Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date5 Sep 2024
Closing Date26 Sep 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L rough cast over rendering of 10 mm thick on fair face of brick or concrete surface as in CM 1:4 all as specified and directed by Engr-In-Charge.(The rough cast mixture shall consist of crushed stone or fine gravel aggregate, coarse sand & cement in the ratio of 1:1:1 over rendering coat.)

350

-

-

... More
M&L for 5mm thick plaster on ceiling in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engr-In-Charge.

200

-

-

... More
M & L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified & directed by Engr-In-Charge. Note : Payment for providing grooves shall be made separately.

1100

-

-

... More
M & L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.

1650

-

-

... More
Taking down old deteriorated concrete /plaster of old surfaces of facia,parapet,slab edges,projection bottom etc & applying 15mm thick rendering in cement mortar 1:3, finishing surfaces even and smooth without using extra cement including two coat of exterior acrylic emulsion paint with necessary scaffolding,doubing coat complete all as specified and directed. Note:-Work is to executed in buildings of height upto 15 metres and Quoted rate of the item is deemed to included the same.

250

-

-

... More
Demolition/Dismantling of brick work or stone/boulder masonary built in any cement mortor including all quoins,arches,pillars etc complete all as specified & directed by Engr-In-Charge.

12

-

-

... More
M & L for brick work with old size fly ash bricks, straight or covered or plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer in Charge.

12

-

-

... More
M&L for Preparation of newly plastered surfaces of walls etc., and applying two coats of cement base paint complete all as specified & directed by Engr-In-Charge.

880

-

-

... More
M&L for preparation of Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed by Engr-In-Charge.

350

-

-

... More
M&L Preparation of new plastered surfaces of walls & applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified & directed by Engr-In-Charge.

405

-

-

... More
M&L for Preparation of newly plastered surfaces of walls etc., and applying two coats of white wash complete all as specified & directed by Engr-In-Charge.

135

-

-

... More
M&L for Preparation of new plastered surfaces and applying two coats of white wash on ceiling as specified & directed by Engr-In-Charge.

200

-

-

... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying one coat of oil bound distemper after filling of putty in minor cracks present (if any) complete all as specified and directed by Engr-In-Charge.

600

-

-

... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying one coat of Cement base paint complete all as specified and directed by Engr-In-Charge.

2000

-

-

... More
M&L Preparation of old srufaces of wall including brooming down or steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spots and applying two coat of white wash complete all as specified and directed by Engr-In-Charge.

400

-

-

... More
M&L for preparation of old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of distemper oil emultion white/tinted over a wall care putty finished surface complete all as specified.

700

-

-

... More
M&L for complete removal of existing old decorated surfaces of wall by brooming down and scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of acrylic emulsion paint complete all as specified. Note :- Curing of surface will be carried out as per Para 15.15.3 of SSR Part-I

1100

-

-

... More
Dismantling of existing old padding concrete of any thickness of existing water proofing treatment over the RCC slab other than beams, chajjas, staircasse etc by chipping of with proper tools viz chiesel and with applying rerasonable force to avoid any damages to the existing RCC roof slab complete all as specified and directed by engineer in charge.

24

-

-

... More
Dismantling of brick tiles or terracing tiles single layer including mud phuska etc on roof & disposal of retrieved material to a distance n.exc 100m from the starting point complete all as specified and directed.

150

-

-

... More
M&L 40mm thick brick tiles laid on lime concrete and joints grouted flush in cement mortar 1:3 mixed with 5% of crude oil by weight of cement over & including 15 mm thick screed in cement mortar 1:6 complete all as specified and directed .

150

-

-

... More
M & L Raking out joints/ pointing brick work or brick tiles, laid flat in Cement mortar, in floors, surface channels, roofs, etc.complete all as specified and directed by Engr-In-Charge.

20

-

-

... More
M & L for Flush pointing to bricks laid flat or brick tiles in CM 1:3 in pavings in floors, roofs, aprons etc complete all as specified and directed by Engr-In-Charge.

20

-

-

... More
M & L for Roof plaster of mortar 15 mm thick in CM 1:3 after removing old deteriorated plaster complete all as specified and directed by Engr-In-Charge. Note : WPC shall be measured seperately.

600

-

-

... More
M&L for roof padding of 40 mm thick cement concrete 1:2:4 Type B2 (12.50mm aggregate) with WPC including and applying cement slurry @ 3kg/Sqm complete all as specified and directed. Note : WPC shall be measured seperately.

600

-

-

... More
Supply only Integral water proofing compound.

351.06

-

-

... More
M & L for Providing, cement concrete Type B0; 1:2:4,(using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges after demolition of existing deteriorated cement concrete complete all as specified and directed by Engr-In-Charge.

1

-

-

... More
Demolition of unreinforced cement concrete in ground floor, plinth protection, paving not exceeding 15 cm thick (below or above ground level) complete all as specified & directed by Engr-In-Charge.

