Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date20 Aug 2020
Closing Date22 Sep 2020
Tender Amount₹ 30,77,831 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Ges/pkt/t-22/2020-21 Certain Em Maintenance Works At 18 Fad Unchibassi Under Ge South Pathankot

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling/strip opening gear of micro main shaft drive for replacement of 2 Nos gun metal bushes having internal lining for oiling arrangement, replacement of all the nuts/bolts of bush side plate with L-key, bolts of size as per sample oiling/greasing of gear box including necessary cast iron repair to broken foundation which includes welding lathing and grinding complete all as specified and directed . (Crane capacity 2 to 5 Ton )

6

-

-

... More
Dismantling and refixing after repair brake shoe leather suitable any motion of flameproof EOT crane 2 to 10 ton cap complete all as specified and directed

12

-

-

... More
Dismantling/strip opening flameproof micro drive box complete with rectifier transformer arrangement, magnetic disc both side coupling for remotting both the side ends of driving shaft (Gear box coupling side and braking arrangement coupling side) making multi key arrangement on both the shaft and couplings (teeth system ) to avoid any kind of play in coupling and shaft including replacement of 4 Nos carbon bushes, replacement of 02 Nos gun metal bushes including making oiling arrangement in bushes and side covers of bushes/housing of micro drive re-assembling/testing complete (crane capacity up to 5 Ton) all as specified and directed by Engineer -in-charge.

4

-

-

... More
Dismantling/strip opening of up/down micro electric braking arrangement after un-screwing nuts, bolts washers, re-adjustment of braking springs, replacement of brake leathers, replacement of two Nos 440 volts any make brake coils, replacement of both gun metal bushes of shaft housing in brake box making oiling/greasing arrangement complete re-assembling and testing complete all as specified and directed .(Crane capacity 2 to 5 Ton )

5

-

-

... More
M&L for replacement coupling as per sample or approved by GE suitable for perfect alignment between flameproof motor and driven machine all as directed

6

-

-

... More
M&L for replacement of L Key bolts 1" x 10mm as per sample or approved by GE including applying moose threads found worn out and taking out broken bolts from body/housing of machine for 2 to 5 ton capacity flameproof EOT Crane complete all as specified and directed

50

-

-

... More
Dismantling/ lowering of burnt flame proof/weather proof three phase 440 volts , 50 Hz , 960 RPM , class F, 5 HP induction motor from platform complete including strip opening the same and rewinding with super enameled copper winding wire of same size /gauge as existing earlier complete including all backing material , insulation material and re- installation the same at original site complete all as specified and directed

5

-

-

... More
All as per item No-10 but capacity of motor 3 HP complete all as specified and directed .

3

-

-

... More
All as per item No-10 but capacity of motor 1 HP complete all as specified and directed .

3

-

-

... More
All as per item No-10 but capacity of motor 1 HP 1440 RPM complete all as specified and directed .

4

-

-

... More
All as per item No-10 but capacity of motor 1/2 HP complete all as specified and directed .

2

-

-

... More
M & L for of Power contactor 3 pole 16 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed

6

-

-

... More
M & L for of Power contactor 3 pole 40 Amp , 110 Volt as per sample or approved by GE complete all as specified and directed

3

-

-

... More
M & L for of Over load relay 1.7 to 2.4 Amp as per sample or approved by GE complete all as specified and directed

4

-

-

... More
M & L for of main bearing as per site requirment suitable for 2 to 10 Ton cap crane all as specified and directed

4

-

-

... More
M&L for breake oil suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation or directed . Make : Servo/HP/Castrol

60

-

-

... More
M&L for grease suitable for flameproof EOT crane up to 5 Ton cap as per manufacture recommendation or directed . Make : Servo/HP/Castrol

50

-

-

... More
S & F Thruster for flame proof EOT crane cap upto 5 Ton complete with all accessories all as specified and directed

1

-

-

... More
Disconnecting, dismentling and taking down carefully single pointed air termination alumn rod incl GI pipe any size incl nuts & bolts and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse complete all as specified and directed .

95

-

-

... More
Disconnecting, dismentling and taking down carefully aluminium strip any size upto 32 x 6 mm complete with saddles GI tubing insulators ad seggregating U/S or serviceable parts incl removing from site or setting aside for reuse complete all as specified and directed .

