Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date13 Sep 2021
Closing Date8 Oct 2021
Tender Amount₹ 32,68,692 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply,laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables(heavy duty) 1100 Volts grade with stranded aluminium conductor including suitable lugs for connection of 25 sqmm X 4 Core size cable complete all as specified and directed.

200

-

-

... More
Excavation in trenches in soil n.exe 1.5 mtr wide and 1.5 mtr deep for laying of cables including getting out complete all as specefied and directed.

209.6

-

-

... More
Excavation in trenches soft/loose soil n.exe 1.5 mtr wide and exc 1.5 mtr deep up to 3.0 mtr for laying of cables/poles including taking down complete all as specefied and directed.

0.86

-

-

... More
Returning filling of layers including spreading, leveling complete all as specefied and directed.

150.05

-

-

... More
Removing surplus spoil to a distance not exceeding 50 m and depositing where it is directed complete all as specefied and directed.

60.55

-

-

... More
Supply and filling Dry clean sand for sand cushioning of underground cable complete all as specified and as directed. Note:-Sand shall be measured after punning down.

18

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover , class LV, Type 1, flat of size 250 mm x 150 mm x 40 mm for cable protection, confirming to IS : 5820-1970 and having minimum average load breaking strength 200 Kg/Sqcm complete all as specified and as directed.

1456

-

-

... More
M & L for precast concrete cable covers LV type 2 flat, size 250mm x 150 mm x 40 mm laid dry in trenches for cable protection complete all as specified and directed

3120

-

-

... More
Supply and fixing Tubes, 'light grade' galvanised, 40 mm dia with all fitting and fixed complete to walls and ceilings or laid in floors or buried in ground for passing through of cable or for strip protection of air termination making good the disturbed surface matching with existing all as specified and directed.

12

-

-

... More
M & L for Earthing complete with galvanized steel earth plate, electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing strip covered with 20mm bore GI pipe light grade by means of bolts, nuts, check nuts and washers of galvanised iron or steel, connected to earthing test point, earth plate electrode surrounded by mixer of common salt and charcoal dust, including 20 mm dia GI watering pipe 'medium grade', funnel with wire mesh, earthing chamber with cement concrete (1:3:6) type C-1, RCC chamber cover 80 mm thick (1:2:4) type B-1, excavating & earth work all as shown in electrical plate No. 3 of SSR (Part-I) and testing on completion complete all as specified and directed.

10

-

-

... More
M & L for Earthing complete with galvanised steel earth plate electrode 60X60cmX6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.

3

-

-

... More
M & L for Earthing complete with galvanised steel earth plate lectrode 60X60cmX3.15mm thick, buried directly in ground (earth pit notless than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to earth strip using copper strip 20x 3 mm as earthing strip by means of bolts, nuts, check nuts and washers of copper or brass all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion

12

-

-

... More
M & L for Gl pipe light grade 40mm dia including all fitting fixed on walls/ buried in ground for strip protection of air termination/ complete all as specified and as directed.

24

-

-

... More
M& L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and as directed.

21

-

-

... More
S&F Copper strip 20 x 3.15mm with saddles and fixing screws etc.for roof conductors and down conductors above ground complete all as specified and as directed.

280

-

-

... More
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 20x3 mm copper strip complete all as specified and as directed.

150

-

-

... More
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.

12

-

-

... More
S&F Surge protection device lightning protection class B three phase comprises of following mentioned below complete all as specified and as directed. Notes:- (i) Should be installed at the main entrance AC Distribution Level. (ii) Maximum Operating Volts : 255V/50 Hz AC per phase and Normal 230V, AC. (iii) Lightning/Surge Protection Rating: Line – Neutral = 50KA; Neutral – Ground = 100KA tested @ 10/350us test pulse. (iv) Protection Mode : Line – Neutral & Neutral-Ground (v) Protection Level at Iimp must be : 4 KV. (vi) Response Time : 50 nano seconds (vii) Backup fuse Range : 160 A to 250 A as required. (viii) Operating Temp range : -20° to + 80°C. (ix) Insulation Resistance: 10¹° Ω (x) Protection Category/Tested acc to E DIN VDE 0675-6-1/89-A1 and IEC 61643-1.

