Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,44,850Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680706_1Tender No
84465Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(d) Server:
The redundant server must be of high industrial quality, designed for continuous, reliable operation. It should be capable of handling all key SCADA functions, including data acquisition and storage. The minimum server specifications include:
1. CPU: Quad Core, 3.90 GHz
2. Cache: 10 MB
3. RAM: 16 GB
4. Storage: 4 x 1 TB SATA (Serial Advanced Technology Attachment) hard drives
-
-
-
(e) Data Gateway
(f) SCADA software which can be operated, programmed and modified by agencies other than developer. The SCADA software should have a modular structure, supporting client/server functionality and scalable from small to large applications. SCADA computers must have firewalls, ensuring cybersecurity for RTUs and microprocessor-based controllers.
(g) PLC/ Microprocessor Controllers with indoor/ outdoor applications for water sensing display, pump operation with RTU/ without RTU or Microprocessor controller and microprocessor transmitter
(h) Suitable communication system including payment of bills to telecom service provider.
-
-
-
(i) Motorised butterfly valves (j) Pressure transmitters
(k) Ultrasonic sensors
(l) Flow meters and switches (m) Air Release solenoid valves
Notes:
(i) Design of Communication System shall be done by the bidder. Cloud based server/ data storage/ communication shall not be used and only local server based system shall be designed.
(ii)The cost of each item shall also be attached to arrive at pricing in case of some addition/ reduction at site.
(iii) Operating system, system software and programming shall not be intellectual property of any agency.
(iv) The memory in the hard disk shall be suitable for six months data. The backup storage device/ devices shall be provided for archiving of data more than six months old.
(v) In case of addition of installations, the system shall be capable of integrating the same.
(vi) The responsibility of the agency is restricted to intimate mechanical and electrical failures such as failure of pumps, leakages etc. Such repairs shall be carried out by MES
(vii) Operation and maintenance charges to be paid separately.
(viii) The SCADA system should have provision of both manual and automatic operation of installations.
-
-
-
Operate SCADA system during defect liability period for two years without manning (Contractor to provide month wise breakdown details of the same). (No manning or deployment of manpower required).
-
-
-
First Year of DLP
1
-
-
Second Year of DLP
1
-
-
Operation and comprehensive" maintenance of SCADA system including cost of upgradation, cost of spares for 8 years post defect liability period, operation including year payment of bills by telecom service provider (Contractor to provide month-wise breakdown details of the same). (Not to exceed 4% of item No. 1) Note: Cumulative payment shall be made (after expiry of DLP) or not exceeding basis as per following schedule:-
-
-
-
1st Year After DLP
1
-
-
2nd Year after DLP
1
-
-
3rd Year After DLP
1
-
-
4th Year After DLP
1
-
-
5th Year After DLP
1
-
-
6th Year After DLP
1
-
-
7th Year After DLP
1
-
-
8th Year After DLP
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%