700

-

-

... More
Disconnecting, dismentling and taking down carefully GI strip of any size up to 32 x 6 mm and seggregating U/S or serviceable parts incl removing from site or setting aside for reuse complete all as specified and directed

300

-

-

... More
Supply and fix single pointed air termination alum rod 12 mm dia 300 mm long incl insulator, nuts & bolts for fixing air termination rod to pole pipe all as required at site complete all as specified and directed .

95

-

-

... More
Supply and fix aluminium strip 25 x 3.15 mm complete incl providing nuts, bolts & saddle/Insulators made out of porcelain or fibre for roof conductor/down conductor incl welding or brazing /nut bolts for joints all as required at site or directed

700

-

-

... More
Supply and fix GI strip 32 x 6 mm, buried in ground upto 50 cm depth or fixed to wall with nuts, bolts & saddles/insulators etc for loop earthing incl welding / nut bolts for joints all as required at site or directed . (Note ; earth work will not be paid seperately)

300

-

-

... More
Dismentling and taking down old unserviceable earthing any type incl removing from site complete all as specified and directed .

25

-

-

... More
Material and labour earthing with copper earth plate electrode of size 600 mm x600 mm x3.15 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected with 25 x 4 mm copper strip as earth lead electrode by means of nuts, bolts and washers, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of gem all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, copper earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).

25

-

-

... More
M & L GI Pipe medium grade 20 mm bore for for fixing of ATR complete.

137

-

-

... More
M & L Test point terminal block made of gun metal or phosphorus bronze size incliding 3 Nos 8 mm dia 25 mm long hex. Head screw all as specified and directed

25

-

-

... More
M & L for pre cast cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate for earth pits as mass concrete complete all as specified and directed .

1

-

-

... More
Excavation in trenches in any type of soil n exc 1.5 m in width and n. exc 1.5 m in depth and getting out all as required for laying of cables,foundation filling of poles or stays and for rerouting of cables.

55

-

-

... More
Returning filling, in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as required.

36

-

-

... More
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point.

19

-

-

... More
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm, thick after laying, stretching and testing the cable complete all as specified and directed

18

-

-

... More
M&L for Sub class ‘B’ bricks old size. laid dry flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed .

1.6

-

-

... More
Relaying of old bricks obtained form srl item No 37 flat over the cable abutting each other, length of cable equal to width of brick all as required complete all as specified and directed .

0.56

-

-

... More
Disconnecting electrically and taking out carefully unserviceable cable up to 400 Sqmm from trenches and relaying same after repairs in same or other indicated location after testing complete making connection with proper thimbles all as directed .( Note: Earth work, sand, bricks will be measured and paid separately)

110

-

-

... More
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed 16 sq. mm nominal cross section 2 core in service connections with proper thimbles all as required and directed.

80

-

-

... More
Supply and laying in trenches or fixing to wall/pole or passing through pipe PVC insulated heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 185 Sqmm 3.5 core and making connection with proper thimbles complete all as specified and directed

50

-

-

... More
All as per srl item No 41 but cable of size 95 Sqmm 3.5 core complete all as specified and directed .

70

-

-

... More
M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape ors size as indicated or directed and inclusive of oneprimer coat, one under coat and one finishing coat of alumn paint complete all as specified and directed .

0.5

-

-

... More
Disconnecting electrically, dismantling from foundation with due care and setting aside LT fedder pillar box any type any size with all accessories complete all as specified and directed .

1

-

-

... More
Supply and installation, connecting eclectically & commissioning in replacement of LT feeder pillar box outdoor type of size 0.90 x 0.60 x 0.50 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6mm, 1.5 mtr long, 1.0 mtr above ground level and 0.50 mtr embedded in PCC blocks of size 0.30x0.30x0.50 mtr- 04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 200 amps rated copper bus bar suitable for 3 phase 4 wire supply system duly drilled holes and making all cable connection with proper thimbles mounted on epoxy based post insulators and one MCCB 200 Amps 4 pole 415 Volt, 35 KA complete all as required at site

1

-

-

... More
M&L for GI tubing light grade 50mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clamps for fixing pipe, nuts, bolts washers shall be measured separately )

10

-

-

... More
All as per srl item No 46 above but 40mm bore complete all as specified and directed

10

-

-

... More
All as per srl item No 46 above but 80mm bore v

5

-

-

... More
M&L for reinforced cement concrete ( 1:2:4) type B1 using 20mm graded stone aggregate for making of cable duct cover with handle as directed

0.5

-

-

... More
S&F in replacement of MCCB 250 Amps,36KA, thermal setting adustable 415 volts 50Hz complete with electric connection complete all as specified and directed

1

-

-

... More
All as per item No 50 but MCCB 100 Amps 25 KA complete all as specified and directed .