1

-

-

... More
S&F Surge protection device lightning protection class C three phase comprises of following mentioned below complete all as specified and as directed. Notes:- (i) Surge Handling Capacity - 50KA per Phase. (ii) Lightning (Surge) Protector should have Let Through Voltage (Protection Level) as given below: must be 900 V. (iii) Nominal discharge current-20 kA; Short-circuit current rating-100 kA. (iv) Must have provision to protect surges/spike of Line - Neutral, Line - Ground, Line - Line and Neutral - Ground. (v) Lightning (Surge) Protector must be designed to withstand multiple strikes. (vi) Response Time 1ns. (vii) Lightning (Surge) Protector must be UL, CE Compliant to IEC 61643-1 or other standard recognized. (viii) Enclosure of Surge Suppressor must be IP20. (ix) Operating Temperature: -20ºC to + 60ºC (x) Circuit Diagnostics: LED indicators for each phase

1

-

-

... More
S&F High/Low voltage disconnector comprises of following mentioned below complete all as specified and as directed. Notes:- (i) Must be designed to protect the communication complex and the equipment from high/low voltages. (ii) High/Low Voltage Disconnector : This device must be designed to allow voltage in between 330V-470V for three phase and 160-265V for single phase only. Any voltage exceeding or below must be disconnect (within 100ms) using suitable UL approved contactors.

1

-

-

... More
S&F Multistage Telephone line protection (10 Lines) comprises of following mentioned below complete all as specified and as directed. Notes:- (a) Tele Line Protector Krone Type TPU-10 pair module at MDF (i) Must be designed to protect from transient and high current/voltage interference to telephone lines (ii) System Configuration : PCB/ Plug version, to be fitted into MDF, Krone MDF with LED indication. (iii) Protection Circuit : Combination of Hybrid GD tube with inbuilt Silicon Avalanche diode with PTC between each line to be provided. (iv) Nominal operating voltage : 110V AC, 75/ V DC (v) Nominal Current : 120 milli amp (vi) Nominal Discharge current Ins (8/20 µs) (Between Tip/ Ring to Earth) : 5 KA (vii) Maximum discharge current ins (8/20 µs) (Between tip/ ring to Earth) : 10 KA (viii) Max surge handling Capacity 20KA (ix) Response Time of Telephone Line Protector must be 1ns (x) Thermal Fuse (PTC) must be of 145mA rating (xi) Indication : LED indication to show the High Voltage Induction on the line (xii) This system must have let through (residual voltage) as given below Test Report must be submitted: aa)1KV/200A test pulse must be 180V ab) 6KV/3KA test pulse should be 250V (xiii) Enclosure must be Plastic IP20

30

-

-

... More
(b)Data Line Surge Protector (RJ 45 Type) (i) Operating Voltage : 5V/60V (ii) Capacitance : 50pF (iii) Surge Current : Greater than 3KA (8x20µs) (iv) Impedance : 0.02Ω (v) Surge rated voltage : Should meet AS 1768-1991 Cat B (vi) Suitable Protector to be provided for UTP and/or STP Cables and all 8 pins must be protected. (vii) Operating Temp : -20ºC to +50degree C (viii) Humidity: 0 to 95%

-

-

-

... More
Supply and fix room split type Air Conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour (2.0 ton) BEE 5 star rated complete all as specified and as directed.

4

-

-

... More
Supply and fixi voltage stablizer for automatic operation, single phase naturaaly air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +-2.5 % and of capacity 4 KVA complete all as specified and directed.