33.75

-

-

... More
M&L for 75 mm thick cement concrete 1:3:6, type C-2, (using 40mm graded crushed stone aggregate) as in plinth protection/path, finishing surfaces even and fair complete all as specified and directed .

450

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engr-in-charge.

600

-

-

... More
M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,and pointed in white or coloured cement to match & including 15 mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by engr-in-charge.

200

-

-

... More
M&L Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 15mm thick screed bed CM 1:4 for laying finishes,complete all as specified as directed by Engr-in- Charge

120

-

-

... More
S&F Glazed ceramic coloured tiles with highlighter in vertical surface 350x250x7 mm / 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15 mm thick rendering in CM 1:4 on other than fair face of brick work. Note : Highlighter shall be provided as directed by Engr-in-Charge.

80

-

-

... More
M&L for Endura floor / parking Vitrified tiles 10 mm thick square /rectangular polished area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc .set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM (1:6) and poined in white or colour cement to match complete all as specified & directed by Engr-In-Charge.

200

-

-

... More
Dismantling of Stone slabs of any description or thickness in floors, plateform, apron etc laid bedded and pointed in any mortar including removing rubbish material from building and thrown in low lying empty area at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge.

20.9

-

-

... More
M&L 20 to 25mm thick Machine cut kota stone slab as in flooring over and including 20mm thick screed bed in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.

170

-

-

... More
M&L Kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar over and including 15 mm thick rendering 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete

17

-

-

... More
M & L for Marble work 18 to 20mm thick of any shade (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade over and including 10 mm screed bed in CM 1:6 complete all as specified and directed by Engr-In-Charge.

10

-

-

... More
M&L Granite of any type machine cut 20mm thick, set and jointed in cement slurry over & including screed of 15 mm thick in cement mortar (1:6) and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing & with adhesive complete all as specified & directed by Engr-In-Charge.

12

-

-

... More
S&F factory made precast kerb stones in PCC, 1:2 :4, type B-1 using 20mm graded stone aggregate including chamfers, weatherings,throatings etc in smooth finish & set in cement mortar 1:4 including necessary excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed .

7

-

-

... More
Dismantling CI/PVC pipe upto 110mm bore complete all as specified and directed by Engineer in Charge.

70

-

-

... More
S & F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors/in walls complete all as specified and directed by Engineer in Charge.

20

-

-

... More
S & F PVC (SWR) pipes 110 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors/ in walls complete all as specified and directed by Engr-in-charge.

50

-

-

... More
M&L for providing precast cement concrete 1:2:4, type B-0, (using 12.5mm graded crushed stone aggregates) as in louvers and jallies, 40mm thick (measured solid) including all moulding but excluding frame and set in cement mortar 1:4 complete all as specified and directed.

25

-

-

... More
M&L for Providing precast cement concrete in 1:2:4, type B-1, using 20mm graded stone aggregate & set in CM 1:6 in kneelers, apex, stones, anchorage blocks, bonders (for stone walling).corbels, brackets,etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match.

2

-

-

... More
Taking down the steel rolling shutter push type and n.exc 15 Sqm area of clear opening each including hood cover and cleaning the sides of shutter suspension and guide channel and greasing all the moving parts of rolling shutter shaft and replacement of bolts and nuts as required for smooth functioninig of shutters, incl necessary welding wherever required as directed giving proper tension to the spring and refixing the shutter and gear box including hood cover in same opening after repair work complete all as specified and directed by Engr-in-charge.

10

-

-

... More
All as per Ser item No 48.00 above but gear operated rolling shutter exc 15 Sqm but n-exc 30 sqm area including adjustment of gear worms assembly complete all as specifed and directed.

8

-

-

... More
S&F in repair mild steel lock plates/ handles made out of MS flat 35x5 complete all as specifed.

15

-

-

... More
S&F in repair mild steel helical wire spring (Confirming to IS 6248-1970) of gauge 1 of approved make for rolling shutter size upto 30 Sqm complete all as specifed.

6

-

-

... More
S & F in repairs MS gear assembly complete including connecting and fixing the gear box to wall with 4 Nos hexagonal bolts 10mm dia 10 cm long complete and grouting the bolt in cement mortar in 1:3 complete all as specifed.

2

-

-

... More
S & F in repair in MS hood cover made out of mild steel sheets 1.00mm thick including bending the steel sheets to required shape and fixing the sheet to the rolling shutters bracket plate including with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.

40

-

-

... More
S & F in repairs of roller ball bearing ISI marked for 40mm dia pipe shaft all as specified

2

-

-

... More
Supply only MS gear handles of approved make for gear operated rolling shutters complete all as specifed.

20

-

-

... More
S&F for Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; errected in position as indicated, complete: push pull or manual type thickness of latch 1.25 mm complete all as specified and directed

22

-

-

... More
S&F in repairs interlocking lath section formed (confirming to IS 6248-1970) from rolled MS Strip for rolling shutter (of existing width ) 1.00 mm thick complete all as specified and directed.