1

-

-

... More
All as per item No 50 but MCCB 160 Amps 36 KA complete all as specified and directed .

1

-

-

... More
Scraping of old paint from the HT/LT bus bar fixed along PCC plinth without removing and preparation of surfaces for repainting externally. Repainting the HT bus bar complete externally by applying one coat of synthetic enamel paint incl fencing jali of approved colour and also repainting the plinth as per directed

5

-

-

... More
Scraping of old paint from the cable junction box of size not more than 250X150X75 mm fixed along the wall/pole without removing and preparation of surfaces for repainting externally. Repainting the cable junction box complete externally by applying one coat of synthetic enamel paint of approved colour all as required at site or directed.

6

-

-

... More
Scraping of old paint from the cable junction box of size not more than 900X600X500 mm fixed along the PCC plinth without removing and preparation of surfaces for repainting externally. Repainting the cable junction box complete externally by applying one coat of synthetic enamell paint incl fencing jali and also repainting the plinth of approved colour as per directed.

10

-

-

... More
Supply, install, Commisoning and LT distribution control panel board, outdoor type, mounted on rigid angle iron frame, having independent compartment for bus bar, incoming feeder and each out going feeder, dust and vermin proof, factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 400 Amps rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supproted on epoxy insulators - 01 Set, common earth basbar of GI stip 32 x 6 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottomm for each out going and in coming cables and coplete panel board painted with powder coating in siemens grey colour and fabricated with double door system lockable arrangements all as spproved and comprising as under :-

3

-

-

... More
(a) MCCB 4 Pole, current rating 400 Amp, thermal setting adjustable 70%-100% breaking capacity 50 kA at 415V, 50 Hz complete all as specified and directed

-

-

-

... More
(b) MCCB 4 Pole, current rating 250 Amp, thermal setting adjustable 70%-100% breaking capacity 35 kA at 415V, 50 Hz complete all as specified and directed

-

-

-

... More
(c) MCCB 4 pole, current rating 63 Amp 50 C/S 10 KA 'C' sereis complete all as specified and directed

-

-

-

... More
(d) Digital type Amperemeter 0 - 200 Amps with CTs & selector switch - 1 Set complete all as specified and directed .

-

-

-

... More
(e) Digital type Voltmeter 0 - 500 Volts with selector switch - 1 Set complete all as specified and directed .

-

-

-

... More
(f) Indicator Lamp - R - Y - B (Set of three) complete all as specified and directed .

-

-

-

... More
Supply and fix in repair capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity complete all as specified and directed.

1

-

-

... More
Supply and fix in repair capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity complete all as specified and directed.

1

-

-

... More
Taking down carefully aluminum/copper point wiring (light fan socket or power) complete with fitting such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCB'S,Main switch from control board and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.

853

-

-

... More
Point wiring for one light point/fan point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FR with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed by Engr in Charge & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified

440

-

-

... More
All as per srl item No 60 above but upto ceiling height and on surface at ceiling complete all as specified and directed .

35

-

-

... More
All as per srl item No 60 above but in existing conduit complete all as specified and directed .

20

-

-

... More
All as per srl item No 60 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit complete all as specified and directed .

75

-

-

... More
All as per srl item No 60 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in existing conduit complete all as specified and directed .

35

-

-

... More
All as per srl item No 60 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed .

50

-

-

... More
All as per srl item No 60 above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit complete all as specified and directed .

70

-

-

... More
All as per srl item No 60 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed

85

-

-

... More
All as per srl item No 60 above but for one 5A socket outlet on the same board controlled by one switch in existing conduit complete all as specified and directed

35

-

-

... More
All as per srl item No 60 above but for one light point controlled by 2 nos two way switches complete all as specified and directed .

