

-

-

... More
S&F in replacement bulb for Refrigerator as per suitable size complete all as specified and directed.

7

-

-

... More
S&F in replacement bottle support for Refrigerator as per suitable size complete all as specified and directed.

3

-

-

... More
Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 81,712.30 and any other reduction if any from quoted amount.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.