4

-

-

... More
Supply & fixing of water heater storage type, BEE 5 star rated, electric of capacity 25 ltrs opearting on 240 volt AC, 50 Hz with all the safety features such as safety valve , auto cut off, indication lamp . Including grouting and 04 ANCHOR bolts for fixing the geyser including plug top 15 Amp and PVC connection pipe for hot and cold water complete all as specified & directed.

56

-

-

... More
M&L for sub main wiring with two single core 4 Sqmm PVC insulated and unsheathed FR ,stranded copper conductor cable drawn in and including PVC rigid non metallic concealed conduit 25 mm dia incl 2.5 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.

896

-

-

... More
S & F sheet metal enclosure with socket, plug top and single pole MCB (SP) of 20 amp capacity all as per directed for 25 ltr cap geyser.

56

-

-

... More
S&F MCB, single pole 240 volts 16/20 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed.

56

-

-

... More
S &F Bib tap chromium plated with crutch or buttterfly handle ,screwed down , screwed for iron pipe of 15 mm bore dia.

56

-

-

... More
M&L stop valve, cast copper alloy ,high pressure, with crutch or butterfly handle screwed both ends for iron pipe and fixed complete of 15 mm dia bores, ISI marked.

56

-

-

... More
M&L pipe galvanized iron medium grade 15 MM Bore complete with all fittings and fixed complete to walls ,and ceiling or laid in floors, jointed tested and commissioned complete all as specified and directed.

130

-

-

... More
Supplying & fixing of Aesthetically Designed SMD LED Street light luminaires of 70 to 72 watts System wattage for energy saving having IP-66 degree of protection ,With minimum system efficiency as 85 % ,made of Pressure die cast aluminum housing powder coated in graphite grey and heat resistant thoughned glass with excellent thermal management including PVC cable connector. LED's should have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light. Fitting should have operating voltage range of 120 - 270 VAC , THD 10% , P.F .95 .The fitting should have in built surge protector of 5 KV and CRI 70 with CCT 5700 K complete all as specified and directed

16

-

-

... More
Supply and fixing GI bracket 1.2 mtr long 40 MM dia complete with MS clamp bolts and nuts for fixing of bracket complete all as specified and directed.

16

-

-

... More
Supply and laying XLPE 1100 volts grade heavy duty with PVC insulated, armoured cable, 4 core 10 sqmm in service supply connection passing through trenches, walls, road crossings and poles complete all as specified and directed.

600

-

-

... More
Sand bedding for coushing of cables complete all as specefied and directed.

21.87

-

-

... More
Supply and fix PVC insulated round/flat copper cable of size 3 core 1.5 sq mm for connection of LED lights from FRP junction box to street light fittings complete all as specified and directed.

128

-

-

... More
Supply & fix Prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 including painting complete all as specified and directed.

16

-

-

... More
Supply and fix junction box made out of PVC 30cmx20cmx10.5cm complete including aluminium busher of suitable size three phase with insulators and MCB SP of 6 Amps complete all as specified and directed.

16

-

-

... More
Suppy and fixRigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.

96

-

-

... More
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation of pole all as specified and directed.

9.5

-

-

... More
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate for copping around the pole strut above ground level, foundation of stay etc. including neccassory form work and finishing the surface fair and even without using extra cement all as directed and specified

1.46

-

-

... More
S&F GI pipe light grade 40 mm passing through cables, walls , across the roads with proper clamps, nut & bolts including taking down complete all as specefied and directed.

32

-

-

... More
Supply and fixing of automatic street light control switch single phase 5-8 KW 40 Amps using infrared sensor based nature switch for automatic switching of street lights. Nature switch operation should be based on Natural light lux level. The sensor along with suitable power contactors and incoming out going MCBs should be enclosed pole/wall mounted thermo plastic polycarbonate enclosure conforming to IP 66 protection class 2. Make: Nature switch: Kakatiya Energy systems/BAJAJ/Healer Contactors: BCH/L&T/Schneider MCBs: Hager/Schneider/L&T Enclosure: Hensel/GE or equivalent Circuit wiring: Polycab/ Finolex or equivalent

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.