15

-

-

... More
M & L for preparation of new steel surface of any description over 10 cm in width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specifed.

102

-

-

... More
M&L for preparation of old painted steel surface and applying two coats of synthetic enamel paint all as specified and directed

100

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for including necessary steel double scaffolding complete all as specified and as directed.

8

-

-

... More
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. upto 15 m ht of bldg complete all as specified and directed.

800

-

-

... More
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings upto 15 m ht of bldg including necessary steel double scaffolding complete all as specified and as directed.

200

-

-

... More
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, bend to curve where required and fixed with self tapping screws upto 15 m height of bldg complete all as specified and directed.

50

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.

150

-

-

... More
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.

100

-

-

... More
M&L for Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed in wall/ceiling surface and its accessories including PVC rigid concealed conduit heavy duty suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 3 mm thick plastic laminated Hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for the following all as specified.

-

-

-

... More
One light point/Fan point/Exhaust Point /bell point controlled by one way switch.

50

-

-

... More
One three pin socket out let 5 Amps on the same board with other switches.

25

-

-

... More
One 3 pin, 5A switch socket outlet point on independent board.

15

-

-

... More
All as per Ser item No 66.00 above but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified.

10

-

-

... More
Supply and fixing PVC lamp holder suitable for LED 5 to 20 watt bulb complete all as specified and directed.

10

-

-

... More
S&F in replacement of LED tube light fitting 20W (4 feet long), 230V, surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge.

30

-

-

... More
S&F in replacement of LED tube light fitting 10W (2 feet long), 230V, surface and wall mounted LED batten with polycarbonate housing and integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge.

5

-

-

... More
M&L in replacement ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body complete all as specified.

80

-

-

... More
M&L for submain wiring with two single core PVC FRLS insulated copper conductor 10 Sqmm and same 10 Sqmm for continuous earth wire drawn in existing PVC conduit and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary complete all as specified and directed.

50

-

-

... More
M&L for submain wiring with two single core PVC FRLS insulated copper conductor 6 Sqmm and same 6 Sqmm for continuous earth wire drawn in existing PVC conduit and including taking down old unserviceable wire any type and making good disturbed surfaces of walls as necessary complete all as specified and directed.

50

-

-

... More
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified.

100

-

-

... More
S&F socket two in one 3/5 Pin 5 Amps 230 volt AC supply complete all as specified.

50

-

-

... More
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified.

40

-

-

... More
S&F socket two in one 6 Pin 15/16 Amps 230 volt AC supply complete all as specified.

25

-

-

... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old MCB and making good to the distributed walls and surface area complete all as specified and directed.

30

-

-

... More
Supply and fixing 240V, 10KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning including taking down old MCB SP and making good to the distributed walls and surface area etc complete all as specified and directed.

10

-

-

... More
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN 40 to 63 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking down old MCB SPN and making good to the distributed walls and surface area etc complete all as specified and directed.

10

-

-

... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB top and MCB 20 Amps, 240V, AC supply, including taking down unserviceable AC box all type as specified and directed.

10

-

-

... More
Supply and fixing in replacement ceiling fan regulator, stepped down electronic type single phase, AC supply, 230V, fixed on laminated sheet top cover and connecting up complete all as specified and directed.

10

-

-

... More
Supply and laying rigid non-metallic PVC conduit size 25mm exclusive of boxes (juction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddies pipe hooks etc with all fitting including taking down old unserviceable pipe any type complete all as specified and directed.

100

-

-

... More
S&F in replacement of hylam sheet suitable size with cutting slot for mounting of switches sockets, fan regulators, including nut, washer thimble etc with 3mm thick plastic laminated sheet cover any size and making good to the disturbed surfaces of walls, matching the colour with existing surface complete all as specified and directed.

3

-

-

... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 75mm x 75mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 75mm x 75mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 100mm x 100mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 100mm x 100mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 150mm x 75mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 150mm x 75mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.

10

-

-

... More
S&F in replacement of MS sunken box 1.6mm thick galvanised steel pressed sunken terminal boxes size 150mm x 150mm and 60mm deep, painted on both sides inside and outside with one coat of red oxide primer of suitable size for mounting of switches sockets, fan regulators etc with 3mm thick plastic laminated sheet cover size 150mm x 150mm etc making good to the disturbed surfaces of walls, maching the colour with existing surface complete all as specified and directed by Engineer-in-Charge.

8

-

-

... More
Taking down re-fixing only exhaust fans including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connection up and including three core PVC insulated PVC sheathed copper conductor flexible cable 1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long including hole in wall and making good the disturbed surfaces complete all as specified and directed.

20

-

-

... More
Taking down and re-fixing of Geyser and Solar Water System complete with accessories three core copper wire upto 5 mtr 4 Sqmm for connecting complete all as specified and directed.

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.