5

-

-

... More
All as per srl item No 60 above but for one light point controlled by 2 nos two way switches in existing conduit complete all as specified and directed .

3

-

-

... More
M&L for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FR) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in & including concealed PVC conduit medium grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed

250

-

-

... More
All as per srl item No 71 above but in existing concealed conduit complete all as specified and directed .

240

-

-

... More
All as per srl item No-71above but for cable of size 6 sqmm in & including concealed PVC conduit complete all as specified and directed .

110

-

-

... More
All as per srl item No-71 above but for cable of size 6 sqmm in existing concealed conduit with earth wire 4 sqmm complete all as specified and directed .

70

-

-

... More
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified and directed

700

-

-

... More
Switch piano flush button single pole one way 15/16 amps 230 Volts complete all as specified and directed

162

-

-

... More
M&L for switch piano flush button single pole two way 5 amps 240 volts complete all as specified and directed

37

-

-

... More
M&L for bell push flush button single pole one way 5 amps 240 volts complete all as specified and directed

65

-

-

... More
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed

250

-

-

... More
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed

210

-

-

... More
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed

325

-

-

... More
M&L for bell electric heahy duty Ding Dong type 230 volts single pole complete and all as specified

55

-

-

... More
S & F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed

145

-

-

... More
S&F in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed

130

-

-

... More
S&F Rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed

120

-

-

... More
S&F bulk head light fitting 1 x 18 watt suitable for compact fluorescent lamp complete with lamp including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed

37

-

-

... More
Cutting chases, pinning in. making good to facings where required and pointing in S & F in replacement of Slim recessed mounted LED panel light 15 watt square shape with dia cast housing finished in white powder coated complete all as specified and directed

4

-

-

... More
S & F in replacement of Slim surface mounted LED panel light 12 watt square shape with dia cast housing finished in white powder coated complete all as specified and directed

6

-

-

... More
S&F fluorescent tube light fitting mounting box type 1x40 watts complete with electronic ballast, spring loaded bipin holders, capacitor, connector block, decorative plastic end cover all accessories prewired with suitable size cable conf to Cat Pt No IGP 1414 EB of Crompton Greaves or equivalent of make Havells /Philips including 4' , 1x36/40 watts tube rod including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required complete all as specified and directed

55

-

-

... More
All as per item No 89 but cat part No tube fitting 1 x 36 Watt BJBN1314 EB complete all as specified and directed

30

-

-

... More
S& F LED tube rod 1x16 Watt energy efficient of T8, 4 feet long with same form factor & appearance as flourescent tube light complete all as specified and directed

100

-

-

... More
S&F CRCA body, powder coated white regal batten type luminaire fitting pre-wired for T8 LED 1x18 Watt tube light cat part No DMLN1LT8-16 of CG complete all as specified and directed

95

-

-

... More
S & F in replacement of Wall mounted fitting decorative luminare 2 x 15W CFL curvy with deorative glass with 2 x 15 W CFL curvy thread type and connecting electrically to ceiling rose using PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 0.50 Sqmm complete all as specified and directed .

10

-

-

... More
S&F sleek LED mirror light with diffuser 2ft x 10 Watt complete all as specified complete all as specified and directed .

9

-

-

... More
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No 607913 of Legrand or equivalent of make Havells complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed

1

-

-

... More
All as per item No 95 above but for 8 way complete all as specified and directed

1

-

-

... More
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link conf to Cat Pt No 607710 of Legrand or equivalent of make Havells fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed

7

-

-

... More
All as per item No 97 but for 8 way complete all as specified and directed

14

-

-

... More
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps earthing complete all as specified and directed

6

-

-

... More
Supply and fix bus bar chambers 300 mm long factory febricated iron clad with 4 Nos 200 amp rated copper strips complete fixed flush wall and making good the disturbed wall surfaces all as a required at site or directed.

2

-

-

... More
All as per item No 100 above but with 2 Nos 100 amp rated copper strips complete all as specified and directed

2

-

-

... More
S&F in replacement of meter fixing box made out of thermoplastic grey colour with transparent cover, cable entry cover, hinged flap, protection cover including cable entry integrated elastic membrance suitable to accommodated one single phase KWH meter including dismentling of old existing meter & meter box, breaking of seal of meter and fixing meter box to flush wall and making connection with proper thimbles, good disturbed surfaces ,refixing seals and wires of the fixing the existing meter in meter box complete all as specified and directed

2

-

-

... More
All as per srl item 102 No but two single phase KWH electric meter complete all as specified and directed .

15

-

-

... More
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed

100

-

-

... More
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 KA using thimbles of required size complete all as specified and directed

35

-

-

... More
M&L for Earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by Engineer-in-charge and testing on completion.

8

-

-

... More
Repair, maint and making the continuity of supply after rectifying the defects of the electrical items such as switches, replacement of fuse wires, distribution boards, MCB (light/power), lamp holders (bracket/ pandents/ batten), bell/buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc. including providioning of small pieces of electrical wire of size 1.5 sqmm to 10 sqmm single core and length not exceding 0.50 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed by Engineer-in-Charge (Note :- (i) any accessories found unserviceable that shall be replaced & paid under respective items of this Sch complete all as specified and directed .

1700

-

-

... More
Supply & fix Rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed

50

-

-

... More
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size .75 Sqmm complete all as specified and directed

20

-

-

... More
All as per item No 110 but size 1.5 Sqmm complete all as specified and directed .

100

-

-

... More
All as per item No 110 but size 2.5 Sqmm complete all as specified and directed .

100

-

-

... More
All as per item No 110 but size 4 Sqmm complete all as specified and directed .

65

-

-

... More
All as per item No 119 but size 6 Sqmm.

40

-

-

... More
Supply & fix in replacement cord flexible PVC insulated and over all sheathed, 3 core, flexible copper conductor of size 0.75 sqmm, cut to size all as required at site

90

-

-

... More
All as per item No-115 but size 1.5 sqmm.

120

-

-

... More
M&L for switch modular type single pole one way 1 module 6 amps 240 volts.

15

-

-

... More
Switch modular type one way 1 module 16 amps 230 Volts

9

-

-

... More
M&L for bell push modular type 1 module one way 6 amps 240 volts

2

-

-

... More
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts

9

-

-

... More
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts

8

-

-

... More
M&L for buzzer 230 volts single pole complete and all as specified

20

-

-

... More
M&L for round surface plate up to 6" complete and all as specified

90

-

-

... More
Supply & fix in replacement Choke eletronic 36/40 watts 230 volts with white engineering sleeker white engineering plastic housing

200

-

-

... More
All as per item No 124 above but 28 Watt.

165

-

-

... More
Supply & fix in replacement Heavy duty vaccum pressure impergenated electronic ballast for CFL 9/10/11 watts

40

-

-

... More
All as per item No 126 above but 18/20/22 watts .

20

-

-

... More
S&F Tube rod 4', 1x 36/40 Watt 240 Volts 5 star all as directed by Engr-in-Charge

150

-

-

... More
All as per item No 128 above but 2'x14 to 24 watts .

40

-

-

... More
All as per item No 128 above but 4'x28 watts T5.

120

-

-

... More
Fixing only tube rod 4' x 28/36/40 watt any type (tube rod 4' x 28/36/40 Watt will be issued free for fixing under Sch 'B' only.)

150

-

-

... More
Supply & fix in replacement compact fluorescent lamp 9 watts 230 volts 6500 K, 2 pin cross/straight type

80

-

-

... More
All as per item No 132 above but 11 watts.

120

-

-

... More
All as per item No 132 above but 18/22 watts.

15

-

-

... More
All as per item No 132 above but 36 watts 4 pin .

55

-

-

... More
S&F in replacement compact fluorescent lamp 15 watts curvy 230 volts 6500 K, thread type

15

-

-

... More
S&F in replacement compact fluorescent lamp 10 watts, 230 volts for bulk head fitting

45

-

-

... More
S&F in replacement lamp holder suitable for CFL lamp any type upto 9 to 36 watts any type as per site requirement

30

-

-

... More
S&F in replacement spring loaded rotary type bipin holder suitable for tube light fittings 4' x 28/36/40 watt all as required at site or directed

45

-

-

... More
S&F in replacement starter AC 240 Volts suitable for fluorescent tube light fittings 36/40 watt

40

-

-

... More
Disconnecting & taking down existing ceiling/exhaust fan any type and capacity with due care and handing over to user for repairing from MES and refixing after getting rapaired from MES workshop by users complete with all accessories.

65

-

-

... More
Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing and greasing complete. Re-assembling and refixing to the same/other location after replacing rubber reel, fixing bolts and nuts with lock pins, connectors for complete fan including writing MES No all as required and directed by Engineer-in Charge. Testing complete after servicing and fixing for smooth and noise free operation.

30

-

-

... More
S&F in replacement capacitor 2.5 mfd 440 volts for fans

100

-

-

... More
S&F LED inverted lamp of 09 watts

150

-

-

... More
S&F LED inverted lamp of 12 watts

15

-

-

... More
b) MCCB 125 Amps ,4P, 50 Hz, 415 V with minimum rupturing capacity 16 KA (Thermal magnetic release) Ics=100%Icu and adjustable overload setting 80% to100% - 01 Nos (outgoing).

8

-

-

... More
All as per item No- 146 but for 2.0 KW .

8

-

-

... More
S&F in replacement thermostat switch 0 to 100°C , 240 volts suitable for water heater storage

14

-

-

... More
S&F in replacement syphon assy any type for water heater storeage type upto 50 ltr cap complete all as specified.

4

-

-

... More
S&F in replacement inner tank any cap for water heater storeage type upto 50 ltr cap complete all as specified.

1

-

-

... More
S&F in replacement metal plug 20 Amps 240 volts with 2 pin and earth plug

4

-

-

... More
All as per item No 151 but metal socket 20 Amps .

2

-

-

... More
S&F in replacement plug top 3 pin 16 amps AC 240 Volts

10

-

-

... More
S&F in replacement plug top 3 pin 6 amps AC 240 Volts

10

-

-

... More
S&F in replacement plastic laminated top sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box

20

-

-

... More
All as per item No-155 but of size 8"x5" .

20

-

-

... More
All as per item No-155 but of size 11"x9".

6

-

-

... More
All as per item No-155 but of size 13"x11" .

6

-

-

... More
Fixing only metal flush sunken box of any size up to 13" x 11" including desmentling old box and fixing new with PCC work including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified. (sunken box steel any size will be issued free for fixing under Sch 'B' only.)

40

-

-

... More
S& F LED tube rod 1x16/20 Watt energy efficient of T8, 4 feet long with same form factor & appearance as flourescent tube light

55

-

-

... More
S&F CRCA body, powder coated white regal batten type luminaire fitting pre-wired for T8 LED 1x18/20 Watt tube light

20

-

-

... More
S & F in replacement of Slim recessed mounted LED panel light 15 watt square shape with dia cast housing finished in white powder coated

8

-

-

... More
S & F in replacement of Wall mounted fitting decorative luminare 15/18 Watt CFL curvy with deorative glass with CFL curvy thread type and connecting electrically to ceiling rose using PVC insulated and overall sheathed 3 core flexible copper conductor cable of size 0.50 Sqmm as per sample given by Engr-in-harge.

9

-

-

... More
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No 607913 of Legrand or equivalent of make Havells complete with one MCCB 3 pole 415 Volts 63 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge.

1

-

-

... More
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link conf to Cat Pt No 607720 of Legrand or equivalent of make Havells fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .

2

-

-

... More
All as per item No 165 but for 8 way

4

-

-

... More
Supply and fix bus bar chambers 300 mm long iron clad with 4 Nos 200 amp rated copper strips complete fixed flush in wall and making good the disturbed wall surfaces all as a required at site or directed.

1

-

-

... More
All as per item No 167 but with 2 Nos 100 amp.

1

-

-

... More
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size

100

-

-

... More
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size

40

-

-

... More
All as per item No 170 above but of size 63 Amps.

4

-

-

... More
Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete and all as specified. Note :- 1. Repairs will be measured and paid separately under respective items. 2. Fans will be repaired at MES workshop Unchibassi.

388

-

-

... More
Winding of AC ceiling fan motor 1200 mm sweep any make/size with super enamelled copper winding wire any gauge from 0.315mm to 0.193mm including cutting of old burnt winding. Sleeve work varnishing with `B' class insulation varnish, connection with flexible wire of appropriate size two core copper wire upto connector block qty of copper winding wire not less than 350 grms and not more than 500 grms per fan motor complete and all as specified.

296

-

-

... More
All as per item No 173 above but 1400mm sweep of copper winding in each motor wire not less than 400 gms and not more than 650 gms complete and all as specified.

260

-

-

... More
Dismentling and taking down old unserviceable earthing any type incl removing from site.

40

-

-

... More
All as per srl item No 175 above but 3.15 mfd.

310

-

-

... More
Point wiring for one light point/fan point controlled by one switch with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including concealed non metalic In stove enamelled steel conduit medium grade with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed by Engr in Charge & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified

10

-

-

... More
All as per srl item No 177 here in above but for one 3 pin 15 Amps socket outlet independent with 4 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit.

10

-

-

... More
S&F Flame proof distribution board enclosure 8 way made out of galvanised steel sheet class EX II housed with flame proof MCBs of following capacities :-

2

-

-

... More
(a) MCB SPN 10 KA breakng capacity 32 Amps - 01 No

-

-

-

... More
(b) MCB SP 10 KA breaking capacity 6 Amps-06 Nos

-

-

-

... More
S&F Flame proof distribution board enclosure 4 way made out of galvanised steel sheet class EX II housed with flame proof MCBs of following capacities :-

2

-

-

... More
(a) MCB SPN 10 KA breakng capacity 20 Amps - 01 No

-

-

-

... More
(b) MCB SP 10 KA breaking capacity 6 Amps-04 Nos

-

-

-

... More
Note :- The enclosure and MCBs should be flameproof with explosion protection suitable for Zone - II. The rate quoted by the tender shall be deemed inc of all accessories required for the connections

-

-

-

... More
S&F in replacement of flame proof compact fluorescent tube light fitting 1x36 Watt including chocke,capacitor & starter will be provided in control gear box and 36 Watt tube rod inclunding all accessories prewired with heat resistant glass cover, polyester resin enclosure and centrally locking system suitable for class I,Zone II E Ex II C including proper fixing arrangement on elevation on angle iron frame with clamps, nut, bolts & washers of suitable size as recommended by manufacturer and directed by Engr-in-Charge inluding electric connection

5

-

-

... More
All as per item No 186 above but of 2 x36 Watt complete all as specified and directed.

6

-

-

... More
Repairs to ceiling fan complete including alignment grinding to shaft, remetalling & finishing all as required and reassembling after repairs and replacement of un serviceable items under respective items all as required at site and directed.

121

-

-

... More
Ceiling fan shaft of standard size including taking out old shaft, complete and all as specified.

90

-

-

... More
Strip opening of exhaust fan/air circulator/table fan/Pedestal fan any size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete and all as specified.

12

-

-

... More
Rewinding of exhaust fan/ air circulator fan/ table fan/pedestal fan motor any size, from 225 to 450 mm sweep with supper enamelled copper wire of any size ranging from 0.500mm to 0.285 mm including necessary cutting of old burnt winding wire, cleaning of slots and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete and all as specified.

14

-

-

... More
Replacement of ball bearing any No suitable for ceiling fan upto 1400mm sweep complete and all as specified

180

-

-

... More
Replacement of ball bearing for exhaust fan/pedestal fan/air circulator/table fan upto 450mm sweep complete and all as specified

10

-

-

... More
Cleaning thoroughly ceiling fans 48"/56" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified & directed

350

-

-

... More
Replacement of fan blade set heavy duty suitable for pedestal/air circulator fan 400/500 mm sweep, complete (as per sample) and all as directed

8

-

-

... More
Supply and fixing fan blade set 1200/1400mm sweep complete (as per sample) and all as directed

100

-

-

... More
Replacement of down rod 90 cm long for ceiling fan 1200/1400mm sweep including clamps, reel, lock nuts, split pin etc complete and all as directed

70

-

-

... More
Disconneting & taking down ceiling fan up to 1400 mm sweep / exhaust fan up to 450mm sweep for servicing, strip opening of fan including servicing and greasing complete at site. Re-assembling and refixing to the same/other location after replacing rubber reel, fixing clamp, bolts and nuts with lock pins, connectors for complete fan including writing MES No all as required and directed by Engineer-in Charge. Testing complete after servicing and fixing for smooth and noise free operation complete all as specified and directed .

311

-

-

... More
Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site as directed

102

-

-

... More
Sch of Credit = 127461.00

-

-

-

... More
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.